• 제목/요약/키워드: Link Type

검색결과 791건 처리시간 0.035초

Design of Optimal Locating Point of the Hydraulic Cylinder Actuating a Roller-Link Type Rotating Floodgate (콤플렉스법에 의한 롤러-링크 부착형 전도수문 구동용 유압실린더의 최적 설치점 설계)

  • Lee, S.R.
    • Journal of Drive and Control
    • /
    • 제9권3호
    • /
    • pp.29-36
    • /
    • 2012
  • The hydraulic cylinder is used for actuating the roller-link type rotating floodgate which controls the volume of water in the reservoir. The locating points of hydraulic cylinder are restricted to the limited space and determined to minimize the cylinder force necessary for actuating the floodgate. Generally, the head end point of cylinder is fixed at underground and the rod end point of cylinder is connected to the support link. Therefore there exist three design variables to be determined to minimize the cylinder force within the rotating range of floodgate. First, the mathematical model of the roller-link type rotating floodgate is derived to find the cylinder force corresponding to the floodgate angle. Then, the optimal locating point of hydraulic cylinder is searched using the complex method that is one kind of constrained direct search method.

Three-Phase Soft Switching Sinewave Inverter with Bridge Power Module Package Configurated Auxiliary Resonant AC Link Snubber

  • Iyomori Hisashi;Nagai Shin-ichiro;Shiraishi Kazuhiro;Ahmed Tarek;Eiji Hiraki;Mutsuo Nakaoka
    • Proceedings of the KIPE Conference
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.507-510
    • /
    • 2003
  • This paper presents a novel prototype of tile three-phase bridge power block module type a auxiliary resonant AC link snubber circuit, which is effectively used for the three-phase voltage source type sinewave soft switching PWM inverter using IGBTs. Its operating principle Is described for current source load model, along with its practical design approach based on the simulation data. The performance evaluation of the three-phase voltage source type snewave soft switching PWM inverter incorporating a single three-phase bridge mo여le of active auxiliary resonant AC link snubber treated here Is illustrated, which is concerned with power duality efficiency power loss analysis. This inverter is discussed as compared with those of tile three-phase voltage source type sinewave hard switching PWM inverter. The power loss analysis of this soft switching PWM Inverter using IGBT power modules is evaluated on the basis of the measured v-i characteristics and switching power losses of IGBT, and antiparaliel diodes. The practical effectiveness of this inverter is proven by the power loss analysis for distributed power supply.

  • PDF

The efficient ACL data transmission method by Link quality for bluetooth (블루투스에서의 링크품질에 따른 효율적인 ACL데이터 전송 방법)

  • 김창윤;양영배;임재윤
    • Proceedings of the IEEK Conference
    • /
    • 대한전자공학회 2002년도 하계종합학술대회 논문집(1)
    • /
    • pp.295-298
    • /
    • 2002
  • This paper has been proposed about the efficient ACL data transmission method by link quality for Bluetooth. By tile host tile HCI command confirm tile link quality values and change the packet type into several environment. And then we can analyze the data rate through this. From the construed result, after the suitable ACL packet type had been selected, the efficient data transmission method was proposed.

  • PDF

An Analysis Method for Detecting Vulnerability to Symbolic Link Exploit (심볼릭 링크 공격 취약성 검출을 위한 분석 기법)

  • Joo, Seong-Yong;Ahn, Joon-Seon;Jo, Jang-Wu
    • The KIPS Transactions:PartA
    • /
    • 제15A권1호
    • /
    • pp.45-52
    • /
    • 2008
  • In this paper we define a vulnerable code to symbolic link exploit and propose a technique to detect this using program analysis. The existing methods to solve symbolic link exploit is for protecting it, on accessing a temporary file they should perform an investigation whether the file is attacked by symbolic link exploit. If programmers miss the investigation, the program may be revealed to symbolic link exploit. Because our technique detects all the vulnerable codes to symbolic link exploit, it helps programmers keep the program safety. Our technique add two type qualifiers to the existing type system to analyze vulnerable codes to symbolic link exploit, it detects the vulnerable codes using type checking including the added type qualifiers. Our technique detects all the vulnerable codes to symbolic link exploit automatically, it has the advantage of saving costs of modifying and of overviewing all codes because programmers apply the methods protecting symbolic link exploit to only the detected codes as vulnerable. We experiment our analyzer with widely used programs. In our experiments only a portion of all the function fopen() is analyzed as the vulnerabilities to symbolic link exploit. It shows that our technique is useful to diminish modifying codes.

Joint and Link Module Geometric Shapes of Modular Manipulator for Various Joint Configurations (다양한 관절 구성을 위한 모듈라 매니퓰레이터의 관절 및 링크 모듈 형상 도출)

  • Hong, Seonghun;Lee, Woosub;Lee, Hyeongcheol;Kang, Sungchul
    • The Journal of Korea Robotics Society
    • /
    • 제11권3호
    • /
    • pp.163-171
    • /
    • 2016
  • A modular manipulator in serial-chain structure usually consists of a series of modularized revolute joint and link modules. The geometric shapes of these modules affect the number of possible configurations of modular manipulator after assembly. Therefore, it is important to design the geometry of the joint and link modules that allow various configurations of the manipulators with minimal set of modules. In this paper, a new 1-DoF(degree of freedom) joint module and simple link modules are designed based on a methodology of joint configurations using a series of Rotational(type-R) and Twist(type-T) joints. Two of the joint modules can be directly connected so that two types of 2-DoFs joints could be assembled without a link module between them. The proposed geometries of joint and link modules expand the possible configurations of assembled modular manipulators compared to existing ones. Modular manipulator system of this research can be a cornerstone of user-centered markets with various solution but low-cost, compared to conventional manipulators of fixed-configurations determined by the provider.

A Study on Performance Improvement of Gear Type Vane Damper in FD Fan - Productivity Increases & Construction Improvement - (FD FAN에서 기어식 베인 댐퍼의 성능개선에 관한 연구 - 생산 및 구조 융합형 기술 -)

  • Jang, Sung-Cheol;Han, Sang-Ho;Kim, Jin-Woo
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • 제19권1호
    • /
    • pp.134-139
    • /
    • 2010
  • In this study, we developed the gear type vane damper replacing the link type through gear design using Finite Element Analysis(FEA). FEA about the pinion and the vane shaft in the boss of gear type damper for quality improvement was accomplished. We analyzed fluid flow according to angular displacement. Catched the problem of the torque and backlash bring to the pinion as structure improvement of the forced draft fan(FD FAN). Finally, we compared the gear driving result with simulation. It is the objective of the present study to identify a nonlinear flow rate control of gear type vane damper and to suggest a damper shape with a linear flow rate control. This study is related to the development of gear type vane damper change link type in forced draft fan.

A Report on Test Results of Fusible-Link Type Heat Responsive Links (Fusible Link Type 감열체 성능시험보고)

  • Gwon, O-Seung
    • Fire Protection Technology
    • /
    • 통권10호
    • /
    • pp.5-8
    • /
    • 1991
  • This report is explained about test results of heat responsive links for fire protection service, such as fire dampers and fire doors, automatic fire suppression systems and so forth. The testing program was progressed divided by two testing items, external appearance test and performance test. The object of this report is present the problem which appear from the analysis of test results.

  • PDF

Developing the Traffic Accident Models of Arterial Link Sections by Driving Type (운전 유형에 따른 가로구간 사고모형 개발)

  • Kim, Kyung-Hwan;Park, Byung-Ho
    • Journal of the Korean Society of Safety
    • /
    • 제25권6호
    • /
    • pp.197-202
    • /
    • 2010
  • This study deals with the accident models of arterial link sections by driving type. The objectives is to develop models by driving type using the accident data of 24 arterial links in Cheong-ju. In pursuing the above, this study gives particular emphasis to modeling such the accidents as the straight, lane change and others. The main results analyzed are as follows. First, the number of accidents is analyzed to account for about 59% in straight, 31% in lane change and 10% in others. Second, the number of left-turn lane as common variables, and the ADT, number of pedestrian crossings, connecting roads and link length as specific variables are selected in developing models(number of accident and EPDO). Third, 8 models which are all statistically significant are developed. Finally, RMSE of the driving type models was analyzed to be better than that of dummy variable.

A Study on Performance Improvement of Gear Type Vane Damper in Marine/Offshore FD Fan (선박/해양플랜트용 FD FAN의 기어식 베인 댐퍼 성능 개선에 관한 연구)

  • Jang, Sung-Cheol;Jung, Wan-Bo;Yi, Chung-Sub
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • 제14권2호
    • /
    • pp.7-13
    • /
    • 2015
  • In this study, we developed a gear-type vane damper which replaces the link type through a proper gear design by means of a finite element analysis. We analyzed the fluid flow according to the amount of angular displacement. torque and backlash problems were addressed in conjunction with the pinion as a structural improvement of the forced draft fan (FD FAN). Through an environmental test. Also, results nearly identical to those in the test could be drawn when using a numerical method. Finally, we compared the gear driving result with simulation results. objective of the present study is to identify a nonlinear flow rate control method for a gear-type vane damper and to propose a damper shape which offers linear flow rate control. This study is related to the development of a gear-type vane damper of the change-link type in a forced draft fan.

A Study on Designing Link Type Percussion Lock (링크식 격발기구 설계에 관한 연구)

  • Lee, Joon-Ho;Yeo, Woon-Joo;Choe, Eui-Jung
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • 제12권3호
    • /
    • pp.259-265
    • /
    • 2009
  • In the traditional percussion locks of small arms, a firing pin is struck by a hammer rotating on a single center of rotation, which makes the percussion mechanism simple and reliable. In order to strike the firing pin by the hammer, however, the firing pin should be located within the radius of rotation of the hammer. As the distance between the striking point of the firing pin and the center of rotation of the hammer becomes longer, the radius of rotation of the hammer should also be increased, which results in the increase of the volume and weight of the small arms because the hammer needs the more space for its operation inside of the small arms. In this paper, a link type percussion lock was newly proposed in order to overcome the limitation of designing small arms when using traditional percussion locks, as mentioned above. The link type percussion lock was modeled by using multi-body dynamics software and designed to satisfy the requirements such as striking force level of the hammer exerting on the firing pin enough to detonate the percussion cap of ammunitions and the safety on the accidental drop. It was applied to the newly developed dual-barrel weapon system, in which the weight and overall length are important design factors, and verified by durability test and drop test on the ground.