• Title/Summary/Keyword: Linearity assessment

Search Result 78, Processing Time 0.025 seconds

Calculation of Effective Half-life of Gamma Emission Radionuclide using Bio-kinetic Model (생체역동학 모델을 이용한 감마선 방출 핵종의 유효반감기 계산)

  • Lee, Sang-Kyung;Jeong, Kyu-Hwan;Lee, Ji-Yon;Kim, Bong-Gi;Kim, Jung-Min
    • Journal of Radiation Industry
    • /
    • v.12 no.4
    • /
    • pp.277-285
    • /
    • 2018
  • Patients administered radioisotope for medical purposes are regulated by each country to quarantine them until their body's radioactivity contents decrease below release criteria. To predict the quarantine period and provide it to medical staffs and patients, it is necessary to approach the assessment of the exposure dose of persons due to patients in a realistic manner. For this purpose, a whole-body effective half-life should be applied to the dose assessment equation instead of the physical half-life. In this study, we constructed a bio-kinetic model for each nuclear species based on the ICRP publication to obtain a whole-body effective half-life of 10 unsealed gamma-ray emitting nuclei from the notification of Nuclear Safety and Security Commission, and calculated the effective half-life mathematically by simulating the distribution of the radioisotope administered in the whole body as well as each organ scale. The whole-body effective half-life of $^{198}Au$, $^{67}Ga$, $^{123}I$, $^{111}In$, $^{186}Re$, $^{99m}Tc$, and $^{201}TI$ were 1,93, 2.57, 0.295, 2.805, 1.561, 0.245, and 2.397 days respectively. However, it was found to be undesirable to offer a single value of the effective half-life of $^{125}I$, $^{131}I$, and $^{169}Yb$ because the changes in the effective half-life show no linearity. A bio-kinetic model created for the internal exposure assessment has been shown to be possible to calculate the effective half-life of radioisotopes administered in the patient's body, but subsequent studies of radiolabeled compounds are required as well.

Simultaneous Analysis of Mycotoxins and Risk Assessment in Seeds using LC-MS/MS (LC-MS/MS를 이용한 종자류 생약의 곰팡이독소 동시분석 및 위해도 평가)

  • Choi, Eun Jung;Park, Young Ae;Choi, Su Jeong;Jung, Sam Ju;Park, Youn Sun;Hwang, In Sook;Yu, In Sil;Shin, Gi Young
    • Korean Journal of Pharmacognosy
    • /
    • v.51 no.4
    • /
    • pp.270-277
    • /
    • 2020
  • This study analyzed mycotoxins, aflatoxin B1, B2, G1, G2, fumonisin B1, B2, ochratoxin A and zearalenone, using LC-MS/MS and conducted risk assessment on 54 samples of seeds distributed in SeoulYangnyeongsi and the management status of extramural herbal dispensary facility. The matched calibration showed a good linearity as observed in 6 concentration levels(r2>0.999) as a result of method validation applied with Arecae semen. Limits of detection(LOD) and quantification(LOQ) were in the range of 0.02-0.11 ㎍/kg and 0.08-0.34 ㎍/kg, respectively. Recoveries also estimated, ranging from 65.1-99.7% with relative standard deviation(RSD) 0.5-6.3%. As a result of the method on 54 samples, mycotoxins were detected in 16 samples. Among them, two Thujae semen showed a degree of concentration that exceeded the aflatoxin specification. In the risk assessment, the human exposure safety standard values were calculated as ADI(Acceptable Daily Intake) for aflatoxin B1, fumonisin and zearalenone. Ochratoxin A was calculated as PTWI(Provisional Tolerable Weekly Intake). The MOE(Margine of Exposure) of aflatoxin B1 was in the range of 40.36-3536.88. And no items exceeded 100% in %TDI(Tolerable Daily Intake) and %TWI(Tolerable Weekly Intake) of fumonisin, zearalenone and ochratoxin A.

Residue Characteristics and Risk Assessment of Pesticides (Boscalid and Pyraclostrobin) in Hylomecon vernalis (피나물 중 boscalid 및 pyraclostrobin의 토양 처리시 잔류특성 및 안전성 평가)

  • Yu, Ji-Woo;Song, Min-Ho;Kim, Jinchan;Lee, Kwanghun;Ko, Rakdo;Keum, Young-Soo;Lee, Jiho
    • Korean Journal of Environmental Agriculture
    • /
    • v.41 no.2
    • /
    • pp.95-100
    • /
    • 2022
  • BACKGROUND: This study was aimed to determine characteristics of residues of the soil-treated boscalid and pyraclostrobin within Hylomecon vernalis and to evaluate the risks from intake of the residual pesticides in the crop. METHODS AND RESULTS: The pesticides were treated to soils at two different concentrations, and the plant samples were collected 57 days after seeding. The samples were extracted using the QuEChERS extraction kit (MgSO4 4 g, NaCl 1 g). The quantitative methods for boscalid and pyraclostrobin were validated using linearity, recovery, and CV (coefficient of variation). Risk assessment of the pesticides was performed using Korea national nutrition statistics 2019. CONCLUSION(S): The residual levels of boscalid were 0.02-0.05 mg/kg (for the treatment at 6 Kg/10a) and 0.05-0.08 mg/kg (for the treatment at 12 Kg/10a), respectively. The residual concentrations of pyraclostrobin were below the LOQ. The amounts of pesticides were less than Maximum Residue Limits specified by the Korean Ministry of Food and Drug Safety. The maximum hazard indices of boscalid in chwinamul and amaranth for consumers were 0.0075% and 0.1525%, respectively, and it indicates that the risk of the pesticides from the crop is considered to be low.

Bioequivalence Assessment of DM Tablet to Motilium-$M^{(R)}$ Tablet (모티리움엠정(말레인산 돔페리돈 12.72 mg)에 대한 디엠정의 생물학적동등성 평가)

  • Cho, Seong-Wan;Kim, Young-Il;Lee, Jong-Oh;Bang, Joon-Seok;Jeong, Ji-Hoon
    • Korean Journal of Clinical Pharmacy
    • /
    • v.18 no.2
    • /
    • pp.106-113
    • /
    • 2008
  • The aim of this study was to evaluate the bioequivalence of two domperidone preparations. Bioequivalence assessment was conducted on 34 healthy volunteers who received two tablets (Domperidone Maleate, 12.72 mg/tablet) in the fasting state, in a randomized balanced $2{\times}2$ cross-over study design. This whole study was performed according to the implementation guidelines of the Korea Food Drug Administration. After dosing of two tablets, blood samples were collected serially for a period of 36 hours. Plasma was analyzed for domperidone by using LC/MS/MS assay method. The analysis system was validated in specificity, accuracy, precision, and linearity. $AUC_t$, (the area under the plasma concentration-time curve from the zero-time to 36 hr) was calculated through the trapezoidal rule. $C_{max}$ (maximum plasma drug concentration) and $T_{max}$ (time to reach $C_{max}$) were compiled from the plasma domperidone concentration-time data of each volunteer. No significant sequence effect was found for the bioavailability parameters indicating that the cross-over design was properly performed. The 90%-Confidence intervals of the $AUC_t$ ratio and the $C_{max}$ were from log 0.8007 to log 1.1240 and log 0.8645- log 1.2483, respectively. These values were within the acceptable bioequivalence intervals between 0.80 and 1.25. Therefore, this study demonstrated that two formulations have bioequivalence with respect to the rate and extent of absorption.

  • PDF

Body Composition Variations for Cerebral Infarction Patients Classified as Male and Female in Long-term Care Hospitals

  • Yoo, Chan-Uk;Hwang, Youngjun;Kim, Gunho;Hahn, Eun Joo;Jeon, Gyerok;Kim, Jaehyung
    • Journal of Korea Multimedia Society
    • /
    • v.21 no.6
    • /
    • pp.723-735
    • /
    • 2018
  • Indicators to quantitatively assess the physical conditions can help optimize the effectiveness of rehabilitation therapy for stroke patients. The body composition variations in the paretic and non-paretic regions of stroke patients with cerebral infarction (7 males, 31 females) were analyzed using multi-frequency bioelectrical impedance. Specifically, resistance (R), lean mass (LM), fat mass (FM), extracellular water (ECW), intracellular water (ICW), R/LM relation, basal metabolic rate (BMR)/LM relation were utilized to evaluate the paretic and non-paretic regions of subjects with cerebral infarction. These values showed significant differences in gender and paretic/non-paretic regions. R and FM were high but LM and ICW were lower in female and paralysis. ECW was lower in females than males, but there was no considerable difference between paralysis and non-paralysis in both males and females. In addition, there was an inverse distribution between R and LM in paretic and non-paretic regions, with males on the upper left and females on the lower right. Furthermore, the relationship between BMR and LM showed excellent linearity (slope: 22.17 kcal/day/kg) irrespective of gender, paralysis, and non-paralysis. An easy, non-invasive and quantitative assessment using bioelectrical impedance would provide an useful tool for evaluating patients with cerebral infarction receiving rehabilitation therapy.

Necessity of high-performance liquid chromatography validation in good laboratory practice systems (비임상시험관리기준 시스템에서 고성능액체크로마토그래피 분석법 정확도 검증의 필요성)

  • Su Bin Yang;Changyul Kim
    • Journal of the Korean Applied Science and Technology
    • /
    • v.41 no.2
    • /
    • pp.172-187
    • /
    • 2024
  • In good laboratory practice (GLP), analytical method validation prior to toxicity testing is important in terms of concentration setting and sample preparation. The testing agency performed validation of the two requested test substances using high-performance liquid chromatography (HPLC), and as a result, the analysis satisfied the criteria for specificity, system suitability, linearity, intra-day reproducibility, homogeneity, stability, concentration analysis, and quality control. The method was established and validated. However, the content of standard substances in the test report of the requesting institution was found to be 1.34 and 1.17 times higher than the results of the testing institution, confirming that deriving results through validation of analysis methods suitable for GLP is important in terms of securing reliability and stability.

Determination of Mycotoxins in Agricultural Products Used for Food and Medicine Using Liquid Chromatography Triple Quadrupole Mass Spectrometry and Their Risk Assessment (LC-MS/MS를 이용한 식·약 공용 농산물의 곰팡이독소 분석 및 위해평가)

  • Choi, Su-Jeong;Ko, Suk-Kyung;Park, Young-Ae;Jung, Sam-Ju;Choi, Eun-Jung;Kim, Hee-sun;Kim, Eun-Jung;Hwang, In-Sook;Shin, Gi-Young;Yu, In-Sil;Shin, Yong-Seung
    • Journal of Food Hygiene and Safety
    • /
    • v.36 no.1
    • /
    • pp.24-33
    • /
    • 2021
  • For this study, we surveyed concentrations of 8 mycotoxins (aflatoxin B1, B2, G1, G2, ochratoxin A, fumonisin B1, B2 and zearalenone) in agricultural products used for food and medicine by liquid chromatography-tandem mass spectrometry and conducted a risk assessment. Samples were collected at the Yangnyeong Market in Seoul, Korea, between January and November 2019. Mycotoxins were extracted from these samples by adding 0.1% formic acid in 50% acetonitrile and cleaned up by using an ISOLUTE Myco cartridge. The method was validated by assessing its matrix effects, linearity, limit of detection (LOD), limit of quantification (LOQ), recovery and precision using four representative matrices. Matrix-matched standard calibration was used for quantification and the calibration curves of all analytes showed good linearity (r2>0.9999). LODs and LOQs were in the range of 0.02-0.11 ㎍/kg and 0.06-0.26 ㎍/kg, respectively. Sample recoveries were from 81.2 to 118.7% and relative standard deviations lower than 8.90%. The method developed in this study was applied to analyze a total of 187 samples, and aflatoxin B1 was detected at the range of 1.18-7.29 ㎍/kg (below the maximum allowable limit set by the Ministry of Food and Drug Safety, MFDS), whereas aflatoxin B2, G1 and G2 were not detected. Mycotoxins that are not regulated presently in Korea were also detected: fumonisin (0.84-14.25 ㎍/kg), ochratoxin A (0.76-17.42 ㎍/kg), and zearalenone (1.73-15.96 ㎍/kg). Risk assessment was evaluated by using estimated daily intake (EDI) and specific guideline values. These results indicate that the overall exposure level of Koreans to mycotoxins due to the intake of agricultural products used for food and medicine is unlikely to be a major risk factor for their health.

The Construction of Solid State Detector System Using Commercially Available Diode and Its Application (정류기형 다이오드를 이용한 반도체 방사선 검출 장치의 제작과 그 응용에 관한 연구)

  • 신동오;홍성언;이병용;이명자
    • Progress in Medical Physics
    • /
    • v.1 no.1
    • /
    • pp.91-95
    • /
    • 1990
  • The solid state detector system was constructed using commercially available rectifier diode for the assessment of quality assurance in radiotherapy. Dosimetry system which consists of the electrometer and the water phanton was used for measuring small field size scanning. The measured results, which had linearity in accordance with variation of radiation dose for gamma-ray of Co- 60 and 6 and 10MV photons of linear accelerator, showed quite linear characteristics within 1% error. The percent depth dose of 10MV photon of Mevatron KD linear accelerator was measured in small field size using diode, and the results were compared with that of using ion chambers. The results show that the difference of percent depth dose between the value of diode and that of ion chamber was negligible in large field size. However, in small size less than 4$\times$4cm, the difference of percent depth dose estimated by diode and ion chamber was 4.7% by extrapolation to 0$\times$0cm. Considering the smaller volume of diode than that of ion chamber, it might be more reliable to use diode for estimating percent depth dose. Above results suggest that diode can be used for routine check such as beam profile, flatness, symmetry and energy

  • PDF

The Assessment on the Sound Quality of Reduced Frequency Selectivity of Hearing Impaired People (난청인의 주파수 선택도 둔화현상이 음질에 미치는 영향 평가)

  • An, Hong-Sub;Park, Gyu-Seok;Jeon, Yu-Yong;Song, Young-Rok;Lee, Sang-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.6
    • /
    • pp.1196-1203
    • /
    • 2011
  • The reduced frequency selectivity is a typical phenomenon of sensorineural hearing loss. In this paper, we compared two modeling methods for reduced frequency selectivity of hearing impaired people. The two models of reduced frequency selectivity were made using LPC(linear prediction coding) algorithm and bandwidth control algorithm based on ERB(equivalent rectangular bandwidth) of auditory filter, respectively. To compare the effectiveness of two models, we compared the result of PESQ (perceptual evaluation of speech quality) and LLR(log likelihood ratio) using 36 Korean words of two syllables. To verify the effect on noise condition, we mixed white and babble noise with 0dB and -3dB SNR to speech words. As the result, it is confirmed that the PESQ score of bandwidth control algorithm is higher than the score of LPC algorithm, on the other hands, and the LLR score of LPC algorithm is lower than the score of bandwidth control algorithm. It means that both non-linearity and widen auditory filter characteristics caused by reduced frequency selectivity could be more reflected in bandwidth control algorithm than in LPC algorithm.

A New Analysis of p-Coumaric Acid and Trans-cinnamic Acid in Propolis By UPLC (UPLC를 이용한 프로폴리스 중 p-Coumaric Acid와 Trans-cinnamic Acid 분석법)

  • Kim, Se Gun;Hong, In Pyo;Woo, Soon Ok;Jang, Hye Ri;Han, Sang Mi
    • Korean Journal of Pharmacognosy
    • /
    • v.47 no.2
    • /
    • pp.186-191
    • /
    • 2016
  • A new UPLC-DAD method for simultaneous determination of p-coumaric acid and trans-cinnamic acid in propolis was developed using Halo-C18 column and step gradient elution of MeCN and $0.1%H_3PO_4$ in 8 min. The method was validated by specificity, linearity, limit of detection, limit of quantification, precision(intra- and inter-day variability) and recovery tests. The validated method was sufficiently applicable for quantitative analysis of propolis products as well as propolis collected from different regions in Korea. The established method is simple, appropriate and efficient, and can be used for quality assessment of Korean propolis.