• Title/Summary/Keyword: Linear temperature distribution

Search Result 260, Processing Time 0.025 seconds

A Study on the Temperature Distribution and Computational Effort of Rectangular Cross-Section by the Finite Dynamic Element Method (유한 요소법에 의한 구형단면의 온도분포와 Computational Effort에 관한 연구)

  • Yong, Ho-Taek
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.13 no.2
    • /
    • pp.10-15
    • /
    • 1984
  • The aims of this study are to obtain a suitable method and a proper mesh for investigation of the temperature distribution and heat transfer. The relative errors of temperature distribution and heat transfer for each mesh are acquired in accordance with linear finite element (FEM 3), square finite element (FEM 6), cubic finite element (FEM 10), and finite difference method (FDM). It has been found that FEM 10 is the most accurate measure to obtain the temperature distribution and heat transfer. However, no significant results have been obtained successfully, because when higher order finite element methods are used the more computational efforts are necessary due to the distribution of elements. The results of this study are as follows ; 1 . In case of a=b=L, meshes for less than $1\%$ relative errors (temperature distribution) acquired in various methods to exact solution are $2\times2,\;4\times4,\;8\times8\;and\;8\tiems8$ for each FEM 10, FEM 6, FEM 3 and FDM and a=L, b=1/2L are $10\times5$ for each FEM 3 and FDM. And the tendency of results acquired of heat transfer is similar to those above. 2 . In computational efforts (a=b=L), FEM 6 has taken 21 times. and FEM 10 154times FEM 3 and FDM and FEM 3 is the sane as FDM.

  • PDF

Real Time Temperature Distribution Measurement of a Microheater by Using Off-Axis Digital Holography (Off-Axis 디지털홀로그래피를 이용한 마이크로히터의 실시간 온도분포측정)

  • Tserendolgor, D.;Baek, Byung-Joon;Kim, Dae-Suk
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.2
    • /
    • pp.106-113
    • /
    • 2011
  • We describe a single shot off-axis digital holography based on a Mach-Zehnder interferometic scheme for measuring temperature distribution of a microheater. The proposed scheme has the capability of reconstructing object phase image which is dependent of the temperature distribution in real time. Experimental results shows that there is a moderate linear relationship between the measured phase and temperature in the range of $20^{\circ}C$ to $60^{\circ}C$. We expect that the proposed system can provide a very reliable and fast solution in various surface temperature distribution measurement applications.

Establishing non-linear convective heat transfer coefficient

  • Cuculic, Marijana;Malic, Neira Toric;Kozar, Ivica;Tibljas, Aleksandra Deluka
    • Coupled systems mechanics
    • /
    • v.11 no.2
    • /
    • pp.107-119
    • /
    • 2022
  • The aim of the work presented in this paper is development of numerical model for prediction of temperature distribution in pavement according to the measured meteorological parameters, with introduction of non-linear heat transfer coefficient which is a function of temerature difference between the air and the pavement. Developed model calculates heat radiated from the pavement back in the air, which is an important part of the heat trasfer process in the open air surfaces. Temperature of the pavement surface, heat radiation together with many meteorological parameters were measured in series during two years in order to validate the model and calibrate model parameters. Special finite element method for temperature heat transfer towards the soil together with the time integration scheme are used to solve the governing equation. It is proved that non-linear heat transfer coefficient, which is a function of time and temperature difference between the air and the pavement, is required to decribe this phenomena. Proposed model includes heat tranfer coefficient callibration for specific climate region, through the iterative inverse procedure.

Analytical and multicoupled methods for optimal steady-state thermoelectric solutions

  • Moreno-Navarro, Pablo;Perez-Aparicio, Jose L.;Gomez-Hernandez, J.J.
    • Coupled systems mechanics
    • /
    • v.11 no.2
    • /
    • pp.151-166
    • /
    • 2022
  • Peltier cells have low efficiency, but they are becoming attractive alternatives for affordable and environmentally clean cooling. In this line, the current article develops closed-form and semianalytical solutions to improve the temperature distribution of Bi2Te3 thermoelements. From the distribution, the main objective of the current work-the optimal electric intensity to maximize cooling-is inferred. The general one-dimensional differential coupled equation is integrated for linear and quadratic geometry of thermoelements, under temperature constant properties. For a general shape, a piece-wise solution based on heat flux continuity among virtual layers gives accurate analytical solutions. For variable properties, another piece-wise solution is developed but solved iteratively. Taking advantage of the formulae, the optimal intensity is directly derived with a minimal computational cost; its value will be of utility for more advanced designs. Finally, a parametric study including straight, two linear, barrel, hourglass and vase geometries is presented, drawing conclusions on how the shape of the thermoelement affects the coupled phenomena. A specially developed coupled and non-linear finite element research code is run taking into account all the materials of the cell and using symmetries and repetitions. These accurate results are used to validate the analytical ones.

A PID Control of Supply Duct Outlet Air Temperature in Personal Environment Module

  • Park, Young-Chil
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.11 no.2
    • /
    • pp.82-90
    • /
    • 2003
  • The work presented here is a design and an implementation of PID control system to regulate a supply duct outlet air temperature in PEM (Personal Environment Module). In PEM, the air is heated to the required temperature while it flows through the supply duct without any mixing chamber. This makes the control of air temperature in PEM difficult. A simulation is done first to understand the relationship between a temperature distribution in working area, flow rate and the outlet air temperature of PEM. Then a linear dynamic model of heating process in PEM is derived. P, PD and PID type control systems, to provide the rapid response without overshoot and saturation in heater command voltage, are designed using a linear model obtained. Experimentally obtained data shows that the control system satisfies the design criteria and works properly in controlling the supply duct outlet air temperature.

Effects of Climate Change on the Occurrence of Two Fly Families (Phoridae and Lauxaniidae) in Korean Forests

  • Kwon, Tae-Sung;Lee, Cheol Min;Jie, Okyoung;Kim, Sung-Soo;Jung, Sungcheol;Park, Young-Seuk
    • Korean Journal of Ecology and Environment
    • /
    • v.54 no.1
    • /
    • pp.71-77
    • /
    • 2021
  • Using data from flies collected with pitfall traps in 365 forests on a nationwide scale in Korea, the abundance and distribution changes of two families (Phoridae and Lauxaniidae) in Korean forests were predicted at the genus level according to two climate change scenarios: RCP 4.5 and RCP 8.5. The most suitable temperature for the 17 major genera was estimated using a weighted average regression model. Stichillus and Anevrina displayed the lowest optimum temperature with 7.6℃ and 8.5℃ in annual mean temperature, respectively, whereas Chonocephalus had the highest optimum temperature with 12.1℃. Among thirty genera, seven genera (four from Phoridae and three from Lauxaniidae), which showed their abundance in a bell-type or linear pattern along the temperature gradient, were used for predicting the distribution changes according to the future climate change scenarios. All the taxa of this study are expected to decrease in abundance and distribution as a function of temperature increase. Moreover, cold-adapted taxa were found to be more affected than warm-adapted taxa.

Measurement of Internal Temperature Distribution for the Evaluation of Focused Ultrasound (FUS) Stimulation Devices (집속초음파 자극기의 성능평가를 위한 팬텀 내부온도 측정)

  • Doh, Il;Joe, Daniel J.;Kim, Sung Mok;Baik, Kyung Min;Kim, Yong Tae;Park, Seung Min
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.3
    • /
    • pp.147-152
    • /
    • 2022
  • This research is to measure real-time temperature distribution inside a tissue-mimicking phantom for the safety and effectiveness evaluations of focused ultrasound (FUS) device capable of linear scanning stimulation. Since the focusing area of the FUS stimulation device is smaller than diameter of conventional thermal probe and keeps moving, it is impossible to monitor temperature distribution inside the phantom. By using the phantom with a thin film temperature sensor array inserted, real-time temperature change caused by the FUS device was measured. The translation of the measured temperature peak was also tracked successfully. The present phantom had been experimentally proven to be applicable to validate the performance and safety of the therapeutic ultrasound devices.

Design thermal loading for composite bridges in tropical region

  • Au, F.T.K.;Cheung, S.K.;Tham, L.G.
    • Steel and Composite Structures
    • /
    • v.2 no.6
    • /
    • pp.441-460
    • /
    • 2002
  • In the design of bridges, it is important to consider the thermal stresses induced by the non-linear temperature distribution as well as the variation of effective temperature in the bridge deck. To cope with this, design temperature profiles are provided by design codes, which are normally based on extensive research work. This paper presents the results of a comprehensive investigation on the thermal behaviour of bridges in Hong Kong with special emphasis on composite bridges. The temperature distribution in bridges depends primarily on the solar radiation, ambient air temperature and wind speed in the vicinity. Apart from data of the meteorological factors, good estimates of the thermal properties of material and the film coefficients are necessary for the prediction of temperature distribution. The design temperature profiles for various types of composite bridge deck with bituminous surfacing and concrete slab of different thicknesses are proposed. The factors affecting the design effective temperature are also reviewed and suitable values for Hong Kong are proposed. Results are compared with recommendations of the current local code. The method facilitates the development of site-specific temperature profiles for code documents, and it can also be applied to create zoning maps for temperature loading for large countries where there are great climatic differences.

Thermal buckling response of functionally graded sandwich plates with clamped boundary conditions

  • Abdelhak, Zohra;Hadji, Lazreg;Daouadji, T. Hassaine;Adda Bedia, E.A.
    • Smart Structures and Systems
    • /
    • v.18 no.2
    • /
    • pp.267-291
    • /
    • 2016
  • In this research work, an exact analytical solution for thermal buckling analysis of functionally graded material (FGM) sandwich plates with clamped boundary condition subjected to uniform, linear, and non-linear temperature rises across the thickness direction is developed. Unlike any other theory, the number of unknown functions involved is only four, as against five in case of other shear deformation theories. The theory accounts for parabolic distribution of the transverse shear strains, and satisfies the zero traction boundary conditions on the surfaces of the plate without using shear correction factor. A power law distribution is used to describe the variation of volume fraction of material compositions. Equilibrium and stability equations are derived based on the present refined theory. The non-linear governing equations are solved for plates subjected to simply supported and clamped boundary conditions. The thermal loads are assumed to be uniform, linear and non-linear distribution through-the-thickness. The effects of aspect and thickness ratios, gradient index, on the critical buckling are all discussed.

Inverse Relationship of Hemiptera Richness with Temperature in South Korea

  • Kwon, Tae-Sung;Jung, Sungcheol;Park, Young-Seuk
    • Korean Journal of Ecology and Environment
    • /
    • v.54 no.2
    • /
    • pp.102-107
    • /
    • 2021
  • The distribution pattern of species richness was determined by temperature. To examine the relationship between hemipteran richness and temperature, hemipteran species were collected using pitfall traps at six different oak forest sites with different annual mean temperatures in South Korea. Multiple linear regression analyses were conducted with mean annual temperature (MAT) and plant richness to evaluate differences in hemipteran richness. The influences of MAT and plant richness of study sites on hemipteran richness were examined by comparing three models (plant richness+MAT+MAT2, plant richness+MAT, and MAT) or two models (plant richness+MAT and MAT). Hemipteran richness showed an inverse diversity pattern as a function of temperature, with higher species richness at lower temperature sites. Meanwhile, Aphididae showed a bell-shaped diversity pattern with the highest value at low medium temperatures. The regression analysis showed that hemipteran richness was affected by temperature and plant richness in their habitats.