• Title/Summary/Keyword: Linear detection

Search Result 1,537, Processing Time 0.023 seconds

Reliability of Non-invasive Sonic Tomography for the Detection of Internal Defects in Old, Large Trees of Pinus densiflora Siebold & Zucc. and Ginkgo biloba L. (노거수 내부결함 탐지를 위한 비파괴 음파단층촬영의 신뢰성 분석(소나무·은행나무를 중심으로))

  • Son, Ji-Won;Lee, Gwang-Gyu;An, Yoo-Jin;Shin, Jin-Ho
    • Korean Journal of Environment and Ecology
    • /
    • v.36 no.5
    • /
    • pp.535-549
    • /
    • 2022
  • Damage to forests, such as broken or falling trees, has increased due to the increased intensity and frequency of abnormal climate events, such as strong winds and heavy rains. However, it is difficult to respond to them in advance based on prediction since structural defects such as cavities and bumps inside trees are difficult to identify with a visual inspection. Non-invasive sonic tomography (SoT) is a method of estimating internal defects while minimizing physical damage to trees. Although SoT is effective in diagnosing internal defects, its accuracy varies depending on the species. Therefore, it is necessary to analyze the reliability of its measurement results before applying it in the field. In this study, we measured internal defects in wood by cross-applying destructive resistance micro drilling on old Pinus densifloraSiebold & Zucc. and Ginkgo bilobaL., which are representative tree species in Korea, to verify the reliability of SoT and compared the evaluation results. The t-test for the mean values of the defect measurement between the two groups showed no statistically significant difference in pine trees and some difference in ginkgo trees. Linear regression analysis results showed a positive correlation with an increase in defects in SoT images when the defects in the drill resistance graph increased in both species.

Drone-mounted fruit recognition algorithm and harvesting mechanism for automatic fruit harvesting (자동 과일 수확을 위한 드론 탑재형 과일 인식 알고리즘 및 수확 메커니즘)

  • Joo, Kiyoung;Hwang, Bohyun;Lee, Sangmin;Kim, Byungkyu;Baek, Joong-Hwan
    • Journal of Aerospace System Engineering
    • /
    • v.16 no.1
    • /
    • pp.49-55
    • /
    • 2022
  • The role of drones has been expanded to various fields such as agriculture, construction, and logistics. In particular, agriculture drones are emerging as an effective alternative to solve the problem of labor shortage and reduce the input cost. In this study therefore, we proposed the fruit recognition algorithm and harvesting mechanism for fruit harvesting drone system that can safely harvest fruits at high positions. In the fruit recognition algorithm, we employ "You-Only-Look-Once" which is a deep learning-based object detection algorithm and verify its feasibility by establishing a virtual simulation environment. In addition, we propose the fruit harvesting mechanism which can be operated by a single driving motor. The rotational motion of the motor is converted into a linear motion by the scotch yoke, and the opened gripper moves forward, grips a fruit and rotates it for harvesting. The feasibility of the proposed mechanism is verified by performing Multi-body dynamics analysis.

Simultaneous GC/MS Analyses of Organic acids and Amino acids in Urine using TMS-TFA derivative (TMS-TFA 유도체화를 이용한 소변여지 중 유기산과 아미노산의 GC/MS 동시분석)

  • Yoon, Hye-Ran
    • Analytical Science and Technology
    • /
    • v.19 no.1
    • /
    • pp.107-114
    • /
    • 2006
  • Early diagnosis and medical intervention are critical for the treatment of patients with metabolic disorders. A rapid analytical method was developed for simultaneous quantification of organic acids and amino acids in urine without labor-intensive pre-extraction procedure showing high sensitivity and specificity. A new method consisted of simple two-step trimethylsilyl (TMS)-trifluoroacetyl (TFA) derivatization using GC/MS-selective ion monitoring (SIM). Filter paper urine specimens were dried under nitrogen after being fortified with internal standard (tropate) in a mixture of distilled water and methanol. Methyl orange was added to the residue as indicator reagent. Silyl derivative of carboxylic functional group was followed by trifluoroacetyl derivative for amino functional group. N-methyl-N-(trimethylsilyl-trifluoroacetamide) and N-methyl-bistrifluoroacetamide were consecutively added and heated for 15-20 min at $65^{\circ}C-70^{\circ}C$, for TMS-TFA derivative, respectively. This reactant was analyzed by GC/MS-SIM. Linear dynamic range showed 0.001-50 mg with the detection limit of (S/N=3) 10-200 ng, and the quantification limit of 80-900 ng in urine. Correlation coefficient of regression line was 0.994-0.998. When the method was applied to the patients 'urine, it clearly differentiated the normal from the patient with metabolic disorder. The study showed that the developed method could be the method of choices in rapid and sensitive screening for organic aciduria and amino acidopathy.

Determination of 11-nor-9-carboxy-Δ9-tetrahydrocannabinol (THCCOOH) in human urine by solid-phase extraction and GC/MS (고체상 추출과 GC/MS를 이용한 소변 중 대마 대사체 (THCCOOH) 분석)

  • Cheong, Jae Chul;Kim, Jin Young;In, Moon Kyo;Cheong, Won Jo
    • Analytical Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.441-448
    • /
    • 2006
  • 11-nor-9-carboxy-${\Delta}^9$-tetrahydrocannabinol (THCCOOH) is the major metabolite of tetrahydrocannabinol (THC) which is the primary psychoactive component of marijuana. It is also the target analyte for the discrimination marijuana use. A method using solid-phase extraction (SPE) and gas chromatography/mass spectrometry (GC/MS) was developed for the determination of THCCOOH in human urine. Urine samples (3 mL) were extracted by SPE column with a cation exchange cartridge after basic hydrolysis. The eluents were then evaporated, derivatized, and injected into the GC/MS. The limits of detection (LOD) and quantitation (LOQ) were 0.4 and 1.2 ng/mL, respectively. The response was linear with a correlation coefficient of 0.999 within the concentration range of 1.2 (LLE 1.3)~50.0 ng/mL. The precision and accuracy were stable within 1.20% and the recovery was 83.6~90.7%. The recovery of SPE method was lower than that of liquid-liquid extraction (LLE), but there were no apparent differences in LOD, LOQ, precision and accuracy between the two methods. While SPE method is used as a very effective and rapid procedure for sample pretreatment, and clean extracts, LLE method was not suitable for the extraction procedure of THCCOOH in urine. The applicability of the method was proven by analyzing a urine samples from a marijuana abusers.

Determination of residual novobiocin in livestock products and fisheries products by HPLC (HPLC를 이용한 축·수산 식품 중 잔류 노보비오신의 분석)

  • Lee, Byung Kyu;Lee, Cheol-Woo;Lee, Sang-Ju;Jung, Eun Ha;Lim, Hyun Kyun;Han, Sang Beom
    • Analytical Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.347-354
    • /
    • 2007
  • A simple and rapid high-performance liquid chromatography assay for the determination of residual novobiocin levels in bovine, porcine, chicken, flatfish and japanese eel muscle has been developed and validated. The separation condition for HPLC/UV was optimized with phenyl hexyl ($4.6{\times}150mm$, $5{\mu}m$) column with 10 mM monobasic sodium phosphate buffer (pH 2.5)/acetonitrile (50/50, v/v) as the mobile phase at a flow rate of 1.0 mL/min and detection wavelength was set at 254 nm. Residues were extracted from tissue by blending with methanol and lipid materials were removed with n-hexane. Then, the methanol extract was evaporated to dryness under a nitrogen stream, reconstituted in the mobile phase. Aliquot of the organic extract was decanted and filtered through $0.45{\mu}m$ syringe filter. The $20{\mu}L$ of the resulting solution was injected into the HPLC system. The calibration ranges were $0.5{\sim}5{\mu}g/g$ and calibration curves were linear with coefficients of correlation better than 0.95. The limits of quantification were $0.5{\mu}g/g$ for all muscles. The recoveries of bovine, porcine, chicken, flatfish and japaneseel muscles were 99.8%, 102.4%, 91.0%, 104.0% and 93.0%, respectively. The procedures were validated according to the CODEX guideline, determining specificity, linearity, accuracy, precision, quantitation limit and recovery.

Development of electrochemical biosensor for determination of galactose (4갈락토오즈 측정을 위한 전기화학적 바이오센서 개발)

  • Park, Kap Soo;Cho, Soon Sam;Quan, De;Lee, Jae Seon;Cha, Geun Sig;Nam, Hakhyun
    • Analytical Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.393-399
    • /
    • 2007
  • In principle, the blood galactose level may be determined conveniently with a strip-type biosensor similar to that for glucose. In this study, we describe the development of a disposable galactose biosensor strip for point-of-care testing. The sensor strip is constructed with screen-printed carbon paste electrode (SPCE) and sample amount (< $100{\mu}L$). The developed strip the galactose level in less than 90 s using bienzymatic system of galactose oxidase (GAO) and horseradish peroxidase (HRP). The effects of pH, mediator (1,1-ferrocenedimethanol) concentration, ratio of enzymes, and applied potential were determined preliminarily with glassy carbon electrodes, and optimized further with the strip-type electrodes. The sensor exhibits linear response in the range of $0{\sim}400{\mu}M$ ($r^2$ = 0.997, S/N = 3). Since a low working potential, in principle, the fabricated disposable galactose biosensor has -100 mV (vs. Ag/AgCl), it is applied for the detection of galactose, interfering responses from common interferents such as ascorbic acid, uric acid and acetaminophen could be minimized. The sensor has been used to determine the total galactose level in standard samples with satisfactory reproducibility (CV = 5 %).

Determination of halogen elements in plastics by using combustion ion chromatography (연소IC를 이용한 플라스틱 중 할로겐 물질 정량)

  • Jung, Jae Hak;Kim, Hyo Kyoung;Lee, Yang Hyoung;Lee, Lim Soo;Shin, Jong Keun;Lee, Sang Hak
    • Analytical Science and Technology
    • /
    • v.21 no.4
    • /
    • pp.284-295
    • /
    • 2008
  • For plastics samples, a method using combustion ion chromatography was selected as a method for rapid low-cost analysis to test whether hazardous substances are contained or not. Using combustion ion chromatography, a verification test for F, Cl and Br compounds generated a linear calibration curve with a correlation coefficient of $r^2$ = 0.999~1.000 in the calibration range from 0.5 to 4.0 mg/kg. The detection limits were found to be 0.005~0.024 mg/kg and quantitative limits were found to be 0.014~0.073 mg/kg. The recoveries of combustion ion chromatography using certified reference material (CRM) were found to be 95.5~104.9%. Based on these results, a proficiency test was conducted together with several laboratories in and out of the country, to make comparative analysis of the results from each laboratory. As a result, the data supported the use of combustion ion chromatography as an effective analysis method to deal with regulations for halogen-free electronic products and for other hazardous substances in the electronic products.

Simultaneous determination of amphetamine-like drugs in human urine by SPE and GC/MS (고체상추출과 GC/MS를 이용한 소변 중 암페타민계 마약성분 동시분석법)

  • Cheong, Jae Chul;Kim, Jin Young;In, Moon Kyo;Cheong, Won Jo
    • Analytical Science and Technology
    • /
    • v.21 no.1
    • /
    • pp.41-47
    • /
    • 2008
  • Although liquid-liquid extraction (LLE) method has been used routinely for the analysis of amphetamine-like drugs (amphetamine; AP, methamphetamine; MA, 3,4-methylenedioxyamphetamine; MDA, 3,4-methylenedioxymethamphetamine; MDMA, 3,4-methylenedioxyethylamphetamine; MDEA), a solid-phase extraction (SPE) method, which can be automated, was applied for the simultaneous determination by GC/MS in human urine. Urine samples (3 mL) and 0.1 M phosphate buffer (1 mL, pH 7.0) were extracted by an automated SPE system. The eluent was evaporated, derivatized with trifluoroacetic anhydride (TFAA), and analyzed by GC/MS. The calibration curves was linear with correlation coefficient ($r^2$) above 0.994 in the ranges of 34.0 (AP), 28.0 (MDA)~1000.0 ng/mL for AP, MDA, and 50.0~2000.0 ng/mL for MA, MDMA, and MDEA. The limits of detection ranged from 4.0 to 10.0 ng/mL, and the limits of quantitation ranged from 12.0 to 34.0 ng/mL. The relative recoveries were 93.5~107.7 %. The precisions and accuracies were 1.9~14.8 % and -8.7~14.8 %, respectively. The present method was successfully applied to identify the MA or Ecstasy (MDMA) abusers in exact as well as rapid.

A Study of Changes of Inversion Time Effect on Brain Volume of Normal Volunteers (반전 시간의 변화가 정상인의 뇌 체적에 미치는 영향에 대한 고찰)

  • Kim, Ju Ho;Kim, Seong-Hu;Shin, Hwa Seon;Kim, Ji-Eun;Na, Jae Boem;Park, Kisoo;Choi, Dae Seob
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.4
    • /
    • pp.286-293
    • /
    • 2013
  • Purpose : The objective of this study was to analyze the brain volume according to the brain image of healthy adults in the 20s taken with different inversion time (TI). Materials and Methods: Brain images of healthy adults in the 20 s were acquired using magnetization prepared rapid acquisition gradient echo (MPRAGE) pulse sequence with 1.5 mm thickness of pieces and four inversion times (1100 ms, 1000 ms, 900 ms, 800 ms). The acquired brain images were analyzed to measure the volume of white matter (WM), gray matter (GM), intracranial volume (ICV). The statistical difference according to brain volume and gender was analyzed for each TI. Results: The brain volume calculated using Freesurfer was WM$486.52{\pm}48.64cm^3$ and GM=$646.83{\pm}57.12cm^3$ in mean when adjusted by mean ICV=$1278.94{\pm}154.92cm^3$. Men's brain volume(WM, GM, ICV) was larger than women's brain volume. In the intrarater reliability test, all of the intraclass correlation coefficients were high (0.992 for WM, 0.988 for GM, and 0.997 for ICV). In the repeated measures analysis of variance, GM and ICV did not show a significant difference at each TI (GM p=0.143, ICV p=0.052), but WM showed a significant (p=0.001). In the linear structure relation analysis, all of the Pearson correlation coefficients were high. Conclusion: WM, GM, and ICV indicated high reliability and solid linear structure relations, but WM showed significant differences at each TI. The brain volume of healthy adults in the 20s could be used in comparison with that of patients for reference purposes and to predict the structural change of brain. It would be needed to conduct additional studies to examine the contract, SNR, and lesion detection ability according to variable TI.

A Clinical Study on Binaural Hearing Aid (양이 보청효과에 관한 연구)

  • 김기령;김영명;심윤주
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1978.06a
    • /
    • pp.9.2-9
    • /
    • 1978
  • Monaural and binaural hearing aid performance under quiet and noisy conditions were compared in regard to (1) the degree of hearing impairment, (2) the symmetry of pure tone audiogram, (3) the automatic gain control of the hearing aid. (4) hearing impairement with recruitment and, word discrimination ability. Performance using binaural hearing aids was consistently superior to that using monaural hearing aids. The results were as follows. 1. Speech detection thresholds were enhanced by a mean of 4.25dB when tested with danavox 747 PP stereo type hearing aid and by a mean of 4.12 dB when tested hearing aids connected seperately to the right and left ears. 2. Binaurally tested speech reception thresholds were superior to monaurally tested thresholds by a mean of 3.56dB when tested in quiet and by a mean of 5.56dB when tested in noise. 3. Binaurally tested word discrimination scores were also superior by a mean of 17.09% in quiet and by a mean 19.63% in noise. 4. Both SRT and word discrimination scores were performed best by subjects with moderately-severe impairement. The performance by one mildly impaired subject was the poorest of all performances. The levels of performance order were; moderately-severe loss, severe loss. moderate loss and mild loss. 5. The data obtained using AGC aids when compaired with that of linear amplification show that when AGC aids were worn in both ears. the results were very poor but when one AGC aid was worn in one ear and linear amplification in the other. the results were good. 6. The advantages of binaural hearing aids were obvious even in cases 1) with great diferences in hearing thresholds between right and left ears, 2) when the subject was unable to discriminate words without vision and. 3) when the subject had extreme recruitme t phenomenon.

  • PDF