• 제목/요약/키워드: Linear current source

검색결과 144건 처리시간 0.034초

Dielectric Barrier Discharge for Ultraviolet Light Generation and Its Efficient Driving Inverter Circuit

  • Oleg, Kudryavtsev;Ahmed, Tarek;Nakaoka, Mutsuo
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제4C권3호
    • /
    • pp.101-105
    • /
    • 2004
  • The efficient power MOSFET inverter applied for a simple and low cost power supply is proposed for driving the dielectric barrier discharge (DBD) lamp load. For decades, the DBD phenomenon has been used for ozone gas production in industry. In this research, the ultraviolet and visible light sources utilizing the DBD lamp is considered as the load for solid-state high frequency power supply. It is found that the simple voltage-source single-ended quasi-resonant ZVS inverter with only one active power switch could effectively drive this load with the output power up to 700 W. The pulse density modulation based control scheme for the single-ended quasi-resonant ZVS inverter using a low voltage and high current power MOSFET switching device is proposed to provide a linear power regulation characteristic in the wide range 0-100% of the full power as compared with the conventional control based Royer type parallel resonant inverter type power supplies.

3D Transient Analysis of Linear Induction Motor Using the New Equivalent Magnetic Circuit Network Method

  • Jin Hur;Kang, Gyu-Hong;Hong, Jung-Pyo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제3B권3호
    • /
    • pp.122-127
    • /
    • 2003
  • This paper presents a new time-stepping 3-D analysis method coupled with an external circuit with motion equation for dynamic transient analysis of induction machines. In this method, the magneto-motive force (MMF) generated by induced current is modeled as a passive source in the magnetic equivalent network. So, by using only scalar potential at each node, the method is able to analyze induction machines with faster computation time and less memory requirement than conventional numerical methods. Also, this method is capable of modeling the movement of the mover without the need for re-meshing and analyzing the time harmonics for dynamic characteristics. From comparisons between the results of the analysis and the experiments, it is verified that the proposed method is capable of estimating the torque, harmonic field, etc. as a function of time with superior accuracy.

Performance Improvement of Model Predictive Control Using Control Error Compensation for Power Electronic Converters Based on the Lyapunov Function

  • Du, Guiping;Liu, Zhifei;Du, Fada;Li, Jiajian
    • Journal of Power Electronics
    • /
    • 제17권4호
    • /
    • pp.983-990
    • /
    • 2017
  • This paper proposes a model predictive control based on the discrete Lyapunov function to improve the performance of power electronic converters. The proposed control technique, based on the finite control set model predictive control (FCS-MPC), defines a cost function for the control law which is determined under the Lyapunov stability theorem with a control error compensation. The steady state and dynamic performance of the proposed control strategy has been tested under a single phase AC/DC voltage source rectifier (S-VSR). Experimental results demonstrate that the proposed control strategy not only offers global stability and good robustness but also leads to a high quality sinusoidal current with a reasonably low total harmonic distortion (THD) and a fast dynamic response under linear loads.

LCL 입력 필터를 갖는 PWM 컨버터의 궤환 선형화 제어 (Feedback Linearization Control of PWM Converters with LCL Input Filters)

  • 김동억;이동춘;김흥근
    • 전력전자학회논문지
    • /
    • 제13권1호
    • /
    • pp.55-62
    • /
    • 2008
  • 본 논문에서는 댐핑저항을 사용하지 않고 LCL필터를 사용한 AC/DC PWM 컨버터를 제어하기 위해 다중 루프구조를 갖는 궤환선형화 제어기법을 제안한다. 궤환선형화 기법은 시스템의 비선형성을 제거하여 선형적으로 제어기를 설계할 수 있는 방법으로 우수한 동특성을 얻을 수 있다. 궤환선형화와 더불어 다중루프를 적용하여 컨버터입력전류를 제한함으로써 컨버터의 과전류를 방지할 수 있다. 사용되는 센서의 개수를 줄이기 위해 전원전압과 전원전류가 추정된다. 제시된 제어 알고리즘은 시뮬레이션 및 실험을 통해 그 타당성이 검증된다.

전원전압의 불평형 및 왜곡 보상기능을 갖는 3상 PWM 정류기의 전류제어기 (A Current Controller with the Compensation of the Input Voltage Unbalance and Distortion for Three Phase PWM Rectifier)

  • 신근희;김학원;조관열;임병국
    • 전력전자학회논문지
    • /
    • 제16권6호
    • /
    • pp.594-601
    • /
    • 2011
  • 본 논문은 상용의 전원 전압이 불평형 및 왜곡을 갖는 경우, 전원전압 불평형 및 왜곡 보상기능을 갖는 전류제어기를 제안한다. 일반적으로 3상 전원 시스템은 공통 입력 단자 (Point of Common Coupling)에 단상 부하 및 비선형 부하가 3상 부하와 같이 연결될 수 있어, 종종 불평형과 왜곡이 발생한다. 이런 조건하에서 3상 PWM 정류기를 일반적인 전류 제어기로 제어 할 경우, 3상 PWM 정류기 입력 전류가 불평형 및 왜곡을 갖는 문제가 발생한다. 본 논문에서는 간단한 모델 기반 적응 제어 시스템(Model Reference Adaptive System)기법을 이용하여 3상 입력 전압의 불평형 및 왜곡을 관측하고 전향 보상하는 전류 제어기를 제안하며, 모의해석과 실험을 통하여 그 효용성을 입증한다.

Irradiation of Intense Characteristic X-rays from Weakly Ionized Linear Plasma

  • Sato, Eiichi;Hayasi, Yasuomi;Tanaka, Etsuro;Mori, Hidezo;Kawai, Toshiaki;Takayama, Kazuyoshi;Ido, Hideaki
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.396-399
    • /
    • 2002
  • Intense quasi-monochromatic x-ray irradiation from the linear plasma target is described. The plasma x-ray generator employs a high-voltage power supply, a low-impedance coaxial transmission line, a high-voltage condenser with a capacity of about 200 nF, a turbo-molecular pump, a thyristor pulse generator as a trigger device, and a flash x-ray tube. The high-voltage main condenser is charged up to 55 kV by the power supply, and the electric charges in the condenser are discharged to the tube after triggering the cathode electrode. The x-ray tube is of a demountable triode that is connected to the turbo molecular pump with a pressure of approximately 1 mPa. As electron flows from the cathode electrode are roughly converged to the molybdenum target by the electric field in the tube, the weakly ionized plasma, which consists of metal ions and electrons, forms by the target evaporating. In the present work, the peak tube voltage was almost equal to the initial charging voltage of the main condenser, and the peak current was about 20 kA with a charging voltage of 55 kV. When the charging voltage was increased, the linear plasma x-ray source grew, and the characteristic x-ray intensities of K-series lines increased. The quite sharp lines such as hard x-ray lasers were clearly observed. The quasi-monochromatic radiography was performed by a new film-less computed radiography system.

  • PDF

가정용 연료전지 시스템의 단독운전 시 부하설비의 전압 및 전력품질 평가 (An Assessment on Voltage and Power Quality in Load Facility during the Islanding of Residential Fuel Cell System)

  • 박찬엄;정진수;한운기;임현성;송영상;김춘삼;임덕규
    • 전기학회논문지
    • /
    • 제62권12호
    • /
    • pp.1792-1797
    • /
    • 2013
  • Recently, due to the excessive use of fossil fuels, many studies about the fossil fuels such as solar and fuel cell energy source are progressing. Fuel cell system has high energy conversion efficiency. Also, fuel cell system is environmentally friendly system because the carbon emission is almost not occur. Therefore, the fuel cell system is considered as the core technology of in the fields of the future energy and environmental. Fuel cell system has an effect on distribution power system because another power source of other than large power plants. So, fuel cell system can be reason of power quality in the power system. In this paper, we constructed the system for an assessment on Islanding. The system is composed with power source, Impedance coordination load and linear load, fuel cell system. we are performed assessment on voltage and power quality in customer and the distributed power system during the Islanding of residential fuel cell system. In addition, no change in the impedance of power system, we made a islanding condition only using the actual load, As a variation of generation and load current under islanding, an analysis results based on assessment system showed that the power qualities of distribution system became more aggravation as effect of voltage sag and voltage swell phenomena.

DEVELOPMENT OF LEAD SLOWING DOWN SPECTROMETER FOR ISOTOPIC FISSILE ASSAY

  • Lee, YongDeok;Park, Chang Je;Ahn, Sang Joon;Kim, Ho-Dong
    • Nuclear Engineering and Technology
    • /
    • 제46권6호
    • /
    • pp.837-846
    • /
    • 2014
  • A lead slowing down spectrometer (LSDS) is under development for analysis of isotopic fissile material contents in pyro-processed material, or spent fuel. Many current commercial fissile assay technologies have a limitation in accurate and direct assay of fissile content. However, LSDS is very sensitive in distinguishing fissile fission signals from each isotope. A neutron spectrum analysis was conducted in the spectrometer and the energy resolution was investigated from 0.1eV to 100keV. The spectrum was well shaped in the slowing down energy. The resolution was enough to obtain each fissile from 0.2eV to 1keV. The detector existence in the lead will disturb the source neutron spectrum. It causes a change in resolution and peak amplitude. The intense source neutron production was designed for ~E12 n's/sec to overcome spent fuel background. The detection sensitivity of U238 and Th232 fission chamber was investigated. The first and second layer detectors increase detection efficiency. Thorium also has a threshold property to detect the fast fission neutrons from fissile fission. However, the detection of Th232 is about 76% of that of U238. A linear detection model was set up over the slowing down neutron energy to obtain each fissile material content. The isotopic fissile assay using LSDS is applicable for the optimum design of spent fuel storage to maximize burnup credit and quality assurance of the recycled nuclear material for safety and economics. LSDS technology will contribute to the transparency and credibility of pyro-process using spent fuel, as internationally demanded.

광역학적 암치료를 위한 635nm 다이오드 레이저 시스템 개발 (The Development of 63nm Diode Laser System for Photodynamic Therapy of Cancer)

  • 임현수
    • 대한의용생체공학회:의공학회지
    • /
    • 제24권4호
    • /
    • pp.319-328
    • /
    • 2003
  • 본 논문은 광역학적 암치료를 위한 광원장치의 개발로서 반도체 다이오드 레이저를 이용한 의료용 레이저 시스템의 개발이 목적이다. 광역학적 암 치료에서 이상적인 광원장치는 초점크기를 조절할 수 있으면서 발산하지 않는 균일한 빛과 특정 파장대의 안정성을 갖는 것이다. 본 연구에서는 이러한 점을 고려하여 635nm 파장대의 다이오드 공진기를 이용하였으며, 개발된 레이저 시스템은 제어장치를 사용하여 정교하고 안정적인 출력을 가지도록 하였으며, 시스템은 사용자의 편리성을 고려하여 소형화하였다. 다이오드 레이저시스템의 펄스 형태의 발진모드에서는 초기의 돌입전류에 의해 공진기를 파손시킬 수 있으므로 본 연구에서는 이러한 현상을 회로적으로 보완하여 msec 단위로 on/off 할 경우에도 공진기에 전혀 손상을 입히지 않도록 설계를 하였다. 임상의가 편리하게 방사시간을 설정하고, 연속출력. 펄스. 버스트 펄스, 슈퍼펄스를 방사할 수 있도록 고안하여. 다양한 암조직의 상태에 따라 치료할 수 있도록 구현하였다. 실험결과 레이저의 출력은 입력전류와 시간에 따라 10mW에서 300mW 까지 선형적으로 증가함을 보였다. 개발된 광역학적 레이저 시스템은 고속제어가 가능하고 정 전류 제어와 효과적인 냉각 제어를 통해 안정적으로 정확하게 출력할 수 있었다.

Wind Energy Interface to Grid with Load Compensation by Diode Clamped Multilevel Inverters

  • Samuel, Paulson;Naik, M. Kishore;Gupta, Rajesh;Chandra, Dinesh
    • Journal of Power Electronics
    • /
    • 제14권2호
    • /
    • pp.271-281
    • /
    • 2014
  • Fluctuating wind conditions necessitate the use of a variable speed wind turbine (VSWT) with a AC/DC/AC converter scheme in order to harvest the maximum power from the wind and to decouple the synchronous generator voltage and frequency from the grid voltage and frequency. In this paper, a combination of a three phase diode bridge rectifier (DBR) and a modified topology of the diode clamped multilevel inverter (DCMLI) has been considered as an AC/DC/AC converter. A control strategy has been proposed for the DCMLI to achieve the objective of grid interface of a wind power system together with local load compensation. A novel fixed frequency current control method is proposed for the DCMLI based on the level shifted multi carrier PWM for achieving the required control objectives with equal and uniform switching frequency operation for better control and thermal management with the modified DCMLI. The condition of the controller gain is derived to ensure the operation of the DCMLI at the fixed frequency of the carrier. The converter current injected into the distribution grid is controlled in accordance with the wind power availability. In addition, load compensation is performed as an added facility in order to free the source currents being fed from the grid of harmonic distortion, unbalance and a low power factor even though the load may be unbalanced, non-linear and of a poor power factor. The results are validated using PSCAD/EMTDC simulation studies.