• Title/Summary/Keyword: Linear Time-varying

Search Result 528, Processing Time 0.025 seconds

Biphasic Release Characteristics of Dual Drug-loaded Alginate Beads

  • Lee, Beom-Jin;Cui, Jing-Hao;Kim, Tae-Wan;Heo, Min-Young;Kim, Chong-Kook
    • Archives of Pharmacal Research
    • /
    • v.21 no.6
    • /
    • pp.645-650
    • /
    • 1998
  • The dual drug-loaded alginate beads simultaneously containing drug in inner and outer layers were prepared by dropping plain (single-layered) alginate beads into $CaCl_2$ solution. The release characteristics were evaluated in simulated gastric fluid for 2 h followed by intestinal fluids thereafter for 12 h. The surface morphology and cross section of dual drug-loaded alginate beads was also investigated using scanning electron microscope (SEM). The poorlv water-soluble ibuprofen was chosen as a model drug. The surface of single-layered and dual drug-loaded alginate beads showed very crude and roughness, showing aggregated particles, surface cracks and rough crystals. The thickness of dual drug-loaded alginate beads surrounded by outer layer was ranged from about 57 to 329mcm. The distinct chasm between inner and outer layers was also observed. In case of single-layered alginate bead, the drug was not released in gastric fluid but was largely released in intestinal fluid. However, the release rate decreased as the reinforcing $Eudragit^{\circledR}$ polymer contents increased. When the plasticizers were added into polymer, the release rate largely decreased. The release rate of dual drug-loaded alginate beads was stable in gastric fluid for 2 h but largely increased when switched in intestinal fluid. The drug linearly released for 4 h followed by another linear release thereafter, showing a distinct biphasic release characteristics. There was a difference in the release profiles between single-layered and dual drug-loaded alginate beads due to their structural shape. However, this biphasic release profiles were modified by varying formulation compositions of inner and outer layer of alginate beads. The release rate of dual drug-loaded alginate beads slightly decreased when the outer layer was reinforced with $Eudragit^{\circledR}$ RS1OO polymers. In case of dual drug-loaded alginate beads with polymer-reinforced outer layer only, the initial amount of druc released was low but the initial release rate (slope) was higher due to more swellable inner cores when compared to polymer-reinforced inner cores. The current dual drug-loaded alginate beads may be used to deliver the drugs in a time dependent manner.

  • PDF

Kinetic Investigation of CO2-CH4 Reaction over Ni/La2O3 Catalyst using Photoacoustic Spectroscopy

  • Oh, Hyun-Jin;Kang, Jin-Gyu;Heo, Eil;Lee, Sung-Han;Choi, Joong-Gill
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.9
    • /
    • pp.2615-2620
    • /
    • 2014
  • Ni/$La_2O_3$ with a high dispersion was prepared by reduction of $La_2O_3$ perovskite oxide to examine the catalytic activity for the $CO_2-CH_4$ reaction. The Ni/$La_2O_3$ catalyst was found to be highly active for the reaction. The ratios of $H_2$/CO were measured in a flow of the reaction mixture containing $CO_2/CH_4$/Ar using an on-line gas chromatography system operated at 1 atm and found to be varied with temperature between 0.66 and 1 in the temperature range of $500-800^{\circ}C$. A kinetic study of the catalytic reaction was performed in a static reactor at 40 Torr total pressure of $CO_2/CH_4/N_2$ by using a photoacoustic spectroscopy technique. The $CO_2$ photoacoustic signal varying with the concentration of $CO_2$ during the catalytic reaction was recorded as a function of time. Rates of $CO_2$ disappearance in the temperature range of $550-700^{\circ}C$ were obtained from the changes in the $CO_2$ photoacoustic signal at early reaction stage. The plot of ln rate vs. 1/T showed linear lines below and above $610^{\circ}C$. Apparent activation energies were determined to be 10.4 kcal/mol in the temperature range of $550-610^{\circ}C$ and 14.6 kcal/mol in the temperature range of $610-700^{\circ}C$. From the initial rates measured at $640^{\circ}C$ under various partial pressures of $CO_2$ and $CH_4$, the reaction orders were determined to be 0.43 with respect to $CO_2$ and 0.33 with respect to $CH_4$. The kinetic results were compared with those reported previously and used to infer a reaction mechanism for the Ni/$La_2O_3$-catalyzed $CO_2-CH_4$ reaction.

Three-Dimensional Vibration Analysis of Solid and Hollow Hemispheres Having Varying Thickness (변두께를 갖는 두꺼운 반구형 쉘과 반구헝체의 3차원적 진동해석)

  • 심현주;장경호;강재훈
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.16 no.2
    • /
    • pp.197-206
    • /
    • 2003
  • A three-dimensional (3-D) method of analysis is presented for determining the free vibration frequencies and mode shapes of solid and hollow hemispherical shells of revolution of arbitrary wall thickness having arbitrary constraints on their boundaries. Unlike conventional shell theories, which are mathematically two-dimensional (2-D), the present method is based upon the 3-D dynamic equations of elasticity. Displacement components μ/sub Φ/, μ/sub z/, and μ/sub θ/ in the meridional, normal, and circumferential directions, respectively, are taken to be sinusoidal in time, periodic in θ, and algebraic polynomials in the Φ and z directions. Potential (strain) and kinetic energies of the hemispherical shells are formulated, and the Ritz method is used to solve the eigenvalue problem, thus yielding upper bound values of the frequencies obtained by minimizing the frequencies. As the degree of the polynomials is increased, frequencies converge to the exact values. Novel numerical results are presented for solid and hollow hemispheres with linear thickness variation. The effect on frequencies of a small axial conical hole is also discussed. Comparisons are made for the frequencies of completely free, thick hemispherical shells with uniform thickness from the present 3-D Ritz solutions and other 3-D finite element ones.

Dynamic Behavior Modelling of Augmented Objects with Haptic Interaction (햅틱 상호작용에 의한 증강 객체의 동적 움직임 모델링)

  • Lee, Seonho;Chun, Junchul
    • Journal of Internet Computing and Services
    • /
    • v.15 no.1
    • /
    • pp.171-178
    • /
    • 2014
  • This paper presents dynamic modelling of a virtual object in augmented reality environments when external forces are applied to the object in real-time fashion. In order to simulate a natural behavior of the object we employ the theory of Newtonian physics to construct motion equation of the object according to the varying external forces applied to the AR object. In dynamic modelling process, the physical interaction is taken placed between the augmented object and the physical object such as a haptic input device and the external forces are transferred to the object. The intrinsic properties of the augmented object are either rigid or elastically deformable (non-rigid) model. In case of the rigid object, the dynamic motion of the object is simulated when the augmented object is collided with by the haptic stick by considering linear momentum or angular momentum. In the case of the non-rigid object, the physics-based simulation approach is adopted since the elastically deformable models respond in a natural way to the external or internal forces and constraints. Depending on the characteristics of force caused by a user through a haptic interface and model's intrinsic properties, the virtual elastic object in AR is deformed naturally. In the simulation, we exploit standard mass-spring damper differential equation so called Newton's second law of motion to model deformable objects. From the experiments, we can successfully visualize the behavior of a virtual objects in AR based on the theorem of physics when the haptic device interact with the rigid or non-rigid virtual object.

Current Status of the KMTNet Active Nuclei Variability Survey (KANVaS)

  • Kim, Joonho;Karouzos, Marios;Im, Myungshin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.1
    • /
    • pp.54.1-54.1
    • /
    • 2016
  • Multi-wavelength variability is a staple of active galactic nuclei (AGN). Optical variability probes the nature of the central engine of AGN at smaller linear scales than conventional imaging and spectroscopic techniques. Previous studies have shown that optical variability is more prevalent at longer timescales and at shorter wavelengths. Intra-night variability can be explained through the damped random walk model but small samples and inhomogeneous data have made constraining this model hard. To understand the properties and physical mechanism of intra-night optical variability, we are performing the KMTNet Active Nuclei Variability Survey (KANVaS). Using KMTNet, we aim to study the intra-night variability of ~1000 AGN at a magnitude depth of ~19mag in R band over a total area of ${\sim}24deg^2$ on the sky. Test data in the COSMOS, XMM-LSS, and S82-2 fields was obtained over 4, 6, and 8 nights respectively during 2015, in B, V, R, and I bands. Each night was composed of 5-13 epoch with ~30 min cadence and 80-120 sec exposure times. As a pilot study, we analyzed data in the COSMOS field where we reach a magnitude depth of ~19.5 in R band (at S/N~100) with seeing varying between 1.5-2.0 arcsec. We used the Chandra-COSMOS catalog to identify 166 AGNs among 549 AGNs at B<23. We performed differential photometry between the selected AGN and nearby stars, achieving photometric uncertainty ~0.01mag. We employ various standard time-series analysis tools to identify variable AGN, including the chi-square test. Preliminarily results indicate that intra-night variability is found for ~17%, 17%, 8% and 7% of all X-ray selected AGN in the B, V, R, and I band, respectively. The majority of the identified variable AGN are classified as Type 1 AGN, with only a handful of Type 2 AGN showing evidence for variability. The work done so far confirms there are more variable AGN at shorter wavelengths and that intra-night variability most likely originates in the accretion disk of these objects. We will briefly discuss the quality of the data, challenges we encountered, solutions we employed for this work, and our updated future plans.

  • PDF

평행식 진동탄환 암거 천공기의 연구 (IV)(V)-실기 설계 제작 및 보장실험-Development of Balanced-Type Oscillating Mole Drainer(IV)(V)

  • 김용환;이승규;서상용
    • Journal of Biosystems Engineering
    • /
    • v.2 no.1
    • /
    • pp.7-24
    • /
    • 1977
  • This paper is the forth and fifth one of the study on balanced type oscillating mole drainer. In the light of the results from previous reports about the model tests, some design criteria were established and a prototype machine was set up for experimental purpose. Motion characteristics and functionof the each parts of the machine were checked and analyzed. After that, performance tests of the prototype machine were carried out in thefield. Obtained results are summarized as follows ; 1. Ten centimeter of the bullet diameter was determined so as to be able to attach it to the tractors with capacity of 30 PS to 40 PS. 2. To maintain the balance between the moments of the front shank and rear shank, the oscillating amplitude of the rear bullet was determined to be larger than that of the front bullet. At the same time , the oscillating direction of the rear bullet was designed with the inclines of ten to thirty degrees. 3. An octagonal dynamo transduced was developed for measuring the compressive force of the upper link is measuring the draft force of the machine. Acceptable linear relationship between forces and strain responses from O.D.T. was obtained. 4. Analysing the balancing mechanism of the acting part of the machine , it was found that the total draft force of the machine was equal to the difference between the sum of the draft force produced from the right and left side bending moments of the lower drawber and the compressive force on the upper link. 5. There are acceptable linear relationship between the strain and twisting moment by driving shaft, and between strain and shank moment. Above results enable us to carry out the field experiment with prototype machine. 6. When the test machine was used in the field, it was possible to reduce the oscillating acceleration by forty percent in average as compared it with the single bullet mole drainer. 7. When the test machine was used under the oscillating condition, the dratt torce was reduced by 27 percent to 59 percent as compared it with the test machine under non-oscillating condition, while the draft force was increased by 7 percent to 20 percent as compared it with the mole drainer having oscillating single bullet. The reasoning behind this fact was considered as the resistance force due to the rear shank and bullet. 8. As the amplitude and frequency of the bullet were increased, the torque was increased accordingly. This tendency could be varied with the various characteristics of the given soils. And the larger frequency and amplitute, the more increasing oscil\ulcornerlating power but decreasing draft brce were needed, and draft force was increased as the velocity was increased.9. When the amplitude of the rear bullet was designed to be larger than that of the front bullet, the minimum value of the moment was lowered and oscillating acceleration was reduced. And when the oscillating direction of the rear bullet was declined back\ulcornerwards, oscillating acceleration was increased along with the increasing angle of decli\ulcornernation. When the test machine was operated in high speed, the difference between maximum moments and minimum ones became narrow. This varying magnitude of moments appeared on the moment oscillogram seems to be correlated to the oscillating acceleration and draft force. 10. From the analysis of variance, it was found that those factors such as frequency, amplitude, and operating velocity significantly affected in the oscillating acceleration, the draft resistance, the torque, the moment, and the total power required. And interaction between frequency and amplitude affected in the oscillating acceleration. 11. Within the given situation of this study, the most preferable operating conditions of the test machine were 7 Hz in oscillating frequency, 0.54 m/sec in operating velocity, and 39.1 mm in oscillating amplitude of front and rear bullets. However, it is necessary to select the proper frequency and magnitude of oscillation depending on the soil properties of the field in which the mole drainer is practiced by use of a bal1nced type oscillating mole drainer. 12. It is recommended that a comparative study of the mole drainers would be performed in the near future using two separate balanced oscillating bullet with the one which is operated by oscillating the movable bullet in a single cylinder or other balanced type which may be single oscillating bullet with spring, damper or balancing weight, and that of thing. To expand the applicability of the balanced type oscillating mole drainer in practical use, it is suggested to develop a new mechanism which perform mole drain with vinyl pipe or filling material such as rice hull.

  • PDF

REPORT OF EXPERIENCE WITH KIMURA'S DISEASE (기무라씨 질환, 5 예 보고)

  • Seel David J.;Park Yoon-Kyu;Lee Kwang-Min
    • Korean Journal of Head & Neck Oncology
    • /
    • v.5 no.1
    • /
    • pp.39-46
    • /
    • 1989
  • Kimura's Disease is a chronic inflammatory and proliferative condition producing subcutaneous masses especially in the head and neck area. This report of our experience with 5 patients with this disease is the first in the Korean surgical literature. Kimura's Disease is thought to be part of the larger spectrum of the entity known as angiolymphoid hyperplasia with eosinophilia (ALHE). It is characterized pathologically by hyperplastic lymphoid follicles, eosinophilic infiltration, and vase 비 ar proliferation. It produces masses which are most common in the area of the parotid, submandibular gland and upper neck. These masses occupy the subcutaneous tissues but also extend into salivary tissue and into upper neck nodes. One of our patients had masses in the groin. The tumors are extremely vascular due to the presence of new proliferative vessels and sinusoids. The average age of our 5 patients was 35, but all but one case were younger than 38 years of age. The male: female ratio was 3 : 2, and the average duration of symptoms was 5,2years. All patients had peripheral blood eosinophilia. All had multiple masses, sometimes symmetrical. The management was surgery alone in one case, surgery and steroids in one case, surgery and radiotherapy in two cases, and all three modalities in one case. The relationship of this entity to ALHE and our experience in the management of this disease are presented. A clinicopathological discrepancy alerted us to the existence of Kimura's Disease. A nineteen-year old male presented with subcutaneous masses over both mastoid areas present for 3 years (Case III). When biopsy on each side was reported as 'eosinophilic granuloma' we submitted the slides to an internationally expert pathologist. Symmetrically occurring tumors in the peri-parotid subcutaneous areas did not fit any category of neoplasm or granuloma known to us. The diagnosis, made by Dr. Gist Fan at the Ochsner Clinic, was Kimura's Disease. We found two additional cases in a review of soft tissue eosinophilic granuloma previously reported at Presbyterian Medical Center, and since then have diagnosed two new cases. These five cases constitute the basis for this, the largest series to be reported in Korea. These vascular, tumor-like lesions of the skin, subcutaneous areas and subjacent structures of the head and neck have been a variety of names, such as angiolymphoid hyperplasia with eosinophilia, eosinophilic hyperplastic lymphogranuloma, angioblastic lymphoid hyperplasia with eosinophilia, histioid hemangioma, and epithelioid hemangioma. The history of this disease spectrum dates back to 1937 when Kimm and Szeto (1) reported 7 cases of 'eosinophilic hyperplastic lymphogranuloma' in the Proceedings of the Chinese Medical Journal. In 1948 Kimura and his associates(2) reported additional cases in Japan under the title 'On the unusual granulation combined with hyperplastic changes of lymphatic tissue.' From then until 1966 several hundred cases were reported in China and Japan. The first report from the West was by Wells and Whimster(3) in the British Journal of Dermatology, in 1969. These authors coined the term, angiolymphoid hyperplasia with eosinophilia (ALHE). Since that time a debate has ensued as to whether Kimura's Disease and ALHE are distinct entities, or whether Kimura's is part of the larger spectrum of ALHE, perhaps a later or advanced phase. From the clinical perspective, surgeons should be aware of the diagnosis of Kimura's Disease not only as part of the differential diagnosis of head and neck tumors but also because these lesions are indolent, and generally require conservative surgical removal as part of the management program. CASE I. A 37-year-old female company employee presented in August 1982 with submental swelling of 12 years' duration and with inguinal swelling of 7 years' duration. The submental mass measured 5x5cm. and the inguinal mass was 8x4cm. in size. Peripheral eosinophilia varying from 14% to 40% was found. On August 20, 1982, the submental mass was removed and a superficial groin dissection was done. In May 1983 an intraoral lesion of the palate was removed. The patient is free of disease. CASE II. A 23-year-old unemployed man visited this hospital for the first time in July, 1984, with swelling of the right cheek present for 6 years. The mass was soft and ill-defined but measured 10x20cm. and extended from the submandibular upper neck to the zygomatic arch, and from the mastoid to the cheek, over the parotid gland. Eosinophilia varying from 27% to 29% was noted in the peripheral blood. On March 21, 1986, the lesion was resected. The procedure comprised an extended superficial parotidectomy from the temporalis fascia to the upper neck. Post-operatively radiotherapy 3000 rad tissue dose was administered using the 6 MeV linear accelerator. The patient remains free of disease. CASE III. A 19-year-old student came to the clinic with masses over both mastoid areas, present 3 years. On the right there were two adjacent lesions, one over the mastoid, the other in the upper jugular level of the neck. On the left it was a single mass over the mastoid. Eosinophilia varied from 13 to 32% in the peripheral blood, and 11.6% in the bone marrow. Incisional biopsy revealed 'eosinophilic granuloma' and a trial of predisolone was employed. The mass increased in size so a small dose of radiation (600 rads) was used, with substantial regression,. The lesion on the left was excised and follwed by 1000 rads radiotherapy. Finally recurrent tumor on the right side was removed on November 5, 1985. The patient remains free of disease. CASE N. A 29-year-old local merchant had had swelling of both upper necks since childhood. At the time of his first visit on March 17, 1986, the right submandibular mass measured 5x3.5cm. and the ,right upper neck and parotid tail mass measured 2.5cm. On the left there were masses in the upper neck, the largest of which measured 2.5cm, and of the parotid tail, 2.0cm. in size.(See Fig. 1) Peripheral eosinophilia of 39% was recorded. Left side partial parotidectomy and resection of the upper neck and subdigstric mases was done on May 2, 1986. The mass involving the right parotid tail and upper neck nodes was removed on Angust 7,1986. Postoperatively the patient was placed on prednisolone 30 mg. per day. No definite masses are palpable. CASE V. A 66-year-old housewife informed us, at the time of her first visit in May, 1986, that she had had multiple neck masses since 10 years ago. On the right side there was a 2.5cm. subcutaneous mass of the upper neck, over the upper jugular chain. On the left there was a 9x4.5cm. mass involving the entire parotid, the post-auricular area and the upper neck. A third mass presented in the submental area and measured 3.5cm. (See Fig. 2) Eosinophilia of 51% was noted in the peripheral blood. partial excision of the left upper neck lesion and complete excision of the submental mass were performed on june 6, 1986. post-operatively she was placed on 20 mg. of prednisolone daily, but when the mass re-grew after two months she was referred to Radiation Therapy for a 2500 rad course of treatment. A barely palpable thickening remains.

  • PDF

Dosimetric Effect on Selectable Optimization Parameters of Volumatric Modulated Arc Therapy (선택적 최적화 변수(Selectable Optimization Parameters)에 따른 부피적조절회전방사선치료(VMAT)의 선량학적 영향)

  • Jung, Jae-Yong;Shin, Yong-Joo;Sohn, Seung-Chang;Kim, Yeon-Rae;Min, Jung-Wan;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.23 no.1
    • /
    • pp.15-25
    • /
    • 2012
  • The aim of this study is to evaluate plan quality and dose accuracy for Volumetric Modulated Arc Therapy (VMAT) on the TG-119 and is to investigate the effects on variation of the selectable optimization parameters of VMAT. VMAT treatment planning was implemented on a Varian iX linear accelerator with ARIA record and verify system (Varian Mecical System Palo Alto, CA) and Oncentra MasterPlan treatment planning system (Nucletron BV, Veenendaal, Netherlands). Plan quality and dosimetric accuracy were evaluated by effect of varying a number of arc, gantry spacing and delivery time for the test geometries provided in TG-119. Plan quality for the target and OAR was evaluated by the mean value and the standard deviation of the Dose Volume Histograms (DVHs). The ionization chamber and $Delta^{4PT}$ bi-planar diode array were used for the dose evaluation. For treatment planning evaluation, all structure sets closed to the goals in the case of single arc, except for the C-shape (hard), and all structure sets achieved the goals in the case of dual arc, except for C-shape (hard). For the variation of a number of arc, the simple structure such as a prostate did not have the difference between single arc and dual arc, whereas the complex structure such as a head and neck showed a superior result in the case of dual arc. The dose distribution with gantry spacing of $4^{\circ}$ was shown better plan quality than the gantry spacing of $6^{\circ}$, but was similar results compared with gantry spacing of $2^{\circ}$. For the verification of dose accuracy with single arc and dual arc, the mean value of a relative error between measured and calculated value were within 3% and 4% for point dose and confidence limit values, respectively. For the verification on dose accuracy with the gantry intervals of $2^{\circ}$, $4^{\circ}$ and $6^{\circ}$, the mean values of relative error were within 3% and 5% for point dose and confidence limit values, respectively. In the verification of dose distribution with $Delta^{4PT}$ bi-planar diode array, gamma passing rate was $98.72{\pm}1.52%$ and $98.3{\pm}1.5%$ for single arc and dual arc, respectively. The confidence limit values were within 4%. The smaller the gantry spacing, the more accuracy results were shown. In this study, we performed the VMAT QA based on TG-119 procedure, and demonstrated that all structure sets were satisfied with acceptance criteria. And also, the results for the selective optimization variables informed the importance of selection for the suitable variables according to the clinical cases.