• 제목/요약/키워드: Linear Scale

검색결과 1,484건 처리시간 0.031초

연취급 근로자들의 혈중 ZPP 농도 선별기준에 따른 정확도의 변화 (The change of validity of blood zinc protoporphyrin test by different cut-off level in lead workers)

  • 김용배;안현철;황보영;리갑수;이성수;안규동;이병국
    • Journal of Preventive Medicine and Public Health
    • /
    • 제30권4호
    • /
    • pp.741-751
    • /
    • 1997
  • Measurement of blood lead (PbB) and blood zinc protoporphyrin (ZPP) are most common biological indices to identify the individual at risk for excess or the health sequences by lead exposure. Because PbB is known most important and reliable index of lead exposure, PbB is often regarded as a gold standard to detect lead exposure. But in Korea PbB is a secondary test item of detailed health check-up with positive finding of screening test in most occasion. Our lead standard requires all lead workers to take annual heath-check twice a year for investigation of their health effect due to lead exposure. Blood ZPP is one of most important index to detect high lead absorption in lead workers as a screening test. Measurement of blood ZPP is known ,well to correlate with PbB in steady state of exposure in most lead workers and is often used as a primary screening test to detect high lead absorption of lead workers with the advantage of simplicity, easiness, portability and low cost. The current cut-off criteria of blood ZPP for further detailed health check-up is $100{\mu}g/d\ell$ which is supposed to match the level of $40{\mu}g/d\ell$ of PbB according to our standard. Authors tried to investigate the validity of current criteria of cut-off level $(100{\mu}g/d\ell)$ of blood ZPP and possible another better cut-off level of it to detect the lead workers whose PbB level over $40{\mu}g/d\ell$. The subjects in our study were 212 male workers in three small scale storage battery industries. Blood ZPP, PbB and hemoglobin (Hb) were selected as the indices of lead exposure. The results were as follows. 1. The mean of blood ZPP, PbB and Hb in lead workers were $79.5{\pm}46.7{\mu}g/d\ell,\;38.7{\pm}15.1{\mu}g/d\ell,\;and\;14.8{\pm}1.2g/d\ell$, respectively. There were significant differences in blood ZPP, PbB and Hb by industry (P<0.01). 2. The percents of lead workers whose blood ZPP were above $100{\mu}g/d\ell$ in the group of work duration below 1, 1-4, 5-9 and above 10 years were 8.6%, 17.2%, 47.6%, and 50.0%, respectively. The percents of lead workers whose PbB were above $40{\mu}g/d\ell$ in those were 31.4%, 40.4%, 71.4%, and 86.4%, respectively. 3. The percents of lead workers whose PbB were below $40{\mu}g/d\ell$, $40-59{\mu}g/d\ell$ and above $60{\mu}g/d\ell$ were 54.7%, 34.9% and 10.4%, respectively. Those of lead workers whose blood ZPP were below $100{\mu}g/d\ell$, $100-149{\mu}g/d\ell$ and above $150{\mu}g/d\ell$ were 79.2%, 13.7% and 7.1%, respectively. 4. Simple linear regression of PbB on blood ZPP was statistically significant (P<0.01) and as PbB was $40{\mu}g/d\ell$, blood ZPP was $82.1{\mu}g/d\ell$. 5. While the highest sensitivity and specificity of blood ZPP test to detect lead workers with PbB eve. $40{\mu}g/d\ell$ were observed in the cut-off level of $50{\mu}g/d\ell$ and $100{\mu}g/d\ell$ of blood ZPP, respectively, the highest validity (sensitivity+specificity) of blood ZPP to detect lead workers with PbB over $40{\mu}g/d\ell$ was observed in the cut-off level of around $70{\mu}g/d\ell$ of blood ZPP. But even with optimal cut-off level of around $70{\mu}g/d\ell$ of blood ZPP, still 25.0% of false negative and 20.7% false positive lead workers were found. As the result of this study, it was suggested that reconsideration of current blood ZPP cut-off of our lead standard from $100{\mu}g/d\ell$ to somewhat lower level such as around $70{\mu}g/d\ell$ and the inclusion of PbB measurement as a primary screening test for lead workers was highly recommended for the effective prevention of lead workers.

  • PDF

에스자결장암에서 근치적 절졔술 후 방사선 치료의 역할 (The Role of Adjuvant Postoperative Radiotherapy in Curative Resectable Sigmoid Colon Carcinoma)

  • 박원;성진실;금기창;서창옥;이상욱;임지훈;민진식;노재경;김주항;정현철;이강규;김귀언
    • Radiation Oncology Journal
    • /
    • 제15권4호
    • /
    • pp.339-348
    • /
    • 1997
  • 목적 : 에스자결장암으로 진단 받고 근치적 절제술이 시행된 환자를 대상으로 수술후 보조 요법으로서 방사선 치료의 역할을 평가하고자 하며, 방사선 치료를 받은 군과 받지 않은 군의 재발 양상과 생존율을 비교하고, 방사선 치료를 추가함으로써 국소 제어율이나 생존율의 향상을 기대 할 수 있는 요인을 분석해 보고자 하였다. 대상 및 방법 : 1988년 1월부터 1993년 12월까지 연세 의료원에서 에스자결장암이라고 진단 받고 근치적 절제술을 시행받은 93례를 대상으로 하였다. 근치적 수술후 방사선 추가 여부에 따라 두 군으로 분류하였다. 에스자결장암으로 근치적 수술만 시행된 43례는 수술 단독군이라 하였고 수술후 보조 요법으로 방사선 치료가 추가된 50례는 방사선 치료군으로 분류하였다. 방사선 치료군에서 방사선 치료는 수술 후 1-2개월후부터 시작하였는데 원발 병소가 있었던 부위에 적어도 5cm의 여유를 두고 4 MV나 10 MV 선형 가속기를 이용하여 하루에 1.8Gy씩 50.4Gy-61Gy까지 조사하였다. 항암화학요법은 5-Fluorouracil을 이용하여 32례에서 시행하였는데 항암화학요법을 받은 예가 두 군간 의의있는 차이는 없었다. 결과 : 5년 국소 제어율과 무병 생존율이 각각 $85.1\%,\;68.5\%$였다. 수술 단독군과 방사선 치료군의 국소 제어율은 각각 $75.2\%$$91.7\%$였다. MAC Stage C3에서 방사선 치료군이 수술 단독군보다 국소 제어율과 무병 생존율이 높았다(P=0.01, p=0.06). MAC Stage B3에서 방사선 치료군이 수술 단독군보다 국소 제어율이 더 높았으나 통계적 의의는 없었다. 특히, 조직학적으로 원발 병소가 결장 주위를 넘어 다른 조직에 침윤이 있는 경우(Stage T4), 수술 단독군보다 방사선 치료군의 국소 제어율이 더 높았다. 결론 : 에스자결장암에서 근치적 절제술후 MAC Stgae B3, C3 -특히, 주위 조직에 조직학적으로 침윤이 있는 경우-에서 방사선 치료를 추가함으로써 국소 제어율을 높이고, 생존율의 향상을 기대해 볼 수 있겠다. 그리고 에스자결장암에서 근치적 수술후 방사선 치료의 역할을 보다 명확하게 규명하기 위해서는 향후 전향적 연구가 필요하리라 생각된다.

  • PDF

전주 및 순창지역에 분포하는 엽리상 화강암류의 성인에 대한 연구 (II) - Sr 및 Nd 동위원소적 특성을 중심으로 - (Petrogenetic Study on the Foliated Granitoids in the Chonju and the Sunchang area (II) - In the Light of Sr and Nd Isotopic Properites -)

  • 나춘기;이인성;정재일
    • 자원환경지질
    • /
    • 제30권3호
    • /
    • pp.249-262
    • /
    • 1997
  • The Sr and Nd isotopic compositions of two foliated granitic plutons located in the Chonju and Sunchang area were determined in order to reconfirm the intrusion ages of granitoids and to study the sources of granitic magmas. The best defined Rb-Sr isochron for the whole rock samples of the Chonju foliated granite (CFGR) give an age of $284{\pm}12Ma$, suggesting early Permian intrusion age. In contrast, the whole rock Rb-Sr data of the Sunchang foliated granite (SFGR) scatter widely on the isochron diagram with very little variation in the $^{87}Rb/^{86}Sr$ ratios and, therefore, yield no reliable age information. Futhermore they show the concordance of mineral and whole rock Rb-Sr isochron and divide into two linear groups with roughly the same slopes and significantly different $^{87}Sr/^{86}Sr$ ratios, indicating some kind of Rb-Sr distortion in whole rock scale and a difference in source material and/or magmatic evolution between two subsets. The reconstructed isochrons of 243 Ma, which was defined from the proposed data by the omission of one sample point with significantly higher $^{87}Rb/^{86}Sr$ ratio than the others, and 252 Ma, from the combined data of it and some of this study, strongly suggest the possibility that the SFGR was intruded appreciably earlier than had previously been proposed, although the reliability of these ages still questionable owing to high scatter of data points and, therefore, further study is necessary. All mineral isochrons for the investigated granites show the Jurassic to early Cretaceous thermal episode ranging from 160 Ma to 120 Ma Their corresponding initial $^{87}Sr/^{86}Sr$ ratios correlate well with their whole rock data, indicating that the mineral Rb-Sr system of the investigated granites was redistributed by the postmagmatic thermal event during Jurassic to early Cretaceous. The initial ${\varepsilon}Sr$ values for the CFGR (64.27 to 94.81) tend to be significantly lower than those for the SFGR (125.43 to 167.09). Thus it is likely that there is a marked difference in the magma source characteristics between the CFGR and the SFGR, although the possibility of an isotopic resetting event giving rise to a high apparent initial ${\varepsilon}Sr$ in the SFGR can not be ruled out. In contrast to ${\varepsilon}Sr$, both batholiths show a highly resticted and negative values of initial ${\varepsilon}Nd$, which is -14.73 to -19.53 with an average $-16.13{\pm}1.47$ in the CFGR and -14.78 to -18.59 with an average $-17.17{\pm}1.01$ in the SFGR. The highly negative initial ${\varepsilon}Nd$ values in the investigated granitoids strongly suggest that large amounts of recycled old continental components have taken part in their evolution. Furthermore, this highly resticted variation in ${\varepsilon}Nd$ is significant because it requires that the old crustal source material, from which the granitoid-producing melts were generated, should have a reasonably uniform Nd isotopic composition and also quit similar age. Calculated T2DM model ages give an average of $1.83{\pm}0.25Ga$ for CFGR and $1.96{\pm}0.19Ga$ for SFGR, suggesting the importance of a mid-Proterozoic episode for the genesis of two foliated granites. Although it is not possible to determine precisely the source rock compositions for the investigated foliatic granites, the Sr-Nd isotopic evidences indicate that midcrustal or less probably, a lower crustal granulitic source could be the most likely candidate.

  • PDF

특발성 파킨슨병 환자의 임상척도에 따른 심박변이도의 변화에 대한 연구 (Clinical Study of Heart Rate Variability on Patients with Idiopathic Parkinson's Disease according to Clinical Scale(Hoehn-Yahr stage, UPDRS))

  • 박상민;이상훈;정지철;김건형;박히준;임사비나;장대일;이윤호
    • Journal of Acupuncture Research
    • /
    • 제22권3호
    • /
    • pp.137-144
    • /
    • 2005
  • 본 저자는 2004년 3월 9일부터 2004년 5월15일까지 경희의료원 침구과 외래를 내원한 특발성 파킨슨병 환자를 대상으로 하여 파킨슨병 증상의 호전도를 판단하는 임상척도인 H-Y stage에 따른 HRV를 관찰한 결과 다음과 같은 결론을 얻었다. 1. 시간영역분석에서 H-Y stage I, II, III 그룹의 SDNN은 $28.21{\pm}10.10$, $22.25{\pm}11.26$, $14.57{\pm}5.31$으로 그룹 I과 그룹III 간에는 유의한 차이가 있었다(P<0.05). RMS-SD는 $19.23{\pm}13.27$, $14.63{\pm}6.44$, $6.44{\pm}2.32$ 으로 역시 그룹 I과 그룹III 간에는 유의한 차이가 있었 다(p<0.05). 2. 주파수영역분석에서 TP는 H-Y stage Ⅰ, II, III 그룹에서 각각 $499.86{\pm}345.45$, $243.72{\pm}212.22$, $99.44{\pm}51.01$로 ANOYA 검정결과 p-value가 0.007로 매우 유의 있었으며, 사후 검정에서는 그룹 I과 II, 그룹 II와 III에서는 유의한 차이가 없었으나 그룹 I과 III에서는 매우 유의한 차이가 있었다(p<0.01). LF는 H-Y stage I과 III 그룹에서 유의한 차이가 있었으나(p<0.05) VLF, HF, LF norm HF nonm LF norm, LF/HF ratio에서는 각 그룹 간 유의한 차이가 없었다. 3. SDNN, RMS-SD, TP가 UPDRS 총점이 증가함에 따라 유의성 있게 감소하는 경향 (p<0.05)을 보이는 것으로 보아 파킨슨병이 진행함에 따라 자율신경계의 활동성이 저하될 것으로 보인다.

  • PDF

Perfluoropolymer Membranes of Tetrafluoroethylene and 2,2,4Trifluofo- 5Trifluorometoxy- 1,3Dioxole.

  • Arcella, V.;Colaianna, P.;Brinati, G.;Gordano, A.;Clarizia, G.;Tocci, E.;Drioli, E.
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1999년도 The 7th Summer Workshop of the Membrane Society of Korea
    • /
    • pp.39-42
    • /
    • 1999
  • Perfluoropolymers represent the ultimate resistance to hostile chemical environments and high service temperature, attributed to the presence of fluorine in the polymer backbone, i.e. to the high bond energy of C-F and C-C bonds of fluorocarbons. Copolymers of Tetrafluoroethylene (TEE) and 2, 2, 4Trifluoro-5Trifluorometoxy- 1, 3Dioxole (TTD), commercially known as HYFLON AD, are amorphous perfluoropolymers with glass transition temperature (Tg)higher than room temperature, showing a thermal decomposition temperature exceeding 40$0^{\circ}C$. These polymer systems are highly soluble in fluorinated solvents, with low solution viscosities. This property allows the preparation of self-supported and composite membranes with desired membrane thickness. Symmetric and asymmetric perfluoropolymer membranes, made with HYFLON AD, have been prepared and evaluated. Porous and not porous symmetric membranes have been obtained by solvent evaporation with various processing conditions. Asymmetric membranes have been prepared by th wet phase inversion method. Measure of contact angle to distilled water have been carried out. Figure 1 compares experimental results with those of other commercial membranes. Contact angles of about 120$^{\circ}$for our amorphous perfluoropolymer membranes demonstrate that they posses a high hydrophobic character. Measure of contact angles to hexandecane have been also carried out to evaluate the organophobic character. Rsults are reported in Figure 2. The observed strong organophobicity leads to excellent fouling resistance and inertness. Porous membranes with pore size between 30 and 80 nanometers have shown no permeation to water at pressures as high as 10 bars. However high permeation to gases, such as O2, N2 and CO2, and no selectivities were observed. Considering the porous structure of the membrane, this behavior was expected. In consideration of the above properties, possible useful uses in th field of gas- liquid separations are envisaged for these membranes. A particularly promising application is in the field of membrane contactors, equipments in which membranes are used to improve mass transfer coefficients in respect to traditional extraction and absorption processes. Gas permeation properties have been evaluated for asymmetric membranes and composite symmetric ones. Experimental permselectivity values, obtained at different pressure differences, to various single gases are reported in Tab. 1, 2 and 3. Experimental data have been compared with literature data obtained with membranes made with different amorphous perfluoropolymer systems, such as copolymers of Perfluoro2, 2dimethyl dioxole (PDD) and Tetrafluorethylene, commercialized by the Du Pont Company with the trade name of Teflon AF. An interesting linear relationship between permeability and the glass transition temperature of the polymer constituting the membrane has been observed. Results are descussed in terms of polymer chain structure, which affects the presence of voids at molecular scale and their size distribution. Molecular Dyanmics studies are in progress in order to support the understanding of these results. A modified Theodoru- Suter method provided by the Amorphous Cell module of InsightII/Discover was used to determine the chain packing. A completely amorphous polymer box of about 3.5 nm was considered. Last but not least the use of amorphous perfluoropolymer membranes appears to be ideal when separation processes have to be performed in hostile environments, i.e. high temperatures and aggressive non-aqueous media, such as chemicals and solvents. In these cases Hyflon AD membranes can exploit the outstanding resistance of perfluoropolymers.

  • PDF

한.중 전통원림의 수경관 연출기법 비교 연구 - 소쇄원과 졸정원을 중심으로 - (Water Landscape Displaying Techinques of Traditional Gardens between China and Korea - With Soswaewon and ZhuozhengYuan -)

  • 이행렬;김선례
    • 한국전통조경학회지
    • /
    • 제30권4호
    • /
    • pp.1-13
    • /
    • 2012
  • 전통원림 중에서 경관이 우수한 곳은 수경관을 중심으로 하는 예가 많다. 한국과 중국의 경우 이러한 점은 현저하게 나타나는데, 그 중에서도 한국은 자연의 형세를 중시하는 기본 사상에 따라서 자연계류를 이용하는 예가 그 특징이라 하겠다. 중국 또한 평탄한 지형에서 원림을 구성하여 자연을 찾는다는 사상에 따라 물과 산을 중시하는 예가 그 특징이다. 이러한 차이점과 공통점을 통하여 양국의 전통원림을 구분짓기 위하여 소쇄원과 졸정원을 대상지로 하여 이들 원림에서 나타나는 수공간의 연출 특징을 파악하고자 한다. 연구 방법으로는 문헌조사, 현장조사를 통하여 원림의 자연환경, 배경사상, 작정자의 인물연구, 수공간을 구성하는 지면, 호안, 건축 및 수경관에 관하여 연구하였다. 결과로 한국의 소쇄원은 전남 담양군에 위치한 원림으로 내원과 외원으로 구성되며, 규모가 작으나 양산보의 은일관을 구현하기 위해 암반 계류를 중심으로 하여 선형적인 수로 형태를 취하고 있으며, 계류를 타고 내려온 물이 인위적인 방지에 모이고, 다시 계류로 흘러가는 형식을 취하고 있다. 호안 구조는 막돌 허튼쌓기로 이루어졌다. 건축물로는 광풍각과 제월당, 대봉대로 이루어져 있으며, 각각의 용도에 따라서 계류를 중심으로 하여 배치되었다. 반면, 중국의 졸정원은 강소성 소주시에 위치하며, 평탄한 지형에 입지하고 있다. 크게 동부원림, 중부원림(졸정원) 및 서부원림으로 이루어졌으며 전체 면적의 5분의 3을 수공간이 차지한다. 연못을 중심으로 정자, 석가산 등이 다양한 경관을 이루고 있으며, 명대의 건축적 특징을 잘 보여주고 있다. 두 나라는 각각 지역의 자연환경과 인문환경 특징이 서로 달라서 고유의 독특한 수경관을 원림 속에 구현하고 있지만, 사상적인 배경이 되는 은일관과 지형 조건에 따라 구분되어지는 원림을 이루고 있다.

한우 후대검정우 체중, 체척 및 도체형질간 상관분석 (Correlation Analyses on Growth Traits, Body Size Traits and Carcass Traits in Hanwoo Steers)

  • 이재구;최연호;박병호;최재관;이승수;나종삼;노승희;최태정
    • 농업생명과학연구
    • /
    • 제46권1호
    • /
    • pp.123-131
    • /
    • 2012
  • 본 연구는 한우 성장형질간의 상관분석을 통하여 6, 12, 18, 24개월 체중, 일당증체량, 도체형질과 18개월 체형형질간의 성장단계별 형질간의 상관관계를 파악하고자 실시하였다. 분석에 이용한 자료는 농협중앙회 한우개량사업소에서 후대 검정을 실시한 2004년에서 2008년까지의 거세우 1,838두의 체중과 체형형질을 이용하였고 도체형질은 24개월령 도축성적을 이용하였다. 본 논문에서 상관분석은 관측치 상관과 고정효과를 고려한 잔차상관으로 하였다. 도축 전 생체중과 도체중은 0.92의 높은 상관관계를 가지고 있었다. 도체형질에서는 육량지수와 등지방두께 간에 -0.92의 높은 부의 상관을 보였다. 체형형질에서 십자부고와 체고는 0.89로서 높은 상관관계가 있었으며 흉폭과 흉심이 0.73의 상관관계를 나타냈다. 체위 형질간 상관에서 요각폭에 대해 흉심과 흉폭이 각각 0.75, 0.74의 상관을 보였고 곤폭은 요각폭과 0.74의 상관을 보였다. 좌골폭에 대해서는 흉심, 흉폭, 요각폭, 곤폭이 각각 0.73, 0.70, 0.75, 0.75로 정의 높은 상관을 나타냈다. 체장과 도체중간의 관측치상관은 0.48이였고, 흉위는 도체중과 잔차상관이 0.51로 다른 도체형질보다 상관정도가 높게 나타났다. 따라서 본 연구결과는 한우 후대검정우 유전평가시 기초 자료로 활용 가능할 것으로 예상된다.

활성화된 질산화균 주입에 의한 저온 질산화효율 향상 (Improvement of Nitrification Efficiency by Activated Nitrifying Bacteria Injection at Low Temperature)

  • 임동일;김영희
    • 한국도시환경학회지
    • /
    • 제18권4호
    • /
    • pp.473-483
    • /
    • 2018
  • 본 연구에서는 Lab 규모의 생물반응장치를 제작하여 운전조건 변화(온도, 저해물질(Cl), 활성화된 질산화균 투입 등)가 질산화에 미치는 영향을 파악하여 저온 조건에서 질산화효율을 향상시킬 수 있는 방안을 찾고자 하였다. $NO_2{^-}-N+NO_3{^-}-N$ 농도 실험에서 $20^{\circ}C$의 경우 염소를 투입하여 질산화균을 사멸한 후 활성화된 질산화균을 투입하면, 정상수준까지 회복하는데 약 4일 정도 소요되었다. $10^{\circ}C$의 경우, 활성화된 질산화균을 투입하여 이전 상태로 회복 되는 데는 약 7일 정도 소요되어 $20^{\circ}C$에 비하여 약 3일이 더 소요되었다. 비질산화속도 실험에서는 $10^{\circ}C$ 운전조건에서 활성화된 질산화균 투입 후 1일경과시 비질산화속도는 0029 mgN/gSS/hr에서 6일 경과시 0.767 mgN/gSS/hr까지 증가하였다. 선형 모형식과 지수함수 모형식에 의한 8일 경과후의 비질산화속도는 각각 0.840, 3.625 mgN/gSS/hr로 예측되어 정상수준인 2.592 mgN/gSS/hr을 상회하는 것으로 예상되었다. 본 연구를 통하여 저온 운전시 활성화된 질산화균을 주입하면 질산화효율을 향상시키는데 많은 효과가 있음을 확인하였다. 향후 연구에서 현장별 운전특성을 고려한 ANB 투입량의 결정, 효율적인 ANB reactor의 설계 등에 대한 추가적인 연구가 진행된다면 동절기 질산화효율 향상에 많은 기여를 할 수 있을 것이다.

SLURP 모형을 이용한 기후, 식생, 토지이용변화가 농업용 저수지 유역과 하천유역에 미치는 기여도 평가(II) - 모형의 검·보정 및 적용 - (Assessment of the Contribution of Weather, Vegetation and Land Use Change for Agricultural Reservoir and Stream Watershed using the SLURP model (II) - Calibration, Validation and Application of the Model -)

  • 박근애;안소라;박민지;김성준
    • 대한토목학회논문집
    • /
    • 제30권2B호
    • /
    • pp.121-135
    • /
    • 2010
  • 본 연구에서는 연구(I)에서 구축한 고도, 기상, 토지이용, 토양, 식생과 같은 기본 입력자료와 공도 수위관측소 상류유역을 대상으로 유역내에 포함되어 있는 농업용 저수지인 고삼과 금광저수지의 저수위, 저수량, 내용적 곡선 자료들을 이용하여 SLURP 모형의 물리적 매개변수들과 저수지의 방류량을 조정하여 저수지의 저수위와 유역 유출량을 검 보정하였다. 한편, 연구(I)에서의 편이보정과 CF 다운스케일기법에 의한 CCCma CGCM2 A2, B2 시나리오의 미래 기후자료, 개선된 CA-Markov 기법에 의한 미래 토지이용자료, 월 NDVI와 평균온도와의 선형회귀식에 의한 미래 식생자료 등을 모형에 입력하여 미래 기후변화에 따른 저수지 저수량과 유입량에 미치는 영향을 평가하고 전체적인 유역 수문(증발산량, 토양수분, 지하수충진량, 유출량)의 변화를 평가하였다. 저수지의 미래 저수량과 유입량은 가을시기에 크게 감소하는 것으로 평가되었고, 유역의 미래 연유출량, 토양수분, 지하수충진량은 다소 감소하고, 증발산량은 크게 증가하는 것으로 전망되었다. 마지막으로, 미래 기후변화, 토지이용변화와 식생변화 중 어떠한 요소가 미래의 농업용 저수지의 유입량, 저수량 및 하천유역의 수문에 큰 영향을 미치는 지를 평가하기 위해 각 요소의 기여도를 분석한 결과, 기후변화가 가장 크게 기여하는 것으로 평가되었다.

중국의 도시녹지 종류와 도시거주구 녹지의 설치 기준에 관한 법제도의 현황과 특성 (The Characteristic of Laws on the Kind of Urban Green Spaces and the Legal Requirements for the Green Spaces of Urban Habitat in China)

  • 신익순
    • 한국조경학회지
    • /
    • 제41권3호
    • /
    • pp.1-11
    • /
    • 2013
  • 본 연구는 도시녹지에 관한 현행 중국의 법제도를 조사하여 도시녹지의 종류와 도시거주구 녹지의 설치 기준을 항목별로 분류해 봄으로써 그 속성을 이해하고, 국내 규정과 상이한 특이점을 분석 고찰함으로써 향후 이들 법규의 국내 도입 여부를 위한 기초 자료를 제공하고자 수행되었다. 본 연구를 통해 도출된 결과는 다음과 같이 요약할 수 있다. 첫째, 공원녹지, 생산녹지, 방호녹지, 부속녹지, 기타녹지 등 5종류로 구분되는 중국의 도시녹지는 공원과 녹지 개념이 동시에 포함되어 있는 점이 공원과 녹지가 엄밀히 구분되어 있는 국내의 공원녹지 개념과는 상이하며, 종합공원, 공동체공원, 전문공원 및 대상(帶狀)공원 등으로 구분되는 중국의 도시공원의 종류는 하위 법규인 '도시녹지분류표준'에서 밝히고 있다. 둘째, 옥상조경 시 중국에서는 주민 출입이 용이한 지하나 반지하 건물의 옥상 외에는 옥상조경의 조경면적을 도시녹지의 녹지율 산입에 포함시키지 않고 있고, 도시 주민들의 생활환경 확보를 위해 거주구 계획 설계 시의 녹지 요구 조항과 거주구, 소구(小區), 조단(組團) 등 거주구 종류별 의무적 공공녹지 확보율이 구체적으로 명시되어 있다. 셋째, 거주구 내 녹지계획 시 녹지계통 수립이 의무화되고, 기존 수목과 녹지의 보존 이용을 명시하고 있다. 녹지율은 구거주구 재정비시의 경우 신거주구 건설시보다 완화시켜 주고, 특이하게 녹지 경사도를 별도로 명시하고 있다. 거주구공원, 어린이공원(소유원(小遊園)), 조단(組團)녹지 등 각급 중심녹지의 설치 내용, 요구사항 및 최소 면적 규모가 명시되어 있고, 특히 조단녹지의 일종인 정원식 조단녹지는 폐쇄형 녹지와 개방형 녹지로 분류하여, 다층 고층 건물별로 남 북측 건물 간격과 녹지 면적 확보치를 밝히고 있으며, 녹지 면적 계산법이 별도의 규범에 제시되어 있다. 넷째, 거주구별 달성해야 할 거주구 내 공공녹지의 1인당 확보 면적인 총 지표가 정해져 있고, 이 경우 노후 구역 재정비시에는 일정치까지 완화할 수 있다. 공공녹지의 위치와 규모, 최소폭, 개소당 최소 면적 등이 명시되어 있고, 도로와의 인접, 전체 면적 대비 녹화 면적비, 개방적 공간 확보, 일조음영선 범위 등 공간 배치 원칙이 규정되어 있다. 다섯째, 지하관선 설치 시의 녹지 고려 사항으로 지하관선과 주변 녹화수목과의 최소 수평 이격거리가 명시되어 있고, 공공서비스 시설 중 녹지 설치를 위해 종류별 서비스 내용에 따른 녹지 설치 원칙이 규정되어 있다. 국내 규정에는 없는 중국 법규만의 특이점에 대한 국내 도입 여부의 검토가 향후 요구되고, 이상의 연구 결과는 중국의 도시녹지 관련 법제도 연구의 당면성에 대한 국내 조경가들의 공감대를 형성하는데 기여할 수 있을 것이며, 나아가 조경 법제도의 국제화 진입의 계기 역할을 하게 될 것이다.