• 제목/요약/키워드: Linear Drop Test

검색결과 34건 처리시간 0.027초

Plantar Pressure Distribution During Level Walking, and Stair Ascent and Descent in Asymptomatic Flexible Flatfoot

  • Kim, Jeong-Ah;Lim, One-Bin;Yi, Chung-Hwi
    • 한국전문물리치료학회지
    • /
    • 제20권4호
    • /
    • pp.55-64
    • /
    • 2013
  • The first purpose was to identify the plantar pressure distributions (peak pressure, pressure integral time, and contact area) during level walking, and stair ascent and descent in asymptomatic flexible flatfoot (AFF). The second purpose was to investigate whether peak pressure data during level walking could be used to predict peak pressure during stair walking by identifying correlations between the peak pressures of level walking and stair walking. Twenty young adult subjects (8 males and 12 females, age $21.0{\pm}1.7$ years) with AFF were recruited. A distance greater than 10 mm in a navicular drop test was defined as flexible flatfoot. Each subject performed at least 10 steps during level walking, and stair ascent and descent. The plantar pressure distribution was measured in nine foot regions using a pressure measurement system. A two-way repeated analysis of variance was conducted to examine the differences in the three dependent variables with two within-subject factors (activity type and foot region). Linear regression analysis was conducted to predict peak pressure during stair walking using the peak pressure in the metatarsal regions during level walking. Significant interaction effects were observed between activity type and foot region for peak pressure (F=9.508, p<.001), pressure time integral (F=5.912, p=.003), and contact area (F=15.510, p<.001). The regression equations predicting peak pressure during stair walking accounted for variance in the range of 25.7% and 65.8%. The findings indicate that plantar pressures in AFF were influenced by both activity type and foot region. Furthermore the findings suggest that peak pressure data during level walking could be used to predict the peak pressure data during stair walking. These data collected for AFF can be useful for evaluating gait patterns and for predicting pressure data of flexible flatfoot subjects who have difficulty performing activities such as stair walking. Further studies should investigate plantar pressure distribution during various functional activities in symptomatic flexible flatfoot, and consider other predictors for regression analysis.

여성선수의 신경인지 능력과 전방십자인대 손상 위험요인과의 관계 (Relationship between Neurocognitive Ability and Risk Factors of Anterior Cruciate Ligament Injuries in Female Athletes)

  • 하성희;박상균
    • 한국융합학회논문지
    • /
    • 제9권8호
    • /
    • pp.301-309
    • /
    • 2018
  • 본 연구의 목적은 여성선수의 신경인지능력이 양발 착지 시 비접촉성 전방십자인대 손상의 위험요인과 어떠한 관계가 있는지 규명하는 것이다. 여성선수 32명을 대상으로 신경인지검사와 양발 착지에 대한 동작분석을 실시하였다. 전산화된 신경인지 검사의 원점수와 동작분석을 통해 산출된 3차원 관절각, 모멘트, 파워, 수직지면반력, 부하율, 지지시간의 상관관계 분석을 위해 피어슨의 정률상관분석을 실시하였다. 연구결과 신경인지 점수가 높을수록 착지 시 자세유지를 위한 전략을 사용하는 것이 관찰되었다. 따라서 신경인지 검사는 잠재적인 전방십자인대 손상의 위험인자를 검출하기 위한 스크리닝 방법으로 사용 될 수 있을 것으로 생각된다.

Experiment Investigation on Fluid Transportation Performance of Propellant Acquisition Vanes in Microgravity Environment

  • Zhuang, Baotang;Li, Yong;Luo, Xianwu;Pan, Halin;Ji, Jingjing
    • International Journal of Fluid Machinery and Systems
    • /
    • 제7권1호
    • /
    • pp.1-6
    • /
    • 2014
  • The propellant acquisition vane (PAV) is a key part of a vane type surface tension propellant management device (PMD), which can manage the propellant effectively. In the present paper, the fluid transportation behaviors for five PAVs with different sections were investigated by using microgravity drop tower test. Further, numerical simulation for the propellant flow in a PMD under microgravity condition was also carried out based on VOF model, and showed the similar flow pattern for PAVs to the experiment. It is noted that the section geometry of PAVs is one of the main factors affecting the fluid transportation behavior of PMD. PAVs with bottom length ratio of 5/6 and 1/2 have larger propellant transportation velocity. Based on the experiments, there were two stages during the process of propellant transportation under microgravity environment: liquid relocation and steady transportation stage. It is also recognized that there is a linear correlation between liquid transportation velocity and relative time's square root. Those results can not only provide a guideline for optimization of new vane type PMDs, but also are helpful for fluid control applications in space environment.

확률과정론을 이용한 추진장약의 성능과 저장안전성에 관한 저장신뢰성평가 (The Stockpile Reliability of Propelling Charge for Performance and Storage Safety using Stochastic Process)

  • 박성호;김재훈
    • 품질경영학회지
    • /
    • 제41권1호
    • /
    • pp.135-148
    • /
    • 2013
  • Purpose: This paper presents a method to evaluate the stockpile reliability of propelling charge for performance and storage safety with storage time. Methods: We consider a performance failure level is the amount of muzzle velocity drop which is the maximum allowed standard deviation multiplied by 6. The lifetime for performance is estimated by non-linear regression analysis. The state failure level is assumed that the content of stabilizer is below 0.2%. Because the degradation of stabilizer with storage time has both distribution of state and distribution of lifetime, it must be evaluated by stochastic process method such as gamma process. Results: It is estimated that the lifetime for performance is 59 years. The state distribution at each storage time can be shown from probability density function of degradation. It is estimated that the average lifetime as $B_{50}$ life is 33 years from cumulative failure distribution function curve. Conclusion: The lifetime for storage safety is shorter than for performance and we must consider both the lifetime for storage safety and the lifetime performance because of variation of degradation rate.

BBDB형 진동수주 파력발전장치의 운동 및 파랑표류력 연구 (A Study on Motion and Wave Drift Force of a BBDB Type OWC Wave Energy Device)

  • 김진하;류재문;홍도천;홍석원
    • 한국해양공학회지
    • /
    • 제20권2호
    • /
    • pp.22-28
    • /
    • 2006
  • The motion and wave drift forces of floating BBDB (backward-bent duct buoy) wave energy absorbers in regular waves are calculated, taking account of the oscillating surface-pressure due to the pressure drop in the air chamber above the oscillating water column, within the scope of the linear wave theory. A series of model tests has been conducted in order to order to verify the motion and time mean wave drift force reponses in regular waves at the ocean engineering basin, MOERI/KORDI. The pneumatic damping through an orifice-type duct for the BBDB wave energy device are deducted from experimental research. Numerical simulation for motion and drift force responses of the BBDB wave energy device, considering pneumatic damping coefficients, has been carried out, and the results are compared with those of model tests.

Analysis of the Strength Property for TiC-Mo Composites at High Temperature

  • Shin, Soon-Gi
    • 한국재료학회지
    • /
    • 제24권4호
    • /
    • pp.201-206
    • /
    • 2014
  • TiC-21 mol% Mo solid solution (${\delta}$-phase) and TiC-99 mol% Mo solid solution (${\beta}$-phase), and TiC-(80~90) mol% Mo hypo-eutectic composite were deformed by compression in a temperature range from room to 2300 K and in a strain rate range from $4.9{\times}10^{-5}$ to $6.9{\times}10^{-3}/s$. The deformation behaviors of the composites were analyzed from the strengths of the ${\delta}$- and ${\beta}$-phases. It was found that the high strength of the eutectic composite is due primarily to solution hardening of TiC by Mo, and that the ${\delta}$-phase undergoes an appreciable plastic deformation at and above 1420 K even at 0.2% plastic strain of the composite. The yield strength of the three kinds of phase up to 1420 K is quantitatively explained by the rule of mixture, where internal stresses introduced by plastic deformation are taken into account. Above 1420 K, however, the calculated yield strength was considerably larger than the measured strength. The yield stress of ${\beta}$-phase was much larger than that of pure TiC. A good linear relationship was held between the yield stress and the plastic strain rate in a double-logarithmic plot. The deformation behavior in ${\delta}$-phase was different among the three temperature ranges tested, i.e., low, intermediate and high. At an intermediate temperature, no yield drop occurred, and from the beginning the work hardening level was high. At the tested temperature, a good linear relationship was held in the double logarithmic plot of the yield stress against the plastic strain rate. The strain rate dependence of the yield stress was very weak up to 1273 K in the hypo-eutectic composite, but it became stronger as the temperature rose.

1:5 축소 10층 내력벽식 R.C. 공동주택의 지진모의실험 (Earthquake Simulation Tests on a 1:5 Scale 10-Story R.C. Residential Building Model)

  • 이한선;황성준;이경보;강창범;이상호;오상훈
    • 한국지진공학회논문집
    • /
    • 제15권6호
    • /
    • pp.67-80
    • /
    • 2011
  • 본 논문에서는 1:5 축소 10층 내력벽식 철근콘크리트(RC) 내력벽식 공동주택의 지진모의실험의 결과를 제시한다. 실험의 결과는 다음과 같다. (1) 본 실험 모델에서 재현주기 50년 지진에 대해서는 선형 탄성응답을 보이며, 우리나라의 설계지진에 대해서는 비선형 거동을 확인할 수 있다. (2) 재현주기 2400년의 최대지진에 대해 실험체의 강성 및 강도 저하가 현저하게 나타났다. (3) 횡 관성력에 대한 주 저항은 주로 엘리베이터 홀과 계단실 벽체로부터 유래되었다. (4) 실험체의 손상 및 파괴 모드는 벽과 슬래브의 휨 거동에 의해 지배되었다. 가진의 크기가 증가 할수록 현저한 강성의 저하와 고유주기의 증가가 발생하였다.

촉진부식실험을 이용한 OPC 및 슬래그 콘크리트의 부식-부착강도 평가 (Corrosion-bond Strength Evaluation in OPC and Slag Concrete using Accelerated Corrosion Test)

  • 오상진;이현우;권성준
    • 한국건설순환자원학회논문집
    • /
    • 제12권1호
    • /
    • pp.1-7
    • /
    • 2024
  • 다공성인 콘크리트에서는 외부의 수분 및 염화물 유입이 발생하며, 이는 매립된 철근의 부식을 야기한다. 본 연구에서는 촉진부식실험(ICM: Impressed Current Method)를 이용하여 10 V의 전압을 인가하였으며, 이에 따라 10 % 수준까지 부식량을 조절하였다. 부식량은 부식전류량 누계와 선형적인 관계가 도출되었으며, 균열의 영향으로 부식 유도 시간에 따라 2차 함수의 형태로 증가하였다. 부착응력에 대해서는 OPC 콘크리트에 대해서는 부식량 3.0 % 이후 급격한 부착응력의 감소가 발생하였다. 또한 치환률 30 %의 슬래그 콘크리트에서는 일반 콘크리트에 비하여 51.4~71.6 %의 낮은 부식량을 나타내었으며 5일간의 촉진실험에도 일정 수준의 부착강도를 유지하였다.

담수 및 퇴적물에 함유된 아연, 카드뮴, 납 및 구리의 산화전극 벗김 전압전류법 정량 (Anodic Stripping Voltammetric Determinations of Zinc, Cadmium, Lead and Copper in Freshwater and Sediment)

  • 한영희;유정연
    • 대한화학회지
    • /
    • 제41권4호
    • /
    • pp.180-185
    • /
    • 1997
  • 매달린 수은 방울 전극(HMDE) 또는 얇은 수은막 전극(TMFE)을 사용하여 금속이온들을 은/염화은(포화 KCl) 기준전극에 대하여 -1,200 V에서 150초 동안 전해시켜서 수은전극에 농축시키고 펄스 차이 전압전류법(DPASV)과 네모파 전압전류법(SWASV)으로 산화전극 벗김 분석을 하여 동시에 아연, 카드뮴, 납 및 구리를 정량분석하였다. HMDE를 사용하여 DPASV로 네 가지 금속이온을 동시 정량분석시 각각의 금속이온의 봉우리 전류는 20~100 ppb 농도범위에서 직선성을 보여주었으나 TMFE를 사용하여 DPASV 또는 SWASV로 네 가지 금속이온을 동시 정량분석시에는 $Cd^{2+}$$Pb^{2+}$의 봉우리 전류만 DPASV의 경우 100 ppb까지 SWASV의 경우 10 ppb까지 직선성을 나타내었다. $Cd^{2+}$$Pb^{2+}$의 동시 정량분석의 경우 TMFE를 사용한 DPASV 분석은 HMDE를 사용한 DPASV보다 약 15배 더 민감하였으며 TMFE에서 SWASV는 DPASV보다 약 5배 더 민감하였다. 퇴적물에 함유된 아연의 농도를 HMDE를 사용한 DPASV 분석법과 유도 결합 플라스마-질량분석법으로 일곱개의 시료에 대하여 정량분석하여 비교하였더니 상관계수가 0.9993으로 높았고 t-test결과 두 방법 사이에는 유의성 있는 차이가 없었다.

  • PDF

유기전해질에 따른 EDLC의 전기화학적 특성 (Electrochemical Characteristics of EDLC with various Organic Electrolytes)

  • 양천모;이중기;조원일;조병원;임병오
    • 전기화학회지
    • /
    • 제4권3호
    • /
    • pp.113-117
    • /
    • 2001
  • 탄소계 전극을 사용하는 EDLC(Electric Double Layer Capacitor)용의 축전용량과 충방전속도는 전해질의 종류, 충방전 조건 그리고 탄소계 물질의 물리화학적 성질에 따라 크게 달라질 수 있다. 이에 본 연구에서는 dip coating method에 의해 제조된 EDLC용 활성탄소 전극에서 유기 전해질의 종류를 달리하여 충방전 실험과 전기화학적인 실험을 시행하였다. 또한 충전전류밀도와 방전전류밀도의 변화에 따른 비축전 용량의 변화를 조사하였고, 최적 유기전해질의 조건에서 leakage current 특성, 자가방전 특성 그리고 시간전압곡선을 기존의 $1M-Et_4NBF_4/PC$와 비교하였다 활성탄, 소전극으로 비표면적이 $2000m^2/g$인 MSP-20을 사용하고 유기전해질로는 $1M-LiPF_6/PC-DEC(1:1)$를 사용한 EDLC에서 130 F/g 정도의 우수한 비축전 용량을 나타내었고 저항면에서도 가장 낮은 수치를 나타내었다 $1M-LiPF_6/PCDEC(1:1)$를 사용한 EDLC는 15분동안 0.0004A의 낮은 leakage current와 100시간 경과 후 0.8V의 우수한 자가 방전 특성 그리고 IR-drop이 적은 선형의 시간-전압곡선을 보여주었다.