• Title/Summary/Keyword: Linear Array

Search Result 731, Processing Time 0.021 seconds

Reliability of Exterior Orientation in Bundle Adjustment for SPOT Imagery (SPOT 영상을 위한 번들조성에서 외부표정의 신뢰성)

  • Park, Hong Gi
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.12 no.1
    • /
    • pp.151-158
    • /
    • 1992
  • Topographic mapping from economic SPOT stereo imagery than aerial photographs has become possible. Many of authors have studied the possibility of base map revisions and the accuracy of results. They have concluded that the SPOT image is suitable for 1/50,000 to 1/100,000 topographic map. For topographic map, orthophoto and DTM generation from SPOT imagery, accurate exterior orientation parameters are needed. But since the geometric characteristic of SPOT image is dynamic linear array imagery, the conventional bundle adjustment for photogrammetry can not be directly applied. Reliability is the ability to detect gross error, which is called the internal reliability, and the effect of non-detectable gross error on the results of exterior orientation, which is called the external reliability. This paper shows how the reliability of SPOT imagery depends on the different coordinate systems, presentations of coordinate for flight direction, orders of exterior orientation parameters and distribution of control points, and thus analyses the theoretical reliability of the exterior orientation, which can provide a basis for the planning of SPOT projects.

  • PDF

Comparative Analyses of Bioactive Constituents from Forsythia suspensa and Forsythia viridissima by HPLC-DAD

  • Won, Tae-Hyung;Liao, Lijuan;Lee, Seung-Ho;Son, Jong-Keun;Shin, Jong-Heon
    • Natural Product Sciences
    • /
    • v.17 no.4
    • /
    • pp.328-336
    • /
    • 2011
  • A high-performance liquid chromatography (HPLC) with diode array detector (DAD) method was established for the discrimination of a folk medicine Forsythia suspensa and Forsythia viridissima. Five and three representative metabolites of the lignan and phenolic glycoside classes were selected for the analysis from F. suspensa and F. viridissima, respectively. The optimal chromatographic conditions were obtained on an ODS column (5 ${\mu}m$, $4.6{\times}250$ mm) with the column temperature at $40^{\circ}C$. The mobile phase was composed of methanol and 0.3% acetic acid using an isocratic elution with the flow rate 1 mL/min. Detection wavelength was set at 280 nm. All calibration curves showed good linear regression ($r^2$ > 0.996) within test ranges. Limits of detection (LOD) and limits of quantitation (LOQ) values were lower than 0.096 and 0.291 ${\mu}g/mL$, respectively. The developed method provided satisfactory precision and accuracy with overall intra-day and inter-day variations of 0.07-0.63% and 0.14-0.62%, respectively, and the overall recoveries of 97.79-102.46% for all of the compounds analyzed. In addition, effectiveness of diverse extraction methods was compared to each other for the development of standard analytical method. The verified method was successfully applied to the quantitative determination of representative metabolites in fifty-three commercial F. suspensa samples and fifteen commercial F. viridissima samples from diverse sources. The overall analytical results showed the unequivocal differences in bioactive constituents between F. suspensa and F. viridissima.

Simultaneous Quantification of Three Marker Compounds in Samultang by HPLC/DAD (HPLC-DAD를 이용한 사물탕 중 3종 성분의 동시분석법 확립)

  • Won, Jin-Bae;Ma, Jin-Yeul;Lee, Jae-Hoon;Ma, Choong-Je
    • Korean Journal of Pharmacognosy
    • /
    • v.40 no.4
    • /
    • pp.298-302
    • /
    • 2009
  • Samultang is one of traditional medicine composed of Paeonia lactiflora, Angelica gigas, Rehmannia glutinosa and Cnidium officinale. To develop simultaneous determination of paeoniflorin, decursin and 5-HMF in Samultang, a high performance liquid chromatography with diode array detector was used. To separate three marker components, Dionex $C_{18}$ column (5 ${\mu}m$, 120 ${\AA}$, 4.6 mm${\times}$150 mm) was used with a gradient elution system of water and methanol. UV wavelength of detector set at 230 nm and 280 nm. This method was validated by linearity, precision test and recovery test. Calibration curves of three standard components were showed good linear regression ($R^2$>0.9973). LOD and LOQ ranged from 0.08 ${\mu}g$/ml to 0.38 ${\mu}g$/ml and 0.25 ${\mu}g$/ml to 1.16 ${\mu}g$/ml, respectively. The relative standard deviations (RSDs) of data of the inter-day and intra-day experiments were less than 0.54% and 0.89%, respectively. The measured results of recovery test were varied from 93.36 to 107.79 with RSD values 0.01~1.45%. The established method was applied for separation of bio-conversion Samultang sample and compared with control sample.

Simultaneous Determination of 11 Marker Compounds in Gumiganghwal-tang by HPLC-DAD and LC-MS

  • Weon, Jin Bae;Jung, Youn Sik;Ryu, Gahee;Yang, Woo Seung;Ma, Choong Je
    • Natural Product Sciences
    • /
    • v.22 no.4
    • /
    • pp.238-245
    • /
    • 2016
  • Gumiganghwal-tang has been used for the treatment of common cold for a long-time. We developed an accurate and sensitive high performance liquid chromatography-diode array detection (HPLC-DAD) and electrospray ionization mass spectrometry method for the simultaneous determination of ferulic acid, baicalin, bergapten, methyl eugenol, glycyrrhizin, oxypeucedanin, wogonin, nodakenin, atractylenolide III, imperatorin, and atractylenolide I in Gumiganghwal-tang samples. The analytes were separated on a Shiseido C18 column ($5{\mu}m$, $4.6mm\;I.D.{\times}250mm$) with gradient elution with acetonitrile and 0.1% trifluoroacetic acid. Eleven compounds were quantitatively determined by HPLC-DAD and identified by LC-MS data. We also validated this method. The calibration curves of all the compounds showed good linear regression. The limits of detection and the limits of quantification ranged from 0.04 to 0.63 and from 0.12 to $1.92{\mu}g/mL$, respectively. The relative standard deviation values of intra- and inter-days of this method represented less than 2.9%. The recoveries were found to be in the range of 90.06 - 107.66%. The developed method has been successfully applied to the analysis of Gumiganghwaltang samples. The established HPLC method could be used to quality control of Gumiganghwal-tang.

The DOE Based Robust Design to Reduce the Brake Squeal Noise (실험계획법에 기반한 브레이크 스퀼 노이즈 저감을 위한 강건 설계)

  • Kwon, Seong-Jin;Kim, Mun-Sung;Lee, Bong-Hyun;Lee, Dong-Won;Bae, Chul-Yong;Kim, Chan-Jung
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.2
    • /
    • pp.126-134
    • /
    • 2007
  • Although there has been substantial research on the squeal noise for the automotive brake system, robust design issues with respect to control factors equivalent to design variables in optimization, noise factors due to system uncertainties, and signal factors designed to accommodate a user-adjustable setting still need to be addressed. For the purpose, the robust design applied to the disk brake system has been investigated by DOE (Design of Experiments) based Taguchi analysis with dynamic characteristics. The specific goal of this methodology is to identify a design with linear signal-response relationship, and variability minimization. The finite element models of the disk brake assembly have been constructed, and the squeal noise problems have been solved by complex eigenvalue analysis. As the practical robust design to reduce the brake squeal noise, material properties of pad, disk, and backplate, thickness and geometry of pad are selected as control factors, material properties of pad and disk, and the contact stiffness have been considered as noise factors, and friction coefficient between pad and disk is chosen as a signal factor. Through the DOE based robust design, the signal-to-noise ratio and the sensitivity for each orthogonal array experiment have been analyzed. Also, it has been proved that the proposed robust design is effective and adequate to reduce the brake squeal noise.

Comparative Follicular Dynamics in Superovulated Crossbred Cows and Water Buffaloes

  • Manik, R.S.;Singla, S.K.;Madan, M.L.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.11 no.1
    • /
    • pp.65-70
    • /
    • 1998
  • To understand the caused for poor response to superovulation in water buffalo compared to crossbred cows, follicular events, before start of superovulation, during superovulation and after superovulation were compared. Follicular development was monitored a day before start of superovulation, daily upto superestrus and on the day of flushing. A real time B mode diagnostic instrument equipped with a linear array, 5 MHz transducer was used in five crossbred cows and five Murrah buffaloes. Crossbred cows yielded significantly (p < 0.01) higher number of corpora lutea than buffaloes (21 vs 10). The mean number of small size (2 to 5 mm); medium size (6 to 9 mm) and large size $({\geq}10mm)$ follicles, a day before start of superovulation were almost similar or even slightly higher in buffalo. Though initial shift in the mean number of follicles was higher in buffalo than cow, yet, from Day 2 to Day 3 of the treatment, the average increase in medium (3.2 vs 1.2) and large size (5.0 vs 2.0) follicles was higher in cows than buffaloes. The mean number of medium and large size follicles was 9.8 and 14.4 in cows and 6.4 and 7.6 in buffaloes. On the day of flushing, the number of large size follicle was more in buffaloes than cows, indicating the ovulation problem in this species. The major conclusion from this investigation was that, a day before start of superovulatory treatment, the number of small and medium size follicles was slightly higher in buffaloes, even then superovulatory response was better in cows, due to shift, recruitment and passage of follicles from smaller size to larger size from Day 2 of treatment. Ovulation problem in buffaloes was also responsible for lower superovulatory responses as revealed by the presence of higher number of large size follicles on the day of flushing.

A Whole Genome Association Study on Meat Palatability in Hanwoo

  • Hyeong, K.E.;Lee, Y.M.;Kim, Y.S.;Nam, K.C.;Jo, C.;Lee, K.H.;Lee, J.E.;Kim, J.J.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.27 no.9
    • /
    • pp.1219-1227
    • /
    • 2014
  • A whole genome association (WGA) study was carried out to find quantitative trait loci (QTL) for sensory evaluation traits in Hanwoo. Carcass samples of 250 Hanwoo steers were collected from National Agricultural Cooperative Livestock Research Institute, Ansung, Gyeonggi province, Korea, between 2011 and 2012 and genotyped with the Affymetrix Bovine Axiom Array 640K single nucleotide polymorphism (SNP) chip. Among the SNPs in the chip, a total of 322,160 SNPs were chosen after quality control tests. After adjusting for the effects of age, slaughter-year-season, and polygenic effects using genome relationship matrix, the corrected phenotypes for the sensory evaluation measurements were regressed on each SNP using a simple linear regression additive based model. A total of 1,631 SNPs were detected for color, aroma, tenderness, juiciness and palatability at 0.1% comparison-wise level. Among the significant SNPs, the best set of 52 SNP markers were chosen using a forward regression procedure at 0.05 level, among which the sets of 8, 14, 11, 10, and 9 SNPs were determined for the respectively sensory evaluation traits. The sets of significant SNPs explained 18% to 31% of phenotypic variance. Three SNPs were pleiotropic, i.e. AX-26703353 and AX-26742891 that were located at 101 and 110 Mb of BTA6, respectively, influencing tenderness, juiciness and palatability, while AX-18624743 at 3 Mb of BTA10 affected tenderness and palatability. Our results suggest that some QTL for sensory measures are segregating in a Hanwoo steer population. Additional WGA studies on fatty acid and nutritional components as well as the sensory panels are in process to characterize genetic architecture of meat quality and palatability in Hanwoo.

Development of an Electronic Nose System for Evaluation of Freshness of Pork (돈육의 신선도 평가를 위한 전자코 시스템 개발)

  • Lee, Hoon-Soo;Cho, Byoung-Kwan;Chung, Chang-Ho;Lee, Ki-Teak;Jo, Cheo-Run
    • Journal of Biosystems Engineering
    • /
    • v.34 no.6
    • /
    • pp.462-469
    • /
    • 2009
  • The aim of this study was to develop a portable electronic nose system for freshness measurement of stored pork. An electronic nose system was constructed using seven different MOS sensor array. To determine the quality change of pork with storage time, the samples were divided into ten groups in terms of storage time with an increment of 2 day up to 19 storage days. GC-MS, total bacteria's count (TBC), thiobarbituric acid reactive substance (TBARS), and pH analyses as well as the analysis of the electronic nose system measurement were performed to monitor the freshness change of the samples. To investigate the performance of the electronic nose system for detecting the change of freshness of pork, the acquired signal values of the system were compared with those of GC-MS, TBC, TBARS, and pH analysis values. According to principal component analysis (PCA) and linear discriminant analysis (LDA) with the signals of the electronic nose system for the pork samples, the sample groups were clearly separated into two groups of 1-9 days and 11-19 days, and four groups of 1-3 days, 5-9 days, 11 days, and 13-19 days respectively. The results show that the electronic nose system has potential for evaluating freshness of pork.

Sonoanatomic Variation of Pes Anserine Bursa

  • Imani, Farnad;Rahimzadeh, Poupak;Gharehdag, Farid Abolhasan;Faiz, Seyed Hamid Reza
    • The Korean Journal of Pain
    • /
    • v.26 no.3
    • /
    • pp.249-254
    • /
    • 2013
  • Background: The pes anserine bursa lies beneath the pes anserine tendon, which is the insertional tendon of the sartorius, gracilis, and semitendinosus muscles on the medial side of the tibia, but it can lie in different sites in the medial knee. Accurate diagnosis of the position of the bursa is critical for diagnostic and therapeutic goals. The aim of this study was to evaluate sonoanatomic variations of the pes anserine bursa in the medial knee. Methods: One hundred seventy asymptomatic volunteers were enrolled in this study. Using ultrasound imaging (transverse approach, 7-13 MHz linear array probe) the sonoanatomic position of the pes anserine bursa and its relation to the pes anserine tendon were evaluated. Additionally, we evaluated the sonoanatomic variation of the saphenous nerve. Results: The position of the pes anserine bursa was between the medial collateral ligament and the pes anserine tendons in 21.2%/18.8% (males/females) of subjects; between the pes anserine tendons and the tibia in 67.1%/64.7% (m/f); and among the pes anserine tendons in 8.2%/12.9% (m/f). No significant differences in the position of the bursa existed between males and females. The saphenous nerve was found within the pes anserine tendons in 77.6%/74.1% (m/f) of subjects, but outside the pes anserine tendons in 18.8%/15.3% (m/f). Visibility of sonoanatomic structures was not related to either gender or BMI. Conclusions: Ultrasound provides very accurate information about variations in the pes anserine bursa and the saphenous nerve. This suggests that our proposed ultrasound method can be a reliable guide to facilitate approaches to the medial knee for diagnostic and therapeutic objectives.

Pre-vaccination Prevalence and Genotype Distribution of Human Papillomavirus Infection among Women from Urban Tunis: a Cross-sectional Study

  • Guettiti, Haifa;Ennaifer, Emna;Attia, Leila;Chelly, Dalenda;Alaya, Nissaf Ben;Aissa, Rim Ben;Laassili, Thalja;Boubaker, Samir
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.21
    • /
    • pp.9361-9365
    • /
    • 2014
  • Background: To estimate the pre-vaccination distribution of human papillomavirus (HPV) types among women from urban Tunis. Materials and Methods: A total of 611 women aged 18-69 years were enrolled in three local gynaecological outpatient departments. All underwent a gynaecological examination with Pap test and dry swab for HPV detection and typing performed by linear array genotyping test (Roche). Cytological examination was conducted on conventional Pap smears. Results: HPV DNA was found in 6.5% of the women; the most frequent HPV types were HPV 16 and HPV 11 at 3.27% and 1.96%, respectively. The second most frequent high risk (HR) HPV type was HPV 58 (0.82%) followed by HPV 18, HPV 31 and HPV 33 found in only 0.33% of women. Single infections with HPV types, targeted by the quadrivalent vaccine (6, 11, 16, and 18), were detected in 3.6 % of the study patients (55% of positive women). HPV infection was found in 3.83% of women with normal cytology and in 47.4% of women with cytological abnormalities. No statistically significant trend in prevalence by age group emerged for any HPV type or for high or low risk types. Conclusions: These data show a relatively low prevalence of HPV infection in women from urban Tunis with a high proportion of HPV16 and HPV58. This should be considered in the upcoming screening programs and vaccination strategy.