• Title/Summary/Keyword: Linear Array

Search Result 731, Processing Time 0.032 seconds

A Decorrelation Technique for Direction-of-Arrival Estimation of Coherent Signals (Coherent 신호의 입사방향 추정을 위한 상관관계 제거 기법)

  • Park, Geun-Ho;Shin, Jong-Woo;Kim, Hyoung-Nam
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.8
    • /
    • pp.95-104
    • /
    • 2016
  • Subspace-based direction-of-arrival (DOA) estimation algorithms have a difficulty in dealing with coherent signals caused by multi-path environment. As one of attempts to solve this problem, a spatial differencing method is known to be useful for not only estimating DOAs of the coherent signals but also improving the number of resolvable wavefronts even more than the number of antenna elements. However, since the conventional spatial differencing method uses only the partial statistics of the observed data, this method suffers from the performance degradation in estimation accuracy caused by the residual correlation between the uncorrelated signals. To cope with this problem, in this paper, a generalized spatial differencing method is proposed. Unlike the conventional method, the proposed method utilizes the entire statistics of the received signals. Therefore, the additional performance enhancement in both estimation accuracy and the number of resolvable wavefronts can be achieved. The performance analyses with computer simulations show that the proposed method outperforms the conventional method in terms of the estimation accuracy and the number of resolvable wavefronts.

Analysis on performance of grid-free compressive beamforming based on experiment (실험 기반 무격자 압축 빔형성 성능 분석)

  • Shin, Myoungin;Cho, Youngbin;Choo, Youngmin;Lee, Keunhwa;Hong, Jungpyo;Kim, Seongil;Hong, Wooyoung
    • The Journal of the Acoustical Society of Korea
    • /
    • v.39 no.3
    • /
    • pp.179-190
    • /
    • 2020
  • In this paper, we estimated the Direction of Arrival (DOA) using Conventional BeamForming (CBF), adaptive beamforming and compressive beamforming. Minimum Variance Distortionless Response (MVDR) and Multiple Signal Classification (MUSIC) are used as the adaptive beamforming, and grid-free compressive sensing is applied for the compressive sensing beamforming. Theoretical background and limitations of each technique are introduced, and the performance of each technique is compared through simulation and real experiments. The real experiments are conducted in the presence of reflected signal, transmitting a sound using two speakers and receiving acoustic data through a linear array consisting of eight microphones. Simulation and experimental results show that the adaptive beamforming and the grid-free compressive beamforming have a higher resolution than conventional beamforming when there are uncorrelated signals. On the other hand, the performance of the adaptive beamforming is degraded by the reflected signals whereas the grid-free compressive beamforming still improves the conventional beamforming resolution regardless of reflected signal presence.

Investigation of Radiation Effects on the Signal and Noise Characteristics in Digital Radiography (디지털 래디오그라피의 신호 및 잡음 특성에 대한 방사선 영향에 관한 연구)

  • Kim, Ho-Kyung;Cho, Min-Kook;Graeve, Thorsten
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.6
    • /
    • pp.756-767
    • /
    • 2007
  • For the combination of phosphor screens having various thicknesses and a photodiode array manufactured by complementary metal-oxide-semiconductor (CMOS) process, we report the observation of image-quality degradation under the irradiation of 45-kVp spectrum x rays. The image quality was assessed in terms of dark pixel signal, dynamic range, modulation-transfer function (MTF), noise-power spectrum (NPS), and detective quantum efficiency (DQE). For the accumulation of the absorbed dose, the radiation-induced increase both in dark signal and noise resulted in the gradual reduction in dynamic range. While the MTF was only slightly affected by the total ionizing dose, the noise power in the case of $Min-R^{TM}$ screen, which is the thinnest one among the considered screens in this study, became larger as the total dose was increased. This is caused by incomplete correction of the dark current fixed-pattern noise. In addition, the increase tendency in NPS was independent of the spatial frequency. For the cascaded model analysis, the additional noise source is from direct absorption of x-ray photons. The change in NPS with respect to the total dose degrades the DQE. However, with carefully updated and applied correction, we can overcome the detrimental effects of increased dark current on NPS and DQE. This study gives an initial motivation that the periodic monitoring of the image-quality degradation is an important issue for the long-term and healthy use of digital x-ray imaging detectors.

A Study for Analytical Method of Sudan Colorants in Foods (식품 중 수단색소의 분석법에 관한 연구)

  • 김희연;윤혜정;최장덕;최우정;박선영;이경주;김지혜
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.33 no.3
    • /
    • pp.549-552
    • /
    • 2004
  • A simple, efficient and accurate method was developed for the simultaneous determination of non-permitted oil soluble colorants (sudan I, II, III and IV) in foods. The identification has been carried out for sudan colorants by TLC as well as HPLC with photodiode array (PDA) detection. Separation of sudan colorants was achieved within 20 min by a gradient elution with water and acetonitrile as eluents. Sudan colorants showed good linear relationships in the range of 0.1 ~ 100 $\mu\textrm{g}$/mL. The correlation coefficients of the calibration curve for sudan colorants exceeded 0.999. The detection limits (signal-to-noise ratio 3 : 1) for sudan I, II, III and IV were 0.01, 0.01, 0.02 and 0.02 $\mu\textrm{g}$/mL, respectively. This method has been successfully applied to the analysis of red pepper powder, Kimchi and Kakdugi, and the average recoveries for real samples ranged from 83.02% to 104.3%.

Simultaneous Determination of Six Bioactive Components in Guibi-tang by HPLC-DAD (HPLC-DAD를 이용한 귀비탕 중 6종 생리활성 물질의 동시분석법 확립)

  • Yang, Hye-Jin;Weon, Jin-Bae;Ma, Jin-Yeul;Ma, Choong-Je
    • Korean Journal of Pharmacognosy
    • /
    • v.41 no.4
    • /
    • pp.313-318
    • /
    • 2010
  • Guibi-tang, a traditional herbal medicine, is used for anti-oxidant, anti-osteoporosis, hemostasis and gastroprotection. To develop an analysis method of simultaneous determination of six compounds, swertisin, decursinol, glycyrrhizin, 6-gingerol, costunolide and decursin in Guibi-tang, a high performance liquid chromatography was used with diode array detector. Six bioactive components were separated on a SHISEIDO $C_{18}$ column ($5\;{\mu}m$, 4.6 mm I.D.${\times}$250 mm) with column temperature $30^{\circ}C$. The gradient elution was composed of water with 0.1% trifluoroacetic acid (TFA) and acetonitrile. UV wavelength was set at 230 nm, 254 nm and 330 nm, respectively. Calibration curve showed good linear regression ($R^2$ > 0.9999). The limits of detection (LOD) and the limits of quantification (LOQ) ranged in 0.03 - 0.23 ${\mu}g/ml$ and 0.08 - $0.70\;{\mu}g/ml$, respectively. The RSD values of intra- and inter-day test were in the range of 0.03 ~ 0.96% and 0.01 ~ 1.46%, respectively. The evaluated results of accuracy test were varied from 92.28% ~ 105.14% with RSD < 1.60%. In conclusion, this developed simultaneous determination method was accuracy and sensitive to the quality evaluation of Guibi-tang.

Standardization of the Important Test Parameters in the Solder Ball Shear Test for Evaluation of the Mechanical Joint Strength

  • Kim J. W.;Koo J. M.;Lee W. B.;Moon W. C.;Moon J. H.;Yeon Y. M.;Shur C. C.;Jung S. B.
    • International Journal of Korean Welding Society
    • /
    • v.5 no.1
    • /
    • pp.15-28
    • /
    • 2005
  • The ball shear test was investigated in terms of the effects of test parameters, i.e., shear height and shear speed, with an experimental and non-linear finite element analysis for evaluating the solder joint integrity of area array packages. Two representative Pb-free solder compositions were examined in this work: Sn-3.5Ag-0.75Cu and In-48Sn. The substrate was a common SMD type with solder bond pad openings of 460 $\mu$m in diameter. The microstructural investigations were carried out using SEM, and the IMCs were identified with EDS. Shear tests were conducted with the two varying test parameters. It could be observed that increasing shear height, at fixed shear speed, has the effect of decreasing shear force for both Sn-3.5Ag-0.75Cu and In-48Sn solder joints, while the shear force increased with increasing shear speed at fixed shear height. Too high shear height could cause some undesirable effects on the test results such as unexpected high standard deviation values or shear tip sliding from the solder ball. The low shear height conditions were favorable for screening the type of brittle interfacial fractures or the degraded layers in the interfaces. The shear speed conditions were discussed with the stress analyses of the solder ball, and we cannot find any conspicuous finding which is related to optimum shear speed from the stress analyses.

  • PDF

Optimization of GTAW Parameters for Horizontal Welding of a STS316L Pipe (STS316L 강관의 수평자세 용접을 위한 GTAW 용접조건의 최적화)

  • Lee, Hyoung-Keun;Bang, Kyoung-Sik
    • Journal of Welding and Joining
    • /
    • v.33 no.5
    • /
    • pp.47-52
    • /
    • 2015
  • In this study, it was tried to analyze the effects of welding parameters on the weld penetration and aspect ratio when a STS316L pipe was welded in a horizontal position by GTAW. Experiments were systematically designed using a L18 orthogonal array, and the effects of welding parameters were statistically analyzed by ANOVA(Analysis of Variance). The shielding gas type has the largest effect on both the penetration and aspect ratio. The welding current type and shielding gas flow rate have a little effect on the penetration, whereas the electrode tip angle has a little effect on the aspect ratio. When welded at a selected welding condition, which is composed of He shielding gas, pulse current of 300/45 A, electrode tip angle of 90o, and shielding gas flow rate of 30 l/min, the estimated interval at least 95 % confidence was $1.99{\pm}0.18mm$ for the penetration and $0.31{\pm}0.04$ for the aspect ratio. From the confirmation experiments, the average penetration and aspect ratio were well agreed with the estimation as 1.96 mm and 0.30, respectively. Additionally, the effects of the welding speed and welding current on the penetration and aspect ratio were experimented and analyzed by linear regression. The penetration was linearly increased with the decrease of the welding speed and with the increase of the welding current, but the aspect ratio showed a tendency to a little decrease with the increase of both the welding speed and current.

The Study of the Geometric Structure Optimization for the Stereo X-ray Inspection System Using the Calibration (Calibration을 통한 스테레오 X-ray 검색장치의 기하구조 최적화 연구)

  • Hwang, Young-Gwan;Lee, Nam-Ho;Lee, Seung-Min;Park, Jong-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.9
    • /
    • pp.3422-3427
    • /
    • 2010
  • In this paper, we presents a sensor calibration technique using stereo X-ray images to provide efficient inspection of fast moving cargo objects. Stereo X-ray scanned images are acquired from a specially designed equipment which consists of a X-ray source, dual-linear array detector, and a conveyor system. Dual detector is installed so that rectified stereo X-ray images of objects are acquired. Using the stereo X-ray images, we carry out a sensor calibration to find the correspondences between the images and reconstruct 3-D shapes of real objects. Using the Image acquired from the stereo detectors with varying distances, we calculated the GCP(ground control point)of the image. And we figure out the error by comparing calculated GCP and GCP of the real object. The experimental results show the proposed technique can enhance the accuracy of stereo matching and give more efficient visualization for cargo inspection image.

An Analysis for Process Parameters in the Automatic $CO_2$ Welding Using the Taguchi Method (다구찌 방법을 이용한 $CO_2$ 자동용접의 공정변수 분석)

  • 김인주;박창언;김일수;성백섭;손준식;유관종;김학형
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.596-599
    • /
    • 2004
  • The robotic $CO_2$ welding is a manufacturing process to produce high quality joints for metal and it could provide a capability of full automation to enhance productivity. Despite the widespread use in the various manufacturing industries, the full automation of the robotic $CO_2$ welding has not yet been achieved partly because the mathematical model for the process parameters of a given welding task is not fully understood and quantified. Several mathematical models to control welding quality, productivity, microstructure and weld properties in arc welding processes have been studied. However, it is not an easy task to apply them to the various practical situations because the relationship between the process parameters and the bead geometry is non-linear and also they are usually dependent on the specific experimental results. Practically, it is difficult, but important to know how to establish a mathematical model that can predict the result of the actual welding process and how to select the optimum welding condition under a certain constraint. In this research, an attempt has been made to develop an intelligent algorithm to predict the weld geometry (top-bead width, top-bead height, back-bead width and back-bead height) as a function of key process parameters in the robotic $CO_2$welding. To achieve this above objective, Taguchi method was employed using five different process parameters (tip gap, gas flow rate, welding speed, arc current, welding voltage) as a guide for optimization of process parameters.

  • PDF

High Performance Coprocessor Architecture for Real-Time Dense Disparity Map (실시간 Dense Disparity Map 추출을 위한 고성능 가속기 구조 설계)

  • Kim, Cheong-Ghil;Srini, Vason P.;Kim, Shin-Dug
    • The KIPS Transactions:PartA
    • /
    • v.14A no.5
    • /
    • pp.301-308
    • /
    • 2007
  • This paper proposes high performance coprocessor architecture for real time dense disparity computation based on a phase-based binocular stereo matching technique called local weighted phase-correlation(LWPC). The algorithm combines the robustness of wavelet based phase difference methods and the basic control strategy of phase correlation methods, which consists of 4 stages. For parallel and efficient hardware implementation, the proposed architecture employs SIMD(Single Instruction Multiple Data Stream) architecture for each functional stage and all stages work on pipelined mode. Such that the newly devised pipelined linear array processor is optimized for the case of row-column image processing eliminating the need for transposed memory while preserving generality and high throughput. The proposed architecture is implemented with Xilinx HDL tool and the required hardware resources are calculated in terms of look up tables, flip flops, slices, and the amount of memory. The result shows the possibility that the proposed architecture can be integrated into one chip while maintaining the processing speed at video rate.