Behavior of self supported transmission line towers under stationary downburst loading

  • Darwish, Mohamed M.;El Damatty, Ashraf A.
    • Wind and Structures
    • /
    • v.14 no.5
    • /
    • pp.481-498
    • /
    • 2011
  • During the past decade, many electrical transmission tower structures have failed during downburst events. This study is a part of a research program aimed to understand the behaviour of transmission lines under such localized wind events. The present study focuses on assessing the behaviour of self supported transmission line towers under downburst loading. A parametric study is performed to determine the critical downburst configurations causing maximum axial forces for various members of a tower. The sensitivity of the internal forces developing in the tower's members to changes in the downburst size and location was studied. The structural behaviour associated with the critical downburst configurations is described and compared to the behaviour under 'normal' wind loads.

A Study on Mooring Limit Analysis of Large Ship (대형 선박의 계류한계에 대한 연구)

  • KIM, Won-Ouk;LEE, Sung-Wook;BAE, Jun-Young
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.29 no.2
    • /
    • pp.415-421
    • /
    • 2017
  • This study is aiming to find one of working conditions for loading and unloading a large ship at game port. Firstly, for dynamic analysis of the moored ships, the motion characteristics of ship according to loading condition are figured out. The motion characteristics of ship is related to environmental factors such as current, wind, mooring line, fender and etc. As a result, it is ascertained through numerical simulation using the AQUA MARINE developed by ANSYS INC. This study might contribute to make a new method of mooring stability of target ship.

Post-liquefaction Behavior under Monotonic Loading of a Silty Sand (실트질 모래의 액상화 후의 정적거동)

  • 강병희;박근보;강대성
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.5
    • /
    • pp.27-36
    • /
    • 2000
  • 보통으로 다져진(Dr=50%)실트질 모래의 액상화 후의 비배수정적거동과 이에 대한 압밀응력비의 영향에 관해서 연구하기 위하여 4가지 압밀응력비(σhc'/σVC'=1.0,0.7,0.55,K0)로서 압밀시킨 공시체를 액상화 전후상태에서 비배수 삼축시험을 수행하였다. 연구결과 액상화를 경험하지 않은 실트질 모래의 p'-q좌표상의 상전이선과 파괴선은 모두 구속압밀응력과 압밀응력비의 크기에 관계없이 각각 원점을 지나는 하나의 직선으로 나타난다. 또한 상정이전단저항은 구속응력이 클수록 증가하난 동일한 구속응력하에서는 압밀응력비와는 관계없이 거의 동일한 값을 갖는 경향을 나타낸다.

  • PDF

Analysis of Elasto-Plastic Dynamic Behaviour of Plate Subjected to Load by Low Velocity Impact (저속충격 하중을 받는 판의 탄소성 동적거동 해석)

  • Huh, Gyoung-Jae;Dokko, Wook
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.11
    • /
    • pp.158-164
    • /
    • 2000
  • In this study a computer program is developed for analyzing the elasto-plastic dynamic behaviors of the plate subjected to line-loading by a low-velocity impactor. The equilibrium equation associated with the Hertzian contact law is formulated to evaluate the transient dynamic behaviour of the impacted plate. Compared with an elastic analysis, the effects of material plasticity are presented. Consequently, in the case of elasto-plastic analysys, impulse decreases, displacements increase and contact time duration is longer than the elastic case for same finite element model. And the time variation of the impacting load is not significant due to the plasticity except at the beginning of impact duration, and the induced stresses of the plate are more realistic.

  • PDF

Study of Vitrification of Immatured Pig Oocytes: Compared with Open Pulled Straw(OPS), Electron Microscopic Grid(EMG) and Nylon Loop System(NLS) (미성숙 돼지 난자의 유리화 동결에 관한 연구: Open Pulled Straw(OPS), Electron Microscopic Grid(EMG) 및 Nylon Loop System(NLS)의 비교)

  • 김인덕;안미현;석호봉
    • Journal of Embryo Transfer
    • /
    • v.19 no.1
    • /
    • pp.27-34
    • /
    • 2004
  • This study evaluated the efficiency and compared with different materials of loading vessels for vitrification-plastic/glass, copper grid and nylon. The loading method, vitrification, cryop-reservation and warming method of the oocytes were examined. The loading samples prepared in manual or company-made and sterilized, loaded the COCs selected on each samples and cultured for maturation during 40 hours, and then exposed sequentially to ethylene glycol solution. Thawing method was reversely treated and exposed for warmed oocytes. After oocytes were thawed, fertilized and cultured in vitro for 3-4 hours, rates of development and morphological appearance were examined. The results were as summarized: ㆍOPS from company-made or hand-made of the hematocrit micropipettes, NLS from fishing line and EMG from company-made for EM were used for loading oocytes, respectively. ㆍThe efficiency of freezing method and loading convenience were orderly higher in OPS, NLS and EMG. The optimal capacity per vessel was orderly lowered in NLS, EMG and OPS, respectively. ㆍAfter oocytes were warmed, the recovery rate, morphology and rate of development were orderly higher in OPS, NLS and EMG, respectively. ㆍIn conclusion, OPS has the advantages of achieving a little more survival and preserving results than other two loading methods.

Risk assessment of transmission line structures under severe thunderstorms

  • Li, C.Q.
    • Structural Engineering and Mechanics
    • /
    • v.6 no.7
    • /
    • pp.773-784
    • /
    • 1998
  • To assess the collapse risk of transmission line structures subject to natural hazards, it is important to identify what hazard may cause the structural collapse. In Australia and many other countries, a large proportion of failures of transmission line structures are caused by severe thunderstorms. Because the wind loads generated by thunderstorms are not only random but time-variant as well, a time-dependent structural reliability approach for the risk assessment of transmission line structures is essential. However, a lack of appropriate stochastic models for thunderstorm winds usually makes this kind of analysis impossible. The intention of the paper is to propose a stochastic model that could realistically and accurately simulate wind loading due to severe thunderstorms. With the proposed thunderstorm model, the collapse risk of transmission line structures under severe thunderstorms is assessed numerically based on the computed failure probability of the structure.

A Novel Line Stability Index for Voltage Stability Analysis and Contingency Ranking in Power System Using Fuzzy Based Load Flow

  • Kanimozhi, R.;Selvi, K.
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.4
    • /
    • pp.694-703
    • /
    • 2013
  • In electric power system, the line stability indices adopted in most of the instances laid stress on variation of reactive power than real power variation of the transmission line. In this paper, a proposal is made with the formulation of a New Voltage Stability Index (NVSI) which originates from the equation of a two bus network, neglecting the resistance of transmission line, resulting in appreciable variations in both real and reactive loading. The efficacy of the index and fuzzy based load flow are validated with IEEE 30 bus and Tamil Nadu Electricity Board (TNEB) 69 bus system, a practical system in India. The results could prove that the identification of weak bus and critical line in both systems is effectively done. The weak area of the practical system and the contingency ranking with overloading either line or generator outages are found by conducting contingency analysis using NVSI.

Finite element stress analysis on supporting bone by tripodal placement of implant fixture (유한요소법을 이용한 임플란트 고정체의 삼각배열에 따른 지지골의 응력 분석)

  • Son, Sung-Sik;Lee, Myung-Kon
    • Journal of Technologic Dentistry
    • /
    • v.31 no.1
    • /
    • pp.7-15
    • /
    • 2009
  • Purpose: This study was to propose the clear understanding for stress distribution of supporting bone by use of staggered buccal offset tripodal placement of fixtures of posterior 3 crown implant partial dentures. We realized posterior 3 crown implant fixed partial dentures through finite element modeling and analysed stress effect of implant arrangement location to supporting bone under external load using finite element method. Method: To understand stress distribution of 3 crown implant fixed partial dentures which have 2 different arrangement by finite element analysis. In each model, for loading condition, we applied $45^{\circ}$ oblique load to occlusal surface of crown and applied 100 N for 3 crown individually(total 300 N) for imitating possible oral loading condition. at this time, we calculated Von Mises stress distribution in supporting bone through finite element method. Result: When apply $45^{\circ}$ oblique load to in-line arrangement model, maximum stress result for 100 N for each 3 crown 47.566MPa. In tripodal placement, result for 1mm buccal offset tripodal placement implant model was maximum distributed load 51.418MPa, so result was higher than in-line arrangement model. Conclusion: In stress distribution result by placement of implant fixture, the most effective structure was in-line arrangement. The tripodal placement does not effective for stress distribution, gap cause more damage to supporting bone.

  • PDF

Analysis of the Sleeve Dipole Array Antennas Using the Moment Method (모멘트 법을 이용한 슬리브 다이폴 배열안테나의 해석)

  • 배남진;최학근
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.7
    • /
    • pp.973-984
    • /
    • 1999
  • This paper presents a method of moments with the transmission line theory to analyze the sleeve dipole array antennas and analyses characteristics of that. There were several considerations for analysis of the method of moments. First, the method of moments were applied at both of the sleeve dipole elements and the coaxial line because the current flows on both of them. Second, the feed voltages of each sleeve dipole element were obtained by using a transmission line theory because the feeding structure is fed by coaxial line in series. Third, the series reactance between the coaxial line and the open side of the sleeve was considered as impedance loading on the antenna. The radiation patterns and current distributions from the numerical results were considered as variation of the feed distances and frequencies. To verify the validity of our method, 4 elements sleeve dipole array antennas with 1 λg distance were fabricated and measured, and then the measured radiation patterns were compared with the numerical results. The measured results were confirmed a good agreement with the numerical results.

  • PDF