• Title/Summary/Keyword: Line-and-Space

Search Result 2,347, Processing Time 0.029 seconds

A Study on the Job Ability of Industrial Health Service Agency Members - with the Focus on the Industrial Health Service Agency in Seoul and Kyungki - (산업보건관리자의 직무능력에 관한 연구 - 서울$\cdot$경기 지역의 산업보건센타를 중심으로)

  • Kwon Soon Ju
    • Journal of Korean Public Health Nursing
    • /
    • v.10 no.2
    • /
    • pp.37-50
    • /
    • 1996
  • To analyze the roles by abilities between manpower through the analysis of industrial health service agency personnel, 115 industrial health service agency personnel in 19 Industrial Health Service Agency personnel scattered in Seoul and Kyungki areas have been investigated according to the questionnaires formulated in line with the Likert 5-point scale from September 1 through October 30, 1995 and the following significant result has been obtained: 1. The job abilities by fields. 1) In the field of health care, the level of medical personnel's job ability was 3.30 on average and that of industrial hygienists' was 2.54 on average, which showed that the level of medical personnel's job ability was higher. 2) In the field of health management, there was a difference between the level of medical personnel's job ability and that of industrial hygienists' only in the health education but there was not so much difference between manpower' which showed that it was 3.00 on average. 3) In the field of working environment management. the level of industrial hygienists' job ability was 4.03 on average and that of medical personnel's was 2.62, which showed that the level of industrial hygienists' job ability was higher than that of medical personnel's. 2. The job abilities by manpower. As for the job ability by manpower. on the health care the medical personnel's ability was more excellent than the industrial hygienists' and on the working environment management the latter's{industrial hygienists') ability was more excellent than the former's(the medical personnel's). However. the field that a difference between both manpower as mentioned above was not recognized was the health management. 3. As for the difference of potential factors between manpower. in Factor '1' the industrial hygienists' 80.7 points by percentage was higher than the medical personnel's 52.5 points and in Factor '2' the latter's(medical personnels's) 72.6 points by percentage was higher than the former's{industrial hygienists') 50.6 points in the level of job abilities. The above result shows that the industrial health service agency personnel can be classified into the job with a difference between manpower and that without any difference manpower. Therefore, the following issues: First: The field of health care shall be defined as the medical personnel's exclusive job. Second: The field of working environment management shall be defined as the industrial hygienists' exclusive job. Third: The field of health management shall be defined as a common job to lead the limits of time and space in the collective group occupational health management to be controlled effectively.

  • PDF

Analysis of Fire Scenarios and Evaluation of Risks that might Occur in Operation Stage of CAES Storage Cavern (CAES 저장 공동 운영단계에서 발생 가능한 리스크 평가 및 화재 시나리오 분석)

  • Yoon, Yong-Kyun;Ju, Eun-Hye;Seo, Saem-Mul;Choi, Byung-Hee
    • Tunnel and Underground Space
    • /
    • v.25 no.1
    • /
    • pp.107-114
    • /
    • 2015
  • This study focuses on assessing risks which might occur in operation stage of CAES storage cavern and analyzing fire scenarios for the risk that have been assessed with highest risk level. Risks in operation stage were categorized into upper risk group and lower risk group. Components of upper risk group are technical risk, facility risk and natural disaster risk. Lower risk group is composed of 11 sub-risks. 20 experts were chosen to survey questionnaires. ANP model was applied to analyze the relative importance of 11 sub-risks. Results of risk analysis were compared with risk criterion to set risk priorities, and the highest risk was determined to be 'occurrence of the fire within the management opening'. Three fire scenarios were developed for the highest risk level and FDS (Fire dynamics Simulator) was used to analyze these scenarios. No. 3 scenario which air blows from tunnel into outside atmosphere represented that a rate of smoke spread was the fastest among three fire scenarios and a smoke descended most quickly below the limit line of breathing. Thus, No. 3 scenario turned out to be the most unfavorable condition when operating staffs were evacuated from access tunnel.

Estimation of Safety in Railway Tunnel by Using Quantitative Risk Assessment (QRA를 이용한 철도터널 방재 안전성 평가)

  • Kim, Do-Sik;Kim, Do-Hyung;Kim, Woo-Sung;Lee, Du-Hwa;Lee, Ho-Seok
    • Tunnel and Underground Space
    • /
    • v.16 no.5 s.64
    • /
    • pp.357-367
    • /
    • 2006
  • Recently, as the construction of new railway and the relocation of existing line increase, tunnel structures grow longer. The railway fire accidents in long tunnel bring large damages of human life and disaster. The interest of safety in long tunnel have a growing and the safety standard of long tunnel is tightening. For that reason, at the planning of long tunnel, the optimum design of safety facility in long tunnel for minimizing the risks and satisfying the safety standard is needed. For the reasonable design of long railway tunnel considering high safety, qualitative estimation for tunnel safety is required. In this study, QRA (Quantitative Risk Assessment) technique is applied to design of long railway tunnel for assuring the safety function and estimating the risk of safety. The case study for safety design in long railway tunnel is tarried out to verifying the QRA technique for two railway tunnels. Thus, the inclined and vertical shaft for escape way and safety facilities in long tunnel are planned, and the risks of tunnel safety for each case are estimated quantitatively.

Analysis of the Optimal Degree and Order of Spherical Harmonics for the GNSS Receiver Antenna's PCV Correction (GNSS 수신기 안테나의 PCV 보정 모델 산출을 위한 구면조화함수 최적차수 분석)

  • Kim, Jin Yi;Won, Ji Hye;Park, Kwan Dong;Seo, Seung Woo;Park, Heung Won
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.22 no.3
    • /
    • pp.113-119
    • /
    • 2014
  • The positioning accuracy of GNSS surveys deteriorates due to various error factor, and many users sometimes ignore Phase Center Variation (PCV) of antennas. IGS provides an ANTEX file which contains PCV correction information to correct for PCVs. But it is not directly applicable because PCV correction information is provided at 5-degree intervals in the azimuth and elevation directions for the case of receiver antennas, and at 1-degree intervals in the nadir angle for the case of satellite antennas. So, we devised new and optimal ways of interpolating PCV in any desired line of sight to the GNSS satellite. We used spherical harmonics fitting methods in terms of the azimuth and elevation angle for interpolation, and found an optimal degree and order. It is shown that the best accuracy was obtained from the 8 by 8 spherical harmonics. If one requires lower burden on computing resources, the order and degree less than 8 could produce resonable accuracy except for 1st and 5th order.

Implementation of 433/856MHz Dual Band Antenna Using IFA Structure (IFA 구조를 이용한 433/865MHz 이중대역 안테나의 구현)

  • Kang, Sang-Won;Sung, Ji-Hyun;Choe, Gwang-Je
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.3
    • /
    • pp.163-168
    • /
    • 2015
  • In this paper, 433/865MHz dual band antenna is proposed by using IFA structure of a PCB antenna, the performance was improved by changing of the space between the feed point and short strip, varying the gap between the radiator and the ground plane and adding the branch line in the proposed antenna. To confirm the characteristics of the antenna parameters, HFSS from ANSYS Inc. was used for the analysis. RFID frequency band of ISO-18000-7 is 433MHz and EU-RFID frequency band of ISO-18000-6 is from 865.5 to 867.5MHz. Each of the 433/865MHz bandwidth of the proposed antenna is 5.2MHz and 18.2MHz. The maximum 433MHz antenna gain is -5.74dBi, the maximum 865MHz antenna gain is -3.36dBi. The Jig size of the proposed antenna is $60{\times}44{\times}1mm$ and the size of the antenna area $44{\times}21mm$. The results proved the possibility of the practical use on 433/865MHz by using the IFA structure that came from comparing and analyzing the measured and simulated data of the antenna.

Design and Implementation of Electronic Culture Atlas Based on Google Earth (구글어스 기반의 전자문화지도 설계 및 구현)

  • Kang, Ji-Hoon;Moon, Sang-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.2
    • /
    • pp.357-363
    • /
    • 2014
  • The development of information technology grows the society and allows the user to generate more information and the requirements. According to recent growing interest in digital convergence technologies, digital convergence can be utilized by a variety of methods as a new study. Electronic culture atlas would be digitized cultural information that represents a particular area on the map. In detail, spatial data like as point, line, and area can be used to represent the culture information. Using electronic culture atlas, also, it is possible to provide and utilize information which is associated with time, space(map) and subject(culture). Thus, electronic culture atlas could be used as a method for the humanities or area studies and spread research results by displaying on the culture atlas. In general, existing electronic culture atlas used bitmap image mostly as a base map. Using bitmap image, it is difficult to represent to provide three-dimensional information of specific area. Also, it happens problem such as breakage occurs during zoom-in operation. To solve this problems, we design and implement electronic culture atlas based on Google Earth which is three-dimensional map service.

Numerical Analysis on Effect of Stemming Condition in Mine Ventilation Shaft Blasting (광산 통기수갱발파에서 전색조건이 발파효율에 미치는 영향에 관한 수치해석적 연구)

  • Kim, Jun-ha;Kim, Jung-gyu;Jung, Seung-won;Ko, Young-hun;Baluch, Khaqan;Kim, Jong-gwan
    • Explosives and Blasting
    • /
    • v.39 no.3
    • /
    • pp.15-23
    • /
    • 2021
  • Ventilation shafts are pathways in mines and tunnels for the removal of dust or smoke during underground space construction and operation. In mines, blasting with long blast holes is preferred for the excavation of a ventilation shaft in the 10~20m long crown pillar section. In this case, the bottom part of the blast hole is completely drilled in order to determine the drilling error, and this causes a problem of lowering the explosive charge and blasting efficiency. It is possible to solve the problem of explosive loading and to increase the blast efficiency by covering the curb of the blasthole by using stemming material. In this study, simulations for the blasting of a ventilation shaft were performed with various stemming lengths and the blasthole diameters(45, 76mm) using AUTODYN 2D SPH(Smooth particle hydrodynamics) analysis technique. Also the optimal bottom stemming column was derived by checking the size of the boulder and burden line according to blasting. Analysis result, blasting efficiency is lessened in case of stemming length less than 30cm and the optimal length of the stemming material should be 30cm or higher to achieve high efficiency of blasting.

Analysis of the factors of the failure of the North Korean Army's Great Bypass Maneuver to Honam during the Korea War from an indirect approach strategy: Focusing on the Naval and Marine Corps' Tongyeong Amphibious Operation to Stop the "Dislocation" (간접접근전략으로 본 6·25전쟁기 북한군의 호남 방면 대우회기동 실패 요인 분석 -'교란'을 저지한 해군·해병대의 통영상륙작전을 중심으로-)

  • Choi, Ho-jae
    • Maritime Security
    • /
    • v.6 no.1
    • /
    • pp.109-135
    • /
    • 2023
  • The North Korean military's maneuver toward Honam was the fastest maneuver the North Korean army had demonstrated during the Korean War, and it was a threatening attack that forced the Korean and Allied forces to fully adjust the defenses of the Nakdong River. However, when this study analyzed the North Korean military's maneuver toward Honam in terms of indirect approach strategy, there were a number of factors that inevitably led to its failure. In terms of implementing the indirect approach strategy, the North Korean military cited a number of failure factors, including the dispersion of combat forces, the inflexibility of changing the line of operation, the maneuvering of ground forces, and the lack of psychological distaction. However, the North Koreans were preparing for a final "surprise attack," in which the 7th Division, which was following the North Korean 6th Division, took another diversion and attempted to attack in the direction of Tongyeong. With this, the North Koreans intended to break through the Nakdong River defenses and head for Pusan. However, the North Korean attack was ultimately thwarted by the Korean Navy and Marine Corps' Tongyeong Amphibious Operation. With a swift maneuver using the sea as a maneuvering space, the Navy and Marine Corps occupied key points first, creating an advantageous situation and fending off an attack by the North Korean 7th Division. The Navy and Marine Corps' Tongyeong Amphibious Operation finally thwarted the North Korean military's maneuver toward Honam, thus maintaining the Nakdong River defenses.

  • PDF

H-Plane 8-Way Rectangular Waveguide Power Divider Using Y-Junction (Y-Junction을 이용한 H-평면 8-Way 구형 도파관 전력 분배기)

  • Lee, Sang-Heun;Yoon, Ji-Hwan;Yoon, Young-Joong;Kim, Jun-Yeon;Lee, Woo-Sang;Park, Seul-Gi
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.2
    • /
    • pp.151-158
    • /
    • 2012
  • This paper proposes a H-plane 8-way rectangular waveguide power divider using Y-junction. A general N-way power divider can be composed of multi-stage T-junctions. However, if the distances of output ports are close, the matching characteristic is not improved by using only T-junctions because of space limitation. In this case, since other types of 3-port junctions should be used to final output stage, Y-junctions are used with T-junctions in this paper. The proposed Y-junction uses the tapered-line impedance transformer and inductive irises to improve impedance matching characteristic. The 8-way power divider using Y-junction is fabricated and measured. The measured return loss and insertion loss from input port to output port are -30.8 dB and -9.3 dB at operating frequency, respectively. The measured maximum phase difference is about $1^{\circ}$. Therefore, the proposed power divider will be useful to apply to various microwave systems, which need to divide the input power equally, such as feed networks for array antennas.

The First Isolation of Chalamydia pneumoniae from a Korean Patient (한국인에서 처음 분리된 Chlamydia pneumoniae)

  • Lee, Seung-Joon;Jung, He-Hyeok;Kim, Suk-Kyeong;Choi, Dae-Hee;Han, Seon-Suk;Nam, Eui-Cheol;Won, Jun-Yeon;Park, Weon-Seo;Lee, Myung-Goo;Jung, Ki-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.53 no.5
    • /
    • pp.569-576
    • /
    • 2002
  • Background : Chlamydia pneumoniae is one of common causes in upper and lower respiratory infections. Isolating C. pneumoniae from clinical specimens is very difficult due to the characteristics of the organism. Recently, we succeeded in isolating C. pneumoniae from a Korean patient, who suffered from acute pharyngitis. This is the first isolate from a clinical specimen in Korea. Methods : We attained a nasopharyngeal swab from a 22-year-old female patient, and inoculated it on a monolayer of the Hep-2 cell line. After 8 passages, we found the inclusion bodies of C. pneumoniae by an immunofluorescence(IF) test. The species-specific monoclonal antibody IF staining and species-specific PCR were done to confirm the species of the isolate, and electron microscopy was used to characterize the morphology. Results : The isolated was confirmed to be C. pneumoniae by species-specific IF and PCR, and the strain was named LKK-1. The shape of the elementary body was round and with a narrow periplasmic space, as shown by electron microscopy, which is similar to the Japanese strain, but not the Western strain. Conclusion : We succeeded in isolating C. pneumoniae from a 22-year-old patient with acute pharyngitis, which is the first isolate in Korea. In the future, this Korean strain will be useful to the study of C. pneumoniae.