A Study on an Algorithm of Line Switching and Bus Separation for Alleviating Overloads by the Use of Line Power Tracing and Sensitivity (선로유효전력 Tracing과 민감도를 활용한 선로 과부하 해소 스위칭 및 모선분리 알고리즘에 관한 연구)

  • Lee, Byung-Ha;Hwang, Sung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.11
    • /
    • pp.2007-2016
    • /
    • 2011
  • In this paper, a new algorithm for alleviating overloads in power networks by the use of line power tracing and sensitivity is proposed to perform line switching and bus separation effectively. Also, a new bus separation index based on line power tracing is presented to find the bus to be separated for relieving overloads effectively. By applying the sensitivity of the line flow with respect to the change of the line impedance, both switching-on and switching-off of the lines for alleviating overloads in power networks are performed systematically at once. The number of the considered cases for line switching and bus separation can be greatly reduced and the best combination of line switching and bus separation can be acquired efficiently by the use of the sensitivity and the bus separation index. In order to show the effects of this algorithm, it is applied to a small scale power system of IEEE 39-bus system and practical power systems of KEPCO.

Power System State Estimation and Identification in Consideration of Line Switching (선로개폐상태를 포함하는 전력통계 상태추정및 동정)

  • 박영문;유석한
    • 전기의세계
    • /
    • v.28 no.3
    • /
    • pp.57-64
    • /
    • 1979
  • The static state estimation are divided into two groups; estimation and detection & identification. This paper centers on detection and identification algorithm. Especially, the identification of line errors is focused on and is performed by the extended W.L.S. algorithm with line swithching states. Here, line switching states mean the discrete values of line admittance which are influenced by unexpected line switching. The numerical results are obtained from the assumption that the noise vector is independent zero mean Gaussian random variables.

  • PDF

Airborne Antenna Switching Strategy Using Deep Learning on UAV Line-Of-Sight Datalink System

  • Jo, Se-Hyeon;Lee, Woo-Sin;Kim, Hack-Joon;Jin, So-Yeon;Yoo, In-Deok
    • Journal of the Korea Society of Computer and Information
    • /
    • v.23 no.12
    • /
    • pp.11-19
    • /
    • 2018
  • In the Unmanned Aerial Vehicle Line-Of-Sight datalink system, there is a possibility that the communication line is disconnected because line of sight can not be secured by one antenna due to changes in position and posture of the air vehicle. In order to prevent this, both top and bottom of air vehicle are equipped with antennas. At this time, if the signal can be transmitted and received by switching to an antenna advantageous for securing the line of sight, communication disconnection can be minimized. The legacy antenna switching method has disadvantages such that diffraction, fading due to the surface or obstacles, interference and reflection of the air vehicle are not considered, or antenna switching standard is not clear. In this paper, we propose an airborne antenna switching method for improving the performance of UAV LOS datalink system. In the antenna switching method, the performance of each of the upper and lower parts of the mounted antenna according to the position and attitude of the air vehicle is predicted by using the deep learning in an UAV LOS datalink system in which only the antenna except the receiver is duplicated. Simulation using flying test dataset shows that it is possible to switch antennas considering the position and attitude of unmanned aerial vehicle in the datalink system.

An Overload Alleviation Algorithm by Line Switching (선로절환에 의한 과부화 해소 앨고리즘)

  • 박규홍;정재길
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.5
    • /
    • pp.459-467
    • /
    • 1992
  • This paper presents a new algorithm for the countermeasure to alleviate the line overloads due to contingency without shedding loads in a power system. This method for relieving the line overloads by line switching is based on obtaining the kine outage distribution factors-the linear sensitivity factors, which give the amount of change in the power flow of each line due to the removal of a line in a power system. There factors are made up of the elements of sparse bus reactance matrix and brach reactances. In this paper a fast algorithm and program is presented for obtaining only the required bus reactance elements which corresponds to a non-zero elements of bus admittance matrix, and elements of columns which correspond to two terminal buses of the overloaded(monitored) line. The proposed algorithm has been validated in tests on a 6-bus and the 30-bus test system.

  • PDF

A Study on the Affecting Factors and Effects of Switching Costs in On-line shopping mall (온라인 쇼핑몰 전환비용의 영향 요인과 효과에 관한 연구)

  • Han, Pil Koo;Kang, Seong Chul;Jun, Byoung Ho
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.7 no.3
    • /
    • pp.137-150
    • /
    • 2011
  • Long-term customer retention strategies with switching cost is very important for gaining a competitive advantage in on-line shopping mall environment. The purpose of this study is to investigate the affecting factors of switching cost in terms of on-line shopping mall's quality and the effects of it on customers' behavior moderating commitment. According to the result, information quality and customized information were found to be significantly related to social switching cost, and also royalty program and product differentiation were found to be significantly related to lost benefit cost and procedural cost respectively. When it comes to the relationship between switching cost and commitment, results shows that social switching cost is not significantly related to affective commitment. Lost benefit cost and procedural cost, however, were found to be significantly related to affective commitment and calculative commitment respectively. Finally, affective commitment was found to bolster repurchase intention and control negative WOM, and calculative commitment was found to bolster both repurchase intention and negative WOM.

Series-Gap Characteristics of Transmission Line Arrester with Switching and Lightning Impulse Flashover Test (개폐서지 및 뇌충격 섬락시험에 따른 송전 피뢰기의 직렬공극 특성)

  • Cho, Han-Goo;Yoo, Dae-Hoon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.484-485
    • /
    • 2007
  • This paper describes the series-gap characteristics of transmission line arrester with switching and lightning impulse flashover test. The transmission line arrester exhibited external gap because it is must not flashover with switching impulse on the other hand it is must flashover with lightning impulse. In accordance, minimum and maximum length of series-gap was determinated with these tests. As gap length is increased flashover voltage was increased in the range of 315.4 kV~496.3 kV and negative polarity exhibited a high voltage. As a result, It was thought tat the series-gap length of transmission line arrester exhibited in the range of 580 mm~1100 mm.

  • PDF

A Conduction Band Control AC-DC Buck Converter for a High Efficiency and High Power Density Adapter (고효율, 고전력밀도 아답터를 위한 도통밴드 제어 AC-DC 벅 컨버터)

  • Moon, SangCheol;Chung, Bonggeun;Koo, Gwanbon
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.38-39
    • /
    • 2017
  • This paper proposes a new control method for an AC-DC Buck converter which is utilized as a front-end converter of a 2-stage high power density adapter. In the conventional adapter applications, 2-stage configuration shows higher power transfer efficiency and higher power density than those of the single stage flyback converter. In the 2-stage AC-DC converter, the boost converter is widely used as a front-end converter. However, an efficiency variation between high AC line and low AC line is large. On the other hand, the proposed conduction band control method for a buck front-end converter has an advantage of small efficiency variation. In the proposed control method, switching operation is determined by a band control voltage which represents output load condition, and an AC line voltage. If the output load increasesin low AC line, the switching operation range is expanded in half of line cycle. On the contrary, in light load and high line condition, the switching operation is narrowed. Thus, the proposed control method reduces switching loss under high AC line and light load condition. A 60W prototype which is configured the buck and LLC converter with the proposed control method is experimented on to verify the validity of the proposed system. The prototype shows 92.16% of AC-DC overall efficiency and 20.19 W/in 3 of power density.

  • PDF

The Originating Characteristics of Periodic Impulse Noises in the Data Communication System by Distribution Line Carrier Method (배전선반송 데이타통신에서의 주기적 임펄스노이즈의 발생특성)

  • 최순만;노창주
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.18 no.2
    • /
    • pp.75-82
    • /
    • 1994
  • The existence of peroodic impulse noises in distribution line carrier (DLC) communication system is known to be the most serious obstacle for improving DLC communication quality in reliability and capacity. From the spectral points, impulse noises can be divided into baseband type and modulation type the noise width of whichs are much different each other. With each nose type, this study presents the basic characteristics in relation to what they originate from and how their spectrum properties are revealed. The baseband type impulse noise is normally caused from thyristor circuit running with low switching speed and the modulation type noise from the circuit of switching power supply. The base wave of modulation noise is shown to be the pulsuatic charging current to primary condenser in switching power circuit. The study result indicates also that placing the DLC carrier frequency away the band predominated by modulated noise especially from RCC type switching power circuit is very important in DLC design.

  • PDF

High Efficiency Control Strategy of TNPC Inverter Using Low-frequency Switching Method of Neutral Point Switch (중성점 스위치의 저주파 스위칭 기법을 이용한 TNPC 인버터의 효율 향상 기법)

  • Lee, Taeyeong;Cho, Younghoon;Lim, Seungbeom
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.329-330
    • /
    • 2015
  • This paper introduces a low-frequency switching method for the neutral line of TNPC inverters to achieve high efficiency. By applying the method, the switching loss in the neutral line is reduced. In order to compensate the current distortion near zero-crossing points, the partial switching strategy is applied. Both the simulation and the experimental results verify the usefulness of the proposed method.

  • PDF

Series-Gap Characteristics of Polymeric Arrester for Transmission Line (송전선로용 폴리머 피뢰기의 직렬공극 특성)

  • Cho, Han-Goo;Yoo, Dae-Hoon;Lee, Young-Sun;Kim, Jong-Che
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.491-492
    • /
    • 2008
  • This paper describes the series-gap characteristics of transmission line arrester with switching and lightning impulse flashover test. The transmission line arrester exhibited external gap because it is must not flashover with switching impulse on the other hand it is must flashover with lightning impulse. In accordance, minimum and maximum length of series-gap was determinated with these tests. As gap length is increased flashover voltage was increased in the range of 315.4 kV~496.3 kV and negative polarity exhibited a high voltage. As a result, It was thought tat the series-gap length of transmission line arrester exhibited in the range of 580 mm~1100 mm.

  • PDF