• 제목/요약/키워드: Line drop compensation(LDC)

검색결과 12건 처리시간 0.037초

배전계통의 전압조정기 운영방법에 따른 분산형전원 최대 도입 용량 산출 (The Maximum Installable DG Capacity According to Operation Methods of Voltage Regulator in Distribution Systems)

  • 김미영
    • 전기학회논문지
    • /
    • 제58권7호
    • /
    • pp.1263-1269
    • /
    • 2009
  • Stable and sustainable power supply means maintaining a certain level of power quality and service while securing energy resource and resolving environmental issues. Distributed generation (DG) has become an essential and indispensable element from environmental and energy security perspectives. It is known that voltage violation is the most important constraint for load variation and the maximum allowable DG. In distribution system, sending voltage from distribution substation is regulated by ULTC (Under Load Tap Changer) designed to maintain a predetermined voltage level. ULTC is controlled by LDC (Line Drop Compensation) method compensating line voltage drop for a varying load, and the sending voltage of ULTC calls for LDC parameters. The consequence is that the feasible LDC parameters considering variation of load and DG output are necessary. In this paper, we design each LDC parameters determining the sending voltage that can satisfy voltage level, decrease ULTC tap movement numbers, or increase DG introduction. Moreover, the maximum installable DG capacity based on each LDC parameters is estimated.

분산전원이 연계된 배전계통에서 ULTC와 분산전원의 전압제어 (Voltage Control of ULTC and Distributed Generations in Distribution System)

  • 전재근;원동준;김태현
    • 전기학회논문지
    • /
    • 제60권12호
    • /
    • pp.2206-2214
    • /
    • 2011
  • LDC(Line Drop Compensation) is widely used in controlling ULTC(Under Load Tap Changer) output voltage at distribution substation. However, LDC may experience some difficulties in voltage control due to renewable energy resources and distributed generations. Therefore, more advanced voltage control algorithm is necessary to deal with these problems. In this paper, a modified voltage control algorithm for ULTC and DG is suggested. ULTC is operated with the voltages measured at various points in distribution system and prevents overvoltage and undervoltage in the distribution feeders. Reactive power controller in DG compensates the voltage drop in each distribution feeders. By these algorithms, the voltage unbalance between feeders and voltage limit violation will be reduced and the voltage profile in each feeder will become more flat.

ULTC 와 SVR 이 설치된 배전계통에서 LDC Parameters 을 고려한 최대 DG 용량 산정 (The Installable Maximum DG Capacity Considering LDC Parameters of ULTC and SVR in Distribution Systems)

  • 김미영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.27-28
    • /
    • 2008
  • For stable and sustainable energy supply, distributed generator (DG) has become an essential and indispensable element from environmental and energy security perspectives. However, installation of DG in distribution systems may cause negative affects on feeders because power outputs of DG could be changed irregularly. One of major negative affects is variation in voltage profile. In general, voltage regulation devices such as under load tap changer (ULTC) at distribution substation and step voltage regulator (SVR) along feeder in distribution system are used to maintain customers' receiving voltage within a predetermined range. These regulators are controlled by line drop compensation (LDC) method which calls for two parameters; the equivalent impedance and the load center voltage. Therefore, consideration of DG outputs in the LDC parameter design procedure may give large impact on the installable DG capacity. This paper proposes a method that estimates maximum Installable DG capacity considering LDC parameters of ULTC and SVR. The proposed algorithm is tested with model network.

  • PDF

배전계통에 있어서 선로전압조정장치의 LDC방식에 의한 태양광전원의 수용성 향상 평가알고리즘 (Evaluation algorithm for Hosting Capacity of PV System using LDC Method of Step Voltage Regulator in Distribution Systems)

  • 이세연;이후동;태동현;노대석
    • 한국산학기술학회논문지
    • /
    • 제21권7호
    • /
    • pp.20-28
    • /
    • 2020
  • 최근, 정부의 재생에너지 3020 정책에 따라 태양광전원 등의 신재생에너지전원을 확대하는 보급 사업이 적극적으로 시행되고 있다. 하지만, 대용량의 태양광전원이 배전계통에 연계되는 경우, 수용가전압이 규정전압 범위를 벗어나게 되는 현상이 발생될 수 있어, 태양광전원의 수용성이 저하되어 보급이 지연될 가능성이 있다. 따라서, 본 논문에서는 대용량의 태양광전원이 배전계통에 연계될 경우, 태양광전원의 수용성을 향상시키기 위하여, 선로전압조정장치(step voltage regulator, SVR)의 LDC(line drop compensation, LDC)방식에 의한 태양광전원의 수용성 향상 평가알고리즘을 제시한다. 또한, 배전계통 상용해석 프로그램인 PSCAD/EMTDC를 이용하여, LDC방식의 SVR과 대용량의 태양광 전원 등으로 구성된 복합 배전계통의 모델링을 제시한다. 이를 바탕으로, SVR의 운용방식에 따른 태양광전원의 수용성을 비교·분석한 결과, LDC방식으로 운용하는 경우에는 태양광전원이 6.5[MW]까지 연계되어도 수용가전압이 규정전압 범위 이내로 유지되어, 본 논문에서 제안한 LDC 방식에 의한 태양광전원의 수용성 향상 평가알고리즘의 유용성을 확인하였다.

배전계통에서 분산전원을 증가시키는 새로운 전압조정방법에 관한 연구 (A Study for Novel Voltage Regulation Increasing DG Introduction in Distribution Systems)

  • 손준호;김미영;노대석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.450_451
    • /
    • 2009
  • 최근 부하증가에 대한 안정적 전력공급과 환경문제 해결은 전 세계적 이슈로 등장되고 있으며, 그 해결책으로써 분산형전원(Distributed generation, DG)에 대한 관심이 높아지고 있다. DG는 경제적 효율적 이유로 기존 전력계통과 연계해 운전되는데, 태양광이나 풍력과 같은 재생에너지를 이용한 DG의 불확실하며 빈번한 출력변동은 배전계통의 전압조정을 어렵게 만든다. 배전계통의 전압조정을 위해 배전용변전소의 부하시 탭 변환기(Under Load Tap Changer, ULTC)가 이용되고 있다. ULTC는 부하변동에 따른 배전선로상 전압강하를 보상하는 선로 전압강하보상법(Line Drop Compensation, LDC)에 의해 조정된다. LDC 전압조정법에서, 측정된 뱅크전류와 미리 설정된 LDC 정정치(LDC parameters, 부하중심점 전압과 등가 임피던스)를 이용해 ULTC의 송출전압을 결정한다. LDC 정정치 설계시, 기존에는 ULTC 탭 동작횟수를 줄이는 것이 주요 목표였고, 이 목표는 DG 도입을 제한하는 큰 원인이 되고 있다. 그러므로 본 논문에서는 DG 도입을 증가시키는 새로운 ULTC 전압조정법을 제시하고 모델 배전계통 시뮬레이션을 통해 그 유효성을 확인한다.

  • PDF

분산형전원이 연계된 배전계통의 전압조정에 관한 연구 (Voltage Regulation Method at the Power Distribution System interconnected with DSG System)

  • 최준호;추동욱;김재철;황치우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.250-252
    • /
    • 1997
  • This paper deals with voltage regulation at the power Distribution system interconnected with DSG. Modern distribution substation adopt LDC method as the voltage regulation method to deliver suitable voltages to many customers. However, the operations of DSG interconnected with distribution system, the customers' voltage violate the permissible voltage limits. Therefore, to deliver suitable voltage to many customers at the distribution substation, an advanced voltage regulation method is required. In this paper, the on line realtime MLDC (Multiple Line Drop compensation) method, considered daedband and hysterical tap changing of the ULTC, is proposed. The result from a simulation study shows that the proposed method can be practical applications for the voltage regulation at the distribution system interconnected with DSG and unbalanced load pattern among feeders.

  • PDF

The Advanced Voltage Regulation Method for ULTC in Distribution Systems with DG

  • Kim, Mi-Young;Song, Yong-Un;Kim, Kyung-Hwa
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권4호
    • /
    • pp.737-743
    • /
    • 2013
  • The small-scaled onsite generators such as photovoltaic power, wind power, biomass and fuel cell belong to decarbonization techniques. In general, these generators tend to be connected to utility systems, and they are called distributed generations (DGs) compared with conventional centralized power plants. However, DGs may impact on stabilization of utility systems, which gets utility into trouble. In order to reduce utility's burdens (e.g., investment for facilities reinforcement) and accelerate DG introduction, the advanced operation algorithms under the existing utility systems are urgently needed. This paper presents the advanced voltage regulation method in power systems since the sending voltage of voltage regulators has been played a decisive role restricting maximum installable DG capacity (MaxC_DG). For the proposed voltage regulation method, the difference from existing voltage regulation method is explained and the detailed concept is introduced in this paper. MaxC_DG estimation through case studies based on Korean model network verifies the superiority of the proposed method.

The Coordinate Control Method of LTC Transformer and Capacitor Banks at Distribution Substation

  • Choi, Joon-Ho;Ahn, Seon-Ju;Nam, Hae-Kon;Kim, Jae-Chul;Moon, Seung-Il;Jung, Won-Wook;Song, Il-Keun
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권3호
    • /
    • pp.320-329
    • /
    • 2012
  • The Load Tap Changing (LTC) transformer and Shunt Capacitor (SC) bank are major devices for voltage and reactive power control in a distribution substation. Thus, the coordination operation of a LTC transformer and a SC bank is required to achieve better voltage and reactive power compensation at a distribution substation in the same time. This paper proposes coordinate control method of LTC transformer and SC bank to achieve better voltage and reactive power compensation and operation times of these two devices in the same time. The mathematical formulations of the proposed coordinate control method are introduced. Sample case studies are shown to verify the effectiveness of the proposed coordinate control method.

PSCAD/EMTDC를 이용한 배전계통의 선로전압조정장치와 전지전력저장장치의 모델링에 관한 연구 (A Study on the Modeling of Step Voltage Regulator and Energy Storage System in Distribution System Using the PSCAD/EMTDC)

  • 김병기;김기영;이주광;최성식;노대석
    • 한국산학기술학회논문지
    • /
    • 제16권2호
    • /
    • pp.1355-1363
    • /
    • 2015
  • 태양광전원이 연계된 배전계통에서 발생되는 과전압문제를 해소하기 위하여, 계통에서 발생하는 전압변동에 대응하여 전압을 일정하게 유지시킬 수 있는 선로 전압 조정장치(Step Voltage Regulator)의 도입이 제안되고 있다. 일반적으로 SVR은 전압조정 방법에 의하여 Tap위치를 결정한 후, 일정시간이 지나면 Tap이 동작하도록 운용된다. 하지만 지연시간(30sec) 이후에 Tap을 동작시키는 SVR의 특성에 의하여, 이 시간동안 수용가전압은 규정치를 벗어날 가능성을 가지고 있다. 따라서 본 논문에서는 배전계통의 상용소프트웨어인 PSCAD/EMTDC를 이용하여 LDC방법에 의한 SVR의 전압조정 모델링과, 양방향으로 유무효전력을 제어할 수 있는 전지전력저장장치(Battery Energy Storage System)의 모델링을 제안하였다. 또한 SVR의 문제점을 보완하기 위하여, BESS와의 협조방안에 대한 모델링을 제시하였다. 상기에서 제안한 모델링을 바탕으로 수용가의 전압특성을 분석한 결과, SVR과 BESS에 의하여 안정적으로 전압이 유지됨을 확인하여, 본 연구에서 제시한 모델링의 유효성을 입증하였다.

분산전원이 연계된 고압배전선로에 있어서 선로전압 조정장치의 최적운용 평가시스템 개발 (Optimal Operation System of Step Voltage Regulator in Primary Feeders with Distributed Generations)

  • 손준호;허상운;노대석;김의환
    • 한국산학기술학회논문지
    • /
    • 제12권6호
    • /
    • pp.2698-2706
    • /
    • 2011
  • 본 논문에서는 기존의 고압배전선로에 설치되어 운용되고 있는 선로전압조정장치(Step Voltage Regulator, 이하 SVR)의 최적 전압조정 알고리즘을 제시하고 이를 이용하여 수용가전압을 평가할 수 있는 최적 평가시스템을 제시한다. 현재 SVR은 일정전압 송출방식을 사용하고 있지만, 대규모의 태양광, 풍력 등의 분산전원이 배전계통에 도입되는 경우, 전압품질[과전압/저전압] 문제점을 발생시킬 수 있다. 따라서 본 논문에서는 선로전압조정장치의 LDC운용에 필수적인 정정치를 계산하기 위하여, 비선형 최적화수법인 선형회귀법을 사용하여 선로전압조정장치의 최적 운용 알고리즘을 제시하였고, 제안한 알고리즘을 바탕으로 평가시스템을 제작하여, 분산전원의 타입과 연계용량에 따라 다양한 시뮬레이션을 수행하여 제안한 알고리즘의 유효성을 확인하였다.