• Title/Summary/Keyword: Line code

Search Result 687, Processing Time 0.023 seconds

Coincidence summing correction for a voluminous 152Eu source

  • Yoon, Eun Taek;Kang, Min Young;Kim, In Jung;Sun, Gwang Min;Choi, Hee-Dong
    • Nuclear Engineering and Technology
    • /
    • v.52 no.6
    • /
    • pp.1266-1270
    • /
    • 2020
  • A code is developed to correct for the coincidence summing effect in detecting a voluminous gamma source, and this code is applied to a152Eu standard source as a test case. The source is 1000 mL of liquid in a cylindrical shape. To calculate the coincidence summing effect, the cylindrical source is considered as 10(radial) × 8(height) sectional sources. For each sectional source, the peak efficiency and total efficiency are obtained by Monte Carlo simulation at each energy for 10 energies between 50 keV and 2000 keV. The efficiencies of each sector are then expressed as polynomials of gamma energy. To calculate the correction coefficients for the coincidence summing effect, the KORSUM code is used after modification. The magnitudes of correction are 4%-17% for the standard 152Eu source measured in this study. The relative deviation of 4.7% before the coincidence correction is reduced to 0.8% after the correction is applied to the efficiency based on the measured gamma line. Hence, this study has shown that a new method has been developed that is applicable for correcting the coincidence effect in a voluminous source, and the method is applied to the measured data of a standard 152Eu cylinder source.

A Study on the Recognition of Defected Fingerprint Using Chain Code (체인 코드를 이용한 훼손된 지문의 인식에 관한 연구)

  • 조민환
    • Journal of the Korea Society of Computer and Information
    • /
    • v.8 no.4
    • /
    • pp.63-68
    • /
    • 2003
  • Almost the system are usually taken by means of shapes and positions of ridge's end-points and bifurcation in the fingerprint recognition. but we studied about recognition of polluted fingerprint by chain code ridges. the results and sequence of processing are summarized as follows. (1)Capture several kinds of polluted fingerprint image. (2)Preprocessing(median filtering for removing noises, local and global histogram equalization, dilation and erosion, thinning and remove pseudo image), (3)Rebuild ridge line after Least Square Processing, (4)Compute distribution of chain code vector, (5)The results are almost same values of each vector of preprocessed fingerprint images. From the results, we can surmised more successful fingerprints recognition system in combination with other system by singular points

  • PDF

A Combined Pseudo-random Noise Signal Based Advanced Region Correlation Scheme for BOC(pn,n) Modulated GNSS Signals in Repeat-back Jamming Environment (재방송 재밍 환경에서 BOC(pn,n) GNSS 변조된 신호를 위한 CP-ARC 기법)

  • Yoo, Seungsoo;Yeom, Dong-Jin;Jee, Gyu-In;Kim, Sun Yong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.11
    • /
    • pp.977-983
    • /
    • 2016
  • This paper proposes a novel code-tracking scheme to track the fine code synchronization for BOC (pn,n)-modulated global navigation satellite system signals in a repeat-back jamming environment. The correlation function of BOC (pn,n)-modulated signals has several peaks. The correlation function in the advanced offset region remains almost unchanged due to the repeat-back signals being received later than a line-of-sight signal in the same multipath signal receiving case. Additionally, the combined pseudo-random noise signal can be treated as repeat-back jamming signals, like multipath signals. In this paper, we propose a novel code-tracking scheme utilizing the advantages of using a combined pseudo-random noise signal in the advanced offset region and verify its performance through simulation.

IRRADIATION TEST OF MOX FUEL IN THE HALDEN REACTOR AND THE ANALYSIS OF MEASURED DATA WITH THE FUEL PERFORMANCE CODE COSMOS

  • WIESENACK WOLFGANG;LEE BYUNG-HO;SOHN DONG-SEONG
    • Nuclear Engineering and Technology
    • /
    • v.37 no.4
    • /
    • pp.317-326
    • /
    • 2005
  • The burning-out of excess plutonium from the reprocessing of spent nuclear fuel and from the dismantlement of nuclear weapons is recently emphasized due to the difficulties in securing the final repository for the spent fuel and the necessity to consume the ex-weapons plutonium. An irradiation test in the Halden reactor was launched by the OECD Halden Reactor Project (HRP) to investigate the in-pile behavior of plutonium-embedded fuel as a form of mixed oxide (MOX) and of inert matrix fuel (IMF). The first cycle of irradiation was successfully accomplished with good integrity of test fuel rods and without any undesirable fault of instrumentations. The test results revealed that the MOX fuel is more stable under irradiation environments than IMF. In addition, MOX fuel shows lower thermal resistance due to its better thermal conductivity than IMF. The on-line measured in-pile performance data of attrition milled MOX fuel are used in the analysis of the in-pile performance of the fuel with the fuel performance code, COSMOS. The COSMOS code has been developed for the analysis of MOX fuel as well as $UO_2$ fuel up to high burnup and showed good capability to analyze the in-reactor behavior of MOX fuel even with different instrumentation.

Analysis of Characteristics of Spent Fuels on Long-Term Dry Storage Condition

  • Yoon, Suji;Park, Kwangheon;Yun, Hyungju
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.19 no.2
    • /
    • pp.205-214
    • /
    • 2021
  • Currently, the interim storage pools of spent fuels in South Korea are expected to become saturated from 2024. It is required to prepare an operation plan of a domestic dry storage facility during a long-term period, with the researches on safety evaluation methods. This study modified the FRAPCON code to predict the spent fuel integrity evaluation such as the axial cladding temperature, the hoop stress and hydrogen distribution in dry storage. The cladding temperature in dry storage was calculated using the COBRA-SFS code with the burnup information which was calculated using the FRAPCON code. The hoop stress was calculated using the ideal gas equation with spent fuel information such as rod internal pressure. Numerical analysis method was used to calculate the degree of hydrogen diffusion according to the hydrogen concentration and temperature distribution during a dry storage period. Before 50 years of dry storage, the cladding temperature and hoop stress decreased rapidly. However, after 50 years, they decreased gradually and the cladding temperature was below 400 K. The initial temperature distribution and hydrogen concentration showed a parabolic line, but hydrogen was transferred by the hydrogen concentration and temperature gradient over time.

RCV bogie frame structure safety evaluation according to UIC Code (국제 철도 연맹 규정(UIC Code)에 따른 RCV 대차 프레임 구조 안전성 평가)

  • Sang Cheol Rho;Ji Hyeong Park;Shin You Kang
    • Journal of Industrial Technology
    • /
    • v.43 no.1
    • /
    • pp.7-13
    • /
    • 2023
  • Nowadays, traffic congestion is emerging as a major problem due to the rapid population growth and the increase in automobiles. The train is a convenient means of transportation that can efficiently solve these problems. Trains have been developed in line with human aspirations for a long time, but research on safety is still insufficient. This study aims to check safety by conducting static tests and fatigue tests on bogie frames, and to help develop bogie frames in the future. For the static test, a strain gauge was attached to the point where the local stress concentration was expected beforehand, and the result value was derived, compared with existing theories, and expressed as a Goodman diagram. In the fatigue test, a total of 10 million loads were applied over three stages, and no cracks appeared in the non-destructive test conducted after each stage. Both tests were conducted according to the strict test method of the bogie frame presented by the UIC Code. It satisfied both fatigue life and strength evaluation criteria and was judged to be a bogie frame usable for safe train production.

LYα LINE FORMATION IN HUBBLE-TYPE SPHERICAL OUTFLOWS IN STARBURST GALAXIES

  • AHN SANG-HYEON;LEE HEE-WON
    • Journal of The Korean Astronomical Society
    • /
    • v.35 no.4
    • /
    • pp.175-185
    • /
    • 2002
  • Almost half of primeval galaxies show P-Cygni type profiles in the Ly$\alpha$ emission line. The main underlying mechanism for the profile formation in these systems is thought to be the frequency re-distribution of the line photons in expanding scattering media surrounding the emission source. A Monte Carlo code is developed to investigate the Ly$\alpha$ line transfer in an optically thick and moving medium with a careful consideration of the scattering in the damping wings. Typical column densities and expansion velocities of neutral hydrogen investigated in this study are $N_{H1}{\~}10^{17-20}\;cm^{-2}$ and ${\Delta}V{\~} 100 km\;s^{-1}$. We investigate the dependence of the emergent profiles on the kinematics and on the column density. Our numerical results are applied to show that the damped Ly$\alpha$ absorbers may possess an expanding H I supershell with bulk flow of ${\~}200 km\;s^{-l}$ and H I column density $N_{H1}{\~}10^{19}\;cm^{-2}$. We briefly discuss the observational implications.

A study of the light control system for the MH lamp using the power line communication (전력선 통신을 이용한 MH 램프의 조광제어 시스템에 관한 연구)

  • Jung, Kwang-Hyun;Park, Chong-Yeun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.45 no.2
    • /
    • pp.83-91
    • /
    • 2008
  • To design the light control system using the PLC(Power Line Communication) with the ballasts of MH(Metal Halide) lamps, we analyzed the noise effect on the power line by the electronic ballast. For the power line characteristics are changed by the loads, the ballast have to be designed to be suitable to the PLC. Therefore, this paper proposed the optimal ballast and designed two kinds of PLM(Power Line Modem) which one is ASK type and the other is FSK type. Two type of PLM have used the manchester codes or DS/SS code. Experimental results have shown that the FSK type modem by the DS/SS coding technique have the best characteristics.