• 제목/요약/키워드: Line arrester

검색결과 100건 처리시간 0.039초

혼합 배전계통에서 피뢰기적용과 접지시스템 변경을 고려한 서지 해석에 관한 연구 (A Study on the Surge Analysis considering Surge Arrester and Grounding System in the Combined Distribution System)

  • 윤창섭;이종범;김병숙
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.204-205
    • /
    • 2006
  • This paper describes the protective ability of lightning arrestor in combined distribution system with power cable. To evaluate the protective ability, change of arrestor and grounding location are considered. On the other hand, arrestor developed by Cooper Power Systems for underground power cable system, is considered to evaluate surge protective ability as in underground system, when arrestor occurs failure has overhead line. The result shows that lightning arrestor in combined distribution system with power cable protect effectively when failure at arrestor in overhead line. On the other hand, arrestor developed by Cooper Power Systems for underground power cable system, is considered to evaluate surge protective ability in underground distribution system, when arrestor of overhead line has failure. The result shows that lightning arrestor installed in underground cable can effectively protected cables from surge when arrestor of overhead line has failure. And also even though grounding locations are decreased, it is revealed that protective ability is nearly similar.

  • PDF

전기철도 전원계통에서의 화재사고 사례 분석 (Analysis of Fire Accident on Power Line for DC Electric Traction Vehicles)

  • 송재용;조영진;남정우;김진표;박남규
    • 한국안전학회지
    • /
    • 제25권2호
    • /
    • pp.18-23
    • /
    • 2010
  • This paper describes a cause of fire accidents on power system fire DC electric traction vehicles. We investigated fire scene of power line for DC electric traction vehicles. From analysis results, the cause of fire on power line turned out line to ground fault between a feeder of electric power services(pantagraph) and DC electric traction vehicle roof. Fire accident of DC electric traction vehicles be assumed that electric sparks had been produced between the pantagraph and the power line conductor by repetitively making contact and separation, maybe if some material like branches get in between connecting rod it makes progress line to ground fault. ZnO arresters are widely used to protect DC electric traction vehicles against overvoltages caused by lightning or switching surges. However, the arresters are deteriorated by commercial overvoltages and/or lightning one. The deteriorated arresters could lead power failures, such as line to ground fault by a thermal runaway resulting from the increases in leakage current even in a nominal power system voltage. Finally, the power failures would be causative of the fire accident.

국내 지중배전시스템의 서어지 보호방안 (Surge Protection Method of the Underground Distribution System in Korea)

  • 이재봉;정연하;박철배
    • 조명전기설비학회논문지
    • /
    • 제22권10호
    • /
    • pp.84-88
    • /
    • 2008
  • 본 논문은 2007년에 게재된 "지중배전케이블의 서어지 전파특성 실증연구"를 통해 검증된 서어지 전파특성을 고려하여 피뢰기를 이용한 보호효과를 ATP-EMTP(Electro-Magnetic Transient Program)로 해석하고 국내 상황에 적합한 보호방법을 제시하고자 한다. 국내 지중배전시스템은 입상주에 설치된 피뢰기에 의해 보호되고 있지만 서어지가 케이블의 말단 개방점에서 두배 정도로 상승하여 배전설비의 절연을 위협할 수 있으므로 추가적인 보호 방법이 필요하다. 본 논문에서 추가적인 보호 방법으로 제안하는 스카우트 방법은 입상주 피뢰기 전 후단 전주에 피뢰기를 추가 설치하는 방법으로 지중배전선로에 피뢰기를 설치하기 곤란한 경우나 지중배전선로용 엘보우 피뢰기를 개발하여 적용하는 것보다 경제성에서 유리하고 설치 및 유지보수 측면에서도 효과적일 것으로 기대된다.

Wavelet 변환을 이용한 고저항 지락고장 검출 (High Impedance Fault Detection using Wavelet Transform)

  • 김현;김철환
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권12호
    • /
    • pp.1492-1497
    • /
    • 1999
  • High impedance fault(HIF) is defined as fault the general overcurrent relay can not detect or interrupt. Especially when HIF occur in residential areas, energized high voltage conductor results in fire hazard, equipment damage or personal threat. This paper proposes the model of the high impedance fault in transmission line using the ZnO arrester and resistance to be implemented within EMTP. The performance of the proposed model is tested on a typical 154[kV] korean transmission line system under various fault conditions. Wavelet transform is efficient and useful for the detection of high impedance fault in power system, because it uses variable windows according to frequency. In this paper, HIF detection method using wavelet transform can distinguish HIF form similar fault like arcfurance load, capacitor bank switching and line switching.

  • PDF

가스절연송전선로의 서지특성 분석에 관한 연구 (A Study on Analysis of Surge Characteristics on Gas Insulated Transmission Lines)

  • 정채균;박흥석;강지원;장태인;윤종건;김양상;석광현;김형호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.371_372
    • /
    • 2009
  • This paper describes surge characteristics on 345kV combined transmission system mixed overhead line and GIL(Gas Insulated Transmission Line). Then, it is compared with the results of the system mixed overhead line and XLPE power cables. Finally the lightning overvoltages are also discussed according to surge arrester installation in two kinds of combined transmission systems when the lighting strikes on the phase conductor.

  • PDF

직격뢰 침입시 배전계통에서 선로 및 기기의 절연설계 (Insulation Design of Line and Equipment in Distribution Systems in Case of the Stroke of Direct Lightning Surge)

  • 정채균;김상국;이종범;하동혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.449-451
    • /
    • 2003
  • This paper examines the insulation coordination scheme of line and equipment in distribution system when the direct lightning surge strikes. The BIL that is applied in distribution system is not properly considered the performance and operation of arresters. Because of that, the high BIL is being used at partial system. This paper variously analyse the lightning overvoltage of line and equipment with earth of overhead grounding wire and installation types of arrester. Form these result, authors examine the rationality of BIL.

  • PDF

배전선로의 유도뢰 해석 (Analysis on Overvoltage induced on Power Distribution line by Lightning surge)

  • 김헌준;최상열;정호성;신명철;박남옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.279-281
    • /
    • 1998
  • This paper present overvoltage induced on distribution power line by lightning surge. It is important problem that overvoltage threatens credit and security of the power system. In this paper induced overvoltage was calculated. From the line being modeled in really actual practice. Also, the proper suppressing effects of a surge arrester against lightning induced voltages were suggested.

  • PDF

전차 선로용 DC 피뢰기 설계 기술 (The Design Technology of DC Arrester for Track Line)

  • 한세원;조한구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.259-261
    • /
    • 2001
  • 전차 선로용으로 적용되는 직류 피뢰기의 설계 기술을 소개하였다. 현재 국내에 사용되는 전차 선로 서지 보호용 직류 피뢰기는 전량 수입에 의존하고 있다. 안전한 피뢰기를 설계하기 위해서 적용 구간의 임펄스 서지 환경을 파악하고 이에 맞는 적절한 내량의 피뢰기를 설계하는 것이 요구된다. 특히 직류 구간의 경우 과도 서지 발생의 형태가 기존 계통 환경과 다르기 때문에 피뢰기 보호범위와 정격의 설정에 주의가 요구된다.

  • PDF

혼합배전계통에서 EMTP/ATPDraw를 이용한 개폐서지 해석 (A Study and Analysis on the Switching Surge Using EMTP/ATPDraw in Combined Distribution Systems)

  • 이장근;이종범;이재봉;김병숙
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.280-282
    • /
    • 2005
  • This paper describes switching overvoltage generated during transient state in 22.9kV combined distribution systems. For analysis, distribution overhead line, underground cable and surge arrester are modeled using EMTP/ATPDraw. Simulation results show switching overvoltage according to various kind of parameter and systems such as closing angle and cable length.

  • PDF

오손등급에 따른 배전기자재의 절연특성 연구 (Insulating Characteristics of the Distribution Facilities due to Grade of Salt Contamination)

  • 권태호;김동명;김주용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1490-1491
    • /
    • 2007
  • The salt contamination on the distribution facilities, such as suspension insulator, line post insulator, lightning arrester, COS, is one of the major coastal areas because more than 90% of salt contaminated failure occurs in distribution facilities. Did to stain distribution facilities artificially according to Equivalent Salt Deposit Density(ESDD) grade. The electrical test were performed on the non-polluted and polluted facilities(ESDD B, C, D grade).

  • PDF