• Title/Summary/Keyword: Line Trace

Search Result 194, Processing Time 0.022 seconds

Study about Power Transformer and Lines Tracing Method based on Power Line Communication Technology (전력선 통신 기술을 활용한 변압기 및 전력선로 추적 방법 개발에 관한 연구)

  • Byun, Hee-Jung;Choi, Sang-jun;Shon, Sugoog
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.505-508
    • /
    • 2016
  • In city, tracing of power transmission lines is difficult due to compound installation of overhead and underground lines, transposition, bad view caused by trees or big buildings. It is hard problem for electrical technician on site to trace power transformers or power lines to serve customers in 3 phase -4 wires power distribution systems. It is necessary that the correct and fast tracing method is required for load balancing among distribution lines. Old technology use to trace lines with high power impulse injection. Our proposed method uses to trace lines with very small power high frequency signal injection. Simulation models for 3-phase power transformers, 3-phase wire lines, and customer loads are described to investigate the transmission characteristics of high frequency power line carrier. Distribution lines have only a limited ability to carry higher frequencies. Typically power transformers in the distribution system prevent propagating the higher frequency carrier signal. The proposed method uses the limited propagation ability to identify the power transformer to serve customers. The system consists of a transmitter and a receiver with power-line communication module. Some experiments are conducted to verify the theoretical concepts in a big commercial building. Also some simulations are done to help and understand the concepts by using MATLAB Simulink simulator.

  • PDF

Optimization for the Solid-Phase Extraction of Trace Clobazam from Biological Samples (생체시료로부터 미량 크로바잠의 고상추출을 위한 최적화)

  • Kim, Kyoung-Rae;Kim, Jeong-Ho;Kim, Hyub;Yoon, Hye-Ran
    • YAKHAK HOEJI
    • /
    • v.39 no.4
    • /
    • pp.395-400
    • /
    • 1995
  • The sorption and desorption properties of four adsorbents were evaluated for the trace enrichment of clobazam from biological samples. Graphitized carbon black(GCB) gaved the highest dynamic adsorption coefficient. Among the six organic solvents examined, acetone gave the highest desorption coefficient for the clobazam adsorbed on GCB. Using the GCB column, the optimum elution volume of the eluting solvent was evaluated from the on-line monitored breakthrough curve for clobazam. When GCB as the solid adsorbent and acetone as the eluting solvent were used for the solidphase extraction of clobazam from serum, the recoveries were higher than 83% with good reproducibility in the concentration range of 20-50 $\mu\textrm{g}$/ml.

  • PDF

Method of Ventilation by Gas Chromatography and the Effects of the Type of Blouse (G.C를 이용한 Ventilation 측정방법과 Ventilation에서의 블라우스형태변화의 영향)

  • Park Woo Mee;Choi Chul Ho
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.16 no.1 s.41
    • /
    • pp.53-63
    • /
    • 1992
  • The purpose of this study is to investigate the method of trace gas technique by G.C and the effects of the type of blouse on ventilation. The experimental system employed a trace gas technique in which ventilation was monitored to determine oxigen exchange rate. The experimental variables were tested with three types of blouse depending on the sizes of neckline, armhole and waist line. Exercise conditions include standing and walking position. The results and discussion forcused on the construct validity of the apparatus/testing protocol. the effect of experimental variables on ventilation was also discussed.

  • PDF

Optimal Laser Line Detection of Structured Light using Dynamic Programming (동적계획법을 사용한 구조화 조명의 최적 레이저 라인 검출)

  • Ko, Su-Hong;Gim, Seong-Chan;Lee, Wang-Hee;Kim, Jong-Man;Kim, Hyong-Suk
    • Proceedings of the KIEE Conference
    • /
    • 2006.10c
    • /
    • pp.300-302
    • /
    • 2006
  • The structured lighting technique is a very accurate depth measurement method. One problem in this technique is that the laser light is invisible very often partly or as a whole caused from occlusion, light absorbtion, and reflection on the surface. If there is no laser light detected on a row of the image frame, the depth could not be computed at the point on the row. In this paper, a Dynamic Programing-based efficient laser line tracking algorithm is proposed to find the most likely line of the laser light utilizing all the possible information of the laser light trace. The performance of the algorithm is shown.

  • PDF

Jansen Mechanism을 기반으로 한 보행로봇의 최적화와 Line tracer

  • Do, Seung-Hun;Choe, Ju-Yeong;Kim, Min-Su;Park, Hyeon-Su;Kim, Dong-Hwi;Lee, Chun-Yeol
    • Proceeding of EDISON Challenge
    • /
    • 2017.03a
    • /
    • pp.506-510
    • /
    • 2017
  • Based on the Jansen mechanism theory, a walking robot is developed, which is able to trace a line. In order to find the optimized legs, GL(Ground Length), GAC(Ground Angle Coefficient) and Grashof criteria are utilized in m.sketch program as well as EdisonDesign program. Many types of design are applied to sensors and controls, and the functionality is checked. Finally, a prototype line tracer robot is manufactured using aduino parts and smart boards. The prototype robot is test run to check the validity of the design, and modifications are applied to improve the performance according to each test result until the best design is achieved.

  • PDF

Low-dose of organic trace minerals reduced fecal mineral excretion without compromising performance of laying hens

  • Qiu, Jialing;Lu, Xintao;Ma, Lianxiang;Hou, Chuanchuan;He, Junna;Liu, Bing;Yu, Dongyou;Lin, Gang;Xu, Jiming
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.33 no.4
    • /
    • pp.588-596
    • /
    • 2020
  • Objective: The objective of this study was to investigate the effects of low doses of organic trace minerals (iron, copper, manganese, and zinc) on productive performance, egg quality, yolk and tissue mineral retention, and fecal mineral excretion of laying hens during the late laying period. Methods: A total of 405 healthy hens (HY-Line White, 50-week-old) were randomly divided into 3 treatments, with 9 replicates per treatment and 15 birds per replicate. The dietary treatments included feeding a basal diet + inorganic trace minerals at commercial levels (CON), a basal diet + inorganic trace minerals at 1/3 commercial levels (ITM), and a basal diet + proteinated trace minerals at 1/3 commercial levels (TRT). The trial lasted for 56 days. Results: Compared to CON, ITM decreased (p<0.05) egg production, daily egg mass, albumen height, eggshell strength, yolk Fe concentration, serum alkaline phosphatase activity and total protein, and increased (p<0.05) egg loss and feed to egg ratio. Whereas with productive performance, egg quality, yolk mineral retention, and serum indices there were no differences (p>0.05) between CON and TRT. The concentrations of Fe and Mn in the tissue and tibia were changed notably in ITM relative to CON and TRT. Both ITM and TRT reduced (p<0.05) fecal mineral excretion compared to CON. Conclusion: These results indicate that dietary supplementation of low-dose organic trace minerals reduced fecal mineral excretion without negatively impacting hen performance and egg quality.

A Development of Gas Line Safety Management System by GIS (GIS를 이용한 가스관의 안전 관리시스템 개발)

  • 최병길;정영동;김영곤
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.18 no.1
    • /
    • pp.11-17
    • /
    • 2000
  • GIS is the system that has ability of integrating, managing, and analyzing the voluminous graphic and text data, which is adequate system to manage complex network of the underground utilities of urban area. A development of gas line safety management system is accomplished to construct a database of gas line network and topographic data, create safety managing model, and estimate openly its safety by GIS. This system is designed to evaluate easily the damaged facilities in case of gas line explosion by the establishment of the geographic output system. It is designed to trace and present efficiently closed valves and interrupted facilities of gas when gas line breakage occurs, and offer the information by which one can take quickly emergency. And also, it is constructed to prevent from accident occurring under construction work by showing underground utilities and states of work.

  • PDF

Fundamental Studies on the Development of On-line Monitoring of Trace Mercury in Drinking Water (음용수 중 수은 연속자동측정시스템의 개발에 관한 연구)

  • Chang, Soo-Hyun;Kim, Hyo-Jin;Kim, Sun-Tae;Kim, Young-Man
    • Analytical Science and Technology
    • /
    • v.12 no.4
    • /
    • pp.299-305
    • /
    • 1999
  • The electrolyte cathode atomic glow discharge (ELCAD) is a new plasma source for direct determination of trace heavy metals in drinking and waste water. ELCAD has been successfully developed for on-line monitoring of heavy metals, however, shows difficulty to measure mercury. In this study, ELCAD has been modified to apply the atomic absorption spectrometry (AAS) for the direct determination of trace elements of mercury in flowing water.The fundamental characteristics of this new types of plasma source have been investigated and found that the pH of the solution, discharge voltage, and current are most important factors.The absorbance of 1.0 ppm Hg standard solution increases as pH of the solution increases from pH 1.0 to 3.0.However, % RSD of the absorbance also increases as the pH of solution increasesdue to plasma unstability.The detection limits of the standard solution of pH 1.5 and pH 3.0 are about 40 ppb and 10 ppb level, respectively.

  • PDF

The Design and Implementation of On-Line Performance Monitor for JaNeC (JaNeC을 위한 온라인 성능감시기의 설계 및 구현)

  • Kim, Myung-Ho;Kim, Nam-Hoon;Choi, Jae-young
    • The KIPS Transactions:PartA
    • /
    • v.9A no.4
    • /
    • pp.563-572
    • /
    • 2002
  • A performance monitor is indispensable to trace and evaluate performance of a program under distributed processing environment. A performance monitor il classified as off-line and on-line according to its output method. An off-line performance monitor analyzes its performance after a program terminates, and an on-line performance monitor analyzes its one while a program runs. Therefore, the on-line function is essential to analyzing and debugging the program fast. JaNeC, distributed processing environment that is implemented in Java, contains an off-line performance monitor for this. However, this performance monitor may not analyze the program running on JaNeC efficiently. Consequently, this paper explains that an on-line performance monitor is designed and implemented for fast analysis and debugging of the program running on JaNeC. This on-line performance monitor is designed to minimize effects on a program to analyze, and provides various forms of graphic output, to analyze the program effectively. In addition, even after a program terminates, it provides interface with the off-line performance monitor, to analyze again.

Design Optimization of Differential FPCB Transmission Line for Flat Panel Display Applications (평판디스플레이 응용을 위한 차동 FPCB 전송선 설계 최적화)

  • Ryu, Jee-Youl;Noh, Seok-Ho;Lee, Hyung-Joo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.5
    • /
    • pp.879-886
    • /
    • 2008
  • This paper addresses the analysis and the design optimization of differential interconnects for Low-Voltage Differential Signaling (LVDS) applications. Thanks to the differential transmission and the low voltage swing, LVDS offers high data rates and improved noise immunity with significantly reduced power consumption in data communications, high-resolution display, and flat panel display. We present an improved model and new equations to reduce impedance mismatch and signal degradation in cascaded interconnects using optimization of interconnect design parameters such as trace width, trace height and trace space in differential flexible printed circuit board (FPCB) transmission lines. We have carried out frequency-domain full-wave electromagnetic simulations, time-domain transient simulations, and S-parameter simulations to evaluate the high-frequency characteristics of the differential FPCB interconnects. The 10% change in trace width produced change of approximately 6% and 5.6% in differential impedance for trace thickness of $17.5{\mu}m$ and $35{\mu}m$, respectively. The change in the trace space showed a little change. We believe that the proposed approach is very helpful to optimize high-speed differential FPCB interconnects for LVDS applications.