• Title/Summary/Keyword: Line Switching

Search Result 610, Processing Time 0.028 seconds

A study on the servo system controller design of variable structure systems with new switching surface (새로운 스위칭 평면을 가지는 가변구조 서보 제어기 설계에 관한 연구)

  • 문용기;이정훈;이대식;윤명중
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10a
    • /
    • pp.308-312
    • /
    • 1990
  • In this paper, we propose a simple method to control the servo system with sliding mode in the parameter variation and disturbances. We show the comparison between the conventional sliding line and the new sliding line and the proposed sliding mode control. The performance of the fast response and no overshoot by using the proposed sliding line is obtained.

  • PDF

Estimation Technique of Power Transmission Line Parameter by Phasor Measurement Units (송전선로 파라메터 정밀 예측을 위한 페이저 측정기의 응용)

  • Cho, Ki-Seon;Park, Jong-Bae;Shin, Joong-Rin
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.193-195
    • /
    • 2003
  • This paper presents an approach to estimate the power transmission line parameter by phasor measurement units(PMUs), which are synchronized to 1 pps signal of GPS. Existing approaches to estimate power transmission line parameter, are mainly off-line ones, based on faults or switching events on other neighboring lines. In this paper, to obtain static and dynamic properties of power transmission line parameter in service, the prototype of pmu-based Transmission Line Parameter Monitoring System (TLPMS) is proposed. Also, an technique to estimate parameters of transmission line described as 2-port network model and the soundness of estimated parameters are addressed.

  • PDF

Dual Utility AC Line Voltage Operated Voltage Source and Soft Switching PWM DC-DC Converter with High Frequency Transformer Link for Arc Welding Equipment

  • Morimoto Keiki;Ahmed NabilA.;Lee Hyun-Woo;Nakaoka Mutsuo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.5B no.4
    • /
    • pp.366-373
    • /
    • 2005
  • This paper presents two new circuit topologies of the dc busline side active resonant snubber assisted voltage source high frequency link soft switching PWM full-bridge dc-dc power converters acceptable for either utility ac 200V-rms or ac 400V-rms input grid. These high frequency switching dc-dc converters proposed in this paper are composed of a typical voltage source-fed full-bridge PWM inverter, high frequency transformer with center tap, high frequency diode rectifier with inductor input filter and dc busline side series switches with the aid of a dc busline parallel capacitive lossless snubber. All the active switches in the full-bridge arms as well as dc busline snubber can achieve ZCS turn-on and ZVS turn-off transition commutation with the aid of a transformer leakage inductive component and consequently the total switching power losses can be effectively reduced. So that, a high switching frequency operation of IGBTs in the voltage source full bridge inverter can be actually designed more than about 20 kHz. It is confirmed that the more the switching frequency of full-bridge soft switching inverter increases, the more soft switching PWM dc-dc converter with a high frequency transformer link has remarkable advantages for its power conversion efficiency and power density implementations as compared with the conventional hard switching PWM inverter type dc-dc power converter. The effectiveness of these new dc-dc power converter topologies can be proved to be more suitable for low voltage and large current dc-dc power supply as arc welding equipment from a practical point of view.

A Study on Conducted EMI Emission Characteristics in 3-Phase PWM Converter (3상 PWM 컨버터의 전도성 EMI 특성에 관한 연구)

  • 채영민;고재석;목형수;최규하;홍순찬;백수현;이은웅
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.2 no.2
    • /
    • pp.41-48
    • /
    • 1997
  • Nowadays, EMI emission characteristics, which causes harmful effect on power distribution system and other equipments, have been studied in field of Power electronics, vigoriously. So, in this paper, the conducted EMI emission is measured and compared for 3-phase diode rectifier and PWM converter according to switching frequency variation and current control method change using LISN(Line Impedance Stabilization Network) and spectrum analyzer.

  • PDF

A study on the auto-charging circuit of the battery power units using trigger characteristics of semiconductor device (반도체 스위칭 소자의 트리거 특성을 이용한 배터리 자동 충전회로에 관한 연구)

  • 김영민;황종선;박성진;임종연;송승호
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.519-522
    • /
    • 2001
  • Recently, the battery charging technology and reducing technology of harmonics on AC input line are rising importantly according to increasing electrical facilities that it has been replaced battery with emergency power. In this study, I proposed that an auto-charging circuit of battery has low cost with simple-construction circuit, relative, harmonics reduction with diode tap-change method, high reliability of system for using characteristics of thyristor switching. In case of this circuit, convenience and reliability of maintenance of battery power units were more improved. 1 think that it is resulted in effect of prevention to shortening of battery life from over-charging and over-discharging and decrease of harmonics obstacle on AC input line.

  • PDF

Fault Detection and Classification of Hi9h Impedance Fault using Wavelet Transform (웨이브렛 변환을 이용한 고저항 지락사고 검출 및 판별)

  • Ko, Y.H.;Kim, C.H.;Kim, H.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1373-1375
    • /
    • 1999
  • High impedance fault (HIF) is defined as fault the general overcurrent relay can not detect or interrupt. Especially when HIF occur in residential areas, energized high voltage conductor results in fire hazard, equiment damage or personal threat. This paper proposes the model of HIF in transmission line using the ZnO arrester and resistance to be implemented within EMTP. Wavelet transform is efficient and useful for the detection of HIF in power system, because it uses variable windows according to frequency. HIF detection method using wavelet transform can distinguish HIF from similar phenomena like arcfurance load, capacitor bank switching and line switching.

  • PDF

A Study on the Characteristics of the Synchroneous Data Transmission by the Phase Band Limit of AC Power Wave to Avoid the Periodic Noises in the Data Communication System of Distribution Line Carrier Method (배전선 반송 데이타통신에서의 전원동기 위상대역한정 전송에 의한 주기적 노이즈신호 회피특성에 관한 연구)

  • 최순만;노창주
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.18 no.3
    • /
    • pp.78-84
    • /
    • 1994
  • The location of periodic noises in phase of AC power wave reveals to be specific according to the noise kinds which can be generally classified into modulation and baseband types in DLC. The former noise type has constant noise phase which is originated from switching mode power supplies and the latter normally caused from thyristor circuit of low switching frequency is compared to be more dispersive than the other.

  • PDF

Twinax Cable Modeling for Use in HANbit ACE64 ATM Switching Systems (HANbit ACE64 ATM 교환기 시스템의 Twinax 케이블 모델링)

  • 남상식;박종대
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.12A
    • /
    • pp.1985-1991
    • /
    • 1999
  • In this paper, complete and general two-port lumped Spice-network model is developed for a lossy transmission line. This model is realized as a Spice subcircuit, by means of standard lumped network elements and mathematical functions. It is used as a component in the time-domain simulation of a high-speed data transmission line such as IMI(Inter Module Interface) data path in HANbit ACE 64 ATM switching system. The only required Spice network elements are resistance and frequency-dependent controlled-voltage sources. Such frequency-dependent sources are realized by utilizing the standard Hspice mathematical functions FREQ, DELAY, and POLY.

  • PDF

A new Method for Reducing Harmonics in Input AC Line Currents of Converter by 2-4 Switching taps on Interphase Reactor (상간리액터의 2-4? 변환 방식에 의한 콘버어터 입력 전류의 고조파 저감에 관한 연구)

  • 유철로;이공희;이성룡
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.37 no.1
    • /
    • pp.25-32
    • /
    • 1988
  • In this paper, a new method for reducing harmonics in input AC line currents of converter is presented, which is due mainly to the equipment of 2-4 switching taps on interphase reactor. When this method is applicable to conventional 12 pulse converter, the 24 pulse converter, the 24 pulse or 48 pulse converter is controlled by firing angles. The former is performe in 2 tap method when less than 15 degrees, and the letter in 4tap method when more than 15 degrees. Therefore, the proposed method has the advantages of reducing harmonics in full range of control angle and comparison with the conventional 3 tap method. We proved the validity of that theoretically and experimentally.

  • PDF

The Signal Anti-reduction System in PLC Using Ferrite Core and Switching Amplifier (페라이트 코어와 스위칭 증폭기를 이용한 PLC 신호 감쇠 저하 시스템)

  • Ko Jong-Sun;Kim Young-Il
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.471-474
    • /
    • 2001
  • In this paper, a communication system that is not using the communication line but power line is presented. It will be very useful for an information-oriented society with tole-metering and home automation. Conventional system has a difficulty in transmitting information due to decreasing communication voltage. Proposed idea is a special type switching amplifier system which has a low inner resistance and using high efficient ferrite core in a coupling circuit. This new system is proposed to overcome the loss of conductor load and coupling circuit in a PLC system.

  • PDF