• Title/Summary/Keyword: Line Standard

Search Result 1,744, Processing Time 0.028 seconds

On-Line Measurement System for the Determination of Chemical Oxygen Demand (화학적 산소 요구량 측정을 위한 On-Line 측정 시스템에 관한 연구)

  • 정형근;차기철
    • Journal of Environmental Science International
    • /
    • v.7 no.2
    • /
    • pp.203-208
    • /
    • 1998
  • A simple on-line measurement system consisting of a conventional peristaltic pump, a HPLC-type heater, and a flow-through spectrophotometer is introduced for the determination of chemical oxygen demand(CODI. The system was configured such that the reaction mixture in the highly concentrated surffuric acrid medium flowing through the PTFE reaction tubing was heated at 150℃ and the absorbance of dichromate was continuously moutored at 445 m. The same addation principle as in the standard procedure was employed akcept the use of CoSO4 as a new effective catalyst. To test the system, potassium hydrogen phthalate was selected as a COD standard material. With suitably optimized reaction condition, the applicable concentration range depends on the concentration of potassium dichromate in the oxidizing reagent. With 2.0×10-3 M and 5.0×10-4M dichromate, the linear dynamic range was observed up to 400 ppm and 100 ppm, respectively. The standards in the Unear ranges were shown to be completely oxidized, which was confirmed with sodium oxalate or Mohr's salt. In all cases, the typical reproduclbility for betweenruns was 2% or less. The proposed measurement system provides the valuable in- formation for the further development of automated analysis system based on the present standard procedure.

  • PDF

Analysis of Magnetic Fields induced by Line Currants using Coupling of FEM and Analytical Solution (선전류에 의해 발생되는 자장의 해석을 위한 유한요소법과 해석해의 결합 기법)

  • Kim, Young-Sun;Lee, Ki-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1035-1037
    • /
    • 2005
  • The analysis of magnetic fields(2-D) induced by line currents, such as Overhead Trolley Lines or Transmission Lines, is not so easy by using the standard Finite Element Method(FEM). Mesh generation is one of the most important processes in the standard FEM. Because, the current region is relatively small compared with whole region, and actually is a line without thickness, the mesh refinement around the source lines yields many demerits. A way of supplement such a defect, we proposed the coupling scheme of analytical solution and FEM. In this study, the analytical solution is adopted around the region of line currents and FE solution is a lied to the rest of source region. And the two types of solution are coupled at the artificial boundary. To verify the usefulness of proposed algorithm, simplified model with magnetic material in FE region is chosen and analyzed. The results are compared with those of standard FEM. And the errors between them can be reduced by increasing harmonic orders.

  • PDF

Optimization Condition for Injection Molding of TV Speaker Grille Using CAE (CAE를 이용한 TV Speaker Grille 사출 성형의 최적화)

  • 김범호;장우진;김정훈;정지원;박영훈
    • Polymer(Korea)
    • /
    • v.25 no.6
    • /
    • pp.855-865
    • /
    • 2001
  • The optimization condition of injection molding for a commercial product of TV speaker grille of A Company was induced using a CAE software of Moldflow. The flow and packing phase analysis was performed by using flow balance, runner balance, and the intermediate one by using the above two balances, which were used for controlling the amount of packing resins into the cavity, Later, the analysis performed by using the measured viscosity (local database) at various shear rates and the results were compared with the computer simulation using the standard database. Flow balance induced minimized weld line resulted in a better appearance and physical properties of the were line, but exhibited a disadvantage of large deformation and gas formation due to over-packing of the molten resin in the center of the speaker grille. Runner balance improved the disadvantage of the flow balance by controlling the amount of molten resin injected from the gate, however resulted reduced mechanical properties and poor appearance of the weld line. However, the modified method induced from the flow and runner balance improved the disadvantages by changing the runner size. In addition, the analyses based on the local database and the standard database were compared. Although the measured viscosity was slightly higher and the temperature distribution was broader than the standard database, no distinct difference was obtained from the analysis using the two different databases.

  • PDF

A Human Enginnering Study on an Original Pattern of Clothing for an Abnormal Type of Figure - with special reference to the of kyphosis - (이상체형의 의복원형의 인간공학적연구 - 척추만곡체형을 중심으로 -)

  • 박정순
    • Journal of the Korean Home Economics Association
    • /
    • v.20 no.3
    • /
    • pp.9-18
    • /
    • 1982
  • In this study, we attempted to make an original pattern of clothing for an abnormal type of figure, especially for the type of kyphosis. We measured the curvature of the spine of a woman with kyphosis with a Martin measuring instrument and a silhouetter in the following ways. First, we counted the rate of shrinkage of the standard lines drawn on the surface of the body according as the body moved. Secondly, placing the front and back darts, the front and back shoulder darts and the side darts according to“Munhwa”pattern, we made cubic cuttings of four moving postures as well as the standing one. Thirdly, we superposed the developed patterns of the standing and the moving postures, measuring the position change and the amount of the chaange of the darts, and compared them. The results are as follows: 1) In the developed pattern of a cubic cutting of the basic pattern and the standing posture, the neckhole became larger than that of the basic pattern, and the waist line was lowered than that of the basic pattern because the center back line was shortened due to the curved backbone. 2) As for the change of the standard line according to the movement, we found that the waist line, the center front line, the center back line, the bust width line, the upper back width line and the back width line became longer. Special consideration must be given to the function of the clothing for an abnormal type of figure. 3) The difference of the measurements between the cubic cutting and the body measurement regardless of the body movement is due to a gap by an acute angle at the jutted place between the developed pattern and the body surface. We found that the body measurement of the upper back width line, the back width line and the bust line became larger. Consequently, in making an original clothing pattern, it is desirable that we must not place the front and the back waist darts at the jutted place on the back from the functional and the aesthetic viewpoint of clothing. It is also desirable that we must widen the neckhole because the shoulder angle is close to a straight line due to a jut of the upper back width line.

  • PDF

Numerical Study on Improvement of Mixing Equipment' Plan in a Water Treatment Plant (수리해석을 이용한 정수장내 혼화장치 설계 개선에 관한 연구)

  • Oh, S.Y.;Hyun, D.S.;Oh, J.J.;Lee, S.H.;Lee, N.Y.
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.777-782
    • /
    • 2001
  • In this study, we used In-line orifice mixer for efficient chemicals mixing in water treatment. The method of using In-line orifice mixer has been already proved the improvement of water treatment efficiency. Numerical study was performed using FLUENT, a commercial code, to standard design and production of effective In-line orifice mixer. As variable for exactly standardizing, a proper ratio between an outer diameter of cone and a diameter of pipe, a distance between cone and orifice, a determination of orifice diameter for an optimal mixing, a distance between injection nozzle's position and cone, Numerical study has been performed for optimal standard and analyzed flow field on a basis of turbulent intensity in an orifice downstream.

  • PDF

A Study of the Development of Power System Model for Performance Test of Transmission Line Protective Relay (송전선로 보호용 보호계전기 시험을 위한 계통모델 개발에 관한 연구)

  • Seo H. C.;Lee H. H.;Kim C. H.;Lee J. W.;Jang B. T.;Gwak N. H.;Kim H. P.;Kim l. D.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.430-432
    • /
    • 2004
  • The standard power system model is needed to test a transmission line protective relay There are two methods to develop a power system model for transmission line protection. First method is based on characteristic power system model, and second method is based on functional power system model. This paper presents a standard power system model for performance test of transmission line protective relay, where the power system model is based on the two methods. And this model is simulated by using RTDS to test a protective relay.

  • PDF

Comparison of the Efficacy and Safety of EFGR Tyrosine Kinase Inhibitor Monotherapy with Standard Second-line Chemotherapy in Previously Treated Advanced Non-small-cell Lung Cancer: a Systematic Review and Meta-analysis

  • Qi, Wei-Xiang;Shen, Zan;Lin, Feng;Sun, Yuan-Jue;Min, Da-Liu;Tang, Li-Na;He, Ai-Na;Yao, Yang
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.10
    • /
    • pp.5177-5182
    • /
    • 2012
  • Purpose: To compare the efficacy and safety of epidermal growth factor receptor tyrosine kinase inhibitormonotherapy (EFGR-TKIs: gefitinib or erlotinib) with standard second-line chemotherapy (single agent docetaxel or pemetrexed) in previously treated advanced non-small-cell lung cancer (NSCLC). Methods: We systematically searched for randomized clinical trials that compared EGFR-TKI monotherapy with standard second-line chemotherapy in previously treated advanced NSCLC. The end points were overall survival (OS), progression-free survival (PFS), overall response rate (ORR), 1-year survival rate (1-year SR) and grade 3 or 4 toxicities. The pooled hazard ratio (HR) or risk ratio (RR), with their corresponding 95% confidence intervals (CI) were calculated employing fixed- or random-effects models depending on the heterogeneity of the included trials. Results: Eight randomized controlled trials (totally 3218 patients) were eligible. Our meta-analysis results showed that EGFR-TKIs were comparable to standard second-line chemotherapy for advanced NSCLC in terms of overall survival (HR 1.00, 95%CI 0.92-1.10; p=0.943), progression-free survival (HR 0.90, 95%CI 0.75-1.08, P=0.258) and 1-year-survival rate (RR 0.97, 95%CI 0.87-1.08, P=0.619), and the overall response rate was higher in patients who receiving EGFR-TKIs(RR 1.50, 95%CI 1.22-1.83, P=0.000). Sub-group analysis demonstrated that EGFR-TKI monotherapy significantly improved PFS (HR 0.73, 95%CI: 0.55-0.97, p=0.03) and ORR (RR 1.96, 95%CI: 1.46-2.63, p=0.000) in East Asian patients, but it did not translate into increase in OS and 1-year SR. Furthermore, there were fewer incidences of grade 3 or 4 neutropenia, febrile neutropenia and neutrotoxicity in EGFR-TKI monotherapy group, excluding grade 3 or 4 rash. Conclusion: Both interventions had comparable efficacy as second-line treatments for patients with advanced NSCLC, and EGFR-TKI monotherapy was associated with less toxicity and better tolerability. Moreover, our data also demonstrated that EGFR-TKImonotherapy tended to be more effective in East Asian patients in terms of PFS and ORR compared with standard second-line chemotherapy. These results should help inform decisions about patient management and design of future trials.

A Review of the Methods for Improving the Efficiency of Drive Motors to Meet IE4 Efficiency Standards

  • Dorrell, David G.
    • Journal of Power Electronics
    • /
    • v.14 no.5
    • /
    • pp.842-851
    • /
    • 2014
  • High efficiency standards are slowly being introduced with IE3 efficiency levels shortly becoming compulsory in many countries; IE4 efficiency levels being developed for future implementation. In this paper a review is carried out of the IE 60034-30 standard which covers standard line-start induction motors. Some design techniques that can be used to increase efficiency in order to meet the IE4 standards are discussed. This standard is now being replaced by the IE60034-30-1 standard which extends to other line start motors and also IE 60034-30-2 is being introduced to cover variable speed drives in order to address developing technology. The conclusion is that IE4 standards are obtainable but careful design is needed to reach this. Examples from the literature are given.

Theoretical Review to Draw Poverty Lines (빈곤가계의 복지지원을 위한 빈곤선 설정의 이론적 고찰)

  • 박명희
    • Journal of the Korean Home Economics Association
    • /
    • v.33 no.5
    • /
    • pp.63-73
    • /
    • 1995
  • Absolute poverty is redefined as biological existence level poverty and relative poverty is also redefinded as 'the state that relatively insufficient compared to the specific society's average living standard under the condition that basic needs on the biological existence level has been satisfied.' Then absolute poverty and relative poverty lies on the same welfare continuum. Therefore these two can be regarded as one unified concept. Theoretical bottom line of poverty is the biological existence level and ceiling is average income. Poverty line for the social policy is to be drawn between ceiling and floor. Using these standard lines three poverty bands are categorized : minimum subsistence level, minimum decency level.

  • PDF

The Standard for Installation of Automated Distribution Switch-gear in Multi-Line Faults (다중선로 고장을 고려한 배전자동화용 개폐기 설치기준)

  • Lee, Jung-Ho;Ha, Bok-Nam;Cho, Nam-Hun;Lim, Sung-Il
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1079-1081
    • /
    • 1999
  • This paper presents the standard for dividing/tieing the distribution lines and installing optimally the automated distribution switch-gear in multi-line faults. Also this paper recommends the distribution system design in consideration of the live load transfer of the concentrated load in the last load-side. This recommendation will be useful for designing the distribution network, developing the feeder automation software and operating the distribution automation system.

  • PDF