• Title/Summary/Keyword: Line Power Sensitivity

Search Result 134, Processing Time 0.023 seconds

A Study on the Reliability Evaluation for Interconnecting Power Systems in Northeast Asia (동북아 전력계통 연계를 위한 신뢰도 산정에 관한 연구)

  • Choi, Jae-Seok;Cha, Jun-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.7
    • /
    • pp.1129-1134
    • /
    • 2008
  • This paper proposes a reliability evaluation for interconnection planning using a tie line equivalent assisting generator model (TEAG) that considers the uncertainties of the interconnected transmission systems and the tie lines. Development of this model was triggered by the need to perform probabilistic reliability evaluations on the NEAREST (North East Asia Region Electric Systems Tied) interconnection. The TEAG is the basis for the newly developed interconnection systems reliability evaluation computer program, NEAREL. The model is capable of considering uncertainties associated with generators, tie lines, and the tied grids. Reliability evaluations for six interconnection scenarios involving the power systems of six countries in the Asian north eastern region were performed using NEAREL. Sensitivity analysis was used to determine reasonable tie line capacities for three interconnected country scenarios of the six countries. Test results and summarized comments of the scenarios are included in the paper.

A Fast Sensitivity Matrix Update Technique for Accurate Contingency Analysis State Computation Technique in Power Systems (정확한 상정사고 분석을 위한 민감도 행렬의 신속한 Update 기법에 관한 연구)

  • Lee, Seung-Chul;Kim, Kyoung-Shin;Kwon, Byong-Gook
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.327-329
    • /
    • 2001
  • This paper presents a fast and accurate contingency analysis in EHV systems for line outages, loss of generation of redispatching and loss-of-load or load management. Unlike other contingencies, line outage requires the modification of the Jacobian of the base case power flow and the calculation of its new inverse, which is substantially different from the original inverse. In this paper, we obtain the inverse of the new Jacobian from the original inverse without repeating the time consuming matrix inversion process. Numerical test results show the significant improvement in the accuracies compared with those obtained using the original inverse.

  • PDF

The Development of HFPD System for Mibile-loading Vehicles (차량탑재형 HFPD의 개발)

  • Kim, Deok-Geun;Im, Jang-Seop;Yeo, In-Seon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.33-37
    • /
    • 2001
  • Recently, the HFPD measurement testing is widely used in partial discharge measurement of HV machines because HFPD measurement testing receives less influence of external noise and has a merit of good sensitivity. Also HFPD testing is able to offer the judgement standard of degradation level of HV machine and can detect discharge signals in live-line. Therefore it is very useful method compare to previous conventional PD testing method and effective diagnosis method in power transformer that requires live-line diagnosis. But partial discharges have very complex characteristics of discharge pattern so it is required continuous research to development of precise analysis method. In recent, the study of partial discharge is carrying out discover of initial defect of power equipment through condition diagnosis and system development of degradation diagnosis using HFPD(High Frequency Partial Discharge) detection. In this study, simulated transformer is manufactured and HFPD occurred from transformer is measured with broad band antenna in real time, the degradation grade of transformer is analyzed through produced patterns in simulated transformer according to applied voltages.

  • PDF

A study on field test of diagnostic Monitoring System for Power Transformers (전력용 변압기 예방진단 시스템의 실 계통 적용 연구)

  • Kim, Y.H.;Lee, C.R.;HwangBo, S.W.;Shin, Y.T.;Park, G.C.;Park, K.S.
    • Proceedings of the KIEE Conference
    • /
    • 2004.05b
    • /
    • pp.91-93
    • /
    • 2004
  • This study presents recent trends on the on-line monitoring and diagnostic systems for oil-immersed transformers. Specially, our system on Yeo Su thermal power plant is introduced for high sensitivity and accuracy of ours. It is combined with communication networks to provide an on-line remote monitoring system. Several alarm criteria are formulated to enable a superimposed monitoring system to perform decisive action. The reasons for monitoring the condition and maintaining the health of electrical apparatus were discussed. The experience at the fields and the criteria for the judgment are also discussed in detail.

  • PDF

The Effect of Thyristor Controlled Series Capacitor(TCSC) on Power Transfer Capability (TCSC 투입계통의 송전용량 증대에 대한 연구)

  • Lee, Joo-Ho;Lee, Byoug-Jun
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.890-892
    • /
    • 1998
  • TCSC is a FACTS device that can control the active power flow and current of transmission lines by adjusting line impedances. In this paper, we study the effect of TCSC on power transfer capability. A static model of TCSC is implemented in the continuation power-flow(CPF) Program and the power transfer capability is measured using the CPF. The site of TCSC is selected to increase power transfer capability by the sensitivity information provided from the CPF. The effect of TCSC with various control mode is tested in IEEE New England 30-bus system.

  • PDF

Guidance system for abnormal situations of Power system (계통 이상상태 가이던스 시스템)

  • Seo, Gyu-Seok;Ok, Chi-Yun;Baek, Young-Sik;Kim, Jung-Nyun;Han, Moo-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.256-258
    • /
    • 2003
  • Recently, electric power demands tend to be increased continuously. In this situation, current states of power systems must be definitely recognized to operate power systems stably and economically. Also, corrective actions must be performed for the violation of bus voltage and line overload. It is desirable that the situations of violation are promptly removed to operate power systems effectively. This paper deals with the development of guidance system for voltage and overload correction on base case using Generator-Voltage Sensitivity List(GVSL) and Generator Shifter Factor List(GSFL). Also, to show the superiority and economical efficiency of the proposed application, we applied the proposed guidance system to the Kwangyang Steel Works' Power Systems.

  • PDF

A Sensitivity Measurement of Ultrasonic Signals by PZT Sensor (PZT 센서를 이용한 초음파 신호 감도측정)

  • 최인혁;권동진;윤장완;정길조
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.403-405
    • /
    • 1999
  • Power transformers have a tendency of ultra-high voltage and huge capacity as power demand increases day after day. Therefore, the fault by insulation destruction gives rise to large area of power failure in huge capacity transformers. On-line predictive diagnostics is very important In power transformers because of economic loss and its spreading effect. Hence, this study presents experiments of partial discharge method using ultrasonic sensor in order to confirm the possibility of ultrasonic sensor in power transformers. It carries out the experiments of measuring delay time between ultrasonic sensor and transducer, sensitiities by temperature change of oil and by barriers inside transformers. It is also Included wave analysis by ultrasonic sensor for needle-plate electrode powered on through high-voltage equipments.

  • PDF

Development of ultra-high frequency (UHF) ultra-wide bandwidth signal processing unit for UHF partial-discharge monitoring system for gas-insulated switchgears (가스절연개폐장치용 부분방전 감시 시스템을 위한 초광대역 극초단파 신호처리장치 개발)

  • Choi, Jae-Ok;Kim, Young-No;Lee, Young-Sang;Gang, Chang-Won;Park, Ki-Jun;Goo, Sun-Geun;Yoon, Jin-Yul;Koo, Jae-Yoon
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1963-1966
    • /
    • 2004
  • An ultra wide band ultra-high frequency (UHF) signal processing module was designed for on-line UHF partial discharge (PD) monitoring systems for gas-insulated switchgears (GIS). Major advantage of the unit is an improved PD detection sensitivity through minimizing the effect of surrounding interference signals. The detection sensitivity of the unit was <-60 dBm that is sufficient to detect UHF PD signals as low as 1 pC. Precise detection of PD occurred in the GIS, due to internal defects, is possible by using the signal processing unit.

  • PDF

A Nano-power Switched-capacitor Voltage Reference Using MOS Body Effect for Applications in Subthreshold LSI

  • Zhang, Hao;Huang, Meng-Shu;Zhang, Yi-Meng;Yoshihara, Tsutomu
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.1
    • /
    • pp.70-82
    • /
    • 2014
  • A nano-power CMOS voltage reference is proposed in this paper. Through a combination of switched-capacitor technology with the body effect in MOSFETs, the output voltage is defined as the difference between two gate-source voltages using only a single PMOS transistor operated in the subthreshold region, which has low sensitivity to the temperature and supply voltage. A low output, which breaks the threshold restriction, is produced without any subdivision of the components, and flexible trimming capability can be achieved with a composite transistor, such that the chip area is saved. The chip is implemented in $0.18{\mu}m$ standard CMOS technology. Measurements show that the output voltage is approximately 123.3 mV, the temperature coefficient is $17.6ppm/^{\circ}C$, and the line sensitivity is 0.15 %/V. When the supply voltage is 1 V, the supply current is less than 90 nA at room temperature. The area occupation is approximately $0.03mm^2$.

Development of ultra-high frequency (UHF) ultra-wide bandwidth signal processing unit for UHF partial-discharge monitoring system for gas-insulated switchgears (가스절연개폐장치용 부분방전 감시 시스템을 위한 초광대역 극초단파 신호처리장치 개발)

  • Choi, Jae-Ok;Kim, Young-No;Lee, Young-Sang;Kang, Chang-Won;Park, Ki-Jun;Goo, Sun-Geun;Yoon, Jin-Yul
    • Proceedings of the KIEE Conference
    • /
    • 2004.05b
    • /
    • pp.128-131
    • /
    • 2004
  • An ultra wide band ultra-high frequency (UHF) signal processing module was designed for on-line UHF partial discharge (PD) monitoring systems for gas-insulated switchgears (GIS). Major advantage of the unit is an improved PD detection sensitivity through minimizing the effect of surrounding interference signals. The detection sensitivity of the unit was <-60 dBm that is sufficient to detect UHF PD signals as low as 1 pC. Precise detection of PD occurred in the GIS, due to internal defects, is possible by using the signal processing unit.

  • PDF