• Title/Summary/Keyword: Line Check

Search Result 471, Processing Time 0.026 seconds

A Study on the Assembly Line Design Tool with a Pre/Post Process (전후 처리 기능을 포함하는 조립라인 설계 방법론)

  • Moon, Byoung-Hoon;Choi, Seong-Hoon
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.37 no.4
    • /
    • pp.98-105
    • /
    • 2014
  • According to a simple survey on the current status of the assembly line design, it was found that trial and error methods on the basis of experiences have been used mainly in domestic manufacturing industries, even though there exist a lot of excellent line balancing studies. It seems that more practical researches should be carried out to develop user-oriented line balancing tools especially for small and medium-sized enterprises. This study presents a design of the line balancing tool which can support the line balancing tasks of nonspecialists. The proposed design tool is composed of three major modules: pre-process, line balancing, and post-process. In particular, pre-process and post-process are newly proposed to increase its ease of use. We applied the proposed design to a test problem and test result showed that our practical method may contribute to enhance the efficiency of production operations management.

Experimental study on the deformation property of pneumatic tires - strain gauge method (실험적 방법에 의한 Tire 변형 특성 연구)

  • Kang, S.C.;Ku, B.H.
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.716-721
    • /
    • 2001
  • The present study describes the experimental method to measure the strain of tire. In this study. the strain distributions of tire with air pressure and vertical load were measured at the bead filler edge region and on the carcass cord using strain gauges and the results were compared with indoor bead durability test results. The strain amplitude of carcass cord near the rim check line of tire is one of the main factors that affects bead durability characteristic.

  • PDF

A Study on the Mechanical Behavior of Resilient Sleeper in Concrete Bed by Connection (콘크리트 도상 방진 침목의 연결재 유·무에 대한 역학적 거동 고찰)

  • Kim, Sung-Chil;Lee, Ki-Sung;Kim, Jun-Hung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.2 no.1
    • /
    • pp.121-128
    • /
    • 1998
  • The rail, which supports the train road, distributes the wheel loads to the tie by rail stiffness. Subway sleeper on concrete ballast is construction of PC or RC sleeper. The present, PC sleeper is constructed of line 1, 2, 3, 4 Seoul Subway and RC sleeper is planing construction for the STEDEF system on concrete ballast of the line 5, Seoul, Taegu, and Kwangju Subway. The major purpose of this study is to check influence of the angle with analysising the behavior of sleeper according to the existent or non-existent of angle. And the study is carried to check static analysis by manufacture of same model.

  • PDF

A Computational Analysis of Water-Hammer (수격현상에 대한 수치적 고찰)

  • Chun, Kwang-Min
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.11 no.1
    • /
    • pp.1-10
    • /
    • 1982
  • The water-hammer phenomena caused by pump power failure are analysed by digital computer. Asan cool ins water pipe system has been chosen as a model. It is Shown that after power failure the pressure at the pump outlet drops sharply, and to prevent reverse flow, either butterfly valve or check valve can be used. After the valve closure, pressure oscillates behind the valve. To weaken the pressure wave, it is recommended to install a servo-operated valve in a bypass Line around the pamp and the check valve.

  • PDF

Development of the Strip Off-center Meter Using Line Scan Camera in FM Line (라인 스캔 카메라를 이용한 압연라인의 판쏠림 측정장치 개발)

  • Yoo Ki-Sung;Lee Min-Choel;Choi Yong-Joon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.11 no.6
    • /
    • pp.518-523
    • /
    • 2005
  • Strip off-center is one of the major problems in hot strip mill line. The key to good centering is having good equipment, modern control systems, excellent maintenance and an understanding of milling process. Therefore, this study aims to develop a system that is useful for quantitative analysis of strip off-center. In this study, the measuring method of strip off-center was thoroughly studied and the exclusive control board to line scan camera were designed. Also, the manipulated type housing for line scan camera was developed to adjust initial parameters for strip width and center line. In order to check the accuracy and usefulness of the developed system, FM stand in $\#2$ Hot Strip Factory in Pohang Steel Works was targeted.

Study of Repair Effect of Anti-Alzheimer on $\beta$APP Overexpression In Neuroblastoma cell line by Ramulus et Uncus Uncariae (조구등이 $\beta$APP 과발현 인간 신경아세포암에서의 항치매 효과에 관한 연구)

  • Kim Sang Ho;Kang Won Hyung;Lyu Yeoung Su
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.16 no.5
    • /
    • pp.960-966
    • /
    • 2002
  • Ramulus et Uncus Uncariae (JGD) has sweet in flavour and slightly cold in property, acting on the liver and pericardium channels. This drug was described in a medical classic as having the ability to remove 'heat', check hyperfunction of the liver and relieve dizziness, tremors, and convulsions, and subdue 'endogenous wind'. So this study was estimated to check the anti-neuropathological effect of JGD on the Alzheimer in βAPP overexpression in neuroblastoma cell line and JGD extract was showed significantly anti-alzheimer effects (50 and 100 μg/㎖ of JGD extracts) compared with control group. Ramulus et Uncus Uncariae has anti-alzheimer effects on the βAPP overexpression in neuroblastoma cell line. So we expect that Ramulus et Uncus Uncariae may be used as a drug for neurodegenerative disease, such as stroke, Alzheimer's disease (AD). These results indicate that Ramulus et Uncus Uncariae possess strong inhibitory effect in the nervous system of apoptosis and repair effect against the degeneration of Neuroblastoma cells by βAPP expression.

Heterobeltiotic Genetic Interaction between Congenic and Syngenic Breeds of Silkworm, Bombyx mori L.

  • Verma A. K.;Chattopadhyay G. K.;Sengupta M.;Das S. K.;Sarkar A. K.
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.11 no.2
    • /
    • pp.119-124
    • /
    • 2005
  • To determine the level of heterosis, higher cocoon shell weight multivoltine congenic lines (Con. L) and bivoltine syngenic lines (Syn. L) of silkworm were used for crosses. First filial generations $(F_1s)$ expressed heterobeltiotic genetic interaction at significant magnitude (p < 0.01) for single cocoon shell weight (SCSW). The other linked characters viz., single cocoon weight (SCW) and yield by weight per 10, 000 larvae were also significantly higher (p < 0.01) than the better parental lines. All the hybrids showed significant improvement for these aforesaid characters over standard heterosis (Standard check). The reeling parameters viz., filament length, raw silk, neatness, cohesionstrokes etc, also showed improvement among the hybrids than check in congenial environment. Overall results suggested that the cross between congenic and syngenic lines provide better heterosis with good quality silk than conventional hybrids and may be used for commercial exploitation.

Utilizing Technology in Measurement System for Catenary Current: - Focusing on Testing Results for Kyoungbu High-speed Line in Korea - (조가선 전류 검측 시스템의 활용기술 연구 - 고속선 경부2단계 시험결과를 중심으로 -)

  • Park, Young;Jung, Hosung;Lee, Kiwon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.10
    • /
    • pp.1465-1469
    • /
    • 2013
  • The resent developed high speed train called HEMU-430X (Highspeed Electric Multiple Unit - 430km/h eXperiment) recorded a 421.4 km/h in Kyoungbu high speed line in Korea. A verity of measurement systems are used to check the performance between pantograph and catenary system. An innovative measurement system is adopted to check the current of catenary wire in the track side during HEMU-430X test running. This paper presents the measurement results of catenary current in kyoungbu high-speed line and describe its utilizing technology in the experimental results of catenary current. In order to analyze field testing results, the current ratio between contact and catenary current have been analyzed by means of Carson-Pollaczek equation. And the current wave forms between catenary and contact wire are presented based on the simulation results.

ACCURACY ASSESSMENT BY REFINING THE RATIONAL POLYNOMIALS COEFFICIENTS(RPCs) OF IKONOS IMAGERY

  • LEE SEUNG-CHAN;JUNG HYUNG-SUP;WON JOONG-SUN
    • Proceedings of the KSRS Conference
    • /
    • 2004.10a
    • /
    • pp.344-346
    • /
    • 2004
  • IKONOS 1m satellite imagery is particularly well suited for 3-D feature extraction and 1 :5,000 scale topographic mapping. Because the image line and sample calculated by given RPCs have the error of more than 11m, in order to be able to perform feature extraction and topographic mapping, rational polynomial coefficients(RPCs) camera model that are derived from the very complex IKONOS sensor model to describe the object-image geometry must be refined by several Ground Control Points(GCPs). This paper presents a quantitative evaluation of the geometric accuracy that can be achieved with IKONOS imagery by refining the offset and scaling factors of RPCs using several GCPs. If only two GCPs are available, the offsets and scale factors of image line and sample are updated. If we have more than three GCPs, four parameters of the offsets and scale factors of image line and sample are refined first, and then six parameters of the offsets and scale factors of latitude, longitude and height are updated. The stereo images acquired by IKONOS satellite are tested using six ground points. First, the RPCs model was refined using 2 GCPs and 4 check points acquired by GPS. The results from IKONOS stereo images are reported and these show that the RMSE of check point acquired from left images and right are 1.021m and 1.447m. And then we update the RPCs model using 4 GCPs and 2 check points. The RMSE of geometric accuracy is 0.621 m in left image and 0.816m in right image.

  • PDF

Cause Analysis of Flow Accelerated Corrosion and Erosion-Corrosion Cases in Korea Nuclear Power Plants

  • Lee, Y.S.;Lee, S.H.;Hwang, K.M.
    • Corrosion Science and Technology
    • /
    • v.15 no.4
    • /
    • pp.182-188
    • /
    • 2016
  • Significant piping wall thinning caused by Flow-Accelerated Corrosion (FAC) and Erosion-Corrosion (EC) continues to occur, even after the Mihama Power Station unit 3 secondary pipe rupture in 2004, in which workers were seriously injured or died. Nuclear power plants in many countries have experienced FAC and EC-related cases in steam cycle piping systems. Korea has also experienced piping wall thinning cases including thinning in the downstream straight pipe of a check valve in a feedwater pump line, the downstream elbow of a control valve in a feedwater flow control line, and failure of the straight pipe downstream of an orifice in an auxiliary steam return line. Cause analyses were performed by reviewing thickness data using Ultrasonic Techniques (UT) and, Scanning Electron Microscope (SEM) images for the failed pipe, and numerical simulation results for FAC and EC cases in Korea Nuclear Power Plants. It was concluded that the main cause of wall thinning for the downstream pipe of a check valve is FAC caused by water vortex flow due to the internal flow shape of a check valve, the main cause of wall thinning for the downstream elbow of a control valve is FAC caused by a thickness difference with the upstream pipe, and the main cause of wall thinning for the downstream pipe of an orifice is FAC and EC caused by liquid droplets and vortex flow. In order to investigate more cases, additional analyses were performed with the review of a lot of thickness data for inspected pipes. The results showed that pipe wall thinning was also affected by the operating condition of upstream equipment. Management of FAC and EC based on these cases will focus on the downstream piping of abnormal or unusual operated equipment.