• Title/Summary/Keyword: Line Beam

Search Result 811, Processing Time 0.03 seconds

Design of 5.8GHz Band 4×4 Butler Matrix using Commercial 90° Hybrid Coupler (상용 90도 하이브리드 커플러를 이용한 5.8GHz 대역 4×4 버틀러매트릭스 설계)

  • Park, Byeong-Hoon
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.3
    • /
    • pp.200-205
    • /
    • 2014
  • In this paper, 5.8GHz band $4{\times}4$ Butler matrix is designed using easily accessible commercial $90^{\circ}$ hybrid coupler and semirigid coaxial cable as a transmission line. This Butler matrix is very flexible to changes of antenna system specification like a frequency band because $90^{\circ}$ hybrid coupler changing is all to do. The result of design is the distance of $2{\times}2$ array antenna element is $\sqrt{2}{\lambda}/4$, the 4 beam directions are diagonal of array antenna and phase shifter is not necessary. The beam width is roughly $25^{\circ}$ narrower because of array antenna geometry and the side lobe is about 10dB higher partially than theoretical beam pattern. But the overall beam pattern is similar with theoretical beam. This Butler matrix can be applied to switching beam antenna of 5.8GHz band Wi-Fi and WAVE system.

Time-Dependent Degradation Model and Maintenance Cost of Rail line PC Beam Bridge in Project Level (Project level에서의 철도 PC Beam교량의 경년열화모델구성 및 유지관리비용 추정)

  • Kwon, Se-Gon;Park, Mi-Yun;Do, Jeong-Yun;Kim, Do-Kie
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.17-22
    • /
    • 2008
  • Construction project have extremely high risk in the process of construction owing to unexpected event, like as design amendment. As a result, owner have to endure enormous extra-cost to control the risk and continue to the project having more higher uncertainty. Also, if the structure is completed, it is needed that the structure is protected and maintained continuously during life cycle time to satisfying original aim of structure itself. LCC analysis to calculate cost of structure alternatives divides into two stage, one is design_LCC and the other is maintenace_LCC. But two stages all is needed in the transition deterioration model to calculate more reasonable LCC analysis. This paper developed the model using analysis of FMS contents and survey from professional about Prestressed concrete beam girder bridge(PC Beam bridge)in railway. The model is focused in project level of PC beam because any condition state information for element level analysis can not get up. This paper is intended to use the developed model in LCC analysis of PC Beam bridge in railway and constitute the foundation to perform more deep study in the near future.

  • PDF

A study of fabrication of LIPSS using flat-top beam with various materials (다양한 재질에서의 flat-top 빔을 이용한 LIPSS 형성에 관한 연구)

  • Choi, Jun-Ha;Choi, Won-Suk;Shin, Young-Gwan;Cho, Sung-Hak;Choi, Doo-Sun
    • Design & Manufacturing
    • /
    • v.15 no.3
    • /
    • pp.26-31
    • /
    • 2021
  • In this study, laser-induced periodic surface structure (LIPSS) was fabricated on Ni, Si, and GaAs samples using a flat-top beam with a uniform energy distribution that was fabricated using a Gaussian femtosecond laser with a mechanical slit and tube lens. Unlike the Gaussian beam, the flat-top beam has a uniform beam profile, therefore the center and the periphery of the fabricated LIPSS have similar line periodicity. In addition, LIPSS was obtained not only in metals but also in metalloids and metals and metalloid compounds by using the narrow pulse width characteristic of a femtosecond laser.

MURA Detection Method using a Slit-Beam-Profile Ellipsometer

  • Murai, Hideyuki;Ekawa, Koichi;Takashima, Jun;Naito, Hitoshi;Nakatsuka, Nobuo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.1465-1468
    • /
    • 2006
  • We developed a new ellipsometer for MURA detection. This ellipsometer can measure MURA along the slit line on the sample with high sensitivity, because this ellipsometer irradiates a slit beam onto the sample but can reject the reflected light from the back surface of the substrate. This ellipsometer is suitable for measuring MURA of the surface of sample with high sensitivity.

  • PDF

Simulation System of the CRT Deflection Yoke

  • Lee, Min-Soo;Woo, Duck-Kee;Cheun, Jong-Mok
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.392-394
    • /
    • 2002
  • Yoke simulator has been made for understanding beam movements in the deflection fields of the CRT. Consisting of the modeler, solver and post-processor, the simulator makes yoke model (conventional and rectangular yoke) and calculates charge sources and magnetic filed by BEM (boundary element method). This system supports a number of charge elements (line and surface charges) and beam movements can be predicted by the system.

  • PDF

A novel method of objectively detecting tooth ankylosis using cone-beam computed tomography: A laboratory study

  • Luciano Augusto Cano Martins;Danieli Moura Brasil;Deborah Queiroz Freitas;Matheus L Oliveira
    • Imaging Science in Dentistry
    • /
    • v.53 no.1
    • /
    • pp.61-67
    • /
    • 2023
  • Purpose: The aim of this study was to objectively detect simulated tooth ankylosis using a novel method involving cone-beam computed tomography (CBCT). Materials and Methods: Tooth ankylosis was simulated in single-rooted human permanent teeth, and CBCT scans were acquired at different current levels (5, 6.3, and 8 mA) and voxel sizes (0.08, 0.125, and 0.2). In axial reconstructions, a line of interest was perpendicularly placed over the periodontal ligament space of 21 ankylosed and 21 non-ankylosed regions, and the CBCT grey values of all voxels along the line of interest were plotted against their corresponding X-coordinates through a line graph to generate a profile. The image contrast was increased by 30% and 60% and the profile assessment was repeated. The internal area of the resulting parabolas was obtained from all images and compared between ankylosed and non-ankylosed regions under different contrast enhancement conditions, voxel sizes, and mA levels using multi-way analysis of variance with the Tukey post hoc test(α=0.05). Results: The internal area of the parabolas of all non-ankylosed regions was significantly higher than that of the ankylosed regions(P<0.05). Contrast enhancement led to a significantly greater internal area of the parabolas of non-ankylosed regions (P<0.05). Overall, voxel size and mA did not significantly influence the internal area of the parabolas(P>0.05). Conclusion: The proposed novel method revealed a relevant degree of applicability in the detection of simulated tooth ankylosis; increased image contrast led to greater detectability.

A New Approach with Combined Stereotactic Trans-multiarc Beams for Radiosurgery Based on the Linear Accelerator : Photon Knife (입체적횡다증회전조사를 병합한 방사선수술의 새로운 접근 : 포톤나이프)

  • Choi, Tae-Jin;Kim, Jin-Hee;Kim, Ok-Bae
    • Radiation Oncology Journal
    • /
    • v.14 no.2
    • /
    • pp.149-158
    • /
    • 1996
  • Purpose : To get an accute steepness of dose gradients at outside the target volume in intracranial lesion and a less limitation of beam selection avoiding the high dose at normal brain tissue, this Photon Knife Radiosurgery System was developed in order to provide the three-dimensional dose distribution through the reconstruction of CT scan and the combined stereotactic trans-multiarc beam mode based on linear accelerator photon beam. Materials and methods : This stereotactic radiosurgery, Photon Knife based on linear accelerator photon beam was provided the non-coplanar multiarc and trans-multiarc irradiations. The stereotactic trans-multiarc beam mode can be obtained from the patient position in decubitus. This study has provided the 3-dimensional isodose curve and anatomical structures with the surface rendering technique. The dose distribution from the combined two trans-multiarcs (2M 2TM) was compared to that of four non-coplanar multiarcs (4M) with same collimator size of 25 mm in a diameter and total gantry movements. Results : In this study, it shows that the dose distributions of stereotactic beam mode are significantly depended on the selected couch and gantry angle in same collimator size. Practical dose distribution of combined stereotactic trans-multiarc beam has shown a more small rim thickness than that of the non-coplanar multiarc beam mode in axial, sagittal and coronal plane in our study. 3-Dimensional dose line displayed with surface rendering of irregular target shape is helpful to determine the target dose and to predict the prognosis in follow-up radiosurgery. Conclusions : 3-Dimensional dose line displayed with surface rendering of irregular target shape is essential in stereotactic radiosurgery. This combined stereotactic trans-multiarc beam has shown a less limitation of the selection couch and gantry beam angles for the target surrounding critical organs. It has shown that the dose distribution of combined trans-multiarc beam greatly depended on the couch and gantry angles. In our experiments, the absorbed dose has been decreased to $27%$ / mm in maximum at the interval of $50\%$ to $80\%$ of isodose line.

  • PDF

Geometrically non-linear static analysis of a simply supported beam made of hyperelastic material

  • Kocaturk, T.;Akbas, S.D.
    • Structural Engineering and Mechanics
    • /
    • v.35 no.6
    • /
    • pp.677-697
    • /
    • 2010
  • This paper focuses on geometrically non-linear static analysis of a simply supported beam made of hyperelastic material subjected to a non-follower transversal uniformly distributed load. As it is known, the line of action of follower forces is affected by the deformation of the elastic system on which they act and therefore such forces are non-conservative. The material of the beam is assumed as isotropic and hyperelastic. Two types of simply supported beams are considered which have the following boundary conditions: 1) There is a pin at left end and a roller at right end of the beam (pinned-rolled beam). 2) Both ends of the beam are supported by pins (pinned-pinned beam). In this study, finite element model of the beam is constructed by using total Lagrangian finite element model of two dimensional continuum for a twelve-node quadratic element. The considered highly non-linear problem is solved by using incremental displacement-based finite element method in conjunction with Newton-Raphson iteration method. In order to use the solution procedures of Newton-Raphson type, there is need to linearized equilibrium equations, which can be achieved through the linearization of the principle of virtual work in its continuum form. In the study, the effect of the large deflections and rotations on the displacements and the normal stress and the shear stress distributions through the thickness of the beam is investigated in detail. It is known that in the failure analysis, the most important quantities are the principal normal stresses and the maximum shear stress. Therefore these stresses are investigated in detail. The convergence studies are performed for various numbers of finite elements. The effects of the geometric non-linearity and pinned-pinned and pinned-rolled support conditions on the displacements and on the stresses are investigated. By using a twelve-node quadratic element, the free boundary conditions are satisfied and very good stress diagrams are obtained. Also, some of the results of the total Lagrangian finite element model of two dimensional continuum for a twelve-node quadratic element are compared with the results of SAP2000 packet program. Numerical results show that geometrical nonlinearity plays very important role in the static responses of the beam.

Inelastic Buckling Behavior of Simply Supported I-Beam under Transverse Loading (횡방향 하중을 받는 I형강 단순보의 비탄성 좌굴거동)

  • Lee, Dong Sik;Oh, Soon Taek
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.1 s.68
    • /
    • pp.155-167
    • /
    • 2004
  • In this paper, the inelastic buckling behavior of the beam under uniform bending was investigated using the energy-based method, which can tackle problems in fourth order eigenvalue. The pattern of residual stress was not available to satisfy the I-sections manufactured in Korea. however; therefore, the well-known polynomial and simplified pattern of residual stress was adopted in this study. The inelastic lateral-distortional buckling behavior of the beam with I-sections manufactured in Korea was investigated. The study was then extended to the inelastic lateral-torsional buckling of the beam by minimizing the out-of-plane web distortion. The inelastic lateral-torsional buckling results obtained in this paper were compared with the prediction of allowable bending stress given in the Korean steel designers' manual (1995). Results showed that the importance of inelastic lateral-distortional buckling did not arise for beams under uniform bending. Likewise, the design method in KSDM (1995) was proven to bo too conservative for intermediate and short spans of beams without intermediate bracing.

POSITIONAL RELATIONSHIP OF THE MANDIBULAR CANAL AND IMPACTED THIRD MOLARS BY USING DENTAL CONE BEAM COMPUTED TOMOGRAPHY (제3대구치와 하악관과의 위치 관계에서 치과용 Cone beam CT의 유용성)

  • Chu, Yeon-Gyu;Park, Young-In;Kim, Jin-Wook;Lee, Sang-Han
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.6
    • /
    • pp.492-498
    • /
    • 2009
  • We sought to evaluate the relationship between the mandibular canal and impacted mandibular third molars by using dental cone beam computed tomograph(CBCT) for third molar surgery. A total of 111 patients(177 teeth) offered the images through CBCT and panoramic radiography for the extraction of the mandibular third molars. In CBCT, the accurate relationship between the third molar and the mandibular canal were evaluated. In panoramic radiographies, we evaluated the impacted level and superimposition sign of the mandibular third molar with the mandibular canal, and also, the radiopacity of the white line in the canal. Data were statistically analyzed and estimated by $X^2$-test. In CBCT finding, high prevalence of contact between the mandibular canal and roots occured in the deep impacted third molars, narrowing mandibular canals, bending mandibular canals and cases where the radiopacity of white line of canals were "absence" on panoramic images. It showed statistical significance (P<0.05). When evaluating the mandibular canal and the roots through the panoramic radiography for third molar extraction, it could be difficult to diagnosis accurately. Thus, it is required to have an accurate diagnostic approach through CBCT that could evaluated the location between mandibular canal and root.