The Study for Speed-up of Main Line by High Speed Train (기존선의 고속전철 연계운용으로 고속화 방안)

  • 박광복
    • Proceedings of the KSR Conference
    • /
    • 2001.05a
    • /
    • pp.105-113
    • /
    • 2001
  • This report was studied about speed-up for main line of KNR(Korea National Railroad) by High Speed Train. The maximum speed of Kyun-Pu line was recorded a 140km/h by Saemaul train in 1985 and the average speed its is a 107km/h now. For operation KTX Kyun-Pu High Speed Train and G7 Korea High Speed Train in KNR line, this report was studied about operation status of High Speed Train in advanced countries, operation situation of train in KNR line and plan of speed-up for main line.

  • PDF

Voltage Control Strategy of new 3-phase Line-Interactive UPS System using AC Line Reactor and Parallel-Serise Active Filter (AC 라인 리액터와 병렬 및 직렬 능동필터를 가지는 새로운 3상 Line-Interactive UPS 시스템의 전압제어 방식)

  • Ji, Jun-Keun
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.201-203
    • /
    • 2005
  • A new 3-phase line-interactive UPS(Uninterruptible Power Supply) system with parallel-series active power-line conditioning capability using AC line reactor and two four-leg PWM VSCs(Voltage Source Converters) was introduced recently, In this paper, the strategy of voltage control in suggested UPS system is explained. The objective of proposed voltage controllers in parallel(shunt) and series PWM VSC is to guarantee satisfactory characteristics in steady state and transient state.

  • PDF

A Comparative Study of Aha Tragus Line and Occlusal Plane in Edenturlous Patient (무치악 환자의 Ala tragus line과 교합평면에 관한 비교연구)

  • Chung, Moon-Kyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.27 no.1
    • /
    • pp.25-29
    • /
    • 1989
  • The author analized 17 complete denture patients with lateral cephalometric roentgenograms and following results were obtained: 1. The angle between the Ala tragus line and the occlusal plane was $4.38^{\circ}$. 2. The angle between the Ala tragus line and the Frankfort horizontal plane was $13.68^{\circ}$. 3. The line between the mouth corner and the retromolar pad was more parallel to the occlusal plane than the Ala tragus line.

  • PDF

Electrical Characteristics Evaluation of Transmission Line Arresters (송전선로용 피뢰기의 전기적 특성 평가)

  • Kim, Seok-Sou;Heo, Jong-Cheol;Mun, In-Wook;Oh, Chang-Su
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1498-1499
    • /
    • 2006
  • It has been reported that more than 50% of breakdown in transmission line for 154kV and above is due to lightning stroke. The flashover failure due to lightning stroke causes outage, voltage drop and instantaneous outage, Therefore line arrestors have been used in transmission line for protection from lightning stroke. In this paper, we describes electrical characteristics and performance test of line arrestor for transmission line.

  • PDF

Calculating Mutual Impedance between Power-Line and Communication-Line with Earth Return Current (대지귀로 전류에 의한 전력선과 통신선의 상호임피던스 해석)

  • Lim, Yong-Hun;Hyun, Duck-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.269-271
    • /
    • 2003
  • A method for calculation of mutual inductance from the parallel power-line and earth conduct to communication-line is studied in the paper. The solution for the electromagnetic field produced by an overhead power-line is derived using Maxwell's equations and treating the as a boundary value problem. Total mutual inductance from direct current and image current to communication-line is used Carson's formula for infinitely long parallel conductors.

  • PDF

3D Line Segment Extraction Based on Line Fitting of Elevation Data

  • Woo, Dong-Min
    • Journal of IKEEE
    • /
    • v.13 no.2
    • /
    • pp.181-185
    • /
    • 2009
  • In this paper, we are concerned with a 3D line segment extraction method by area-based stereo matching technique. The main idea is based on line fitting of elevation data on 2D line coordinates of ortho-image. Elevation data and ortho-image can be obtained by well-known area-based stereo matching technique. In order to use elevation in line fitting, the elevation itself should be reliable. To measure the reliability of elevation, in this paper, we employ the concept of self-consistency. We test the effectiveness of the proposed method with a quantitative accuracy analysis using synthetic images generated from Avenches data set of Ascona aerial images. Experimental results indicate that our method generates 3D line segments almost 7.5 times more accurate than raw elevations obtained by area-based method.

  • PDF

The On-Line Voltage Management and Control Solution of Distribution Systems Based on the Pattern Recognition Method

  • Ko, Yun-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • v.4 no.3
    • /
    • pp.330-336
    • /
    • 2009
  • This paper proposes an on-line voltage management and control solution for a distribution system which can improve the efficiency and accuracy of existing off-line work by collecting customer voltage on-line as well as the voltage compensation capability of the existing ULTC (Under Load Tap Changer) operation and control strategy by controlling the ULTC tap based on pattern clustering and recognition. The proposed solution consists of an ADVMD (Advanced Digital Voltage Management Device), a VMS (Voltage Management Solution) and an OLDUC (On-Line Digital ULTC Controller). An on-line voltage management emulator based on multi-thread programming and the shared memory method is developed to emulate on-line voltage management and digital ULTC control methodology based on the on-line collection of the customer's voltage. In addition, using this emulator, the effectiveness of the proposed pattern clustering and recognition based ULTC control strategy is proven for the worst voltage environments for three days.

Effects of Internet Addiction on On-line and Off-line Interpersonal Relationships (인터넷 중독 여부에 따른 온라인대인관계 성향과 대면대인관계 성향의 차이)

  • Kim, Kwang Woong;Yoo, Mi Sook;Lee, Jee Hang
    • Korean Journal of Child Studies
    • /
    • v.25 no.2
    • /
    • pp.109-120
    • /
    • 2004
  • This study examined the effects of Internet addiction on interpersonal relationships. The subjects were selected from 337 secondary school male students and data were collected with questionnaires. Data were analyzed with paired t-test and t-test. Result showed that there is a difference between on-line and off-line interpersonal relationships by Internet addiction. That is, internet addicted adolescents have more positive interpersonal relationships in on-line situations, while normal adolescents do not show any significant difference between on-line and off-line situations.

  • PDF

Quantitative Evaluation of Dislocation Density in Epitaxial GaAs Layer on Si Using Transmission Electron Microscopy

  • Kim, Kangsik;Lee, Jongyoung;Kim, Hyojin;Lee, Zonghoon
    • Applied Microscopy
    • /
    • v.44 no.2
    • /
    • pp.74-78
    • /
    • 2014
  • Dislocation density and distribution in epitaxial GaAs layer on Si are evaluated quantitatively and effectively using image processing of transmission electron microscopy image. In order to evaluate dislocation density and distribution, three methods are introduced based on line-intercept, line-length measurement and our coding with line-scanning method. Our coding method based on line-scanning is used to detect the dislocations line-by-line effectively by sweeping a thin line with the width of one pixel. The proposed method has advances in the evaluation of dislocation density and distribution. Dislocations can be detected automatically and continuously by a sweeping line in the code. Variation of dislocation density in epitaxial GaAs films can be precisely analyzed along the growth direction on the film.

Improved Ground differential relaying algorithm for the protection of a line-to-line fault of transformer (변압기의 선간 단락사고 보호를 위한 지락비율차동 계전 알고리즘의 성능향상 방법)

  • Kang, Hae-Gweon;Kim, Jin-Ho;Kim, Se-Chang;Park, Jong-Soo;Park, Jong-Eun
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.760-761
    • /
    • 2011
  • Ground differential relay is used to provide fast, sensitive, and selective protection for the wye connected and grounded electrical power equipment such as generators, power transformers, and grounding transformers. The ground differential protection only protects the ground faults within the protection zone, so that it can't protect the line-to-line fault. This paper proposes the algorithm to provide the protection for the line-to-line fault through the ground differential protection. The proposed algorithm detects the line-to-line fault of transformer using the comparison between the positive and the negative current, when the ground differential relay dose not operate. The performance of the algorithm is verified using a PSCAD/EMTDC simulator under various case studies.

  • PDF