• Title/Summary/Keyword: Limits of Stability

Search Result 351, Processing Time 0.026 seconds

Effects of Ankle Joint Taping on Postural Balance Control in Stroke Patients

  • Kim, Yang Rae;Kim, Jae Ic;Kim, Yong Youn;Kang, Kwon Young;Kim, Bo Kyoung;Park, Joo Hyun;An, Ho Jung;Min, Kyung Ok
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.3 no.2
    • /
    • pp.446-452
    • /
    • 2012
  • This study aims to examine the effects of taping of the ankle joint on the static and dynamic balance and gait ability of stroke patients. Twenty-six stroke patients receiving physical therapy at a hospital located in Gyeonggi-do were divided equally into a group that had taping in physical therapy and an ordinary physical therapy group. They exercised for 30 minutes each, 3 times per week for 8 weeks from June to August 2011. Romberg's eye open and eye closed tests, limits of stability(LOS), forward and back test, timed up and go test(TUG) and 10-meter gait velocity test were performed to evaluate static balance, dynamic balance, and gait ability, respectively, prior to and 8 weeks after the intervention. Differences within each group in relation to the lapse of time were compared by a paired t-test. Differences between the two groups were compared by an independent t-test. Regarding comparison of differences within each group, all tests resulted in significant changes in both groups after the intervention (p<.05). Comparison of differences between the two groups showed that taping in the physical therapy group had significantly better test results than the ordinary physical therapy group in all measured items(p<.05). The after effects of ankle taping on stroke patients are more efficient and effective than ordinary physical therapy alone in improving balance and gait ability.

A Study of Historical Background to the National Forest Formation (국유림성립(國有林成立)의 사적배경(史的背景)에 관(關)한 고찰(考察))

  • Ho, Ul Yung
    • Journal of Korean Society of Forest Science
    • /
    • v.31 no.1
    • /
    • pp.21-29
    • /
    • 1976
  • In foreign countries the national forests began to emerge when the modern body politic came into being and looked upon forests as an indispensible source of national wealth to the effect that eachnation virtually nationalized the forests to promote the public interest such as erosion prevention and water source stability. Most of the forests that are now in national ownership used to be the estates of kings and feudal lords in the Middle Ages. In Korea in national forests come into being toward the end of Yi-dynasty as an outcome of the Japanese colonial policy under which, with the purpose of exploiting the forest resources, the dense forests of large area were systematically transferred into national property to be controlled by establishing the echelon of the national forest stations. The main task of these stations was to fell lumber to no limits.

  • PDF

Effects of Visual Cue Deprivation Balance Training with Head Control on Balance Function and Fall Index in Older People

  • Kim, Seung-Kyu;Lee, Do-Youn;Nam, Seung-Min
    • The Journal of Korean Physical Therapy
    • /
    • v.34 no.5
    • /
    • pp.212-217
    • /
    • 2022
  • Purpose: This study sought to investigate the effects of visual cue deprivation balance training by applying head control feedback to the balance function and the fall index in older people. Methods: The study was conducted on 26 older people at the S Hospital in Gyeongsansi. The patients were randomly divided into the experimental groupI (EGI, n=9), the experimental groupII (EGII, n=9), and the control group (CG, n=8). The three groups were trained for 30 minutes three times a week for four weeks. To assess the patients' static balance function, their limits of stability (LOS) was measured using the BioRescue system, (RM Ingenierie, France), composed of a pressure platform that can measure force in diverse ways, a computer, and a monitor. The dynamic balance function was measured using the Berg Balance Scale (BBS). Also, the fall index was measured to evaluate the risk of falling. A paired t-test was performed to compare pre- and post-training performance within the groups. One-way ANOVA was performed for comparing the three groups. A post hoc least significant difference (LSD) test was also performed. Results: The results of the LOS showed a significant difference after training in the EGI and EGII groups (p<0.05). As a result of the difference between the three groups, there was a significant difference after training (p<0.05). The results of the BBS showed a significant difference after training in the EGI group (p<0.05). As a result of the difference between the three groups, there was a significant difference after training (p<0.05). Conclusion: Visual cue deprivation balance training applying head control feedback is effective in improving the dynamic balance function in older people. It is also necessary to constantly maintain the head orientation by feedback and to properly control the head movement.

Lumped Track Modeling for Estimating Traction Force of Vecna BEAR Type Robot (Vecna BEAR 형 로봇의 견인력 추정을 위한 Lumped 궤도 모델링)

  • Kim, Tae Yun;Jung, Samuel;Yoo, Wan Suk
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.3
    • /
    • pp.275-282
    • /
    • 2015
  • Recently, Vecna BEAR type robot to save injured individuals from inaccessible areas has been developed to minimize the loss of life. Because this robot is driven on rough terrain, there is a risk of rollover and vibration, which could impact the injured. In order to guarantee its stability, an algorithm is required that can estimate the speed limits for various environments in real time. Therefore, a dynamic model for real-time analysis is needed for this algorithm. Because the tracks used as the driving component of Vecna BEAR type robot consist of many parts, it is impossible to analyze the multibody tracks in real time. Thus, a lumped track model that satisfies the requirements of a short computation time and adequate accuracy is required. This study performed lumped track modeling, and the traction force was verified using RecurDyn, which is a dynamic commercial program.

Probabilistic Security Analysis in Composite Power System Reliability (복합전력계통 신뢰도평가에 있어서 확률론적 안전도연구)

  • Kim, H.;Cha, J.;Kim, J.O.;Kwon, S.
    • Proceedings of the KIEE Conference
    • /
    • 2005.11b
    • /
    • pp.46-48
    • /
    • 2005
  • This paper discusses a probabilistic method for power system security assessment. The security analysis relates to the ability of the electric power systems to survive sudden disturbances such as electric short circuits or unanticipated loss of system elements. It consists of both steady state and dynamic security analyses, which are not two separate issues but should be considered together. In steady state security analysis including voltage security analysis, the analysis checks that the system is operated within security limits by OPF (optimal power flow) after the transition to a new operating point. Until now, many utilities have difficulty in including dynamic aspects due to computational capabilities. On the other hand. dynamic security analysis is required to ensure that the transition may lead to an acceptable operating condition. Transient stability, which is the ability of power systems to maintain synchronism when subjected to a large disturbance. is a principal component in dynamic security analysis. Usually any loss of synchronism may cause additional outages and make the present steady state analysis of the post-contingency condition inadequate for unstable cases. This is the reason for the need of dynamic studies in power systems. Probabilistic criterion can be used to recognize the probabilistic nature of system components while considering system security. In this approach. we do not have to assign any predetermined margin of safety. A comprehensive conceptual framework for probabilistic static and dynamic assessment is presented in this paper. The simulation results of the Western System Coordinating Council (WSCC) system compare an analytical method with Monte-Carlo simulation (MCS).

  • PDF

The Modified Electrode by PEDOP with MWCNTs-Palladium Nanoparticles for the Determination of hydroquinone and Catechol

  • Naranchimeg, Orogzodmaa;Kim, Seul-Ki;Jeon, Seung-Won
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.8
    • /
    • pp.2771-2775
    • /
    • 2011
  • Poly-ethylenedioxypyrrole (PEDOP) coated thiolated multiwall carbon nanotubes palladium nanoparticles (MWCNTs-Pd) modified glassy carbon electrode (GCE) [PEDOP/MWCNTs-Pd/GCE] for the determination of hydroquinone (HQ) and it’s isomer catechol (CA) were synthesized and compared with bare GCE and thiolated multiwall carbon nanotubes (MWCNTs-SH/GCE). The modification could be made by simple processes on a GCE with MWCNTs-Pd covered by PEDOP in a 0.05 M tetrabutylammonium perchlorate (TBAP)/MeCN solution system. A well-defined peak potential evaluation of the oxidation of hydroquinone to quinone at 0.05 V (vs. Ag/AgCl), and electrochemical reduction back to hydroquinone were found by cyclic voltammetry (CV) in phosphate buffered saline (PBS) at pH 7.4. Peak current values increased linearly with increasing hydroquinone contents. The peak separation between the anodic and cathodic peaks at the PEDOP/MWCNTs-Pd/GCE was ${\Delta}Ep$ = 40 mV for HQ and ${\Delta}Ep$ = 70 mV for CA, resulting in a higher electron transfer rate. Moreover, good reproducibility, excellent storage stability, a wide linear range (0.1 ${\mu}M$ - 5 mM for HQ and 0.01 ${\mu}M$ - 6 mM for CA), and low detection limits ($2.9{\times}10^{-8}$ M for HQ and $2.6{\times}10^{-8}$ M for CA; S/N = 3) were determined using differential pulse voltammetry (DPV) and amperometric responses; this makes it a promising candidate as a sensor for determination of HQ and CA.

Comparison of Nitrate and Fluoride Removals between Reverse-Osmosis, Nano-Flitration, Electro-Adsorption, Elecero-Coagulation in Small Water Treatment Plants (소규모 수도시설의 역삼투(RO), 나노여과(NF), 전기흡착(EA), 전기응집(EC) 공정의 질산성 질소 및 불소 이온 제거 성능 비교)

  • Han, Song-Hee;Chang, In-Soung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.4
    • /
    • pp.2027-2036
    • /
    • 2013
  • Comparison of removal performance between reverse osmosis(RO), nanofiltration(NF), electrocoagulation(EC) and electroadsorption(EA) for removal of nitrate and fluoride often exceeded the limits of water quality in small water treatment plants. Removals of nitrate and fluoride were 72-92% and 74-85% in RO, 5-15% and 1% in NF, 99% and 44% in EA equipped with MWCNT coated electrodes, 82% and 77% in EA equipped with Cu-MWCNT electrodes, and 11-46% and 69-99% in EC. Consequently, high removals of both ions were anticipated in RO. Effective removal of both ions are possible for EC, but great production of sludge is a big burden. EA equipped with the MWCNT electrodes showed a great fluctuation in removal efficiency, and electrode stability should be upgraded.

Effects of Aquatic and Ground Obstacle Training on Balance and Muscle Activity in Patients With Chronic Stroke

  • Hwang, Hyun-chul;Kim, So-hee;Kim, Tae-ho
    • Physical Therapy Korea
    • /
    • v.26 no.4
    • /
    • pp.35-41
    • /
    • 2019
  • Background: Obstacle training affects lower limb muscle activity, balance, reducing the risk of falls, and making gait more stable. Objects: This study aimed to investigate the effects of aquatic and ground obstacle training on balance and muscle activity in patients with chronic stroke. Methods: The study subjects included 30 patients with stroke, who were divided into aquatic ($n_1=15$) and ground ($n_2=15$) groups. Groups underwent obstacle training three times per week, 30 min per session, for six weeks that went as follows: walking over sites with the paralyzed leg, stepping onto and down from a box step, and walking over obstacles with the non-paralyzed leg. Results: The experimental results were obtained by comparing muscle activity. Activity of the rectus femoris, biceps femoris, tibialis anterior, and gastrocnemius were significantly increased in the aquatic group (p<.05). Activity of the biceps femoris and tibialis anterior were significantly increased in the ground group (p<.05); however, the rectus femoris and gastrocnemius were not significantly different. In the comparison of maximal distance regarding the limits of stability, it was significantly increased on the non-affected side, affected side, and anterior and posterior distance in the aquatic group (p<.05). It was significantly increased in the non-affected side and anterior and posterior distance the ground group (p<.05); however, maximal distance on the affected side distance was not significantly different. Conclusion: Gait training with aquatic and ground obstacles is effective for improving balance and gait ability of patients with stroke. However, it was more effective for the aquatic group than for the ground group.

Sensory evaluation of a body lotion formulated with hot spring water from Deokgu, Korea (덕구온천수로 제조된 바디로션의 관능평가)

  • Kim, So Jung;Kang, Mingyeong;Lee, Taek-Kyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.4
    • /
    • pp.420-427
    • /
    • 2019
  • The purpose of this study was to evaluate hot spring water (HSW) from Deokgu as a cosmetic ingredient in the preparation of a body lotion. The HSW was tested for its suitability as an aqueous-phase main component. Microbiological and chemical stability tests of the HSW were carried out. Microorganisms including E. coli were not detected or detected below the detection limits, and no harmful heavy metals were found. The cytotoxicity of the HSW was also considered, and its pH determined over a period of three months. Further, sensory characteristics were assessed for consumer acceptance by performing sensory tests on body lotions formulated using either Deokgu HSW or distilled water. Skin moisturization, irritation and tension reinforcement were found to be enhanced when using the HSW lotion rather than that formulated with distilled water. Taken together, the results of this study show that the use of HSW in cosmetic formulations contributes to the efficacy of these products.

p-type CuI Thin-Film Transistors through Chemical Vapor Deposition Process (Chemical Vapor Deposition 공정으로 제작한 CuI p-type 박막 트랜지스터)

  • Seungmin Lee;Seong Cheol Jang;Ji-Min Park;Soon-Gil Yoon;Hyun-Suk Kim
    • Korean Journal of Materials Research
    • /
    • v.33 no.11
    • /
    • pp.491-496
    • /
    • 2023
  • As the demand for p-type semiconductors increases, much effort is being put into developing new p-type materials. This demand has led to the development of novel new p-type semiconductors that go beyond existing p-type semiconductors. Copper iodide (CuI) has recently received much attention due to its wide band gap, excellent optical and electrical properties, and low temperature synthesis. However, there are limits to its use as a semiconductor material for thin film transistor devices due to the uncontrolled generation of copper vacancies and excessive hole doping. In this work, p-type CuI semiconductors were fabricated using the chemical vapor deposition (CVD) process for thin-film transistor (TFT) applications. The vacuum process has advantages over conventional solution processes, including conformal coating, large area uniformity, easy thickness control and so on. CuI thin films were fabricated at various deposition temperatures from 150 to 250 ℃ The surface roughness root mean square (RMS) value, which is related to carrier transport, decreases with increasing deposition temperature. Hall effect measurements showed that all fabricated CuI films had p-type behavior and that the Hall mobility decreased with increasing deposition temperature. The CuI TFTs showed no clear on/off because of the high concentration of carriers. By adopting a Zn capping layer, carrier concentrations decreased, leading to clear on and off behavior. Finally, stability tests of the PBS and NBS showed a threshold voltage shift within ±1 V.