• Title/Summary/Keyword: Limited of stability

Search Result 791, Processing Time 0.026 seconds

A Study on Reliability of Liquid-Crystal for Smart Window (액정 스마트윈도우의 신뢰성에 대한 연구)

  • Park, Byung-Kyu;Kim, Sun-Geum;Lee, Seung-Woo;Park, Gye-Choon;Lee, Jin
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.33 no.6
    • /
    • pp.471-474
    • /
    • 2020
  • In recent years, the challenge of higher energy efficiency has emerged as urban buildings have become taller, and the area of window glasses has increased. To address the problem of energy efficiency in buildings, research on smart windows is being actively conducted. In this study, an accelerated experiment for thermal stability was conducted to fabricate a liquid crystal cell applicable to external windows. It was confirmed from the study that the function is maintained even in a high-temperature external environment through the change in transmittance by voltage. Compared with the initial transmittance, after the passage of time, the smart window cell to which the sealant was applied showed a small change in transmittance of 1~2%. This result confirmed the thermal stability of the liquid crystal-based smart window.

The Immediate Effects of Static Stretching with Talus Stability Taping on Ankle Dorsiflexion and Balance (목말뼈 안정화 테이핑을 동반한 정적 장딴지근 스트레칭이 발목 관절의 발등굽힘과 균형에 미치는 즉각적인 효과)

  • An, Da-In;Jung, Jong-Chul;Park, Won-Young;Kim, Soo-Yong
    • PNF and Movement
    • /
    • v.19 no.1
    • /
    • pp.87-95
    • /
    • 2021
  • Purpose: The purpose of this study was to determine the effects of talus stability taping during gastrocnemius stretching on ankle passive dorsiflexion, talus posterior glide, and balance in subjects with limited ankle dorsiflexion. Methods: Fifteen subjects (eight males and seven females) with limited ankle dorsiflexion participated in this study. Ankle passive dorsiflexion range of motion (ROM), talus posterior glide, and the lower quarter Y-balance test (YBT-LQ) were measured pre-stretching, after applying gastrocnemius stretching (GS), and after applying gastrocnemius stretching with talus stability taping (GSTST). The two types of stretching were performed at random. Results: Ankle passive dorsiflexion ROM was significantly increased by both types of stretching (p < 0.05), and ROM was significantly more increased post-GSTST than post-GS (p < 0.05). In addition, talus posterior glide was significantly increased post-GSTST than pre-stretching and post-GS (p < 0.05). However, there was no significant difference between post-GS and pre-stretching (p > 0.05). YBT-LQ score was significantly increased post-GSTST than pre-stretching (p < 0.05). Conclusion: Gastrocnemius stretching with talus stability taping is an effective method for subjects with limited ankle dorsiflexion to improve ankle passive dorsiflexion, talus posterior gliding, and balance.

Now Techniques Of Digital Simulation Of Multimachine Power Systems For Dynamic Stability By Memory-Limited Computer (소형전자계산기에 의한 다기전력계통의 동적안정도 해석)

  • Young Moon Park
    • 전기의세계
    • /
    • v.23 no.1
    • /
    • pp.73-78
    • /
    • 1974
  • Digital simulation algorithms and program for multimachine dynamic stability have been developed which represent the effects of machines much more complety than have been available previously. Emphasis is given to the savings of the memory spaces required, thus making it possible to use a small computer with limited capacity of core storage (without auxiliary storage). Both d- and q- aris quantities are fully represented, and the speed-governing and voltage-regulating system available are ertensive, thus allowing a very close approximation to any physical system. Facilities for dynamic and nonlinear loads are also included. The computational algorithms and program developed have been shown to be extensive and complete, and are very desirable features minimizing memory spaces for stability calculations. The capabilities have been demonstrated by several case studies for an actual power system of 44 generators, 22 loads and 33 buses. About 13-K words of memory spaces have been required for the case studies on the basis of two words per real variable and a word per integer variable.

  • PDF

Relaxing of the Sampling Time Requirement in Prove of the EDMC Stability

  • Haeri, Mohammad;Beik, Hossein Zadehmorshed
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1829-1832
    • /
    • 2004
  • Closed loop stability of Extended Dynamic Matrix Control (EDMC) is investigated for limited sampling time. Linear approximation of the sensitivity functions is employed in the derivation of the stability condition. It is shown that the closed loop system will be stable if the control moves suppression coefficient ${\lambda}$ is taken arbitrarily large. Special cases such as M=P=1 and M=1, P>1 are discussed in more details.

  • PDF

Fall Risk Assessments Based on Postural and Dynamic Stability Using Inertial Measurement Unit

  • Liu, Jian;Zhang, Xiaoyue;Lockhart, Thurmon E.
    • Safety and Health at Work
    • /
    • v.3 no.3
    • /
    • pp.192-198
    • /
    • 2012
  • Objectives: Slip and fall accidents in the workplace are one of the top causes of work related fatalities and injuries. Previous studies have indicated that fall risk was related to postural and dynamic stability. However, the usage of this theoretical relationship was limited by laboratory based measuring instruments. The current study proposed a new method for stability assessment by use of inertial measurement units (IMUs). Methods: Accelerations at different body parts were recorded by the IMUs. Postural and local dynamic stability was assessed from these measures and compared with that computed from the traditional method. Results: The results demonstrated: 1) significant differences between fall prone and healthy groups in IMU assessed dynamic stability; and 2) better power of discrimination with multi stability index assessed by IMUs. Conclusion: The findings can be utilized in the design of a portable screening or monitoring tool for fall risk assessment in various industrial settings.

A Unified Framework for Small Signal Stability Analysis of Power Systems and Its Application to Available Transfer Capability (계통의 종합적 미소신호 안정도 해석 알고리듬과 ATC 산정에의 응용에 관한 연구)

  • Kim, Sang-Ahm;Song, Hwa-Chang;Lee, Byong-Jun;Kwon, Sae-Hyuk
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.10
    • /
    • pp.1222-1230
    • /
    • 1999
  • This paper presents the framework for analysis of small-signal stability. In this framework the equilibrium points of system DAE model are traced using continuation method and instability points are determined on the solution path. Especially Implicit shift QR-modified Arnoldi method is utilized to calculated the rightmost eigenvalues. Small-signal stability is becoming one of the major factors that affect the ATC in the environment of deregulation. Stability limited ATC is easily evaluated in this stability analysis process.

  • PDF

A Study on Characteristics of Liquid-Crystal Based Cell for Smart Window (액정 기반 스마트 윈도우용 셀의 특성 연구)

  • Park, Byung-Gyu;Kim, Sun-Keum;Lee, Seung-Woo;So, Soon-Yeol;Lee, Jin
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.33 no.4
    • /
    • pp.271-275
    • /
    • 2020
  • Smart windows are used as windows and doors to determine the cooling and heating efficiency of a building. They have characteristics that can increase the energy efficiency of a building, which leads to energy savings. In addition, smart windows can control the amount of light transmitted from the external environment of a building to the interior of a building according to the needs of the user. In this study, a 297×210 ㎟ liquid crystal cell capable of controlling light transmittance was fabricated using a liquid crystal device as an optical shutter. The effect of driving voltage on the transmittance and the effect of the thermal environment on the driving stability were analyzed. We confirmed the applicability of using smart windows as exterior building materials.

Study on the Effect of Quantitative and Qualitative Easing(QQE) in Japan (日本の量的·質的金融緩和(QQE)の効果について)

  • Yeom, Dongho
    • Analyses & Alternatives
    • /
    • v.2 no.2
    • /
    • pp.143-162
    • /
    • 2018
  • This paper focuses on the policy framework about "Quantitative and Qualitative Easing (QQE)" of Japan, and analyzes reasons why the policy goal was not reached. The QQE was introduced by the Bank of Japan in 2013 with the purpose of meeting the price stability target of 2% and getting out of deflation that prevents sustained price decline. However, despite the implementation of the bold monetary easing policy unprecedented in the world, the policy goal was not achieved as of June 2018. As a result of analyzing the causes, the following three structural factors were confirmed. 1) The rise in prices by QQE was limited because Japan's consumer price is strongly depending on import price. 2) The effect is high degree of uncertainty and limited because theoretical framework of reflationist which adopted QQE depends on "expectation formation" by "self-fulfilling expectation" and "multiple equilibria". 3) It was confirmed that the expansion of the monetary base did not lead to money stock due to the existence of Japanese liquidity trap, long-term low interest rate policy.

  • PDF

Influence of Transcranial Direct Current Stimulation on Lower Limb Muscle Activation and Balance Ability in Soccer Player

  • Yang, Dae Jung;Park, Seung Kyu;Uhm, Yo Han
    • The Journal of Korean Physical Therapy
    • /
    • v.30 no.6
    • /
    • pp.211-217
    • /
    • 2018
  • Purpose: This study is to investigate influence of tDCS on lower limb muscle activity and balance ability in soccer player. Methods: Sessions were conducted with 15 subjects in tDCS group and 15 in action observation training group for 20 minutes, 5 sessions a week, for 8 weeks. All soccer players underwent 30 minutes of plyometric training before main exercise. To evaluate lower limb muscle activation, rectus femoris and biceps femoris were taken measure using surface electromyogram system and to evaluate balance ability, surface area, whole path length, limited of stability were measured using biorescue. Results: Regarding balance shown in surface area, whole path length, limited of stability and muscle activation in rectus femoris and biceps femoris, tDCS group showed more significant change than action bservation training group. Conclusion: Therefore, intervention using tDCS is more effective in improving lower limb muscle activation and balance ability than action observation training.