• Title/Summary/Keyword: Limit of detection(LOD)

Search Result 297, Processing Time 0.022 seconds

Analysis of caffeine in aqueous sample by hollow fiber-liquid microextraction (HF-LPME) (HF-LPME를 이용한 수용액 시료중의 카페인 분석)

  • In, Chi-Yeon;Kim, Taek-Jae;Myung, Seung-Woon
    • Analytical Science and Technology
    • /
    • v.21 no.2
    • /
    • pp.84-92
    • /
    • 2008
  • A method for the determination of trace amount of caffeine in urine and various drink samples using hollow fiber-liquid phase microextraction (HF-LPME) and capillary gas chromatograph/nitrogen phosphorus detector (GC/NPD) has been established. HF-LPME method has been optimized with respect to several experimental parameters including the effects of the hollow fiber length, extraction solvent, stirring mode, pH and salt concentration for the determination of caffeine from aqueous samples. The correlation coefficient of calibration curve for caffeine was 0.9994. The average recovery was 102%(n=3). The established method is feasible for the determination of trace amounts of caffeine in several aqueous sample. The limit of detection (LOD) and the limit of quantitation (LOQ) have been found to be 2.5 and 10 ng/mL, respectively. The established HF-LPME method for the analysis of caffeine from aqueous sample can be used for the determination of biological, food and environmental samples.

Mulberry Paper Bag μ-Solid Phase Extraction for the Analysis of Five Spice Flavors by Gas Chromatography-Mass Spectrometry

  • Yoon, Ok-Kyung;Lee, Dong-Sun
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.1
    • /
    • pp.35-42
    • /
    • 2009
  • Headspace micro solid phase extraction using mulberry paper bag (HS-MPB-$\mu$-SPE) has been developed and validated for the analysis of volatile flavor compounds from five spice by gas chromatography-mass spectrometry (GC/MS). HS-MPB-$\mu$-SPE was performed with adsorbent particles enclosed inside a mulberry paper bag. Four different kinds of adsorbents such as Tenax TA, Porapack Q, dimethylpolysiloxane and polyethylene glycol were tested. The extraction solvents compared were petroleum ether, methylene chloride, and chloroform. Better results were obtained when Tenax TA and petroleum ether were used. The limit of detection (LOD) and the limit of quantitation (LOQ) were in the range of 1.3 ng/mL and 4.3 ng/mL, respectively, for o-cymene as a model compound of monoterpene. Proposed method showed good reproducibility (3.3%, RSD) and good recoveries (94.0%). The HS-MPB- μ-SPE is very simple to use, inexpensive, rapid, requires small sample amounts and solvent consumption. Because the solvent for extraction is reduced to only a very small volume (0.6 mL), there is minimal waste or exposure to toxic organic solvent and no further concentration step. This method allows successful characterization of the headspace in contact with the five spice sample. Strong trans-anethole from star anise or fennel is a characteristic flavor of five spice powders. HS-MPB-$\mu$-SPE combined with GC/MS can be a promising technique for the broad spectrum measurement of volatile aroma compounds from solid spices.

Analysis of Penicillin Antibiotics in Aquatic Products (수산물 중 penicillin계열 항생제의 분석)

  • Bae, Jin-Han;Kim, Bo-Mi;Choi, Mi-Sun;Roh, Hye-Jin;Park, Mi-Jung
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.43 no.6
    • /
    • pp.629-636
    • /
    • 2010
  • A simple, rapid method for determining amoxicillin (AMO) and ampicillin (AMP) in aquatic products (flatfish, salmon, shrimp, tilapia, and yellow croaker) was evaluated. For quantification, the AMO and AMP ions at m/z 348.9 and 105.9, respectively, were selected. The limit of detection (LOD) and limit of quantification (LOQ) for detecting AMO were 0.09 and $0.25\;{\mu}g/L$, respectively. The respective values for AMP were 0.02 and $0.05\;{\mu}g/L$. After $100\;{\mu}g/L$ AMO treatment, the level decreased 10% after 7 days at $5^{\circ}C$, while it decreased 20% at $25^{\circ}C$. After 7 days, 94.9.100% of $100\;{\mu}g/L$ AMP remained after storage at $5^{\circ}C$, while 62.3.100% remained after storage at $25^{\circ}C$. Using the food code method, the recovery of AMO ranged from 64.1.92.0% and that of AMP from 44.8.86.2%. With a protein centrifugation method, the recovery of AMO ranged from 39.8.87.9% and that of AMP from 78.0.98.1%. With liquid-liquid extraction, the recovery of AMO ranged from 36.5.88.3% and that of AMP from 31.8.75.1%.

The analysis of pharmaceuticals in drinking water by HPLC/ESI-MS/MS (HPLC/ESI-MS/MS에 의한 먹는물(정수) 중 의약물질의 분석)

  • Park, Mi-Sun;Kim, Byung-Joo;Myung, Seung-Woon
    • Analytical Science and Technology
    • /
    • v.23 no.5
    • /
    • pp.457-464
    • /
    • 2010
  • The analytical method of four pharmaceuticals (virginiamycin, erythromycin, tylosin and cimetidine) in drinking water was developed. Effective simultaneous sample clean-up and extraction by solid-phase extraction (SPE) using HLB cartridge prior to LC/ESI-MS/MS analysis were performed. A linear correlation observed in the calibration curves for drinking water in the range of 0.01~2.0 ng/mL showed above $r^2$=0.995. Absolute recovery was in the range of 64.7~118.1% (except cimetidine (37.7~48.1%)). Limit of detection (LOD) and limit of quantitation (LOQ) in spiked drinking water matrix were in the range of 1.6~74.8 pg/mL and 5.5~249.7 pg/mL, respectively. The established method can be used to determine low pg/mL levels of pharmaceuticals in the drinking water.

Simultaneous analysis of glucocorticoids in bovine muscle and liver by LC-MS/MS (LC-MS/MS를 이용한 소의 근육과 간 중에 잔류하는 glucocorticoids 동시 분석)

  • Shin, Sang-Eun;Cho, Hyun-Woo;Myung, Seung-Woon
    • Analytical Science and Technology
    • /
    • v.23 no.4
    • /
    • pp.405-413
    • /
    • 2010
  • A new method for the simultaneous determination of six glucocorticoids (betamethasone, dexamethasone, prednisone, prednisolone, methylprednisolone, and flumethasone) in meats (bovine muscle, bovine liver) were established. Samples were effectively extracted using C18 cartridge with ethylacetate. Chromatographic separation was achieved using C18 column and negative electrospray ionization mass spectrometry was performed in the Multiple Reaction Monitoring mode for the effective quantitation and qualification of glucocorticoids. Acetonitrile and water (0.1% formic acid) were used as mobile phase and additive for effective electrospray ionization, and gave good chromatographic separation and mass spectrometric sensitivity. The limit of detection (LODs) and the limit of quantitation (LOQs) in spiked blank samples depending on types of matrix and pharmaceuticals were ranged from 0.2 to $1.0\;{\mu}g$/kg and 0.8 to $3.4\;{\mu}g$/kg, respectively. And the recoveries were between 89.5 to 119.6%. The established method showed good recoveries, accuracies, precisions and fast sample preparation and it will be applied to assay of glucocorticoids residues in meat.

Study on Diminution of Pesticide Residues in Citrus Fruits by γ-Irradiation (감마선 조사에 의한 감귤의 잔류농약 저감화 연구)

  • Yang, Hee Sun;Park, Yong Dae;Jin, Chang Hyun;Choi, Dae Seong;Jeong, Il Yun
    • Journal of Radiation Industry
    • /
    • v.3 no.1
    • /
    • pp.19-24
    • /
    • 2009
  • The citrus fruits were irradiated at different doses (25~200 kGy) to remove pesticides such as diuron, dichlorbenil, trifluralin, dimetoate, chlorothalonil, fenitrothion, bromacil, phenthoate and norflurazon, and the rates of degradation were detected by using gas chromatography electron capture detector (GC-ECD). The limit of detection (LOD) was in the range of 0.007~0.105 ppm. The limit of quantification (LOQ) was in the range of 0.024~0.352 ppm, and the recoveries of 9 pesticides were in the range of 71.5~106.5%. The results demonstrated that the ${\gamma}$-irradiation was effective method to remove pesticides such as diuron, dichlorbenil, trifluralin, dimetoate, chlorothalonil, fenitrothion, and norflurazon. However, the bromacil and phenthoate showed lower removal rates in the rate of 40.5 and 54.8%, respectively, at 200 kGy irradiation.

HPLC를 이용한 축육(Pork Muscle)내의 Dihydrostreptomycin 검출법

  • Choe, Ji-Hyeon;Han, Eun-Yeong;Park, Jin-Gwan;Lee, Su-Yeon;Choe, Dong-Mi;Sin, Ho-Cheol;Lee, Chi-Ho
    • Proceedings of the Korean Society for Food Science of Animal Resources Conference
    • /
    • 2005.10a
    • /
    • pp.196-203
    • /
    • 2005
  • 축산식품 고기내의 잔류항생물질을 신속하고 간편하고 정확하게 분석하기 위한 시험법 개발 을 목적으로 하였다. 축산식품내의 일반적인 잔류항생물질에 대한 지금까지의 분석법으로는 Bioassay법, TLC법, ELISA법, GC법 및 HPLC법 등이 있지만 Streptomycin/Dihydro streptomycin, Neomycin에 대한 HPLC법은 거의 확립되어 있지 않은 실정이다. 우리나라의 공인 검사법으로는 Bioassay법 및 HPLC법 등이 있지만 그러나 지금까지의 방법으로는 검출감도가 낮은 것이 큰 문제점으로 되어 왔다. 본 연구에서는 DST에 대한 HPLC법에 대한 보고한 P. Edder 방법 중에 clean-up과정 및 이동상 조건을 대폭 수정하여 DST의 분리 및 검출감도를 낮추려고 시도하였다. 본 연구에 사용된 유도체화 장치 Post-Column Derivatization Instrument PCX 5100 (Pickering Laboratories, Inc.)의 컬럼온도는 $40^{\circ}C$, 오븐온도 $55^{\circ}C$, reagent 유속 0.6ml/min mobile phase 유속 0.8ml/min으로 검출기는 형광검출기를 이용하여 DST 검출에 대해 만족할 만한 결과를 얻었다. 이때의 분석소요시간은 약 15분이었다. 표준시료 DST의 검량선은 넓은 농도범위(0.02${\sim}$1.0ppm)에서 양호한 직선성을 나타냈다. 본 시험법에 의한 검출한계는 limit of detection (LOD)은 0.02ppm이었으며, 적어도 고기에서의 MRL이 0.6ppm임을 감안하면 DST를 정량적으로 정도 좋게 측정할 수 있다는 것을 확인했다. 상기의 조건하에서 실제시료인 고기에 표준 DST를 1ppm을 spiking한 후 SPE상에서 SCX(Strong cation exchange column)을 통한 clean-up과정을 거친 후의 DST의 limit of quantification(LOQ)는 약 0.47ppm이었으며, 이에 대한 회수율은 97.7%(n= 8)를 나타냈다. 실제 codex에서 권장한 고기의 MRL이 0.6ppm인 점을 감안하면 codex 권고치에 도달할 수 있는 것으로 판단되었다. 따라서 본 연구에서 개발된 시험법은 지금까지 국내적으로 DST에 대한 시험법이 확립되어 있지 않은 것으로 이와 아울러 간편한 parallux와 병용해 DST에 대한 정량 및 정성 분석을 유도체화 장치 및 형광검출기를 이용해 잔류항생물질 DST에 대한 분석시험법의 개발이 가능하다고 여겨진다.

  • PDF

HPLC를 이용한 우유 중에 잔류 항생물질(Streptomycin)의 정량 분석

  • Byeon, Jang-Won;Park, Hwan-Seok;Hong, Go-Eun;Hong, Mu-Gi;Park, Gwan-Ha;Lee, Chi-Ho
    • Proceedings of the Korean Society for Food Science of Animal Resources Conference
    • /
    • 2005.10a
    • /
    • pp.310-316
    • /
    • 2005
  • 축산식품(우유)내의 잔류항생물질을 신속하고 간편하고 정확하게 분석하기 위한 시험법 개발을 목적으로 하였다. 축산식품내의 일반적인 잔류항생물질에 대한 지금까지의 분석법으로는 Bioassay법, TLC법, ELISA법, GC법 및 HPLC법 등이 있지만 Streptomycin/dihydrostreptomycin, neomycin에 대한 HPLC법은 거의 확립되어 있지 않은 실정이다. 우리나라의 공인 검사법으로는 Bioassay법 및 HPLC법등이 있지만 그러나 지금까지의 방법으로는 검출감도가 낮은 것이 큰 문제점으로 되어 왔다. 본 연구에서는 STP에 대한 HPLC법에 대한 보고한 Edder 방법 중에 clean-up 과정 및 이동상 조건을 대폭 수정하여 STP의 분리 및 검출감도를 낮추려고 시도하였다. 본 연구에 사용된 유도체화 장치 Post-Column Derivatization Instrument PCX 5100 (Pickering La-boratories, Inc.)의 컬럼 온도는 $40^{\circ}C$, 오븐온도 $55^{\circ}C$, 유도체화 용매 유속 0.6ml/min 이동상 유속 0.8ml/min으로 검출기는 형광검출기를 이용하여 STP 검출에 대해 만족할 만한 결과를 얻었다. 이때의 분석소요시간은 약 15분이었다. 표준시료 STP의 검량선은 넓은 농도범위(0.02${\sim}$1.0ppm)에서 양호한 직선성을 나타냈다. 본 시험법에 의한 검출한계는 limit of detection(LOD)은 0.02ppm이었으며, 적어도 우유에서의 MRL이 0.6ppm임을 감안하면 STP를 정량적으로 정도 좋게 측정할 수 있다는 것을 확인했다. 상기의 조건하에서 실제시료인 우유에 표준 STP를 0.5ppm을 spiking한 후 SPE상에서 SCX(Strong cation exchange column)을 통한 clean-up과정을 거친 후의 STP의 limit of quantification(LOQ)는 약 0.44ppm이었으며, 이에 대한 회수율은 89.7${\pm}$2.3%(n=6)를 나타냈다. 실제 CODEX에서 권장한 우유의 MRL이 0.6ppm인 점을 감안하면 CODEX권고치에 도달할 수 있는 것으로 판단되었다. 따라서 본 연구에서 개발 된 시험법은 지금까지 국내적으로 STP에 대한 시험법이 확립되어 있지 않은 것으로 이와 아울러 간편한 parallux와 병용해 STP에 대한 정량 및 정성 분석을 유도체화 장치 및 형광검출기를 이용해 잔류항생물질 STP에 대한 분석시험법을 개발하였다.

  • PDF

Simultaneous Analysis of Cold Medicine Component by High-Performance Liquid Chromatography(HPLC) (고성능 액체크로마토그래피(HPLC)를 이용한 Cold Medicine 성분의 동시 분석)

  • Wonju Lee;Seung-Tae Choi;Keun-Sik Shin;Jin-Young Park;Jae-Ho Sim
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.6
    • /
    • pp.867-873
    • /
    • 2023
  • In this study, for the purpose of standardized quality control of a cold medicine, we simultaneous analyzed four main chemical components of a cold medicine: acetaminophen, caffeine, methyl paraben, and propyl paraben. The sample was subjected to quantitative analysis using high performance liquid chromatography (HPLC), after pretreatment of four components. The experiment was carried out by using Isocratic elution at wavelength of 270nm. Acetonitrile and water (H2O) were used as a mobile phase at a flow rate of 1.0mL/min in a commercial C18 reversed-phase column. A volume of 10uL cold medicine were injected into the column with column oven temperature at 35℃. As a result of the experiment, the values of Resolution were 4.983, 1.596, 5.519, and 1.678 respectively-well over Rs >1.5, which indicates that the separation of four components were efficient. In addition, value of symmetry factor of the components was 1.056, 1.069, 1.032, and 1.133 respectively, to show its symmetrical stability. The calibration curve of all four components exhibits good linearity with R2 >0.9995 to 0.9999. Furthermore, the limit of detection(LOD) were between 0.0118 to 1.5973 mg/mL, while the limit of quantification (LOQ) were between 0.0353 to 4.7919 ㎍/mL with the recovery rate of 79.6% ~ 120.5%. The results of this study showed an efficient quality evaluation of a simultaneous analysis method for cold medicine components.

A Research on the Residual Pesticide Content of Dried Agricultural Products from Ulsan (울산지역 건조농산물 가공품의 잔류농약 분석)

  • Kim, Dae-Kyo;Kim, Seon-Hwa;Kim, Su-Hui;Choi, Jae-Seon;Kim, Hui-jeong;Kim, Young-Min
    • Journal of Food Hygiene and Safety
    • /
    • v.37 no.4
    • /
    • pp.238-248
    • /
    • 2022
  • This study was conducted to evaluate the safety of 208 types of residue pesticides on 150 dried agricultural products in Ulsan. The pesticide residues were detected using GC-MS/MS, LC-MS/MS, GC/ECD, GC/NPD, and LC/PDA. The detection rate was 19.3% (29 of 150 samples), and 28 types of pesticides were detected. Two of the 29 pesticide residues exceeded the maximum residue limit (MRL). Difenoconazole was detected in Ulleungdo aster, and chlorothalonil and chlorpyrifos were detected in chili pepper leaves. In the vegetable group, the frequency of pesticide residues was found to be the highest in dried leafy vegetables, followed by dried fruiting vegetables other than cucurbit vegetables, and then dried stalk and stem vegetables. The pesticide types detected in the commercial dried agricultural products were fungicide (60%), insecticide (23.8%), and acaricide (16.3%). In the validation study, the values of limit of detection (LOD), limit of quantitation (LOQ), coefficient of determination (R2), and recovery rate were in the range of 0.0001-0.0409 mg/kg, 0.0003-0.1241 mg/kg, 0.994-0.999, and 81.58-116.79%, respectively. The ratio of estimated daily intake (EDI)/acceptable daily intake (ADI) was 0.00002-0.31395%.