• Title/Summary/Keyword: Limit diode

Search Result 90, Processing Time 0.022 seconds

Detection of Methane and Ethane by Continuous-Wave Cavity Ring-Down Spectroscopy Near 1.67 μm

  • Oh, Myoung-Kyu;Lee, Yong-Hoon;Choi, Sung-Chul;Ko, Do-Kyeong;Lee, Jong-Min
    • Journal of the Optical Society of Korea
    • /
    • v.12 no.1
    • /
    • pp.1-6
    • /
    • 2008
  • We report the simple detection method of the small hydrocarbons, methane and ethane, by continuous-wave cavity ring-down spectroscopy near 1.67 ${\mu}m$ using an external cavity diode laser. The absorption lines of methane between 6002.48 $cm^{-1}$ and 6003.37 $cm^{-1}$ and ethane between 5955.65 $cm^{-1}$ and 5956.4 $cm^{-1}$ have been resolved and employed for the gas detection. The largest absorption cross sections were found to be 6.5$\times10^{-20}cm^2$ and 7.4$\times10^{-21}cm^2$ for methane and ethane, respectively, in each spectral range. The minimum detectable absorption limit of our spectrometer was 4.8${\times}10^{-9}cm^{-1}$/$\sqrt{Hz}$, which corresponds to the detection limits of 3 ppb/$\sqrt{Hz}$ and 27 ppb/$\sqrt{Hz}$ for methane and ethane, respectively. The near-IR continuous-wave cavity ring-down spectroscopic detection method of the small hydrocarbons can be applied for medical diagnosis and environmental monitoring as a fast and convenient method.

Bridgeless High Efficiency ZVZCS Power Factor Correction Circuit for PDP Power Module (PDP 파워 모듈을 위한 브리지 없는 고효율 ZVZCS 역률개선회로)

  • Ryu Byung-Gyu;Moon Gun-Woo;Cho Kyu-Min
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.3
    • /
    • pp.226-232
    • /
    • 2005
  • Recently, many nation have released standard such as IEC 61000-3-2 and IEEE 59, which impose a limit on the harmonic current drawn by equipment connected to AC line in order to prevent the distortion of an AC Line. Therefore, Plasma Display Panel(PDP) which is highlightened in digital display device also has the Power Factor Correction(PFC) circuit to meet the harmonic requirements. In PDP power module, the conventional boost converter is usually used for the PFC circuit. However, it comes serious thermal problem on it's bridge diode due to heat of PDP, and therefore the system stability is not guaranteed. In this paper, the bridgeless boost converter, which is used for PFC circuit of the PDP power module, is designed and verified the possibility of the application In a practical product in a view of efficiency, component count, temperature and etc.

Solitin Pulse Generation with Mode-Locked Erbium-Doped Fiber Laser Using Nonlinear Amplifying Loop Mirror (Nonlinear Amplifying Loop Mirror를 사용하여 모우드 록킹된 Erbium 첨가 광섬유 레이저에서 발생하는 솔리톤 펄스)

  • 박희갑;임경아
    • Korean Journal of Optics and Photonics
    • /
    • v.6 no.2
    • /
    • pp.142-147
    • /
    • 1995
  • Soliton pulse outputs are generated with figure '8' type erbium-doped fiber laser mode-locked by using a fiber loop mirror. The fiber loop mirror consists of an erbium-doped fiber amplifier at the one end of the loop, and 504 m-long dispersion-shifted fiber as a nonlinear medium. By pumping with a $1.48{\mu}m$ wavelength laser diode and adjusting the polarization controllers inside the loop, soliton pulses are generated with 1574 nm center wavelength and 1.2 nm linewidth. The soliton pulses are found randomly spaced within the fundamental period corresponding to cavity round trip time. The autocorrelation trace shows that the pulse width is 2.4 ps, which is in good agreement with the theoretical prediction. The pulsewidth- bandwidth product is found to be 0.348 which means that the pulses are nearly transform-limited.imited.

  • PDF

A Biosensor for the Rapid Detection of the Fungicide Iprovalicarb Residuess (살균제 Iprovalicarb 잔류물의 신속한 검출을 위한 바이오센서)

  • Cho, Han-Keun;Kim, Woon-Ho;Kyung, Kee-Sung;Lee, Eun-Young
    • Journal of Biosystems Engineering
    • /
    • v.32 no.6
    • /
    • pp.440-447
    • /
    • 2007
  • In this study, a biosensor was developed using an enzyme-linked immunosorbent assay (ELISA) to rapidly measure the fungicide iprovalicarb residues in agricultural products. The biosensor was designed to include micro-pumps and solenoid valves for fluid transport, a spectrophotometer cuvet as a reaction chamber, a photodiode with a light-emitting diode for optical density measurement, and a control microcomputer to implement assay. The rate of change in optical density of the cuvet was read as final signal output. Micro-pumps were evaluated to investigate their delivery capability, the highest values of the error and the coefficient of variation were 4.3% and 4.6% respectively. As the incubation period was reduced from 15 minutes to 11 minutes to shorten the total processing time, the sensor sensitivity was decreased as the antibody dilution ratio was reduced to a half. The maximum usable period of the coated cuvet was found to be two days with 1% error limit. To predict the concentration of the iprovalicarb residue in agricultural products, a linear calibration model was obtained with r-square values of 0.992 for potato and 0.985 for onion. In validation test for the samples of potatoes and onions against the high performance liquid chromatography, very high correlation values were obtained as 0.996 and 0.993 respectively. Using the cuvet immobilized with antigen, it took 21-minutes for the biosensor to complete the measuring process of the iprovalicarb residues.

Study on Scalable Video Coding Signals Transmission Scheme using LED-ID System (LED-ID 시스템을 이용한 SVC 신호의 전송 기법에 관한 연구)

  • Lee, Kyu-Jin;Cha, Dong-Ho;Hwang, Sun-Ha;Lee, Kye-San
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.10B
    • /
    • pp.1258-1267
    • /
    • 2011
  • In this paper, using the indoor LED-ID communication system have researched for how to transmit video signals. In LED-ID communications use the LEDs for lighting features at the same time communication is an effective way to implement. This proposed system using Visible light(RGB) as way to transmit signals, depends on the mixture RGB, which decided the color of light, moreover, each things determined their performance. However, if the video signal were fixed allocated RGB to transmit such as the original system, the importance of the each signals a different occur the limit on the quality of the video than SVC signals. In order to solve this problem in this paper, according to the RGB mixture ratios analyze the performance for the White LED, which analyzed based on allocating the SVC signal by transmitting to improve the quality of the video was about how researched.

Improvement in the Channel Capacity in Visible Light Emitting Diodes using Compressive Sensing (압축센싱기법을 이용한 가시광 무선링크 전송용량 증가기술 연구)

  • Jung, Eui-Suk;Lee, Yong-Tae;Han, Sang-Kook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.10
    • /
    • pp.6296-6302
    • /
    • 2014
  • A new technique, which can increase the channel bandwidth in an optical wireless orthogonal frequency division multiplexing (OFDM) link based on a light emitting diode (LED), is proposed. The technique uses adaptive sampling to convert an OFDM signal to a sparse waveform. In compressive sensing (CS), a sparse signal that is sampled below the Nyquist/Shannon limit can be reconstructed successively with sufficient measurements. The data rate of the proposed CS-based visible light communication (VLC)-OFDM link increases from 30.72 Mb/s to 51.2 Mb/s showing an error vector magnitude (EVM) of 31 % at the quadrature phase shift keying (QPSK) symbol.

Improvement of analytical method for pymetrozine in citrus fruits (감귤류 과일의 피메트로진 정량을 위한 분석법 개선)

  • Jeon, Jun-Ho;Chun, Su-Hyun;Kim, Min-Hyuk;Kim, Mi-Ok;Lee, Kwang-Won
    • Korean Journal of Food Science and Technology
    • /
    • v.51 no.4
    • /
    • pp.316-323
    • /
    • 2019
  • It is difficult to analyze pymetrozine in citrus fruits using the hydromatrix method because of its low efficiency of purification and overlap of matrix and pymetrozine peaks. Liquid-liquid extraction can analyze pymetrozine in citrus fruits using dichloromethane. Since low pH interferes with the extraction of pymetrozine, the extracts of citrus fruits were maintained over pH 7.0 by adding borax buffer and 1 N NaOH in the improved method. According to the improved method, citrus fruits (such as lemon, lime, orange, tangerine, and grapefruit) were extracted and purified for HPLC-photo diode array analysis. The results of validation were as follows: $4.360{\mu}g/kg$ of limit of detection, $14.533{\mu}g/kg$ of limit of quantitation, and 0.007 mg/kg of method quantitative limit. Citrus fruits spiked with pymetrozine showed a recovery range from 71.8 to 83.7% and a coefficient of variation below 6%. Thus, the improved method can efficiently analyze pymetrozine in citrus fruits.

Analysis and Survey for Contamination of Deoxynivalenol and Zearalenone in Feed by High Performance Liquid Chromatography (HPLC를 이용한 사료 중 Deoxynivalenol, Zearalenone의 분석과 오염도 조사)

  • Kim, Dong-Ho;Choi, Kyu-Il;Hong, Kyung-Suk;Kim, Hyun-Jung;Song, Yeong-Jin;Gang, Seung-Hun;Jang, Han-Sub;Cho, Hyun-Jung;Han, Gye-Su
    • Journal of Food Hygiene and Safety
    • /
    • v.26 no.3
    • /
    • pp.214-221
    • /
    • 2011
  • Deoxynivalenol (DON) and zearalenone (ZEN) are mainly contaminated mycotoxins in feeds. The study was carried out to analyze and survey the contamination of DON and ZEN in one hundred thirteen samples of feeds. After cleaning all samples with immunoaffinity column, the mycotoxins were analysed by using high performance liquid chromatography/fluorescence with diode array detector (HPLC/FLD with DAD). The average recoveries of DON were 88.76 and 95.40% at the levels of 200 and 1,000 ${\mu}g/kg$ and 87.09 and 98.40% of ZEN were recovered at the levels of 100 and 500 ${\mu}g/kg$, respectively. The limit of detection (LOD) were 6.0 and 3.0 ${\mu}g/kg$ for DON and ZEN, respectively. The average concentrations of DON were 372.1, 324.0 and 990.9 ${\mu}g/kg$ in chicken, pig and cattle feed, respectively. Those of ZEN were 76.1, 43.7 and 196.2 ${\mu}g/kg$ for them, individually.

Effect of Accelerated Aging on the Color Stability of Dual-Cured Self-Adhesive Resin Cements

  • Kim, Ah-Rang;Jeon, Yong-Chan;Jeong, Chang-Mo;Yun, Mi-Jung;Huh, Jung-Bo
    • Journal of Korean Dental Science
    • /
    • v.8 no.2
    • /
    • pp.49-56
    • /
    • 2015
  • Purpose: The effect of accelerated aging on color stability of various dual-cured self-adhesive resin cements were evaluated in this study. Materials and Methods: Color stability was examined using three different brands of dual-cured self-adhesive resin cements: G-CEM LinkAce (GC America), MaxCem Elite (Kerr), and PermaCem 2.0 (DMG) with the equivalent color shade. Each resin cement was filled with Teflon mold which has 6 mm diameter and 2 mm thickness. Each specimen was light cured for 20 seconds using light emitting diode (LED) light curing unit. In order to evaluate the effect of accelerated aging on color stability, color parameters (Commission Internationale de l'Eclairage, CIE $L^*$, $a^*$, $b^*$) and color differences (${\Delta}E^*$) were measured at three times: immediately, after 24 hours, and after thermocycling. The $L^*$, $a^*$, $b^*$ values were analyzed using Friedman test and ${\Delta}E^*$ values on the effect of 24 hours and accelerated aging were analyzed using t-test. These values were compared with the limit value of color difference (${\Delta}E^*=3.7$) for dental restoration. One-way ANOVA and Scheff's test (P<0.05) were performed to analyze each ${\Delta}E^*$ values between cements at each test period. Result: There was statistically significant difference in comparison of color specification ($L^*$, $a^*$, $b^*$) values after accelerated aging except $L^*$ value of G-CEM LinkAce (P<0.05). After 24 hours, color difference (${\Delta}E^*$) values were ranged from 2.47 to 3.48 and $L^*$ values decreased and $b^*$ values increased in all types of cement and MaxCem Elite had high color stability (P<0.05). After thermocycling, color change's tendency of cement was varied and color difference (${\Delta}E^*$) values were ranged from 0.82 to 2.87 and G-CEM LinkAce had high color stability (P<0.05). Conclusion: Color stability of dual-cured self-adhesive resin cements after accelerated aging was evaluated and statistically significant color changes occurred within clinically acceptable range.

Miniaturized Ground-Detection Sensor using a Geomagnetic Sensor for an Air-burst Munition Fuze (공중폭발탄용 신관에 적용 가능한 초소형 지자기 지면감지 센서)

  • LEE, HanJin
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.5
    • /
    • pp.97-105
    • /
    • 2017
  • An air-burst munition is limited in space, so there is a limit on the size of the fuze and the amount of ammunition. In order to increase a firepower to a target with limited ammunition, it is necessary to concentrate the firepower on the ground instead of the omnidirectional explosion after flying to the target. This paper explores the design and verification of a ground-detection sensor that detects the direction of the ground and determines the flight-distance of an air-burst munition using a single axis geomagnetic sensor. Prior to the design of the ground detection sensor, a geomagnetic sensor model mounted on the spinning air-burst munition is analyzed and a ground-detection algorithm by simplifying this model is designed. A high speed rotating device to simulate a rotation environment is designed and a geomagnetic sensor and a remote-recording system are fabricated to obtain geomagnetic data. The ground detection algorithm is verified by post-processing the acquired geomagnetic data. Taking miniaturization and low-power into consideration, the ground detection sensor is implemented with analog devices and the processor. The output signal of the ground detection sensor rotating at an arbitrary rotation speed of 200 Hz is connected to the LED (Light Emitting Diode) in the high speed rotating device and the ground detection sensor is verified using a high-speed camera.