• 제목/요약/키워드: Limit diode

검색결과 90건 처리시간 0.029초

Multimode Hybrid Control Strategy of LLC Resonant Converter in Applications with Wide Input Voltage Range

  • Li, Yan;Zhang, Kun;Yang, Shuaifei
    • Journal of Power Electronics
    • /
    • 제19권1호
    • /
    • pp.201-210
    • /
    • 2019
  • This paper proposes a multimode hybrid control strategy that can achieve zero-voltage switching of primary switches and zero-current switching of secondary rectifier diodes in a wide input voltage range for full-bridge LLC resonant converters. When the input voltage is lower than the rated voltage, the converter operates in Mode 1 through the variable-frequency control strategy. When the input voltage is higher than the rated voltage, the converter operates in Mode 2 through the VF and phase-shift control strategy until the switching frequency reaches the upper limit. Then, the converter operates in Mode 3 through the constant-frequency and phase-shift control strategy. The secondary-side diode current will operate in the discontinuous current mode in Modes 1 and 3, whereas it will operate in the boundary current mode in Mode 2. The current RMS value and conduction loss can be reduced in Mode 2. A detailed theoretical analysis of the operation principle, the voltage gain characteristics, and the realization method is presented in this paper. Finally, a 500 W prototype with 100-200 V input voltage and 40 V output voltage is built to verify the feasibility of the multimode hybrid control strategy.

유한요소해석을 이용한 LED 프레임의 열전달 특성에 관한 연구 (Study on Heat Dissipation Characteristics of LED Frames Using Finite Elements Method)

  • 손인수;강성중;전범식;안성진
    • 한국산업융합학회 논문집
    • /
    • 제23권6_2호
    • /
    • pp.935-941
    • /
    • 2020
  • In this study, the effect of different shapes on the heat dissipation characteristics of other porous frames on LED lighting frames was studied using finite element analysis. In addition, the heat transfer characteristics of LED frames were tested using a thermal imaging camera and the results of finite element analysis were compared to derive the optimal hole shape. According to the study, the heat dissipation effect was better for frames with hole compared to existing ones without holes. In particular, the heat dissipation characteristics test showed that for frames with holes, the rise time to the maximum temperature is fast and the maximum temperature is significantly lower. Also, we could see that the square and diamond shapes were smaller than the circular pores, but had a greater heat dissipation effect. Through this study, we have concluded that there is a limit to increasing the heat dissipation effect of the frame with a perforated shape, and it is necessary to conduct further research on the change in the shape of the frame in order to achieve a better heat dissipation effect in the future.

Optimization and validation of HPLC/DAD method for the determination of adenosine and cordycepin in cordyceps products

  • Sasikarn Panpraneecharoen;Tisorn Chatrakoon;Sompong Sansenya;Saowapa Chumanee
    • 분석과학
    • /
    • 제36권4호
    • /
    • pp.152-160
    • /
    • 2023
  • Adenosine and cordycepin are bioactive compounds with health benefits. Therefore, both substances are often used to assess the quality of Cordyceps products. Optimization and validation of the HPLC/DAD method for determining two nucleosides were studied. The samples were prepared using an ultrasound-assisted extraction (ultrasonic bath). The result was optimal conditions for aqueous extraction, an extraction time of 35 min, and an extraction temperature of 40 ℃. The Chromatographic separation was achieved using a reverse phase column (InfinityLab Poroshell 120 EC-C18, 4.6 × 250 mm, 2.7 ㎛) at 30 ℃ with a mobile phase gradient elution of water and methanol at a flow rate of 0.7 mL/min. The eluents were monitored via a diode array detector at 260 nm. Two nucleosides were separated by less than 12 min after injection. The developed method was found to be excellent linear (r2 > 0.9999), accurate (% recovery 95.34-98.51), and precise (% relative standard deviation < 2.0). The limit of detection (LOD) and quantification (LOQ) were 0.45 and 1.38 mg/mL for adenosine and 0.47 and 1.43 mg/mL for cordycepin, respectively. This method was satisfactory for simultaneously quantitating two nucleoside contents, which were used to evaluate Cordyceps products.

포도(Vitis vinifera L.) 중 Pyrimethanil 및 Methoxyfenozide의 생산단계 잔류허용기준 설정 (Establishment of Pre-Harvest Residue Limit for Pyrimethanil and Methoxyfenozide during Cultivation of grape)

  • 김지윤;우민지;허경진;마노하란 사라바난;권찬혁;허장현
    • 농약과학회지
    • /
    • 제19권2호
    • /
    • pp.81-87
    • /
    • 2015
  • 본 연구는 포도에 대한 pyrimethanil과 methoxyfenozide의 잔류량 변화를 측정하여 약제별 잔류특성을 파악하고, 잔류량 감소추이를 산출함으로써 생산단계 잔류허용기준(Pre-Harvest Residue Limit, PHRL) 설정을 위한 기초자료로 활용하고자 수행하였다. Pyrimethanil 및 methoxyfenozide 농약을 안전사용기준에 준하여 각각 포장 1, 포장 2 지역으로 나누어 기준량 처리하였으며, 약제처리 2시간 후를 0일차로 하여 0, 1, 2, 3, 5, 7, 10일차에 시료를 채취하여 분석하였다. 두 약제 모두 HPLC/DAD를 이용하여 분석하였으며, 분석정량한계(Method Limit of Quantitation, MLOQ)는 $0.01mg\;kg^{-1}$이었다. 분석결과, 분석법의 회수율은 80.6~102.5%이었으며, 표준편차는 모두 10% 미만이었다. 포도 중 각 농약에 대한 생물학적 반감기는 pyrimethanil의 경우 7.7일(포장 1), 7.4일(포장 2)이었으며, methoxyfenozide의 경우 5.1일(포장 1), 6.1일(포장 2)이었다. 잔류회귀감소식을 이용한 pyrimethanil과 methoxyfenozide의 생산단계 잔류허용기준은 각각 수확 10일 전 8.90과 $5.51mg\;kg^{-1}$으로 제안하였다.

Simultaneous Determination of B Group Vitamins in Supplemented Food Products by High Performance Liquid Chromatography-Diode Array Detection

  • Suh, Joon-Hyuk;Yang, Dong-Hyug;Lee, Byung-Kyu;Eom, Han-Young;Kim, Un-Yong;Kim, Jung-Hyun;Lee, Hye-Yeon;Han, Sang-Beom
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권8호
    • /
    • pp.2648-2656
    • /
    • 2011
  • A simple HPLC-DAD method was developed and validated to determine B group vitamin content (thiamine, riboflavin, nicotinamide, pantothenic acid, pyridoxine and folic acid) in supplemented food samples, i.e., infant formula, cereal, low-calorie food, a multi-vitamin pill and a vitamin drink. In this study, the most significant advantages were simultaneous determination of the six B group vitamins in various food matrices and a small number of sample treatment steps that required only an organic solvent, acetonitrile. Moreover, this method prevents reduction of column durability, because the mobile phase does not contain ion-pairing reagents. Analytes were separated on a Develosil RPAQUEOUS $C_{30}$ (4.6 mm ${\times}$ 250 mm, 5 ${\mu}M$ particle size) column with a gradient elution of acetonitrile and 20 mM phosphate buffer (pH 3.0) at a flow rate between 0.8 and 1.0 mL/min. Detection was performed at 275 nm, except for that of pantothenic acid (205 nm). The calibration curves for all six vitamins showed good linearity with correlation coefficients ($r^2$) higher than 0.995. The developed method was validated with respect to linearity, intra- and inter-day accuracy and precision, limit of quantification (LOQ), recovery and stability. The method showed good precision and accuracy, with intra- and inter-assay coefficients of variation less than 15% at all concentrations. The recovery was carried out according to the standard addition procedure, with yields ranging from 89.8 to 104.4%. This method was successfully applied to the determination of vitamin B groups in supplemented food products.

광중합형 레진으로 아말감 면에 브라켓 접착 시 전단결합강도 (Shear bond strength of orthodontic adhesive to amalgam surface using light-cured resin)

  • 조지영;이동렬;임용규
    • 대한치과교정학회지
    • /
    • 제35권6호
    • /
    • pp.443-450
    • /
    • 2005
  • 본 연구는 아말감 면에 광중합형 레진으로 교정용 브라켓을 접착시킬 경우, 광원의 차이(할로겐 광중합기와 light-emitting diode (LED) 광중합기)와 샌드블라스팅 표면처리 여부에 따른 접착제의 전단결합강도를 비교하고자 시행되었다. 발거된 소구치 30개를 대조군으로 이용하였으며 법랑질 표면을 산부식한 후 통상적인 방법으로 브라켓을 접착하였다. 60개의 다른 소구치에 아말감 충전을 하여 실험군으로 이용하였다. 두 군에서 할로겐 광중합기와 LED 광중합기를 이용하여 브라켓을 접착시키고 브라켓이 탈락될 때까지 힘을 가해 전단결합강도를 측정하였다. 실험 결과, 실험군의 전단결합강도는 약 3-5.5 MPa로 대조군(19MPa)보다 낮았다. 실험군에서 샌드블라스팅 표면처리를 한 경우, 할로겐 광중합기를 사용한 군이 LED 광중합기를 사용한 군보다 높은 전단결합강도를 보였으나 (P<0.05), 샌드블라스팅 표면처리를 하지 않은 경우에는 광원에 따라 전단결합강도에 차이를 보이지 않았다 (p > 0.05). 할로겐 광중합 군과 LED 광중합 군 모두에서 샌드블라스팅 여부에 따른 전단결합강도에 통계적으로 유의한 차이가 없었다 (p>005). 아말감 면에 광중합형 레진을 이용하여 브라켓을 접착할 경우 할로겐 광중합기와 LED 광중합기로 얻을 수 있는 접착제의 결합강도는 임상적으로 사용하기에는 낮게 나타나, 이의 증진 방법을 도모하기 위해 앞으로 더 많은 연구가 필요하리라 사료된다.

Inflammatory Effect of Light-Emitting Diodes Curing Light Irradiation on Raw264.7 Macrophage

  • Jeong, Moon-Jin;Kil, Ki-Sung;Lee, Myoung-Hwa;Lee, Seung-Yeon;Lee, Hye-Jin;Lim, Do-Seon;Jeong, Soon-Jeong
    • 치위생과학회지
    • /
    • 제19권2호
    • /
    • pp.133-140
    • /
    • 2019
  • Background: The light-emitting diode (LED) curing light used is presumed to be safe. However, the scientific basis for this is unclear, and the safety of LED curing light is still controversial. The purpose of this study was to investigate the effect of LED curing light irradiation according to the conditions applied for the polymerization of composite resins in dental clinic on the cell viability and inflammatory response in Raw264.7 macrophages and to confirm the stability of LED curing light. Methods: Cell viability and cell morphology of Raw264.7 macrophages treated with 100 ng/ml of lipopolysaccharide (LPS) or/and LED curing light with a wavelength of 440~490 nm for 20 seconds were confirmed by methylthiazolydiphenyl-tetrazolium bromide assay and microscopic observation. The production of nitric oxide (NO) and prostaglandin $E_2$ ($PGE_2$) was confirmed by NO assay and $PGE_2$ enzyme-linked immunosorbent assay kit. Expression of interleukin $(IL)-1{\beta}$ and tumor necrosis factor $(TNF)-{\alpha}$ in total RNA and protein was confirmed by reverse transcription polymerase chain reaction and Western blot analysis. Results: The LED curing light did not affect the viability and morphology of normal Raw264.7 cells but affected the cell viability and induced cytotoxicity in the inflammation-induced Raw264.7 cells by LPS. The irradiation of the LED curing light did not progress to the inflammatory state in the inflammation-induced Raw264.7 macrophage. However, LED curing light irradiation in normal Raw264.7 cells induced an increase in NO and $PGE_2$ production and mRNA and protein expression of $(IL)-1{\beta}$ and $(TNF)-{\alpha}$, indicating that it is possible to induce the inflammatory state. Conclusion: The irradiation of LED curing light in RAW264.7 macrophage may induce an excessive inflammatory reaction and damage oral tissues. Therefore, it is necessary to limit the long-term irradiation which is inappropriate when applying LED curing light in a dental clinic.

국내 정수장 먹는 물 중 폼알데히드 함유실태 조사 및 위해성 평가 연구 (Analysis and risk assessment of formaldehyde in water from water purification plant in korea)

  • 채효진;김현구;김승기;표희수;홍종기
    • 분석과학
    • /
    • 제22권5호
    • /
    • pp.386-394
    • /
    • 2009
  • 폼알데히드는 피혁 제조나 사진 건판, 폭약 등을 만들 때 이용되며, 정수장에서 오존 처리시 생성되는 소독 부산물이기도 하다. 노출시 안구 가려움증, 간지러움, 콧물, 코막힘, 두통 등의 증상이 나타나며 목이 건조해지거나 염증이 유발된다. 폼알데히드는 US. EPA에서 호흡으로 흡입할 경우 발암등급 B1으로 분류하는 발암성 물질이다. 본 연구에서는 폼알데히드의 분석을 위해 2,4-dinitrophenylhydrazine (DNPH) 유도체를 만든 후, 고체상 카트리지를 사용하여 추출하였고 High Performance Liquid Chromatography/Diode Array Detector (HPLC/DAD) 로 분석하였다. 검출 한계는 $3{\mu}g/L$이고, 72.3~109.1% (상대표준편차 2.9~11.5%)의 회수율을 보였다. 1998년도부터 2007년도까지 4대강 수계를 중심으로 채수하여 분석한 결과, 정수에서 검출 빈도 48.8% (630/1291), $5.15{\sim}101.9{\mu}g/L$의 농도로 검출되었다. 먹는물 음용시 비발암성을 고려한 95 percentile 전국 평균 위험지수는 $4.37{\times}10^{-3}$로, 이는 1 이하였으므로 안전한 수준으로 판단하였다.

Establishment of an Analytical Method for Azorubine, an Undesignated Food Colorant in Korea

  • Kim, Min-ji;Park, Ju-hee;Suh, Hee-Jae;Lee, Chan
    • 한국식품위생안전성학회지
    • /
    • 제31권5호
    • /
    • pp.311-318
    • /
    • 2016
  • 국내 미지정 색소인 azorubine에 대한 우리나라의 공인분석법을 설립하기 위해 제외국의 공인분석법들(유럽연합의 EFSA, 영국의 FSA, 우리나라의 식품의약품안전평가원)이 비교되었다. 재현된 HPLC 방법들 중 FSA의 분석법이 가장 우수한 분석 결과를 나타내어 azorubine분석법으로 최종 선정되었다. Azorubine 분석을 위한 위 세 기관의 전처리 방법은 모두 낮은 회수율을 나타내었다. 따라서 식품의약품안전평가원의 전처리법을 개선한 새로운 전처리 방법이 개발되었다. 최종 선정된 HPLC 분석법과 본 연구를 통해 개발된 새로운 식품 전처리법에 대한 분석법 밸리데이션을 실시하였다. 검증 실험에서 음료류에서 97~103%, 빵 및 과자류에서 95~101%, 기타 식품에서 93~102%의 회수율을 나타내었고, 실험실간 교차검증에서 -1.29~0.26의 z-score를 보여 신뢰할 수 있는 것으로 판단되었다. 이 결과로부터 본 연구에서 확립된 전처리법 및 분석법은 미지정 색소 azorubine이 사용된 식품검사에 활용될 수 있는 분석법으로 확인되었다.

새로운 생약복합제제(HPL-4)의 품질관리를 위한 분석법 개발 (Development of Analytical Method for Quality Control from New Herbal Medicine(HPL-4))

  • 김세건;서르마 디박 쿠마르;라미차네 라마칸타;이경희;한상미;정현주
    • 생약학회지
    • /
    • 제45권4호
    • /
    • pp.338-345
    • /
    • 2014
  • HPL-4 is a new herbal formulation developed for the treatment of osteoarthritis. In this study, we took HPL-4 to develop a method for simultaneous determination of nine marker compounds (protocatechuic acid, chlorogenic acid, liriodendrin, nodakenin, ${\beta}$-$\small{D}$-(3-O-sinapoyl)frucofuranosyl-${\alpha}$-$\small{D}$-(6-O-sinapoyl)glucopyranoside, quercitrin, 6-gingerol, decursin and decursinol angelate) present in the formulation. The analytes were separated by UPLC system consisting of diode array detector at 205 nm and RP-amide column, and solvent system of $ACN/0.1%H_3PO_4$. Analytical method was validated to evaluate its linearity, limit of detection (LOD), limit of quantification (LOQ), precision, and accuracy. All standards showed good linearity ($R^2$ >0.99) in the rage of $0.25-400.0{\mu}g/mL$. The LOD and LOQ were within the range of 0.021-0.148 and $0.070-0.448{\mu}g/mL$, respectively. Intra- and inter-day precision was less than RSD 4.0% and the accuracy was range from 92.00-104.81% with RSD<4.2%. The results suggest that the developed UPLC method is precise, accurate and effective, and could be applied for quality control of HPL-4 formulation.