• Title/Summary/Keyword: Limit Switch

Search Result 79, Processing Time 0.029 seconds

Output Characteristic Analysis of Outage and Phase Jump Generator for Microgrid (마이크로그리드용 순간정전 및 위상급변 발생기의 출력특성 해석)

  • Lee, Y.H.;Min, B.H.;Jung, J.H.;Nho, E.C.;Kim, I.D.;Chun, T.W.;Kim, H.G.
    • Proceedings of the KIPE Conference
    • /
    • 2008.10a
    • /
    • pp.106-108
    • /
    • 2008
  • This paper describes output characteristics analysis of outage and phase jump generator for microgrid. The outage and phase jump can be generated with 3-phase voltage disturbance generator. As soon as the outage occurs the STS(Solid Transfer Switch)s are switched off. At the beginning of the outage the PCS is required to limit the reverse current within the rated PCS output current. In case of phase jump the PCS output voltage phase should be adjusted. The generator output characteristics are analysed through simulation.

  • PDF

Design and Development of Large Electric Curtain Control System for Time Controlled (대형전동커튼 타임제어 시스템 설계 및 개발)

  • Cheng, Shuo;Chung, Yong Taek;Piao, Xiang Fan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.3
    • /
    • pp.1-6
    • /
    • 2019
  • The purpose of this paper is to design a curtain control system for centralized management of large curtains, which includes curtain structure, electric curtain controller, communication system, user interface and remote control. Curtain structure is designed to avoid using limit switch. The system is based on microprocessor, determined the stop position and complete running time of electric curtain through time control, and achieved remote control of curtain opening and closing through wired and wireless communication modes. By establishment of a mathematical model to calculate the inertia compensation time of the electric curtain, the electric curtain can be stopped ahead of time, and the curtain can be completely closed by the inertia. The result of test experiment of 32 electric curtain controllers shows the communication success rate reached 100%.

Characteristics of active optical ring network and performance evaluation in Bandwidth on Demand (능동형 광 링 네트워크의 특징 및 요구 대역폭에 따른 성능 분석)

  • Lee Sang-Wha;Song Hae-Sang
    • Journal of the Korea Society of Computer and Information
    • /
    • v.10 no.6 s.38
    • /
    • pp.209-218
    • /
    • 2005
  • In this paper, we present an Active Optical Network(AON) . The AON uses the Dense Wavelength Division Multiplexing(DWDM) from optical communication access network of ring type, and will be able to provide the smoothly service in the Bandwidth on Demand by using DWDM. It supports the connection of the multiple wavelength and the Sub-Carrier from the optical gigabit ethernet switch. The Wavelength Add Drop Multiplexer(WADM) extracts a specific wavelength, and composes a node of the ring network. The specific wavelength becomes demultiplexing in the Sub-Carrier and it is distributed in the user The active connection of optical gigabit ethernet switch where the distribution of access network is started and access terminal connection equipment is possible. By the BoD from the AON it compares the buffer size which changes, and it analyzes. Also the Time delay of bit compares with the throughput of server The limit of amount of time is decided. Consequently it will be able to realize the dynamic use protocol and an efficient algorithm of the network.

  • PDF

Emission Detection of Mercuric Ions in Aqueous Media Based-on Dehybridization of DNA Duplexes

  • Oh, Byul-Nim;Wu, Qiong;Cha, Mi-Sun;Kang, Hee-Kyung;Kim, Jin-Ah;Kim, Ka-Young;Rajkumar, Eswaran;Kim, Jin-Heung
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.9
    • /
    • pp.3223-3228
    • /
    • 2011
  • To quantify the presence of mercuric ions in aqueous solution, double-stranded DNA (dsDNA) of poly(dT) was employed using a light switch compound, $Ru(phen)_2(dppz)^{2+}$ (1) which is reported to intercalate into dsDNA of a right-handed B-form. Addition of mercuric ions induced the dehybridization of poly(dT)${\cdot}$poly(dA) duplexes to form a hairpin structure of poly(dT) at room temperature and the metal-to-ligand charge transfer emission derived from the intercalation of 1 was reduced due to the dehybridization of dsDNA. As the concentration of $Hg^{2+}$ was increased, the emission of 1 progressively decreased. This label-free emission method had a detection limit of 0.2 nM. Other metal ions, such as $K^+$, $Ag^+$, $Ca^{2+}$, $Mg^{2+}$, $Zn^{2+}$, $Mn^{2+}$, $Co^{2+}$, $Ni^{2+}$, $Cu^{2+}$, $Cd^{2+}$, $Cr^{3+}$, $Fe^{3+}$, had no significant effect on reducing emission. This emission method can differentiate matched and mismatched poly(dT) sequences based on the emission intensity of dsDNA.

Liquid Metal Enabled Thermo-Responsive Poly(N-isopropylacrylamide)Hydrogel for Reversible Electrical Switch (액체금속이 첨가된 온도 감응성 poly(N-isopropylacrylamide) 하이드로젤의 전기적 특성 변화 고찰)

  • Lim, Taehwan;Lee, Sohee;Yeo, Sang Young
    • Textile Coloration and Finishing
    • /
    • v.34 no.3
    • /
    • pp.207-216
    • /
    • 2022
  • Hydrogels have gained considerable attention in various fields due to their easily transformative ability by different stimulation. In addition, metal-based conductive additives can enable the hydrogels to be conductive with dimension change. Although the development of the additives offered enhanced electrical properties to the hydrogels, correspondingly enhanced mechanical properties may limit the volume and electrical properties switching after stimulation. Here we prepared poly(N-isopropylacrylamide) (PNIPAM) thermo-responsive hydrogel that has a 32℃ of low critical solution temperature and added liquid metal particles (LMPs) as conductive additives, possessing soft and stretchable benefits. The LMPs enabled PNIPAM (PNIPAM/LMPs) hydrogels to be constricted over 32℃ with a high volume switching ratio of 15.2 when deswelled. Once the LMPs are spontaneously oxidized in hydrogel culture, the LMPs can release gallium ions into the hydrogel nature. The released gallium ions and oxidized LMPs enhanced the modulus of the PNIPAM/LMPs hydrogel, triggering high mechanical stability during repeated swelling/deswelling behavior. Lastly, highly constricted PNIPAM/LMPs hydrogel provided a 5x106 of electrical switching after deswelling, and the switching ratio was closely maintained after repeated swelling/deswelling transformation. This study opens up opportunities for hydrogel use requiring thermo-responsive and high electrical switching fields.

Critical Conduction Mode BOOST Type Solar Array Regulator (임계모드 부스트형 태양전력 조절기)

  • Yang, JeongHwan;Ryu, SangBurm;Yun, SeokTeak
    • Journal of Satellite, Information and Communications
    • /
    • v.9 no.3
    • /
    • pp.86-90
    • /
    • 2014
  • A DC-DC Converter operates in CCM(Continuous Coundcution Mode), DCM(Discontinuous Conduction Mode), CRM(Critical Conduction Mode). The CRM is boundary between CCM and DCM. If a DC-DC converter is designed to operate in CRM, its inductor volume can decrease and power loss which caused by switch and diode can decrease. In this paper, the DC-DC converter which operates in CRM is applied to a solar array regulator(SAR) for the satellite. The switching frequency of the CRM boost SAR changes according to input and output condition. The switching frequency limit logic is applied to limit the maximum switching frequency. Meanwhile, the small signal transfer function of the CRM boost SAR is simple, so the controller design is also simple. In this paper, the small signal transfer function from control reference to solar array voltage is induced. And the voltage controller is designed based on the small signal transfer function. Finally, the CRM boost SAR is verified by simulation.

Investigation on the Nonideality of 12-Bit Sigma-Delta Modulator with a Signal Bandwidth of 1 MHz (1MHz 신호 대역폭출 갖는 12-비트 Sigma-Delta 변조기의 비이상성에 대한 조사)

  • 최경진;조성익;신홍규
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.26 no.11A
    • /
    • pp.1812-1819
    • /
    • 2001
  • In this paper, it investigated the permitted limit of the analog nonideality for the SOSOC Σ-Δ modulator design which is satisfied with 1 [MHz] signal bandwidth and 12-bit resolution in the OSR=25. Firstly, it get the SOSOC Σ-Δ modulator model and gain coefficient which is suitable in low voltage for the Σ-Δ modulator design which is satisfied with the specification in the supply voltage 3.3 [Vl. And it provided the performance prediction of the Σ-Δ modulator and the permitted limit of the nonideality by adding the performance degradation facts of the Σ-Δ modulator such as the finite gain of the amplifier, the SR, the closed-loop pole, the switch ON resistance and the capacitor mismatch to the ideal Σ-Δ modulator model. When designed the Σ-Δ modulator which is satisfied with the specification by the base above, it will be able to predict the performance of the Σ-Δ modulator and the guide for the specification of the circuit which composes the Σ-Δ modulator.

  • PDF

Comparison of Blood Lead Concentration Using Graphite Furnace Atomic Absorption Spectrometry (GF-AAs) and Inductively Coupled Plasma-mass Spectrometry (ICP-MS) (흑연로 원자 흡광 광도법과 유도 결합 플라즈마 질량 분석법을 이용한 혈중 납 농도 비교)

  • Kang, Min-Kyung;Kwon, Jung-Yeon;Kim, Byoung-Gwon;Lim, Hyoun-Ju;Seo, Jeong-Wook;Kim, Yu-Mi;Hong, Young-Seoub
    • Journal of Environmental Health Sciences
    • /
    • v.45 no.3
    • /
    • pp.258-266
    • /
    • 2019
  • Objectives: In this study, blood lead was analyzed using graphite furnace atomic absorption spectrometry (GF-AAs) and inductively coupled plasma mass spectrometry (ICP-MS). We tried to examine the difference and consistency of the analytical values and the applicability of the analytical method. Methods: We selected 57 people who agreed to participate in this study. After confirming the linearity of the calibration standard curves in GF-AAs and ICP-MS, the concentrations of lead in quality control material and samples were measured, and the degree of agreement was compared. Results: The detection limit of the ICP-MS was lower than that of GF-AAs. The coefficient of variation of reference materials was shown to be stable in the ICP-MS and GF-AAs. When the correspondence between the two equipments was verified by bias of the analysis values, a concordance was shown, and approximately 98% of the ideal reference lines were present within ${\pm}40%$ of the deflection. Conclusion: GF-AAs showed high sensitivity to single heavy metal analysis, but it took much time and showed higher detection limit than ICP-MS. Therefore, it would be considered necessary to switch to ICP-MS analysis method, considering that the level of lead exposure is gradually decreasing.

Magnetic Force-based Immunochip using Superparamagnetic Nanoparticles

  • Park, Je-Kyun;Kim, Kyu-Sung
    • 한국생물공학회:학술대회논문집
    • /
    • 2005.04a
    • /
    • pp.19-19
    • /
    • 2005
  • This paper reports a novel magnetic force-based microfluidic immunoassay using microbeads and magnetic nanoparticles. The magnetic force-based immunoassay was devised first and successfully applied to detect the rabbit IgG as the model analyte of microfluidic sandwich immunoassay. The microchannels were fabricated by poly(dimethysiloxane) (PDMS) molding processes and bonded on a slide glass by plasma treatment. At the part of the inlet, sample solution was hydrodynamically focused. The focused microbeads of sample solution were flowed through the 150 ${\mu}m$ width channel of outlet. However, when the microbeads are conjugated with the superparamagnetic nanoparticles under the applied magnetic fields, they will switch their flow path and flow through the 95 ${\mu}m$ width channel of outlet. The movements of microbeads conjugated with magnetic nanoparticles were demonstrated by magnetic field $gradients.^{1)}$ High magnetic field gradients using micro electromagnets could be applied to this detection method for high sensitivity and lower detection limit. In addition, the multiplexed $immunoassay^{2)}$ using an encoded microbead which is immobilized with a certain antibody could be possible using this detection principle.

  • PDF

Noninvasive Brain Stimulation Using a Modulated Microwave Signal

  • Seo, Taeyoon;Oh, Seongwoog;Jung, Dahee;Huh, Yeowool;Cho, Jeiwon;Kwon, Youngwoo
    • Journal of electromagnetic engineering and science
    • /
    • v.18 no.1
    • /
    • pp.70-72
    • /
    • 2018
  • We propose a microwave signal generation system for brain stimulation. The existing brain stimulation system uses a signal of several tens of kHz, and the magnetic field distribution is wide. Microwave is used to locally limit the distribution of the electromagnetic field and to change the action potential of the cell with less power. The switch modulates the microwave signal to obtain a pulse envelope. The action potential of the cell can be controlled to the excitation/inhibition state by adjusting the repetition frequency. These results are confirmed by measuring the cell potential of the mouse brain.