• Title/Summary/Keyword: Limit Switch

Search Result 79, Processing Time 0.028 seconds

Development of the Limit Switch Box for a Ship and Its Performance Evaluation against Salt Water

  • Lee, Seung-Heui;Go, Seok-Jo;Lee, Min-Cheol;Kim, Chang-Dong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1334-1338
    • /
    • 2005
  • A limit switch box is used for an indicator of a valve actuator. This device indicates an opening and closing of a valve or a throttle in the valve actuator. In a ship, equipments require safety and robustness because of a rough environment and a specific condition during a voyage. However, the limit switch box has been used in an indoor environment generally. This study developed a new limit switch box which can be used at an outdoor environment. This study designed the new limit switch box. The housing of the limit switch box was made by an aluminum die cast method with surface painting after anodizing or chromate coating. In order to evaluate the endurance of the housing, the endurance tests against salt water have been conducted. Experiment results showed that the proposed device provides a reliable performance against salt water.

  • PDF

A Study on the Development of the Limit Switch Box for Corrosion Protection (방식형 리미트 스위치 박스의 개발에 관한 연구)

  • Lee S.H.;Go S.J.;Lee M.C.;Kim C.D.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.836-839
    • /
    • 2005
  • A limit switch box is used for a indicator of a valve actuator. This device indicates an opening and closing of a valve or throttle in a valve actuator. In a ship, equipments are required safety and robustness because of a rough environment and a specific condition during a voyage. However, the limit switch box is used in an indoor environment generally. In order to evaluate the endurance of the limit switch box used in an indoor environment, the endurance tests against salt water have been conducted. Experiment results showed that the limit switch box was corroded severely. Thus, this study developed a new limit switch box which can be used at an outdoor environment. The housing of the developed limit switch box was made by an stainless steel to prevent corrosion.

  • PDF

A Study on the Design of the Limit Switch Box for a Ship (선박용 리미트 스위치 박스의 설계에 관한 연구)

  • Lee, Seung-Heui;Go, Seok-Jo;Lee, Min-Cheol;Kim, Hae-Su;Kim, Chang-Dong
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.899-903
    • /
    • 2004
  • A limit switch box is used for a indicator of a valve actuator. This device indicates an opening and closing of a valve or throttle in a valve actuator. In ship, equipments are required safe and robust because of a rough environment and a specific condition during a voyage. However, the limit switch box is used in an indoor environment generally. Thus, a new limit switch box must be developed which can be used at an outdoor environment. This study designed the limit switch box. The housing of the limit switch box was made by an aluminium die cast method with surface painting after anodizing or chromate coating. In order to evaluate the endurance of the housing, the endurance tests against salt water have been conducted. Experiment results showed that the proposed device provides a reliable performance against salt water.

  • PDF

Study on the Level Limit Switch Using a Self Made 1-3 type Ceramic/Polymer Composite Ultrasonic Transducer (1-3형 복합압전체 초음파 트랜스듀서를 사용한 레벨Limit스위치에 관한 연구)

  • Park, K.I.;Kim, H.G.;Shin, K.H.;SaGong, G.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.756-759
    • /
    • 2003
  • In this study, an ultrasonic transducer is fabricated with a 1-3 type composite resonator. Pulse-echo responses of an ultrasonic transducer are investigated in underwater with the designated water-levels. LED output signals of a level limit switch with changing a water level are obtained by using the currently developed self-made 1-3 type composite transducer and electric measuring unit. LED is turned on at above the up-limit level with increasing a water level, and LED is turned on at less than the down-limit level with decreasing a water level.

  • PDF

Pulse-echo Response of Piezoceramic-Polymer 1-3 Type Composite Transducer for a Level Limit Switch Applications (Level Limit스위치용 1-3형 복합압전체 트랜스듀서의 펄스-에코응답특성)

  • Choi, H.I.;Sohn, M.H.;Kim, H.K.;Park, K.I.;SaGong, G.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.224-228
    • /
    • 2002
  • In this study, the piezoelectric ceramics PZT powder was synthesized by the Wet-Dry combination method. Flexible 1-3 type composite specimens were fabricated with the piezoceramics PZT filler phase and Eccogel polymer matrix phase. This paper represents the pulse-echo response of the 1-3 type composite transducer to check it out to investigate a basic property regarding a level limit switch. The acoustic impedance of 1-3 type composite was improved than that of single phase PZT ceramics. The pulse-echo response of transducer fabricated with the self-made 1-3 type composites resonator was better than that of the solid PZT transducer.

  • PDF

Near Time Maximum Disturbance Design for Second Order Oscillator with Model Uncertainty (모델 불확실성을 갖는 이차 오실레이터에 대한 근사화된 최대 시간 교란 신호 설계)

  • You Kwan-Ho
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.52 no.4
    • /
    • pp.205-211
    • /
    • 2003
  • In this paper we propose a disturbance design method to test a system's stability. It is shown that the time maximum disturbance is represented in bang-bang and state feedback form. To maximize the time severity index, the value of disturbance is determined by the associated switch curve. The original switch curve is vulnerable to model uncertainties and takes much calculation time. We propose an improved method to approximate the original switch curve. This reduces the computational time and implements sufficiently to test the stable system. Simulation results show how the approximate switch curve can be used to stress a system by driving it to oscillation along the maximum limit cycle.

Two Stage Power Factor Correction (PFC) Converter With A Single PWM Controller

  • Park, Hang-Seok;Lee, Kyu-Chan;B.H. Cho
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.252-257
    • /
    • 1998
  • Two-stage power factor correction (PFC) converter with a single PWM controller for universal input voltage (90-264V) is proposed. It consists of a power factor pre-regulator cascaded by a DC/DC converter as in a conventional two-stage approach. However, a single PWM controller is used as in a single-stage, single-switch PFC approach. The switch in the PFC part is synchronized with the switch in the DC/DC converter with a fixed switching frequency. Employing an adaptive delay scheme the switch in the PFC part is controlled to limit the energy storage capacitor voltage within a designed range for the optimum efficiency, and to reduce input current harmonic distortion. The experimental results obtained on a 200W (5V/40A) prototype PFC converter are given to verify the effectiveness of the proposed control method.

  • PDF

Single Stage PFC Flyback Converter Using Top Switch (Top 스위치를 이용한 단일 전력단 역률개선 플라이백 컨버터)

  • Lim Chang Seob;Kwon Soon Kurl;Lee Hyun Woo;Kim Eun Soo
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.669-672
    • /
    • 2001
  • Generally, previous converter is divided into two categories to get high power factor and good output regulation. These two categories can be combined a category with a main switch. These converter is called Single Stage PFC Converter. This approach has good electrical characteristics of high power factor and fast output voltage regulation. The cost and size are important factor to design the converter in low power system. Even single stage can reduce the size and cost, but this approach needs to have additional circuit like control, PWM circuit. To improve these demerits, Top switch is one of good choice In reduce and size in low power single stage converter. Because it has the ability of current limit, thermal protection, oscillator, control circuit as well as a main switch ability.

  • PDF

A Study on the Level Limit Switch for Measuring Near-distance Variation with 1-3 Type Ceramic/Polymer Composite Ultrasonic Transducer (1-3형 복합압전체 초음파 트랜스듀서를 사용한 근접거리변동 측정용 레벨 Limit스위치에 관한 연구)

  • Kim, H.G.;Park, K.I.;Shin, K.H.;SaGong, G.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.08a
    • /
    • pp.103-106
    • /
    • 2003
  • In this study, an ultrasonic transducer is fabricated with 1-3 type composite resonators. Pulse-echo responses of an ultrasonic transducer are investigated in underwater dependent on the variable designated water-level. LED Output signals of a level limit with changing a water level is obtained by the 1-3 type self-made composite transducer and electric measuring unit. LED is turned on at above the up-limit level with increasing a water level, and LED is turned on at less than the down-limit level with decreasing a water level. There was good agreement between the virtual water level and output LED signal by using the self-made water-detecting system.

  • PDF

A Study on the Level Limit Switch for Underwater with 1-3 Type Ceramic/Polymer Composite Ultrasonic Transducer (1-3형 복합압전체 초음파 트랜스듀서를 사용한 수중용 레벨 Limit스위치에 관한 연구)

  • Kim, H.G.;Park, K.I.;Shin, K.H;SaGong, G.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.292-295
    • /
    • 2003
  • In this study, an ultrasonic transducer is fabricated with 1-3 type composite resonators. Pulse-echo responses of an ultrasonic transducer are investigated in underwater dependent on the variable designated water-level. LED Output signals of a level limit with changing a water level is obtained by the 1-3 type self-made composite transducer and electric measuring unit. LED is turned on at above the up-limit level with increasing a water level, and LED is turned on at less than the down-limit level with decreasing a water level. There was good agreement between the virtual level and output LED signal by using the self-made water-detecting system.

  • PDF