• Title/Summary/Keyword: Limit Environment

Search Result 1,608, Processing Time 0.029 seconds

BAT-AEL Calculation in Waste Incineration Facility (폐기물 소각시설 최적가용기법 연계배출수준 (BAT-AEL) 설정)

  • Shin, Sujeong;Park, Jae-Hong;Lee, DaeGyun;Kim, Dai-Gon;Bae, YeonJoung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.1
    • /
    • pp.144-155
    • /
    • 2018
  • As the public interest in environmental issues increased, the "Act On The Integrated Control Of Pollutant-Discharging Facility" was enacted. Through the integrated environmental pollution prevention act in which 19 industries with large environmental impacts are sequentially applied, pollutants can be managed in a medium-integrated manner and integrated permission of the business unit is possible and BAT can be applied to enable a scientific and proactive environmental management system. In addition, if the facility with BAT works normally, the pollutant emission is offered with the range of lower limit to upper limit. This study analyzed the overview of Best Available Techniques-Associated Emission Levels (BAT-AEL), and its setting procedure and method, and then suggested the BAT-AEL of a waste incineration facility. In comparative analysis on Emission Limit Values (ELVs) of EU, this study tries to propose improvement matters and development directions if the relevant standard is revised.

지하수의 라듐/라돈 동시측정을 위한 백그라운드 감마선 제어

  • Lee Gil-Yong;Yun Yun-Yeol;Jo Su-Yeong;Kim Yong-Je
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2005.04a
    • /
    • pp.308-311
    • /
    • 2005
  • [ $^{222}Rn\;and\;^{226}Ra$ ] in groundwater were determined simultaneously using a gamma-spectroscopy. A nitrogen flushing equipment has been used for elimination and stabilization of high and unstable background activity due to the radon and its progenies in counting shield and room. The aim of present work was to control the background activity for simultaneous measurement of radium$(^{226}Ra)$ and radon$(^{222}Rn)$ in groundwater using a gamma-spectrometry. Background activity was about 1.0dps and the standard deviation was about 50%, The background activity could be minimized using nitrogen flushing equipment in the range of 0.1 to 0.5 and the RSD was about 5% at the experimental condition. The detection limit of $^{222}Rn\;and\;^{226}Ra$ in groundwater was 0.5dps/L in the background control method. In most groundwater used in the work, radon activity was more than the detection limit. However, radium activity in some groundwater was less than the detection limit. If the low level radium in groundwater must be measured, preconcentration process such as concentration should be performed before measuring the groundwater.

  • PDF

A Study on Operating Limit Analysis for Small High-speed Boat (소형 고속정의 운항한계에 대한 연구)

  • BAE, Jun-Young
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.21 no.6
    • /
    • pp.784-789
    • /
    • 2015
  • It was carried out a review of operating limit analysis for small high-speed boat by author. In general, a review of ship's seakeeping performance is performed in the step of ship design, but this study was carried out in the state of completion of boat. Motion performance of Pitch, Vertical and Lateral acceleration and Slamming were satisfied in some encounter angle but deck wetness was not satisfied in all it does the analysis. As a result, sea state rather than the speed and encounter angle of vessel have a greater effect on the seakeeping performance of target vessel. It seems to be due to the size of the target ship.

Analysis of Carbonyl Compounds using DNPH Cartridge with LC-MS (DNPH cartridge/LC-MS 방법에 의한 카르보닐화합물 분석에 관한 연구)

  • Cho Deok-Hee;Song Il-Seok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.2
    • /
    • pp.201-208
    • /
    • 2006
  • Several carbonyl compounds are important because of their irritant and toxic properties, mutagenicity and carcinogenicity. Therefore, they are regulated in korean odor emission standard. In this study, atmospheric pressure ionization-mass spectrometry(API-MS) is used for the analysis of carbonyl compounds after derivatization with 2, 4-dinitrophenylhydrazine (DNPH) and liquid chromatographic separation. In the negative ion mode, the $[M-H]^-$ pseudomolecular ions are most abundant for the carbonyls. Analytical parameters such as linearity, repeatability and minimum detection limit were evaluated. The linearities ($r^2$) for carbonyls were $0.9977{\sim}0.9999$ when analyte concentration ranges from $25\;to\;250{\mu}g/L$(n=6). The relative standard deviations (%RSD) for carbonyls were $0.55{\sim}3.51%$ for concentration of $100{\mu}g/L$(n=5). The minimum detection limit (MDL) was $1.88{\mu}g/L$(0.27 ppb) for i-valeraldehyde. It was shown that LC-MS method has a great potential for carbonyl compounds analysis.

Decision Feedback Doppler Adaptive Band-Limit Algorithm for Maximum Doppler frequency Estimation (속도 추정 시 부가 잡음의 영향을 억제하기 위한 결정 궤환 적응형 대역 제한 방법에 대한 연구)

  • 박구현;한상철;류탁기;홍대식;강창언
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.11C
    • /
    • pp.1111-1117
    • /
    • 2003
  • The maximum Doppler frequency, or equivalently, the mobile speed is very useful information to optimize the performance of many wireless communication systems. However, the performance of a maximum Doppler frequency estimator is limited since it requires an estimate of the signal-to-noise ratio (SNR) of the channel environment. In this paper, the improved method for the maximum Doppler frequency estimations based on the decision feedback Doppler adaptive band-limit (DF-DABL) method is proposed. To reduce the effect of additive noise, the proposed algorithm uses a novel Doppler adaptive band-limit (DABL) technique. The distortion due to the additive noise is drastically removed by the proposed DF-DABL method. Especially, the DF-DABL method does not need any other channel information such as SNR.

Determination of Derived Release Limits by the Concentration Factor Method (농축인자법에 의한 유도방출 기준 설정)

  • Byung Woo Kim;Byeung Kyu Kim;Jeong Ho Lee
    • Nuclear Engineering and Technology
    • /
    • v.17 no.4
    • /
    • pp.267-278
    • /
    • 1985
  • Some kinds of methods have been applied to regulate the exposure doses by the radioactive effluents from nuclear power plants. The essential one is primary dose equivalent limit recommended by the ICRP. When the primary limit cannot be applied directly for regulation, there have been dose equivalent index in case of external exposure, or maximum permissible concentration, annual limit on intake, derived air concentration and maximum permissible body burden in case of internal exposure. But the derived limit is required from the viewpoint of discharge, for those values are inadequate to control discharge rate directly. This study was carried out to derive the release limit for the Wolsung nuclear power plant by the concentration factor method. This method is based on the assumption of steady state transfer between environment compartments.

  • PDF

Mornitoring of 1-hexene and 1-octene in Hygienic Polyethylene-based Packaging (폴리에틸렌계 위생용 용기포장재중의 1-hexen과 1-octene 조사)

  • Cho, Sung-Ja;Kim, Ae-Kyung;Kwak, Jae-Eun;Kim, Ji-Young;Kim, Si-Jung;Kum, Jin-Young;Kim, Il-Young;Kim, Jung-Hun;Chae, Young-Zoo
    • Journal of Food Hygiene and Safety
    • /
    • v.26 no.4
    • /
    • pp.383-387
    • /
    • 2011
  • The levels of migration of 1-hexene and 1-octene residues in PE (polyethylene) products were analyzed by Headspace gaschromatography (HSGC). A total of 21 samples were including lap, polyglove, zipper bag and ect. The samples were eluted with distilled water, 4% acetic acid, 20% ethanol and n-heptan. The limit of detection (LOD) was 0.06 mg/L ~ 0.30 mg/L and limit of quantitation (LOQ) was 0.21 mg/L ~ 1.01 mg/L, respectively. But because of the high volatile, n-heptan elution was not detected 1-hexene and 1-octene standard. 1-hexene and 1-octene were not detected in the sample which eluted with simulant at $60^{\circ}C$, 30min. Microwave for 1 minute also treated sample and direct heated at $100^{\circ}C$ without simulant were not detected.

Establishment of Pre-Harvest Residue Limit (PHRL) of Methoxyfenozide and Novaluron on Peaches (복숭아 중 Methoxyfenozide와 Novaluron의 생산단계 농약잔류허용기준 설정)

  • Cho, Kyung-Won;Park, Jae-Hun;Kim, Ji-Won;Yoon, Ji-Yeong;Moon, Hye-Ree;Lee, Kyu-Seung
    • The Korean Journal of Pesticide Science
    • /
    • v.17 no.1
    • /
    • pp.6-12
    • /
    • 2013
  • Methoxyfenozide and novaluron were sprayed with single and triple treatments separately on peach during cultivation period. Samples were collected over 14 days, 8 times in total (0, 2, 4, 6, 8, 10, 12, 14 days). Methoxyfenozide and novaluron were extracted with acetone and partitioned with dichloromethane, and analyzed by HPLC/DAD. Method Quantitation Limit (MQL) were both 0.005 mg/kg, average recoveries of methoxyfenozide at two fortification levels of 0.05 and 0.25 mg/kg were determined $92.7{\pm}2.9%$ and $102.8{\pm}3.1%$, and novaluron were $98.2{\pm}4.8%$ and $96.7{\pm}9.0%$, respectively. The biological half-life of methoxyfenozide was about 4.41 days at single treatment, and 4.24 days at triple treatments. The biological half-life of novaluron was about 14.81 days at single treatment, and 14.50 days at triple treatments. Dissipation of pesticides on peach was influenced by growth dilution effect. In case of application of methoxyfenozide and novaluron following guidelines on safe use of pesticides, the final residue level was predicted to be lower than Maximum Residue Limit (MRL).

Establishment of Pre-Harvest Residue Limit (PHRL) of Emamectin benzoate during Cultivation of Amaranth (생산단계 비름 중 Emamectin benzoate의 잔류허용기준 설정)

  • Kim, Kyung Jin;Kim, Da Som;Heo, Seong Jin;Ham, Hun Ju;Hur, Jang Hyun
    • The Korean Journal of Pesticide Science
    • /
    • v.17 no.2
    • /
    • pp.77-83
    • /
    • 2013
  • This study was performed to investigate pre-harvest residue limit (PHRL) in amaranth, to estimate biological half-life of emamectin benzoate and identify the characteristics of the residue. Pesticides of standard and double appplication rate, were sprayed once on amaranth at 0, 1, 2, 3, 5, 7, 10, 14 days before harvest. Amaranth sample was extracted with acetonitrile and partitioned with dichloromethane, and pesticide residues were determined with LC/MS/MS. The limit of detection of emamectin benzoate was 0.01 mg/kg. Recoveries of emamectin benzoate ($B_{1a}$, $B_{1b}$) at two fortification levels of 0.1 and 0.5 mg/kg, $B_{1a}$ were $93.3{\pm}0.7%$ and $93.2{\pm}7.7%$, $B_{1b}$ were $106.6{\pm}1.9%$ and $80.5{\pm}6.6%$, respectively. The biological half-lives of emamectin benzoate were about 2.0 days at standard application rate and 1.7 days at double application rate, respectively. The PHRL of emamectin benzoate were recommended as 0.84 mg/kg for 10 days before harvest.