• 제목/요약/키워드: Lignin admixture

검색결과 6건 처리시간 0.023초

고성능 혼화제를 이용한 시멘트의 $Cr^{6+}$ 용출특성 ($Cr^{6+}$ leaching property of cement using high performance lignin)

  • 박현;김경남
    • 한국결정성장학회지
    • /
    • 제19권3호
    • /
    • pp.135-143
    • /
    • 2009
  • $Cr^{6+}$의 고용화 가능성과 lignin계 혼화제의 성능을 조사하기 위하여 과잉의 $Cr^{6+}$을 첨가하여 KSLI, 미국 TCLP법, Soaking Procedure를 이용하여 각 기준에 따른 용출 특성을 조사하였다. 그 결과 lignin계 혼화제는 첨가에 따라 모르타르 강도 증진을 보였으며 용출 특성에 큰 변화는 없었다.

혼화제를 이용한 조강콘크리트 배합설계에 관한 연구 (A Study on the Mix Design of Early Strength Concrete using Admixture)

  • 박영신;남성우;박재명
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(II)
    • /
    • pp.69-72
    • /
    • 2005
  • In this study, it is contents to application on AE water reducing admixture for high early strength, which reduce to construction period for cost down in construction. In experiment result on the kinds of AE water reducing admixture for concrete strength promotion, when passed 60 minutes, while it was happened on lignin and naphthalene system about $30\∼35\%$ that loss related to slump, slump flow and air, but happened about $8\∼10\%$ on polycarboxylic system. And the result of compressive strength tests, when 32 hours passed in polycarboxylic system than lignin and naphthalene system, was showing an increase of 10$\%$. Accordingly, concrete properties was measured to condition change by the addition amount and curing temperature of polycarboxylic system. The required curing temperature to gain 5MPa of compressive strength, which is capable of side form stripping, must keep more than smallest 12. 5$^{circ}C$ when polycarboxylic system is used. As a result, AE water reducing admixture of polycarboxylic system may apply effectively to high early strength concrete

  • PDF

액체 밀도계 및 pH meter기를 이용한 감수제의 신속품질평가 가능성 분석 (Analysis of the Possibility of Rapid Quality Appraisal of Water-Reducing Agents Using the Liquid Densimeter and pH Meter)

  • 김민상;현승용;백철;조만기;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 춘계 학술논문 발표대회
    • /
    • pp.210-211
    • /
    • 2017
  • According to KS F 2560, water-reducing agents used when mixing concrete are to undergo quality evaluation testing slump, air contents, setting time, etc., when delivered from the admixture factory to the ready mixed concrete site. Yet in actual acceptance testing this could be substituted by the score report of the admixture company, in which a possibility of low reliability lies. Therefore this study sought to analyze whether by artificially changing the solid content rate of lignin- and naphthalene-based water-reducing agents and using a liquid densimeter evaluate the quality of the admixture. The results showed that the Type B liquid densimeter was most appropriate and 50cc the most appropriate capacity for the mass cylinder. Also, judging from the changes in density and pH according to the changes in solid content rate, it concludes that a rapid appraisal of the quality of lignin- and naphthalene-based water-reducing agents would be possible using a Type B liquid densimeter.

  • PDF

감수제의 고형분율 변화에 따른 모르타르의 기초적 특성 (Fundamental Characteristics of Mortar According to the Changes in the Solid Content Rate of the Water-Reducing Agent)

  • 김민상;이재진;현승용;김태우;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 춘계 학술논문 발표대회
    • /
    • pp.156-157
    • /
    • 2017
  • It is possible in the case of the chemical admixtures for concrete currently being used in actual work sites to omit quality evaluation and replace it with the scores of the admixture manufactures; this can create a problem of decline in reliability in quality on the work site. Therefore this study sought to analyze the degree of influence changes in the solid content rate of lignin- and naphthalene-based water-reducing agents have on the fundamental characteristics of cement mortar. The results showed that in fresh mortar, the flow and amount of air decreases with decrease in the solid content ratio. In hardened mortar, the condensation strength had hardly any effect on the use of lignin-based water-reducing agent, but naphthalene-based water-reducing agent increased with the decrease in the solid content ratio.

  • PDF

Lignosulfonic Acid계(系) 감수제(減水劑)가 모르터의 강도(强度)에 미치는 영향(影響) (The Influence of Admixture of Lignosulfonic Acid Type on the Strength of Mortar)

  • 김한영;김성완
    • 농업과학연구
    • /
    • 제12권1호
    • /
    • pp.75-85
    • /
    • 1985
  • 본(本) 연구(硏究)는 Lignosulfonic Acid계(系) 감수제(減水劑)를 첨가(添加)한 모르터의 유동성(流動性) 개선(改善)과 강도변화(强度變化)를 구명(究明)하고자 시행(施行)하였다. 1. Plastic 상태(狀態)에서 Pozzolith-84의 첨가량(添加量)을 늘리면 Flow가 증가(增加)하였다. 이는 Pozzolith-84의 첨가(添加) 시(時) 전기적(電氣的) 이중층(二重層)이 형성(形成)되어 시멘트 입자(粒子) 상호간(相互間)에 반발력(反撥力)이 생겨 분산(分散)된 것으로 이 분산작용(分散作用)은 술폰산기(酸基)의 계면활성작용(界面活性作用)에 기인(基因)되며, 시공성(施工性)이 개선(改善)됨에 따라 Precast 제품(製品) 생산(生産) 시(時) 비용절감(費用節減)의 효과(效果)가 있으며, 단위수량감소(單位水量減少)에 의(依)해 구조물(構造物)의 내구성(耐久性)이 개선(改善)된다. 2. 경화(硬化)된 상태(狀態)에서는 P/C가 0.2, 0.4%일 때 보통(普通)모르터의 강도(强度)보다 다소증가(多少增加)되었으며, P/C가 0.8% 이상(以上)일 때 보통(普通) 모르터의 강도(强度) 보다 감소(減少)된 것은 잔류(殘留) 술폰산(酸)($SO_3H$), 무수유산(無水硫酸)($SO_3$)의 화학반응(化學反應)에 의(依)한 것으로 생각된다. 3. 비중(比重)과 압축강도(壓縮强度) 분석(分析) 결과(結果) 고도(高度)의 유의성(有意性)이 있었으며 비중(比重)이 커짐에 따라 압축강도(壓縮强度)도 역시 증가(增加)되었고, 재령(材齡) 7일(日)과 28일(日)의 강도(强度) 분석(分析) 결과(結果) 고도(高度)의 유의성(有意性)이 있었으며, 재령(材齡) 7일(日)의 압축(壓縮) 강도(强度)가 클수록 인장(引張) 휩강도(强度)도 역시 크게 나타났다. 4. Pozzolith-84는 펄프공업(工業)의 폐기물(廢棄物)인 Lignosulfonic Acid Type이며 이를 실용화(實用化)하면 산업폐기물(産業廢棄物)의 활용(活用)에 유익(有益)하다고 생각된다.

  • PDF

혼화제 종류별로 제조된 콘크리트의 재 혼합 타설시 특성 분석 (Analysis of the Characteristics of Manufactured Concrete, according to the Type of Admixture used when Remixing and Placing it)

  • 류현기;신상용
    • 한국건축시공학회지
    • /
    • 제10권5호
    • /
    • pp.95-102
    • /
    • 2010
  • 최근 들어 경제성장과 산업기반 시설의 확충 등으로 인하여 타사의 레미콘을 종종 혼용 하는 경우가 있는데, 사용되는 혼화재료의 경우 제조회사별로 화학성분 및 첨가량의 차이가 있으므로 서로 다른 레미콘 제조회사의 콘크리트가 혼합되었을 시에 강도 저하 및 응결지연, 내구성 저하 등으로 인한 콘크리트의 성능 저하요인이 발생된다. 혼화제 종류별로 제조된 콘크리트의 재 혼합 타설시의 성능 분석을 한 결과로서 먼저 슬럼프는 모든 콘크리트에서 목표슬럼프 값을 만족하였으며, 공기량 역시 모든 콘크리트에서 목표 공기량을 만족 하였다. 블리딩량 및 블리딩률의 경우 전반적으로 유기산계와 같이 혼합된 콘크리트에서 높은 블리딩량을 나타내었다. 조기재령의 압축강도는 Plain의 나프탈린계에서 가장 큰 강도발현 경향을 나타내었고, 재 혼합 콘크리트에서는 5:5의 유기산계와 나프탈린계에서 가장 큰 압축 강도 발현 경향을 나타내었다. 표준재령의 경우 5:5의 재 혼합 콘크리트 중 나프탈린계+리그닌계를 혼합하였을 때 가장 큰 강도 발현 경향을 나타내었다. 인장강도 역시 압축강도와 유사한 경향을 나타내었다. 길이변화율은 전반적으로 Plain에 비하여 큰 건조수축 경향을 나타내었으며, 재 혼합콘크리트 7:3의 경우에 가장 큰 건조수축경향을 나타내었다. SEM사진 분석결과 재혼합 콘크리트에서 더 많은 미세공극들이 발견되었다. 결과적으로 한 종류의 레미콘을 이용하여 타설하였을 경우 보다 혼합사용 하였을 경우 응결지연 및 초기강도 저하현상이 나타나고, 더 큰 건조 수축 경향을 나타내어 일부 혼화제를 선별하여 혼합 사용하는 경우를 제외하고는 가능한 동일한 혼화제를 사용해야 할 것으로 판단된다.