• Title/Summary/Keyword: Lightspeed

Search Result 15, Processing Time 0.028 seconds

Shaping ability of Ni-Ti Rotary files in combination with GT Rotary Ni-Ti file (GT Rotary Ni-Ti file과 함께 사용한 구동용 Ni-Ti file의 근관 성형력 비교에 대한 연구)

  • Shin, Dong-Ryul;Park, Sang-Jin;Choi, Gi-Woon
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.2
    • /
    • pp.196-206
    • /
    • 2002
  • 본 연구는 근관의 치관부는 GT Rotary file을 이용하여 성형하고, 근단부는 K-Flexofile, ProFile .04, Lightspeed, HERO642 file로 성형하여 근관용 file의 근관성형력을 비교하는 것이다. 실험 표본으로는 resin simulated root canal blocks(Dentsply, Swiss)를 이용하였고 4개의 군으로 분류하여 실험을 실시하였다. 모든 resin block을 GT Rotary file(Dentsply, Swiss)을 이용하여 치관부를 형성한 후 근단부는 K-Flexofile(Dentsply, Swiss), ProFile .04 taper file(Denstply. Swiss), Lightspeed file(Lightspeed Tech., USA), HERO642 file(Micromega, France)로 ISO size #35까지 형성하였다. 성형 후 preparation time과 instrument failure를 측정하였고 최종 사용한 file을 resin block 내에 재위치시켜 working length의 변화량을 0.5mm 단위로 측정하였다. Resin debris에 의한 canal blockage를 조사하였으며, 근관 내의 인상을 채득하여 canal form을 평가하였다. 성형 전과 성형 후의 사진을 촬영하고 computer software를 이용하여 중첩시킨 후 canal aberration, canal transportation을 평가하여 다음과 같은 결과를 얻었다. 1. Preparation time, working length의 변화량, canal blockage, canal aberration, canal transportation에 있어서 Ni-Ti file이 stainless steel file에 비하여 우수하였다(p<0.05). 반면에 근관성형력에 있어서 canal form과 canal transportation을 제외하고는 세 Ni-Ti file 사이에는 유의차가 없었다(p>0.05). 2. Canal form 중 taper에 있어서 Lightspeed는 적절하지 못한 taper를 보여주었다(p<0.05). 3. Canal transportation에 있어서 Lightspeed 군과 HER0642 군이 K-Flexofile 군과 ProFile .04 군에 비해 적게 나타났고(p<0.05), 특히 만곡의 끝 부분에서는 Lightspeed 군이 가장 적게 나타났다(p<0.05). 이상과 같은 연구결과로 보아 부적절한 taper를 지니고 있던 Lightspeed fie과 HERO642 file 중 HERO642 file은 GT Rotary file과 함께 사용함으로써 적절한 taper로 형성할 수 있었으나 Lightspeed file은 효과적이지 못하였으므로 적절한 taper를 형성하기 위한 file이 치근의 중간부를 형성하기 위해 필요함이 확인되었다.

Evaluation of canal preparation for apical sealing with various Ni-Ti rotary instruments (수 종의 Ni-Ti 회전 기구들을 이용한 치근단 폐쇄 향상을 위한 근관 확대 평가)

  • Shin, Yoo-Seok;Shin, Su-Jung;Song, Min-Ju;Kim, Eui-Seong
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.4
    • /
    • pp.300-305
    • /
    • 2011
  • Objectives: The aim of this study was to evaluate the various NiTi rotary instruments regarding their ability to provide a circular apical preparation. Materials and Methods: 50 single canal roots were selected, cut at the cementodentinal junction and the coronal 1/3 of the canals was flared using Gates Glidden burs. Samples were randomly divided into 5 experimental groups of 10 each. In group I, GT files, Profile 04 and Quantec #9 and #10 files were used. In Group II Lightspeed was used instead of Quantec. In Group III, Orifice shaper, Profile .06 series and Lightspeed were used. In Group IV, Quantec #9 and #10 files were used instead of Lightspeed. In Group V, the GT file and the Profile .04 series were used to prepare the entire canal length. All tooth samples were cut at 1 mm, 3 mm and 5 mm from the apex and were examined under the microscope. Results: Groups II and III (Lightspeed) showed a more circular preparation in the apical 1mm samples than the groups that used Quantec (Group I & IV) or GT files and Profile .04 series.(Group V)(p < 0.05) There was no significant difference statistically among the apical 3, 5 mm samples. In 5 mm samples, most of the samples showed complete circularity and none of them showed irregular shape. Conclusions: Lightspeed showed circular preparation at apical 1 mm more frequently than other instruments used in this study. However only 35% of samples showed circularity even in the Lightspeed Group which were enlarged 3 ISO size from the initial apical binding file (IAF) size. So it must be considered that enlarging 3 ISO size isn't enough to make round preparation.

THE EFFECT OF NITI ROTARY INSTRUMENTATION ON THE CONFIGURATION OF APICAL ROOT CANAL (NiTi Rotary Instruments에 의한 근관형성이 치근단부 근관형태에 미치는 영향)

  • Oh, Hyun-Jung;Hong, Chan-Ui;Cho, Yong-Bum
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.244-253
    • /
    • 1997
  • During preparation of narrow curved canals, procedural accidents such as, ledge, zipping, and transportation are frequently encountered and may lead to failure of endodontic therapy. To reduce these procedural errors and efficiently manage curved canals, various modifications in instrumentation technique and the design and flexibility of instruments have been advocated. This study compared the maintenance of the original canal curvature, cross sectional canal shape, and preparation time during instrumentation with stainless steel hand (K-Flexo) file, and nickel-titanium rotary files (Profile and Lightspeed). Thirty resin blocks with simulated curved canals of 20~25 degrees were used and divided into three groups of 10 each. In group 1, canals were instrumented using a quarter turn/pull technique with K-Flexofiles. Group 2 canals were prepared with rotary NiTi Profiles. Group 3 was prepared with rotary NiTi Lightspeed instrument. Before and after instrumentation, all canals were scanned using stereo microcope, FlexCam camera, and Photoshop 3.0 computer program. The results were as follows : 1. All groups showed some loss of canal curvature after instrumentation. Average loss of canal curvature was 8.6 degrees for K-Flexofile, 7.7 degrees for Profile, and 5.8 degrees for Lightspeed. Lightspeed exhibited significantly less curvature loss than K-Flexofile (p<0.05). 2. At the apical 1-mm level, Profile produced significantly rounder canals than Lightspeed (p<0.05). At the 3-mm level, Profile and Lightspeed exhibited significantly rounder canals than K-Flexofile (p<0.05). 3. Preparation with Lightspeed was significantly faster than Profile and K-Flexofile, and Profile was faster than K-Flexofile (p<0.05). 4. There was no significant difference in incidence of zipping between the hand K-Flexofile and rotary NiTi (Profile and Lightspeed) instruments. Most of apical canals were slightly widened near the apical foramen. As a results of this study, rotary NiTi instruments are superior to the K-Flexofile in regard to the maintenance of original canal curvature, cross-sectional shape and preparation time. But more investigations and studies should be needed to evaluate the ideal canal instrumentation.

  • PDF

Shaping ability of Ni-Ti Rotary files in combination with GT Rotary Ni-Ti file

  • Shin, D.R.;Park, S.J.;Choi, G.W.
    • Proceedings of the KACD Conference
    • /
    • 2001.11a
    • /
    • pp.573.2-573
    • /
    • 2001
  • The objective of this study was to compare the apical shaping ability of the ProFile .04 taper, Lightspeed and HERO 642 rotary instruments and to assess the combined effect of GT Rotary files to Lightspeed and HERO 642 instruments. Forty-eight resin simulated root canal blocks divided into 4 groups with 12 canals. Forty-eight blocks were prepared by one operator with GT Rotary files using a high torque handpiece at 300 rpm. Thirty-six blocks in the three experimental groups were prepared with ProFile 04 taper file, Lightspeed file, HERO 642 file.(omitted)

  • PDF

Evaluation of apical canal shapes produced sequentially during instrumentation with stainless steel hand and Ni-Ti rotary instruments using micro-computed tomography

  • Lee, Woo-Jin;Baek, Seung-Ho;Bae, Kwang-Sik
    • Proceedings of the KACD Conference
    • /
    • 2003.11a
    • /
    • pp.597-598
    • /
    • 2003
  • I. Objectives Endodontic success depends on thoroughly cleaned and completely obturated root canal system. Effective cleaning and obturation will be achieved by well shaped canal. Numerous methodologies evaluating the efficacy and safety of canal preparation has been developed and the use of micro-computed tomography(MCT) in endodontic research is one of the latest innovations. This scientific tools could overcome the inherent limitations of other methodologies, and possesses the ability to visualize morphological characteristics in a detailed and accurate manner without destruction of the tooth and offers reproducible data in all three dimensions. The purpose of this study was to determine the optimal master apical file size with less transportation and more efficiency in removing the infected dentin. For this purpose we evaluated the transportation of canal center and change of untouched area after preparation sequentially from #25 file through #40 file with 3 different instruments:Stainless steel(SS) K-type hand instruments(MANI, Japan), ProFile.04 instruments (Dentply Tulsa Dental, USA) and Lightspeed instruments(Lightspeed Technology, San Antonio, USA) using micro-computed tomography.(omitted)

  • PDF

Interrelation Between Start-up Characteristic and Venture Capital Investment Portfolio for Strategic Decision (투자유치 전략을 위한 스타트업의 특성과 벤처캐피탈 투자구성의 상호연관성 연구)

  • Ko, Young-Hee;Lee, Ho-Sung
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.11 no.2
    • /
    • pp.63-73
    • /
    • 2016
  • In these days startup became one of the most hot issue in business world. The problem is many startup couldn't overcome the valley of death. For this reason many startup want to funded by venture capital. However startup's business is trade secret itself, so they have to make strategic approach to venture capital. The purpose of study is to find the way to make strategic decision for startup. By analyzing the relation between startup's characteristic and venture capital's investment portfolio. Four famous venture capital(Sequoia capital, Lightspeed venture, Firstround and Khosla venture) and their seed invested startup Dropbox, Airbnb, Snapchat, Uber and Instacart was selected for this study. As a result, each venture capital has their own invest category characteristic and their seed funding belong to their category. Moreover, between seed funded startup and 36,4% of 244 past invented company shown vertical relationship, beside 0.5% of past 244 invested company shown horizontal relationship. This result shown the importance of the relation between startup's characteristic and venture capital's portfolio. Startup have to check the venture capital's portfolio for the strategic approach for funding and venture capital have to make mutual positive portfolio for decreasing the risk.

  • PDF

Evaluation the absorbed dose in brain of dental radiography (치과방사선 검사에서 두부(brain)의 흡수선량 평가)

  • Jeon, Woon-Sun;Han, Dong-Kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.343-349
    • /
    • 2011
  • This study was aimed to evaluate the absorbed dose in brain of dental radiography. For radiographic exposure, PLD(photoluminescence dosimetry) chips placed in Rando phantom to measurement the absorbed dose to pituitary gland, orbit, maxillary sinus and submandibular glands, thyroid gland, esophagus. Equipments were used Kodak 2200, Kodak 8000C dental radiographic systems and computed tomography(Lightspeed VCT). The absorbed doses were measured at the same exposure parameters and distance by the clinical factor(kV, mA, sec). The result were as follows ; The absorbed dose for intra-oral radiography were 0.02~2.47cGy, the greatest absorbed dose was 2.47cGy for thyroid gland in maxillary right molar projection. the lowest adsorbed dose was 0.02cGy for submandibular glands in lower anterior projection. The absorbed dose for extra-oral radiography were 0.36~3.44cGy of cephalometric method, 0.14~12.82cGy of panoramic method, 8.17~253.63cGy of computed tomography, the greatest adsorbed dose was 253.63cGy for submandibular glands in maxillary CT scan. the lowest adsorbed dose was 0.14cGy for orbit in panoramic method. As a result, extra-oral radiography was measured more than intra-oral radiography. In particular, method which used computed tomography was measured more than 100 times than intra-oral radiography highly. Therefore, you must show a guideline in extra-oral radiography and an effort to reduce absorbed dose is demanded.

Evaluation of the Lens Absorbed Dose of MVCT and kV-CBCT Use for IMRT to the Nasopharyngeal Cancer Patient (비인두암 환자에 대한 세기조절 방사선치료 시 이용되는 MVCT와 kV-CBCT의 수정체 흡수선량 평가)

  • Choi, Jae Won;Kim, Cheol Chong;Park, Su Yeon;Song, Ki Weon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.131-136
    • /
    • 2013
  • Purpose: Quantitative comparative evaluation of the difference in eye lens absorbed dose when measured by MVCT and kV-CBCT, though such a dose was not included in the original IMRT treatment plan for the nasopharyngeal cancer patient. Materials and Methods: We used CT (Lightspeed Ultra 16, General Electric, USA) against an Anderson rando phantom (Alderson Research Laboratories Inc, USA) and established the plan for tomotherapy treatment (Tomotherapy, Inc, USA) and linear accelerator treatment (Pinnacle 8.0, Philips Medicle System) for the achieved CT images on the same condition with the nasopharyngeal cancer patient treatment plan. Then, align the ther-moluminescence dosimeter (TLD100 Harshaw, USA) with the eye lens, shot the lens with Tomotherapy MVCT under 3 conditions (Fine, Normal, and Coarse), and shot both lenses with kV-CBCT under 2 conditions (Low Dose Head and Standard Dose Head) 3 times each. Results: When we analyzed the eye lens absorbed dose according to MVCT and kV-CBCT images by using both Tomotherapy and Pinacle 8.0, we achieved the following result; According to Tomotherapy MVCT, RT 0.8257 cGy in the Coarse mode, LT 0.8137 cGy, RT 1.089 cGy and LT 1.188 cGy in the Normal mode, and RT 2.154 cGy and LT 2.082 cGy in the Fine mode. According to Pinacle 8.0 kV-CBCT, RT 0.2875 cGy and LT 0.1676 cGy in the Standard Dose mode and RT 0.1648 cGy and LT 0.1212 cGy in the Low-Dose mode. In short, the MVCT result was significantly different from that of kV-CBCT, up to 20 times. Conclusion: We think kV-CBCT is more effective for reducing the amount of radiation which a patient is receiving during intensity modulated radiation treatment for other purposes than treatment than MVCT, when we consider the absorbed dose only from the viewpoint of image-guided radiation therapy. Besides, we understood the amount of radiation is too sensitive to the shooting condition, even when we use the same equipment.

  • PDF

Absorbed Dose and Effective Dose for Lung Cancer Image Guided Radiation Therapy(IGRT) using CBCT and 4D-CBCT (폐암 영상유도방사선 치료 시 CBCT와 4D-CBCT를 이용한 흡수선량 및 유효선량에 관한 선량 평가)

  • Kim, Dae yong;Lee, Woo Suk;Koo, Ki Lae;Kim, Joo Seob;Lee, Sang Hyeon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.1
    • /
    • pp.57-64
    • /
    • 2016
  • Purpose : To evaluate the results of absorbed and effective doses using CBCT and 4D-CBCT settings for lung cancer. Materials and Methods : This experimental study. Measurements were performed using a Anderson rando phantom with OSLD(optically stimulated luminescent dosimeters). It was performed computed tomography(Lightspeed GE, USA) in order to express the major organs of the human body. Measurements were obtained a mean value is repeated three times each. Evaluations of effective dose and absorbed dose were performed the CL-IX-Thorax mode and Truebeam-Thorax mode CBCT. Additionally, compared Truebeam-Thorax mode CBCT with Truebeam-Thorax mode 4D-CBCT(Four-dimensional Cone Beam Computed Tomography) Results : Average absorbed dose in the CBCT of CL-IX was measured in lung 2.505cGy, heart 2.595cGy, liver 2.145cGy, stomach 1.934cGy, skin 2.233cGy, in case of Truebeam, It was measured lung 1.725cGy, heart 2.034cGy, liver 1.616cGy, stomach 1.470cGy, skin 1.445cGy. In case of 4D-CBCT, It was measured lung 3.849cGy, heart 4.578cGy, liver 3.497cGy, stomach 3.179cGy, skin 3.319cGy Average effective dose, considered tissue weighting and radiation weighting, in the CBCT of CL-IX was measured lung 2.164mSv, heart 2.241mSVv, liver 0.136mSv, stomach 1.668mSv, skin 0.009mSv, in case of Turebeam, it was measured lung 1.725mSv, heart 1.757mSv, liver 0.102mSv, stomach 1.270mSv, skin 0.005mSv, In case of 4D-CBCT, It was measured lung 3.326mSv, heart 3.952mSv, liver 0.223mSv, stomach 2.747mSv, skin 0.013mSv Conclusion : As a result, absorbed dose and effective Dose in the CL-IX than Truebeam was higher about 1.3 times and in the 4D-CBCT Truebeam than CBCT of Truebeam was higher about 2.2times However, a large movement of the patient and respiratory gated radiotherapy may be more accurate treatment in 4D-CBCT. Therefore, it will be appropriate to selectively used.

  • PDF

A phantom production by using 3-dimentional printer and In-vivo dosimetry for a prostate cancer patient (3D 프린팅 기법을 통한 전립샘암 환자의 내부장기 팬텀 제작 및 생체내선량측정(In-vivo dosimetry)에 대한 고찰)

  • Seo, Jung Nam;Na, Jong Eok;Bae, Sun Myung;Jung, Dong Min;Yoon, In Ha;Bae, Jae Bum;Kwack, Jung Won;Baek, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.53-60
    • /
    • 2015
  • Purpose : The purpose of this study is to evaluate the usefulness of a 3D printed phantom for in-vivo dosimetry of a prostate cancer patient. Materials and Methods : The phantom is produced to equally describe prostate and rectum based on a 3D volume contour of an actual prostate cancer patient who is treated in Asan Medical Center by using a 3D printer (3D EDISON+, Lokit, Korea). CT(Computed tomography) images of phantom are aquired by computed tomography (Lightspeed CT, GE, USA). By using treatment planning system (Eclipse version 10.0, Varian, USA), treatment planning is established after volume of a prostate cancer patient is compared with volume of the phantom. MOSFET(Metal OXIDE Silicon Field Effect Transistor) is estimated to identify precision and is located in 4 measuring points (bladder, prostate, rectal anterior wall and rectal posterior wall) to analyzed treatment planning and measured value. Results : Prostate volume and rectum volume of prostate cancer patient represent 30.61 cc and 51.19 cc respectively. In case of a phantom, prostate volume and rectum volume represent 31.12 cc and 53.52 cc respectively. A variation of volume between a prostate cancer patient and a phantom is less than 3%. Precision of MOSFET represents less than 3%. It indicates linearity and correlation coefficient indicates from 0.99 ~ 1.00 depending on dose variation. Each accuracy of bladder, prostate, rectal anterior wall and rectal posterior wall represent 1.4%, 2.6%, 3.7% and 1.5% respectively. In- vivo dosimetry represents entirely less than 5% considering precision of MOSFET. Conclusion : By using a 3D printer, possibility of phantom production based on prostate is verified precision within 3%. effectiveness of In-vivo dosimetry is confirmed from a phantom which is produced by a 3D printer. In-vivo dosimetry is evaluated entirely less than 5% considering precision of MOSFET. Therefore, This study is confirmed the usefulness of a 3D printed phantom for in-vivo dosimetry of a prostate cancer patient. It is necessary to additional phantom production by a 3D printer and In-vivo dosimetry for other organs of patient.

  • PDF