References
- Shilder H: Cleaning and shaping of the root canal, Dent Clin North Am. 18:269-96. 1974
- Eldees ME, Boraas JC: The effect of different files on the preparation shape of severely curved canal, lnt Endod J, 18:1-7, 1995
- Al-Omari MAO. Dummer PMH: Comparison of six files to prepare simulated root canals. Part 1, lnt Endod J, 25:57-66. 1992 https://doi.org/10.1111/j.1365-2591.1992.tb00738.x
- AI-Omari MAO, Dummer PMH: Comparison of six files to prepare simulated root canals. Part 2. lnt Endod J, 25:67-81, 1992 https://doi.org/10.1111/j.1365-2591.1992.tb00739.x
- Schafer E, Tepel J, Hoppe W: Properties of endodontic hand instruments used in rotary motion. Part 2. instrumentation of curved canals, J Endodon. 21:240-6. 1995
- Walia H, Brantley WA, Gerstein H: An initial investigation of the bending and torsional properties of Nitinol root canal files. J Endodon, 14:346-57, 1988 https://doi.org/10.1016/S0099-2399(88)80196-1
- Himel VT, Ahmed KM, Wood DM, Alhadainy HA: An evaluation Nitinol and stainless steel files used by dental students during a laboratory proficiency exam, Oral Surg Oral Med Oral Pathol, 79:232-7, 1995 https://doi.org/10.1016/S1079-2104(05)80289-6
- Espisito PT. Cunningham CJ: A comparison of canal preparation with nickel-titanium and stainless steel instruments. J Endodon, 21:173-6, 1995 https://doi.org/10.1016/S0099-2399(06)80560-1
- Glosson CR, Haller RH, Dove SB. del Rio CE: A comparison of root canal preparation using Ni-Ti hand. Ni-Ti engine-driven and K-Flex endodontic instruments, J Endodon. 21:146-51. 1995 https://doi.org/10.1016/S0099-2399(06)80441-3
- Clifford J: Cleaning and shaping the root canal system, Pathways of the pulp. 7th edn. St Louis. MO. USA. The CV Mosby Company. 253. 2000
- Blum JY, Cohen AG, Machtou P, Micallef JP: Location of contact areas of ProFile NiTi rotary instruments in relation to the forces developed during mechanical preparation of extracted teeth. lnt Endod J. 32(2):108-14, 1999 https://doi.org/10.1046/j.1365-2591.1999.00200.x
- Miserendino LJ. Moser JB. Heuer MA, Osetek EM: Cutting efficiency of endodontic instruments. II . Analysis of tip design. J Endod. 12(1):8-12, 1986 https://doi.org/10.1016/S0099-2399(86)80275-8
- Wildey WL, Senia ES: A new root canal instrument and instrumentation technique: a preliminary report. Oral Surg Oral Med Oral Pathol, 67:198-207, 1989 https://doi.org/10.1016/0030-4220(89)90332-0
- Wildey WL. Senia ES, Montgomery S: Another look at root canal instrumentation, Oral Surg Oral Med Oral Pathol, 74:499-507, 1992 https://doi.org/10.1016/0030-4220(92)90303-8
- Knowles KI, Ibarrola JL, Christiansen RK: Assessing apical deformation and transportation following the use of Lightspeed root canal instruments. lnt Endod J, 29:113-7. 1996 https://doi.org/10.1111/j.1365-2591.1996.tb01171.x
- Vulcain JM, Calas P: The three wave concept of HERO 642. Endod Pract, 2(2):20-30, 1999
- Abou-Rass M, Jastrab RJ: The use of rotary instruments as auxiliary aids to root canal preparation of molars. J Ended. 8:78-82, 1982 https://doi.org/10.1016/S0099-2399(82)80262-8
- Kum KY, Spangberg L, Cha BY et al: Shaping ability of three ProFile rotary instrumentation techniques in the simulated resin root canals, J Ended. 12:719-23, 2000
- Kanavagh D. Lumley PJ: An in vitro evaluation of canal preparation using ProFile .04 and .06 taper series instruments, Endod Dent Traumatol, 14:16-24, 1998 https://doi.org/10.1111/j.1600-9657.1998.tb00803.x
- Lim SS, Webber J: The validity of simulated root canals for the investigation of the prepared root canal shape, lnt Endod J, 18:240-6, 1985 https://doi.org/10.1111/j.1365-2591.1985.tb00450.x
- Thompson SA, Dummer PMH: Shaping ability of ProFile .04 taper series 29 rotary nickel-titanium instruments in simulated root canals. Part 1, lnt Endod J, 30:1-7, 1997 https://doi.org/10.1111/j.1365-2591.1997.tb01093.x
- Thompson SA, Dummer PMH: Shaping ability of ProFile .04 taper series 29 rotary nickel-titanium instruments in simulated root canals. Part 2. lnt Endod J, 30:8-15, 1997 https://doi.org/10.1111/j.1365-2591.1997.tb01092.x
- Thompson SA, Dummer PMH: Shaping ability of Lightspeed rotary nickel-titanium instruments in simulated root canals. Part 1, J Endod, 23:698- 702, 1997 https://doi.org/10.1016/S0099-2399(97)80405-0
- Thompson SA. Dummer PMH: Shaping ability of Lightspeed rotary nickel-titanium instruments in simulated root canals. Part 2, J Ended, 23:742-7, 1997 https://doi.org/10.1016/S0099-2399(97)80347-0
- Thompson SA. Dummer PMH: Shaping ability of HERO 642 rotary nickel-titanium instruments in simulated root canals, Part 1, lnt Endod J, 33:248-54, 2000 https://doi.org/10.1046/j.1365-2591.2000.00287.x
- Thompson SA, Dummer PMH: Shaping ability of HERO 642 rotary nickel-titanium instruments in simulated root canals. Part 2. lnt Endod J. 33:255 -61, 2000 https://doi.org/10.1046/j.1365-2591.2000.00288.x