• Title/Summary/Keyword: Lights-Out

Search Result 135, Processing Time 0.027 seconds

putting out lights detector LED Type Signal light Test of a Patented Article Manufacture.Establishment.Examination Report (단심검지기(LED형 신호등용) 시제품 제작.설치.시험에 관한 보고)

  • Kho, Yeong-Whan;Seok, Tae-Woo;Ko, Yang-ok
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1650-1655
    • /
    • 2007
  • A lights-out detector, which helps the person in charge of maintenance make a quick judgment in the event of a failure of LED-type traffic lights, was explored/developed and installed/ tested, at Seoul Metro, after they developed a patented pilot product in 2005; and, a product improvement test was conducted to ensure reasonable maintenance of signaling facilities. Having better compatibility with existing circuit in use and displaying stable load current, the device makes the maintenance of lights-out detection and alert easier.

  • PDF

A Study on the Effective Maintenance Method of the Stair Passage Leading Light installed In the Shopping Building (상가건물 계단통로유도등의 유지관리 효율화 방안에 관한 연구)

  • Lee, Young-Sam
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.1
    • /
    • pp.1-8
    • /
    • 2016
  • This study was conducted by survey and inspection of stair passage leading lights in shopping buildings which are more than 5 stories and have an underground parking lot located at Pyeongtaek-si and Seongnam-si. Number of shopping building for this study is 30 and of stair passage leading light inspected by two lights in each shopping building is 60. The result of this study is that the type of installed leading lights is LED(77%), and 60% of leading lights has problem such as no cleaning, scratch and discoloration, etc. The height of installed leading lights meets the fire law which is less than 1m from the floor. Visible condition of leading lights is good except some leading lights which have a little visible problem due to banner advertisement. 37% of standby power has flickered and went out. 93% of total leading lights meets the fire law which is more than 1lux from 0.5m distance, but cold cathode fluorescent lamps(CCFLs) have the problem which not meets proper brightness level based on fire law. In additional measurement result, zero lux of leading lights is 32%(from 1m distance), 68%(from 1.5m distance) and 98%(from 2m distance). Leading light is very important facility because it is eyes and guide when emergency. Therefore, proper fire facility operating function inspection and total detailed inspection are important to keep the good condition of leading light except simple visual check, and also improvement in law system of type approval, fire construction inspection and illumination level will be needed.

Study on Resources Annexation in Tongyeong Marine Ranching I. Effects of Zooplankton Attraction by Night-lights (통영 바다목장 자원조성을 위한 연구 I. 야간점등에 의한 동물플랑크톤 유도효과)

  • Yoon, Ho-Seop;Choi, Sang-Duk
    • Korean Journal of Environmental Biology
    • /
    • v.24 no.2 s.62
    • /
    • pp.126-137
    • /
    • 2006
  • Effect of night-lights on zooplankton attraction has been studied in Tongyeong marine ranch area during the period from 12 July to 30 August, 2004. Each sampling has been carried out to collect zooplankton from both control area in natural waters experiment area of night-lights waters at night. A total of 43 taxa of zooplankton occurred during the study. Copepods showed the prosperity in species number with 15 species. Acartia erythraed and Copepodite occurred abundantly in night-lights waters. Zooplankton abundance appeared to increase in night-lights mainly due to the gathering of copepods and larvae through the study period. Average $3\sim166$ times of zooplankton abundance was recorded in night-lights when compared with that in control area of natural waters due to the gathering of copepods and larvae. Cluster analysis, based on monthly abundance data of the 13 most frequent species, showed that the species were seperated into two different groups: the photo-positive group and the photo-negative group.

Response of Filefish to the Colored Lights (색광에 대한 쥐치의 반응)

  • 양용림
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.17 no.1
    • /
    • pp.7-11
    • /
    • 1981
  • The author carried out an experiment to find out the responsing patterns of filefish, Stepha nolepis cirrhifer (Temminck et Schlegel) to the color lights. The experimental tank (360LX50WX55H cm) was set up in a dark room. Six Longitudinal sections each being 60 em intervals are marked in the tank to observe the location of the fish. Water depth in the tank was kept 50 em level. Light bulbs of 20W were placed at the both ends of the tank to be projected the light horizontally into the tank. Two different colored filters were selected in combination from four' colors-red, blue, yellow, and white, and were placed in front of the light bulbs to make\ulcorner different light of color. Light intensity were controlled by use of auxiliary filters intercepted between the bulb and the filter. The fish were acclimatized in the dark for 40 minutes prior to employ in the experiment. Upon turning on the light, the number of fish in each section was counted 40 times in every 30 seconds, and the mean of the number of fish in each section was given as the gathering rate of the fish. The results obtained are as follows: 1. Color of light, to which the fish gathered abundantly was found in the named order of blue, white, green, and red. 2. The differences of gathering rate upon arbitary combined two color lights were shown significant, and the differences increased remarkably in accordance with the lapse of illuminating period.

  • PDF

Design of the Lens Structure for COB type LED Safety Luminaires (COB형 LED 보안등을 위한 렌즈 구조 설계)

  • Jang, Sung-Whan;Jung, Byoung-Jo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.8
    • /
    • pp.1-8
    • /
    • 2013
  • The study carried out in this dissertation focuses on the lens structure design and the light distribution for LED safety luminaires using COB type LED module. Lens structures for LED lights has been designed 1) to induce light diffusion by dual process of internal reflection and refraction, 2) to minimize the inherent LED lights' glittering, and 3) to have uniform brightness. The lens designed with the proposed structures function as diffusers for the divergence of the LED lights so that they form a wide angle of view and adjust the light distribution. We designed of lens with stable uniformity factor and average roughness using aspheric optics property. Finally we made the analysis data of the simulated data.

A Study on the Lights and Shapes for the Small Fishing Vessel and the Vessels Towing and Being Towed (소형어선 및 예인선단의 등화 및 형상물에 관한 고찰)

  • Chong, Dae-Yul
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.21 no.4
    • /
    • pp.421-427
    • /
    • 2015
  • This study aims at reviewing first the cases of marine accidents of small fishing vessels and vessels towing and being towed and, the problems concerning such lights and shapes that could be misunderstood for those in concerned Rules, or that could impair their distinctive characteristics or obstruct to keep a proper look-out. And then I wish to make a suggestion of the necessity of amending the National Laws which stipulate the rules for the ship's lights and shapes as follows; Firstly, by amending the "Standard of Construction and Equipment for the Less Than 10 Gross Tonnage of Small Fishing Vessels" small fishing vessel must be equipped with the lights and shapes that are the same as those of "vessel engaged in fishing" prescribed by Rule 26 of the "COLREG 1972" and Rule 84 of the "Maritime Safety Law Act". Secondly, "Standard of Fishing Vessels Equipment" which stipulate the rules concerning the exception of the running lights and radar reflector for the small fishing vessels must be amended to meet the requirement of Rule 20 of the "Maritime Safety Act". Thirdly, the definition of "Length of the tow" which prescribed by Rule 2 of the "Maritime Safety Act" must be amended to meet the Rule 24 of the "COLREG 1972". And also I wish to adhere to the importance of displaying the adequate vessel lights and shapes by every mariner for preventing marine accidents.

A Study of the Marine Traffic Safety using the LED Flashing Number Plate for Light Buoys (등부표 식별용 LED 발광 번호판을 활용한 해상교통 안전에 관한 연구)

  • Shim, Moo-Jun;Lee, Tae-Hwan
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2010.04a
    • /
    • pp.448-452
    • /
    • 2010
  • The traditional Aids to Navigations(AtoN) have been ensuring the safety of ships by indicating the passage and dangers by depending on the flashing lights. But the more the industrial complex behind port which is all over the country involving the Ulsan port developed, the more the lights behind port is stronger, and then the distinguishment of the signal of AtoN from the lights behind port is more difficult. And It is urgently needed to prepare the counterplan about the ensurement of safety because the authorities levels up the limit tonnage of the ships which are sail in and out during night to improve the operation of port through reducing of the traffic jam So, the method of direct lighting like LED non-neon is applied to unmanned lighthouses or light beacon, and the LED flashing number plate is applied to light buoys whose light power is weaker than to improve distinguishment and to be easy positioning of ships. As a result, the users of Ulsan port comment favorably on this item and the development of AtoN must be continuos to overcome the lights behind port.

  • PDF

Study on Thermal Performance of Multiple LED Packages with Heat Pipes (히트 파이프를 이용한 다중 LED 패키지의 방열 성능 연구)

  • Hwang, Soon-Ho;Lee, Young-Lim
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.6
    • /
    • pp.569-575
    • /
    • 2011
  • Since the high heat generation of LED chips can cause a reduction in lifetime, degradation of luminous efficiency, and variation of color temperature, studies have been carried out on the optimization of LED packaging and heat sinks. Recently, LED packages have been applied to high-power lights such as car headlamps or street lights, and it is known that cooling using only free convection is not at all efficient. Thus, in this study, a heat pipe with forced convection was examined for the optimization of the cooling performance in high-power LED lights. In addition, optimal on-off control of a fan was adopted to increase the fan lifetime, since the lifetime of the fan is generally shorter than that of the LEDs.

A Study on Growth of the Green Leaf Lettuce Depends on PPFD and Light Quality of LED Lighting Source for Growing Plant (식물재배용 LED 광원의 광질과 PPFD에 따른 청치마상추의 성장에 관한 연구)

  • Yang, Jun-Hyuk;Choi, Won-Ho;Park, Noh-Joon;Park, Dae-Hee
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.2
    • /
    • pp.142-147
    • /
    • 2015
  • The artificial light sources for growth of plant are usually high-pressure sodium lamp, metal haloids lamp, and fluorescent light; however, these light sources have relatively weaker Red and Blue lights that are necessary for growth of plants. Especially the effect of Photosynthetic Photon Flux Density (PPFD) is pointed out as the weakness. Meanwhile, LED light source can be selected by specific wavelength to greatly improve the effect of PPFD. In this regard, this paper aims to investigate the promotion of plant growth by measuring photosynthetic photon flux density (hereafter referred to as PPFD) according to changes in light quality of the LED light sources. Towards this end, LED light sources for plant growth were produced with 4 kinds of mono-chromatic lights and 6 kinds of combined lights by mixing red, blue, green and white lights. A comparative analysis was conducted to investigate the effects of optical properties and PPFD on plants (green leaf lettuce) using the produced light sources. The results monochromatic light has fastest growth rate, but plant growth conditions have poor. This being so, mixed light is suitable for the green leaf lettuce.

Effects of monochromatic lights on the growth performance, carcass characteristics, eyeball development, oxidation resistance, and cecal bacteria of Pekin ducks

  • Hua, Dengke;Xue, Fuguang;Xin, Hairui;Zhao, Yiguang;Wang, Yue;Xiong, Benhai
    • Animal Bioscience
    • /
    • v.34 no.5
    • /
    • pp.931-940
    • /
    • 2021
  • Objective: Light is a significant component of housing environment in commercial poultry industry. This study was conducted to investigate whether Pekin ducks perform better under monochromatic lights than under white light with respect to their growth performance, carcass quality, eyeball development, oxidation resistance, and cecal bacterial communities. Methods: A total of 320 one-day-old male Pekin ducklings were randomly distributed into five rooms with different light treatments, white, red, yellow, green, and blue light. Each room consisted of 4 replicated pens with 16 ducklings per pen. Results: Blue light significantly decreased fat deposition by decreasing abdominal fat. Long wavelength light, such as red, green, and yellow light, considerably increased the back-to-front eyeball diameter and the red light potentially enlarged the side-to-side eyeball diameter. Besides, the blue light had adverse effects on the oxidation resistance status in terms of increasing the product malonaldehyde of lipid oxidation and decreasing the plasma concentration of total superoxide dismutase. The phyla of Firmicutes had the greatest abundance in the green and blue treatments, while Bacteroidetes in blue treatment was the least. The genus of Faecalibacterium was significantly lower under the red light. Conclusion: The high risk of cecal health status and decreased anti-oxidation activity were observed under blue light. Red, yellow, and green light might increase the risk of oversized eyeball and cecal illness. Therefore, monochromatic lights compared to white light did not show advantages on the performance of housing ducks, it turns out that the white light is the best light condition for grow-out ducks.