• 제목/요약/키워드: Lightning discharge

검색결과 90건 처리시간 0.025초

배전선로의 내뢰흔 설계사양 및 전기적 특성 평가 (Arcing horn design specification and electrical characteristics special quality estimation of distribution line)

  • 김석수;최익순;박태곤
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.472-473
    • /
    • 2007
  • This study evaluated electrical characteristics of the manufactured arcing horn whose rated voltage and nominal discharge current were 18kV and 2.5kA, respectively. In this study, residual voltage and lightning impulse flashover voltage were examined. The arcing horn showed excellent electrical characteristics that residual voltage and lightning impulse flashover voltage were 55kV below and 121kV at 115mm, respectively. Therefore the manufactured arcing Horn is considered that it would show good performance for protecting electrical wires and line post insulators from lightning impulse, if it were applied to real fields.

  • PDF

Series Gap Type 피뢰기의 뇌임펄스 동작책무 및 온도의존성에 관한 연구 (A Study of Lightning Impulse Operating Duty and Temperature Dependence of Series Gap Type Arrester)

  • 조한구;유대훈
    • 한국전기전자재료학회논문지
    • /
    • 제22권8호
    • /
    • pp.659-664
    • /
    • 2009
  • This paper describes lightning impulse operating duty performance and temperature dependence of series gap type for transmission line arresters. The ageing parameters of lightning arresters are impulse current, moisture ingress, temperature ageing and so on. Especially it is important to estimate the change of electrical characteristics by lightning impulse current. In the discharge withstand test, total energy applied to the ZnO arrester each time is 4/10 ${\mu}s$, 30 kA. and in the operating duty test, the arrester has passed the test if thermal stability is achieved, if the residual voltage measured before and after the test is not changed by more than 5 %, and after the test reveals no evidence of puncture, flashover or cracking of the ZnO block. As a results, the residual voltage was in the range of 17.2${\sim}$20.3 kV and ZnO block bear up against at 2 shot of series impulse current of 30 kA. Also it was so excellent that the mechanical destruction does not occur at the 2 groups of 5 impulses current of 2/20 ${\mu}s$ 10 kA. According to the tests, it is thought that the ZnO arrester shows good stability with impulse current test. and it was found that the ambient temperature is increased resistive leakage current was increased in the range 47.3${\sim}$167.4 ${\mu}A$.

임펄스전압에 의한 수증방전특성의 분석 (Analysis of Underwater Discharge Characteristics Caused by Impulse Voltages)

  • 최종혁;안상덕;이복희
    • 조명전기설비학회논문지
    • /
    • 제22권2호
    • /
    • pp.128-133
    • /
    • 2008
  • 이 논문은 반구형 수조에 설치되어 있는 침전극과 구형전극에 표준뇌임펄스전압을 인가하였을 때 나타나는 수중 방전현상과 절연파괴특성을 나타낸다. 이 논문의 목적은 뇌서지에 대한 과도접지임피던스와 관련된 기본적인 특성을 파악하는데 있다. 인가전압의 극성과 물의 저항률에 따른 방전광을 촬영하였고 절연파괴전압의 의존성을 측정하였다. 침전극과 구형전극의 끝단에서 스트리머코로나가 발생하였고 접지된 수조를 향하여 단계적으로 진전하였다. 저항률에 따른 절연파괴전압은 V자 형태를 나타내며, 구형전극의 절연파괴전압-시간곡선이침전극보다 높게 나타났다.

Investigations on Partial Discharge, Dielectric and Thermal Characteristics of Nano SiO2 Modified Sunflower Oil for Power Transformer Applications

  • Nagendran, S.;Chandrasekar, S.
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권3호
    • /
    • pp.1337-1345
    • /
    • 2018
  • The reliability of power transmission and distribution depends up on the consistency of insulation in the high voltage power transformer. In recent times, considering the drawbacks of conventional mineral oils such as poor biodegradability and poor fire safety level, several research works are being carried out on natural ester based nanofluids. Earlier research works show that sunflower oil has similar dielectric characteristics compared with mineral oil. BIOTEMP oil which is now commercially available in the market for transformers is based on sunflower oil. Addition of nanofillers in the base oil improves the dielectric characteristics of liquid insulation. Only few results are available in the literature about the insulation characteristics of nano modified natural esters. Hence understanding the influence of addition of nanofillers in the dielectric properties of sunflower oil and collecting the database is important. Considering these facts, present work contributes to investigate the important characteristics such as partial discharge, lightning impulse, breakdown strength, tandelta, volume resistivity, viscosity and thermal characteristics of $SiO_2$ nano modified sunflower oil with different wt% concentration of nano filler material varied from 0.01wt% to 0.1wt%. From the obtained results, nano modified sunflower oil shows better performance than virgin sunflower oil and hence it may be a suitable candidate for power transformer applications.

배전급 피뢰기(18kV, 5kA)용 ZnO 바리스터 소자 개발 (Development of ZnO Varistor for Distribution Surge Arrester (18kV, 5kA))

  • 박춘현;윤관준;조이곤;정세영;서형권
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.212-216
    • /
    • 2000
  • ZnO varistors for distribution surge arrester (18kV, 5kA) were developed and tested microstructure and electrical characteristics. Microstructure of ZnO varistor was consisted of ZnO grain, spinel phase and Bi-rich phase. Average grain size of ZnO varistor was $\mu\textrm{m}$ Reference voltage and lightning impulse residual voltage of ZnO varistor exhibited a good haracteristics above 5.5kV and below 11.56kV, respectively. Consequently, discharge capacity which is the most important characteristics of ZnO varistor for surge arrester exhibited excellent properties above 70kA at twice high-current impulse test. Moreover, variation rate of reference voltage and lightning impulse residual voltage showed below 5% and 2% after high-current impulse test, respectively. Leakage current and watt loss of ZnO varistor will not increase during accelerated aging test at stress condition, such as 3.213kV/$115^{\circ}C$/1000h.

  • PDF

특별저전압 직류 전원회로에 유용한 서지방호장치의 설계와 특성 (Design and Behavior of Validating Surge Protective Devices in Extra-low Voltage DC Power Lines)

  • 심서현;이복희
    • 조명전기설비학회논문지
    • /
    • 제29권3호
    • /
    • pp.81-87
    • /
    • 2015
  • In order to effectively protect electrical and electronic circuits which are extremely susceptible to lightning surges, multi-stage surge protection circuits are required. This paper presents the operational characteristics of the two-stage hybrid surge protection circuit in extra-low voltage DC power lines. The hybrid surge protective device consists of the gas discharge tube, transient voltage suppressor, and series inductor. The response characteristics of the proposed hybrid surge protective device to combination waves were investigated. As a result, the proposed two-stage surge protective device to combination wave provides the tight clamping level of less than 50V. The firing of the gas discharge tube to lightning surges depends on the de-coupling inductance and the rate-of-change of the current flowing through the transient voltage suppressor. The coordination between the upstream and downstream components of the hybrid surge protective device was satisfactorily achieved. The inductance of a de-coupler in surge protective circuits for low-voltage DC power lines, relative to a resistance, is sufficiently effective. The voltage drop and power loss due to the proposed surge protective device are ignored during normal operation of the systems.

전자통신설비의 SPD 소손사례 및 열화진단기법 분석 (Survey of Damage Cases for Surge Protective Devices Installed Electrical Communication Systems and Analysis of Degradation Diagnosis Method)

  • 임종욱;이재영;권준혁
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2009년도 정보통신설비 학술대회
    • /
    • pp.15-18
    • /
    • 2009
  • In recent years electric devices and telecommunication facilities were often damaged by surge generated lightning discharge. When the service was interrupted by failure of electrical devices due to surge the social loss is very enormous. Therefore in order to protect electrical systems against lightning, SPDs(Surge protective device) have been used But damaged SPDs often make some troubles like fire and interrupt of service. In this work, 3rd harmonic leakage current defection method was applied as the diagnosis of SPD degradation and the effectiveness of this method was verified by field survey.

  • PDF

Suitability of Palm Based Oil as Dielectric Insulating Fluid in Transformers

  • Azis, Norhafiz;Jasni, Jasronita;Kadir, Mohd Zainal Abidin Ab;Mohtar, Mohd Nazim
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권2호
    • /
    • pp.662-669
    • /
    • 2014
  • Mineral oil has been widely used as dielectric insulating fluid in transformers due to its excellent performance in-service. However, there are few issues with mineral oil such as it has poor biodegradability and could contaminate the environment if a spillage occurs. With the increasing tight regulation on safety and environment, alternative fluids for mineral oil are currently being investigated and among the suitable candidate is the vegetable oil. There are different types of vegetable oils and one of them is the palm based oil. At the moment, extensive research works are carried out to examine its feasibility to be applied in transformers. This paper will review the previous research works that were carried out to examine the suitability of palm based oil as dielectric insulating fluid in transformers. The physical and chemical properties of palm based oil are studied based on viscosity, acidity, oxidation stability and flash point. Next, the electrical characteristics of palm based oil are examined based on AC breakdown voltage, relative permittivity, dissipation factor and partial discharge.

운방전에 의해 발생한 전계와 자계 파형의 파라미터 분석 (Parametric Analysis of the Electric and Magnetic Field Waveforms Produced by Intracloud Lightning Discharges)

  • 이복희;이우철
    • 조명전기설비학회논문지
    • /
    • 제20권2호
    • /
    • pp.81-88
    • /
    • 2006
  • 본 연구에서는 뇌방전의 전기적 특성에 대해 파악하고자 전계 및 자계 측정시스템을 구축하였다. 주파수 대역 및 응답감도는 전계측정시스템 $40[Hz]{\sim}2.6[MHz]$, 2.1[(V/m)/mV], 자계 측정시스템 $300[Hz]{\sim}1[MHz]$, 28[nT/mV]이다. 구축한 측정시스템을 이용하여 뇌방전에 의해 발생한 전계와 자계 파형을 관측하고, 파형의 여러 가지 파라미터에 대해 통계적으로 분석하였다. 그 결과 전계와 자계 파형은 극성의존성이 미약하였으며, 전계와 자계 파형의 상승시간과 영점교차시간의 평균값은 각각 $5.5[{\mu}s],\;21[{\mu}s]$로 나타났다.

$SF_6$$SF_6/CO_2$ 혼합기체 중에서의 뇌임펄스 전구방전의 특성 (Characteristics of lightning impulse pre-breakdown discharge in $SF_6\;and\;SF_6/CO_2$ mixtures)

  • 이복희;오성균;백영환
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 춘계학술대회논문집
    • /
    • pp.57-60
    • /
    • 2005
  • This paper describes the experimental results of the pre-breakdown phenomena in $SF_6/CO_2$ mixtures under non-uniform electric fields caused by positive and negative lightning negative voltages. $SF_6/CO_2$ mixtures have an advantage of an environmental aspect and cost reduction, and safety aspects. In order to analyze the pre-breakdown processes in $SF_6/CO_2$ mixtures stressed by impulse voltages, pre-breakdown current and luminous signals were measured by a shunt and a photo-multiplier tube, respectively. Dielectric strengthes of $SF_6/CO_2$ mixtures were investigated. Additionally, characteristics of discharge channels were observed by high speed cameras and the physical properties were discussed. The pre-breakdown propagates with a stepwise process. The in to breakdown from the corona onset point in positive polarity was shorter than that in negative polarity. The time intervals of positive leaders are shorter than those of negative leaders, and the path of positive leader channel is zigzag.

  • PDF