송전계통 및 변전소 뇌서지 보호방안 연구 (A Study on the Lightning Surge Protection Methods on Transmission System and Substation)

  • 김재관;정채균;이종범;조한구;서재호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권6호
    • /
    • pp.279-285
    • /
    • 2005
  • The lightning causes the damage of power system equipments as well as large power failure. Therefore, the insulation design should be established not only to decrease the damage of the facilities itself but also to increase the reliability of electric power system. This paper describes the useful way applying underbuilt ground wire and guy wire in transmission tower that safely protect the substation equipments. One or more shield wires under the phase conductor will not intercept lightning stroke, but they may improve reduce lightning voltages almost as effectively as if they were above the phase conductors. And the guy wires will mitigate the tower surge response. These would not only reduce backflashover possibility but also minimize crest and duration of surges entering the substation. EMTP is used to analyze the efficiency of the proposed methods.

국내 해상풍력발전단지 낙뢰피해 영향 분석에 관한 연구 (A Study on the Analysis of Lightning Damage Impact in Domestic Offshore Wind Farm)

  • 서진규;김규호
    • 전기학회논문지
    • /
    • 제65권2호
    • /
    • pp.247-252
    • /
    • 2016
  • The latest offshore wind turbines are easily exposed to lightning strikes because they are designed with longer blades and taller height to satisfy the growing capacity demands. The generation facilities and elements of the offshore wind farm are more vulnerable to lightning damage because of more severe, unpredictable weather conditions. Therefore, this paper presents the analysis of measure for lightning overvoltage mitigation in offshore wind farm planned in South Korea southwest seashore. The sensitivity analysis includes the steady state and transient state characteristics of offshore wind farm and proposes the countermeasure for mitigation of transient overvoltage by considering earth resistivity of the offshore environment.

온라인(On-line) 낙뢰정보 활용 서비스의 개발과 활용 (Development and application of on-line lightning information service)

  • 곽주식;우정욱;강연욱;구교선;최한열
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.696-698
    • /
    • 2007
  • As overhead transmission lines are exposed to the outdoor weather, lightning induced fault accounts for about 66% of faults in transmission lines. The lightning may cause the damage of power system apparatus or the shut down of electricity. Not only in order to decrease the damage of the power system itself but also to ensure the reliable power supply, an appropriate insulation design based on the long-term lightning statistics is required. Meanwhile, real time information of lightning might be more useful to quickly locate the point of lightning induced fault in the line, leading to minimization of the adverse effects derived from the fault. Korea Electric Power Corporation has been providing an on-line lightning information service, named as KLDNet, since 2006 in order to meet the need inside our company. This paper describes the development and application of the information system.

  • PDF

다중 뇌충격전류에 의한 산화아연형 피뢰기 소자의 특성 변화 (Characteristic Changes of ZnO Arrester Blocks by Multiple-lightning Impuse Currents)

  • 길경석;한주섭
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권12호
    • /
    • pp.685-690
    • /
    • 2000
  • Multiple-lightning impulse currents are a general feature of the lightning ground f=flash. It is therefore necessary for lightning arresters used in power systems to be estimated by applying not only a single-lightning impulse current but also a multiple-lightning impulse currents. This paper presents the effects of multiple-lightning impulse currents on deterioration of ZnO arrester blocks. The multiple-lightning impulse generator which can produce quadruple 8/20$[\mus]$ 5[kA] with separation time of 30~120[ms] is designed and fabricated. The total energy applied to the arrester block at each impulse is about 1,200[J]. In experiment, various parameters such as leakage current component, reference voltage, and temperature are measured with the number of applied impulse current. Also, micro-structure changes of the ZnO blocks after applying the single and the multiple-lightning impulse currents of 200 times are compared. The experimental results indicate that the types of arrester blocks are more vulnerable to deterioration or damage by multiple-lightning impulse currents.

  • PDF

항공기의 구조물과 시스템에 대한 낙뢰직접영향에 관한 연구 (A study on the direct effect of lightning on structures and systems of aircraft)

  • 정덕영;양현덕
    • 항공우주시스템공학회지
    • /
    • 제10권2호
    • /
    • pp.41-45
    • /
    • 2016
  • Statistical data show that a large aircraft(transport category) is struck by lightning once a year or once per 1,000 ~ 20,000 flight time. The protection design for lightning must be applied to the aircraft because an aircraft is developed on condition that it is absolutely struck by lightning. For the proper protection design, we need to understand direct effect and indirect effect of lightning. This paper described the direct effect of lightning on aircraft's structures and systems.

높이 20미터 미만인 구조물의 낙뢰리스크 평가 (Lightning Risk Assessment for Structures Lower than 20m High)

  • 이주철;김기현;이영철
    • 조명전기설비학회논문지
    • /
    • 제26권12호
    • /
    • pp.21-27
    • /
    • 2012
  • Korean Industrial Standards for lightning protection system complies with IEC standards. However, the standards are applicable only to buildings and structures more than 20 meters in high. Therefore, it is necessary to determine whether lightning protection system should be installed on structures lower than 20 meters high. This paper proposes an efficient method of assessing risk against lightning of structures lower than 20 meters high. The method suggests simplified lightning protection system and provides selecting an appropriate protection level. The suggested method assumes that structure under assessment has no lightning protection system and there is no person around the structure at the moment of lightning stroke. A simplified method of assessing the risk to human within the structure is developed by adopting the general assessment factor. The selection of a protection level is possible by comparing tolerable risk with physical damage risk caused by a direct lightning. Finally, this paper gives ways to establish surge protection measures when a structure with lightning risk is within a radius of 2km from the assessed structure even if this structure requires no lightning protection system.

항공기 낙뢰 시험을 위한 Component A 축소 파형 도식화 방법 (A Method of Plotting Component A Scaled Waveform for Aircraft Lightning Test)

  • 조재현;김윤곤;김동현;이학진;명노신
    • 한국항공우주학회지
    • /
    • 제49권9호
    • /
    • pp.801-811
    • /
    • 2021
  • 낙뢰는 짧은 시간 동안 다량의 에너지를 항공기에 전달하여 치명적인 결과를 초래할 수 있다. 특히 낙뢰는 고온의 열과 전류를 동반하여 항공기 표면 손상과 내부 전자장비에 영향을 미쳐 비행의 안전에 심각한 영향을 미칠 수 있다. 이를 분석하기 위한 낙뢰 시험에는 미항공우주원고서 SAE ARP 5412B에 규정된 최대전류 200kA인 Component A 파형이 사용된다. 하지만 실제 낙뢰 크기는 대부분 35kA 내외로 발생하며 전기체 대상으로 하는 낙뢰 간접 시험에서 내부 전자장비 손상 예방을 위해 파형을 축소하여 시험을 진행한다. 본 연구에서는 기존 Component A 축소 파형을 도식화하는 방법을 알아보고 그 한계를 분석하였다. 나아가 항공기 낙뢰 Component A 파형의 보정계수를 조절하는 방식의 신규 축소 파형 도식 방법을 제안한다. 마지막으로 전자기 해석 소프트웨어 EMA3D를 활용하여 EC-155B 헬리콥터 내부 케이블 하네스의 파형 감소비에 따른 내부 유도 전류 크기 감소비를 비교하였다.

항공기용 차폐 케이블의 구조에 따른 RTCA DO-160G Sec. 22 간접낙뢰 영향성 분석 (Analysis of Indirect Lightning Impact on Aircraft Shielded Cable Structure in accordance with RTCA DO-160G Sec. 22)

  • 김성연;김태현;김민성;이왕상
    • 항공우주시스템공학회지
    • /
    • 제17권6호
    • /
    • pp.35-45
    • /
    • 2023
  • 본 논문에서는 항공기용 차폐 케이블의 구조에 따른 간접낙뢰의 영향성을 분석하고, 차폐력 향상을 위한 차폐 케이블 구조를 분석하였다. 항공기에서 케이블은 부품 중에 가장 많은 비중을 차지하고 있고, 항공기 프레임과 전자기기들이 연결되어 있어 영향을 많이 줄 수 있다. 특히, 간접낙뢰 노이즈는 항공 전자기기 오동작 및 손상을 발생시킬 수 있어, 차폐 케이블을 활용하여 간접낙뢰 노이즈로 인한 피해를 줄일 수 있다. 항공기용 차폐 케이블의 차폐층 유무, 내심, 절연체 등의 케이블 구조에 따른 간접낙뢰 영향성 분석을 진행하였다. 또한, 간접낙뢰 공인 규격인 RTCA DO-160G Sec. 22를 적용하여 시뮬레이션 및 실험하여 검증하였다.

해상풍력발전기 직격뢰 보호용 1등급 바리스터 개발 (Development of class I surge protection device for the protection of offshore wind turbines from direct lightning)

  • 이건희;박재현;정경진;강성만;최승규;우정민
    • 풍력에너지저널
    • /
    • 제14권4호
    • /
    • pp.50-56
    • /
    • 2023
  • With the abnormal weather phenomena caused by global warming, the frequency and intensity of lightning strikes are increasing, and lightning accidents are becoming one of the biggest causes of failures and accidents in offshore wind turbines. In order to secure generator operation reliability, effective and practical measures are needed to reduce lightning damage. Because offshore wind turbines are tall structures installed at sea, the possibility of direct lightning strikes is very high compared to other structures, and the role of surge protection devices to minimize damage to the electrical and electronic circuits inside the wind turbine is very important. In this study, a varistor, which is a key element for a class 1 surge protection device for direct lightning protection, was developed. The current density was improved by changing the varistor composition, and the distance between the electrode located on the varistor surface and the edge of the varistor was optimized through a simulation program to improve the fabrication process. Considering the combined effects of heat distribution, electric field distribution, and current density on the optimized varistor surface, silver electrodes were formed with a gap of 0.5 mm. The varistor developed in this study was confirmed to have an energy tolerance of 10/350 ㎲, 50kA, which is a representative direct lightning current waveform, and good protection characteristics with a limiting voltage of 2 kV or less.

Study on Enhancing Lightning Protection Scheme of Catenary in Subway Viaduct Section

  • Li, Rui-Fang;Chen, Kui;Chen, Li-Sheng;Cao, Xiao-Bin;Wu, Guang-Ning;Zhang, Xue-Qin
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권2호
    • /
    • pp.950-958
    • /
    • 2017
  • Viaduct increases the height of subway catenary, namely magnifies lightning attraction scope that lead to higher possibility of suffering lightning stroke. Therefore, it is necessary to analyze performance of lightning striking to catenary of subway in viaduct section and propose an improving lightning protection scheme. In this paper, using ATP-EMTP simulation software to establish an associated model to evaluate lightning withstand level of catenary with existing lightning protection schemes including arrester and grounding point, an improving lightning protection scheme is proposed - every pillar ground earth and arresters are installed with some installing spacing between 200m to 400m based on lightning damage degree and reliability requirements - according to analyzing results: while lightning withstand level is lowest for lightning striking to the neutral pillar, lightning withstand level is greatest for lightning striking to the both-ends pillar that arrester and grounding point are both installed; grounding point could obviously improve lightning withstand level for lightning striking to ground wire while arrester could obviously improve the lightning withstand level for lightning striking to catenary; every pillar ground earth could enhance the lowest lightning withstanding level up to 2.5 times than of that pillar ground earth across every 200m.