• Title/Summary/Keyword: Lightning Discharge

Search Result 90, Processing Time 0.023 seconds

Relief Performance of Fault Current and Design/Manufacturing of Polymer Arresters for Power Distribution (배전선로용 폴리머 피뢰기의 모듈 설계/제조 및 성능)

  • Cho, Han-Goo;Yun, Han-Su;Jang, Tae-Bong;Chie, In-Hyuk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.05b
    • /
    • pp.175-179
    • /
    • 2005
  • The main objective of this paper is to module design and pressure relief test a new type of polymer gapless surge arrester for power distribution line. Metal oxide surge arrester for most electric power system applications, power distribution line and electric train are now being used extensively to protect overvoltage due to lightning. Surge arresters with porcelain housing must not have explosive breakage of the housing to minimize damage to other equipment when subjected to internal high short circuit current. When breakdown of gapless elements in a surge arrester occurs due to flashover, fault short current flows through the arrester and internal pressure of the arrester rises. The pressure rise can usually be limited by fitting a pressure relief diaphragm and transferring the arc from the inside to the outside of the housing. However, there is possibility of porcelain fragmentation caused by the thermal shock, pressure rise, etc. Non-fragmenting of the housing is the most desired way to prevent damage to other equipment. The pressure change which is occurred by flashover become discharge energy. This discharge energy raises to damage arrester housing and arrester housing is dispersed as small fragment. Therefore, the pressure relief design is requested to obstruct housing dispersion.

  • PDF

Characteristics of lightning impulse preliminary breakdown discharge under non-uniform electric field in $SF_6/CO_2$ mixtures (불평등전장에서 $SF_6/CO_2$ 혼합기체의 뇌임펄스 전구방전특성)

  • Lee, B.H.;Oh, S.K.;Baek, Y.H.;Ahn, C.H.;Jeon, D.K.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2140-2142
    • /
    • 2005
  • This paper presents the experimental results on the preliminary breakdown characteristics under a highly non-uniform electric field in $SF_6/CO_2$ gas mixtures. The impulse preliminary breakdown developments are investigated by the measurements of corona current and light emission images. As a result, the preliminary breakdown development mechanisms for both positive and negative polarities are same. The first streamer corona is initiated at the tip of needle electrode, and the leaders develop with a stepwise propagation and bridge the test gap. The pause time of leader pulses in the positive polarity is significantly shorter than that in the negative polarity. Also, the time interval between the first streamer corona onset and breakdown in the negative polarity was much longer than that in the positive polarity The discharge channel paths in the positive polarity were zigzag. On the other hands, the leader channel in the negative polarity was thicker than that in the positive polarity.

  • PDF

The Decreasing of Surge Impedance of Grounding System by using Discharge (지중방전현상에 의한 접지시스템의 써지 임피던스의 저감)

  • 정재기;강지원;양병모;김홍필
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.4
    • /
    • pp.55-61
    • /
    • 1998
  • Generally, in the calculation of ground resistance in the grounding system, the method measuring ground potential rise which is caused by low frequency source injection is used. But both lightning and surge impulse re very harmful to electric equipment. In this connection, this paper presents the results of an experimental investigation of transient behavior of ground impedances when lightening current is injected to the electric rod the experimental results are agreement with the theoretical analysis. In addition, the states on the behavior of ground electrodes under impulse currents due to lighting strokes are presented. And the impulse impedance reductions caused by discharge in the soils are presented.

  • PDF

Experimental investigations of Breakdown Phenomena in Soils in the vicinity of Ground rod (봉형접지전극 주변에서 토중방전현상에 대한 실험적 고찰)

  • Lee, Bok-Hee;Kim, Byoung-Gun;Lee, Woo-Chul
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.279-282
    • /
    • 2005
  • Morden electronic equipments are becoming very important in information oriented society, but they are vulnerable to lightning surges. Soil resistivity in the vicinity of grounding electrodes my be affected by the current flowing from the grounding electrodes into the surrounding soil. Electrical conduction in soils depends on the grain size, compactness, and variability of the grain sizes. When a high current is injected into the soil, and the breakdown phenomenon occur. In the present work, Electrical behaviors related to discharge in soils were investigated. The breakdown voltages in soil were lower than that sparkover voltage in air. The breakdown voltage in the gravel layer is relatively low, and the breakdown was caused by the flashover through the surface of gravels

  • PDF

Restudy of Fault Current Distribution Ratio with Grounding Type of Normal Joint Box in Underground Transmission Systems (지중송전계통에서 보통접속함의 접지방식에 따른 고장전류분류율 재검토)

  • Hong, D.S.;Kang, J.W.;Jang, T.I.;Kim, H.H.;Yoon, H.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.500-502
    • /
    • 2002
  • Receltly, Underground transmission system is getting increased. Therefore the design of grounding system becomes very important to discharge overcurrent of lightning and fault through earth and reduce sheath induced voltage and sheath circulation current. This paper describes fault current distribution ratio for grounding line with grounding types of normal joint box and sheath grounding resistor at line-to-ground fault of cable.

  • PDF

Dielectric Characteristics of $SF_6/N_2$ Mixture Insulation Gas for HV GIL (초고압 GIL을 위한 $SF_6/N_2$ 혼합가스의 절연특성)

  • Chang, Yong-Moo;Kim, Chul-Ho;Kim, Jeong-Tae;Koo, Ja-Yoon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.49-49
    • /
    • 2010
  • In this paper, a full scaled gas discharge chamber was designed and fabricated for evaluating the dielectric performance of SF6/N2 mixture gases. And it describes work on AC and lightning impulse dielectric characteristics of SF6/N2 mixture insulation gas from experiments and full scale models.

  • PDF

Optimization of DC Operating Voltage for GDT-Adopted SPD (가스방전관(GDT)을 적용한 서지보호장치 회로의 DC 동작전압 최적조건 고찰)

  • Choi, Jong-Min;Jeon, Tae-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.7
    • /
    • pp.92-98
    • /
    • 2012
  • It is made compulsory to install SPD for the purpose of protecting electric and electronic devices when an abnormal voltage such as lightning occurs to power line using power frequency of 60Hz. Recently, the high speed communication technology utilizing power line is receiving attention again as a communication technology for smart grid. The SPD influences the performances of power line communication when using SPD and power line communication system together. In order to improve the performance of power line communication, a proposed scheme for series connection of gas discharge tube to ZnO varistor was presented. This paper measured the impacts of series connection of GDT to SPD using ZnO varistor on the limit voltage of Class III SPD. This paper also presented the DC operating voltage of GDT which satisfies the limit voltage of power line communication system and SPD simultaneously.

Transient Ground Impedance of Small-sized Needle-rod Electrodes due to Underground Soil Discharge (토양의 지중방전에 따른 소형 침봉전극의 과도접지임피던스)

  • Lee, Tae-Hyung;Cho, Sung-Chul;Eom, Ju-Hong;Lee, Bok-Hee
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.211-215
    • /
    • 2008
  • This paper deals with the transient ground impedance of small-sized needle-rod installed in a test field, Impulse voltage generator was used to inject lightning impulse on a ground electrode and modified fall-of potential method was proposed to measure the high ground potential rise. Transient ground impedance was analysed with impedance curve and I-V curve as respects the resistivity of soil. Soil ionization near the ground electrode is activated in high resistivity soil and have an effect on the reduction of transient ground impedance significantly.

  • PDF

The Electrical and Transient Thermal characteristics of TVS diode for Surge Absorber (TVS 다이오드의 전기적 특성 및 과도 열방출 특성 해석)

  • Kim, Sang-Cheol;Kim, Hyung-Woo;Kim, Eun-Dong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05c
    • /
    • pp.208-212
    • /
    • 2003
  • Silicon transient voltage suppressors (TVSs) are clamping devices that limit voltage spikes by low impedance avalanche breakdown of a rugged silicon PN junction. They are used to protect sensitive components from electrical overstress such as that caused by induces lightning, inductive load switching and electrostatic discharge. In this paper, we present static and dynamic characteristics of TVS diode using thermal analysis simulation software. And also, it is presented that the thermal dissipation characteristics of TVS diode in the transient state.

  • PDF

A Study On the Impulse Response Behavior of Ground Rods in Power Distribution System (22.9kV-Y 다중접지 배전계통 접지극의 임펄스 응답 특성 실증연구)

  • Kang, Moon-Ho;Jang, Sang-Ok;Park, Sang-Man;Ha, Dong-Hyuk;Lee, Heung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1858-1860
    • /
    • 2003
  • Ground rods as the discharge path are commonly installed to ensure the safety of human beings and facilities from the surge. Accordingly, proper grounding resistance are specified by the grounding types, and the specified resistance are also required to install the lightning protective facilities. it is needed to analyze the difference between these two resistance through the field test. Therefore, in this paper, the impulse response behavior of the ground rods is analyzed by constructing the test facilities and by testing the ground rods in multi-ground power distribution systems. The impulse responses were analyzed, in transient state, by testing the concrete poles as well since the grounding wires are installed in the concrete poles.

  • PDF