• Title/Summary/Keyword: Lightning Detection

Search Result 39, Processing Time 0.034 seconds

Lightning observation by KLDNet and analysis on lightning activities of Korea in 2007 (한전낙뢰감지네트워크(KLDNet)에 의한 우리나라의 2007년도 낙뢰측정 및 분석)

  • Kwak, Joo-Sik;Kang, Yweon-Woog;Woo, Jung-Woog;Koo, Kyo-Sun;Kweon, Dong-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.438-439
    • /
    • 2008
  • KEPCO has been operating a lightning detection network, KLDNet, to cope with lightning-induced faults. An weather observation for last 40 years shows that heavy rainy days per year and the strength of rain have almost doubled. It could be interpreted as more frequent occurrence of lightning events. In accordance with that, the lightning activities and the mischievous influences, such as transmission faults, have increased. In this paper, the observed data by the network in 2007 is analyzed and compared with ten-years-old-statistics accumulated by the former system, LPATS.

  • PDF

Development of Wireless lightning detecting and warning system (무선식 낙뢰통보시스템 개발)

  • Kim, Kyung-Man;Kwon, Tae-Woon;Sim, Kwang-Yeol;Kim, Se-Yeol
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.500-503
    • /
    • 2006
  • This paper gives a Wireless lightning detecting and warning system. This system composed of transmitter and receiver. It promptly senses lightning strikes on the power lines and transmission towers by using the lightning current detection circuit in a small transmitter situated on the top of power tower, and it sends the number of lightning strikes and the ID. of the tower to patrols through the receivers. This system will be used to discover the exact location of a lightning strike.

  • PDF

Analysis on the Lighting Characteristics using KLDNet in Korea (낙뢰감지 네트워크를 이용한 한반도 낙뢰특성 분석)

  • Woo, Jung-Wook;Kwak, Joo-Sik;Koo, Kyo-Sun;Kim, Kyung-Tak;Kweon, Dong-Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.9
    • /
    • pp.117-123
    • /
    • 2009
  • Recently, the failures of electrical equipment have been reduced due to the improvement of its quality and the advance of operation techniques but the failure rates caused by natural disasters such as wind and lightning have been increased. To reduce the failures due to lightning, it is necessary for insulation design of transmission lines to be done, effectively. Also the analysis on the lightning characteristics is essential to the effective insulation design. In this paper, we describe lightning distribution, multiplicity, IKL(Iso-Keraunic Level) and amplitude distribution of lightning current base on the lightning data by KLDNet.

A Study on the 3D Characteristics of Lightning in KOREA (한반도내 낙뢰의 3차원 특성에 관한 연구)

  • Woo, J.W.;Kwak, J.S.;Kang, Y.W.;Kwon, D.J.;Moon, J.D.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1556-1557
    • /
    • 2006
  • Since 1996, KEPCO has been operating a wide range lightning detection system, LPATS, and been accumulating relative application technics and statistical analysis skills. So, KEPRI already has its own basis to develope more accurate advanced detection technology and references to do comparative study. For Three-dimensional imaging of lightning channels, UHF/VHF antenna systems were installed at 2 sites. The distance between two sites is about 30 km. In this paper, we would like to introduce about our system and its results.

  • PDF

OPERATION OF LIGHTNING DETECTION NETWORK IN KOREA (국내의 낙뢰 위치 표정 시스템 운용 현황)

  • Wee, S.B.;Bae, J.H.;Cho, Y.G.;Kim, Y.S.;Kim, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.186-188
    • /
    • 1993
  • This paper reports a status of KLDN(Korean Lightning Detection Network) SYSTEM in Korea, which was constructed by KMA(Korean Meteorological Administration) & KERI(Korean Electrotechnology Research Institute). At first, system configuration was introduced, and then lightning location data between August/1992 & April/1993, which was obtained in KLDN SYSTEM, was analyzed statistically. Finally, we show the future research planning in relation with this KLDN SYSTEM.

  • PDF

A Proposal on the Development Method of a New Lightning Warning System for Effective Alerts (유효 경보를 위한 새로운 낙뢰 경보시스템의 개발 방법에 대한 제안)

  • Shim, Hae-Sup;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.12
    • /
    • pp.68-76
    • /
    • 2015
  • We examine the standalone lightning warning system (LWS) and its warning performances for three years. This system acquires and analyzes the data of cloud-to-ground strike (CG), intra-cloud discharge (IC) and electrostatic field (EF) to produce prior warnings with respect to the impending arrival of CG in the area of concern (AOC). The warnings in this system are carried out based on the fixed two areas method. To evaluate warning performances, we analyzed the statistics of warnings with probability of detection (POD) and false alarm ratio (FAR). Based on the previous study, we revised the trigger and clear conditions of lightning warning for improving the performances of the system. As a result of this revision, POD increased from 0.18 to 0.44 and FAR decreased from 0.96 to 0.78 during the summer of 2014. However, the LWS was not possible to trigger effective alerts (EA) because there was no effective lead time (LT) for the fixed two areas method. Problems related to the low detection efficiency of IC and the use of EF data for warnings still decreased POD and increased FAR. Hence, we proposed the development method of a new LWS (NLWS) that would be composed of integrated weather data, the flexible two areas and the user software in order to trigger EA and improve warning performances.

Characteristics by the Cloud-to-Ground Lightning Polarity Occurred over South Korea (남한 지역에서 발생한 구름-지면 낙뢰의 극성별 특성)

  • Myoung, Ji-Su;Suh, Myoung-Seok
    • Journal of the Korean earth science society
    • /
    • v.31 no.4
    • /
    • pp.335-347
    • /
    • 2010
  • The statistical characteristics of Cloud-to-Ground (CG) lightning data, observed by the total lightning detection system (TLDS) of KMA during the recent seven years (2002-2008), have been analyzed. Lightning frequency shows a strong interannual, seasonal and diurnal variations without regard to the polarity. The 74% and 0.6% of the total lightning occurred during the summer and winter, respectively. And it has a bimodal diurnal variation with two peaks (dawn: 0500-0700 LST, mid-afternoon: 1500-1600 LST). The ratio of positive flashes to negative ones also has a strong seasonal variation with the maximum and minimum during winter (62.5%) and summer (7.3%), respectively. Unlike the lightning frequency, the lightning intensity of negative flashes shows a weak interannual, seasonal and diurnal variations. However, the lightning intensity of positive flashes exhibits an inverse seasonal variation to that of lightning frequency, with the minimum and maximum during summer and winter, respectively. The lightning density is greatly higher in the western inland areas and the West/South Sea than in the eastern part and the East Sea. In general, the lightning intensity is stronger in the ocean, especially in the East Sea than in the inland area, regardless of the polarity.

A Study of AM Broadcasting Antenna's Lightnning and Ground System (AM방송안테나의 낙뢰와 접지에 관한 연구)

  • 이문호
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.4 no.1
    • /
    • pp.43-46
    • /
    • 1979
  • The lightning which is occurred in different regions Contains 80% of whole between June and September. There were the lightning accidents at the peak of mountains. As a result, the antenna tower of AM broadcasting Systems build up clyish plain where has a low earth characteristics resistivity. The following have been observed as a Counter lightning Systems such as high frequency choke, sphere gap(75, 000 V/inch) and reflective power detection relay.

  • PDF

Development of a Ubiquitous Sensor for Monitoring Insulators and Lightning Arresters (애자/피뢰기 모니터링을 위한 유비쿼터스 센서 개발)

  • Kil, Gyung-Suk;Rhyu, Keel-Soo;Song, Jae-Yong;Kim, Il-Kwon;Park, Dae-Won;Choi, Soo-Yeon
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.2 s.39
    • /
    • pp.117-123
    • /
    • 2007
  • In this study, a ubiquitous sensor for condition monitoring of insulators and lightning arresters installed in power distribution lines and electric traction vehicles is presented. The sensor consists of two parts; a leakage current measurement and a lightning surge detection. Measured data are transmitted to a supervisory computer through ZigBee protocol based on IEEE 802.15.4. To detect leakage current, a window type Mn-ZCT is used and a low-noise amplifier with a gain of 60dB is designed, and this can measure leakage current in ranges of $100{\mu}A{\sim}5mA$. A sample-hold (S/H) and a Rogowski coil are injected to analyze the magnitude of surge current in ranges from 100A to 10kA with $8/20{\mu}s$-waveform.

A Study on the Development of a Remote Monitoring Equipment for Ground Fault Current by Lightning Strike (낙뢰에 의한 지락전류 원격 감시장치에 관한 연구)

  • Pyo, Se Young;Kim, Tag Yong;Kim, Kee Hwan
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.4
    • /
    • pp.783-788
    • /
    • 2020
  • Surges generated by direct strike or induction of lightning, frequent opening and closing of power system breakers, etc. cause excessive overvoltage, which can interfere with normal operation of transformers, circuit breakers, and power equipment. In order to prevent such phenomena, this study goes further from the method of establishing countermeasures by installing lightning arresters on power equipment or lines in parallel, and furthermore, remotely checking the condition of the lightning arrester and preparing immediate countermeasures when an event occurs. The purpose of the study is to prevent damage in advance.