• 제목/요약/키워드: Lightning Current

검색결과 313건 처리시간 0.031초

$SF_6$ 가스중에서 침대평판간극(針對平板間隙)의 전구(前驅)코로나 방전(放電) (Prebreakdown Corona Discharge of Point-to-Plane Gap in $SF_6$ Gas)

  • 백용현;이복희;전덕규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.980-982
    • /
    • 1992
  • This paper deals with the dielectric behaviors of $SF_6$ gas and prebreakdown growth caused by lightning impulse voltages In inhomogeneous field perturbed with a fixed needle-shaped protrusion on the electrode. The measuring interpretation of the external current induced by moving charges is described. The temporal growth of prebreakdown is observed by using a shunt and photomultiplier. The prebreakdown processes are initiated by the first streamer corona at a needle protrusion, the flashover of the main gap in the positive polarity is very sensitive to the local field and propagates into the gap with the leader mechanism. It Is found that the dependence of the prebreakdown phenomena on the polarity of applied voltages is caused by the effect of space charges. In addition, the proposed measuring techniques are very useful to perform the measurements of avalanche currents, corona discharges in inhomogeneous fields and partial discharges in voids.

  • PDF

접지전극의 형상에 따른 과도접지임피던스 (Transient Ground Impedances According to Shapes of Grounding Electrodes)

  • 이복희;이수봉;이태형;정현욱;정동철
    • 조명전기설비학회논문지
    • /
    • 제20권1호
    • /
    • pp.65-70
    • /
    • 2006
  • 본 논문은 임펄스전류에 따른 접지시스템의 과도 특성에 관한 것으로 임펄스 전류를 심매설 봉상 접지전극과 그리드 접지전극에 인가하였을 때 나타나는 과도접지임피던스를 조사하였다. 과도접지임피던스는 인가전류의 상승시간과 접지전극의 크기 및 형태에 강하게 의존하며, 접지전극의 인덕턴스는 짧은 시간 영역에서 접지시스템의 과도 접지임피던스에 크게 영향을 미치는 것으로 나타났다. 또한 심매설 봉상접지전극은 짧은 시간영역에서 과도접지임피던스를 줄이는데 효과적이었다.

조명기기의 임펄스내전압 성능의 분석 (Analysis of Impulse Withstand Voltage Performance of Lighting Equipment)

  • 이복희;방평호
    • 조명전기설비학회논문지
    • /
    • 제28권3호
    • /
    • pp.91-96
    • /
    • 2014
  • Modern electronic circuits are becoming more vulnerable to damage by surges, and it is required to improve the impulse withstand voltage performance of electrical and electronic equipment. This paper presents the impulse withstand voltage performance of lighting equipment connected to power lines, and the impulse withstand voltage tests for fluorescent lamp, LED lamp and halogen lamp were carried out according to the reference standards under normal service conditions. To conduct performance tests against lightning surge, a combination wave ($1.2/50{\mu}s$ voltage - $8/20{\mu}s$ current) was employed. The test surge was applied between lines or between line and ground of the specimen to be measured. The test surge was applied synchronized at the peak value of the positive and negative AC voltage waves. As a consequence, some specimens satisfied the impulse withstand voltage test criteria, but lighting equipment such as 36W fluorescent lamps, 5W and 5.5W LED lamps and 50W halogen lamp were damaged at the test voltage levels between power lines. It is needed to improve the qualities of lighting equipment to satisfy EMC immunity requirements of equipment for general lighting purposes.

항공기 낙뢰 간접영향 인증시험 동향

  • 한상호;서장원
    • 항공우주산업기술동향
    • /
    • 제5권2호
    • /
    • pp.87-97
    • /
    • 2007
  • 오늘날 항공기 설계와 제작은 다국적인 산업의 형태로 이루어지고 있다. 즉 항공기 서브시스템은 세계 각국에서 독립적으로 설계, 제작 및 시험한 후 한 곳으로 납품되어 조립 제작되는 데 이 때 중요한 것이 표준화이다. 항공전자장비의 낙뢰 간접영향에 대한 인증의 경우 RTCA DO-160E, Section 22 Lightning Induced Transient Susceptibility(낙뢰 유도 과도현상 적응성)로 표준화 되어 있다. 이 Section 22는 낙뢰 간접영향에 대한 항공전자장비 단위 즉, LRU (Line Replaceable Units)와 같은 부품단위의 시험 요건을 규정하고 있으며 이 규격은 현재 전 세계적으로 통용이 되고 있다. 1980년대 초 상용 수송기에 디지털 "Fly by Wire" 비행 시스템과 엔진제어시스템(EEC, Electronic Engine Control)의 도입 이후, 항공기 시스템이 낙뢰 환경에서 운용시 신뢰성을 보증할 필요성이 대두되었다. 데이터 처리를 통하여 제어되는 각종 항공전자장비에는 다중타격(MS)과 다중파열(MB) 기법에 의한 시험 사항이 최근 추가 되었다. 실제 낙뢰 환경과 유사한 시험실 모사를 위해 계속적인 연구가 진행 중이며 신규 시험 규격서가 새로이 출간되고 있다.

  • PDF

CATV 전송선로의 간섭을 줄이기 위한 접지방식에 관한 연구 (A study on the Grounding method for reduce an interference by CATV Transmission Line)

  • 황종선;연제진;박성진;김영민
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집 Vol.14 No.1
    • /
    • pp.57-60
    • /
    • 2001
  • CATV is the abbreviation for Cable Television. General CATV is a way of multi-channel sending images, voices and music including stillness image as well as characters to public receivers through electrical cable communication system. In the beginning, master antennas were people can not receive TV signal well. TV programs were received from master antennas to TVs in each house. Ground connection began by experimenting lightning with the use of a kite and it means electric appliances, communication equipments, measuring instruments and so on connecting the Earth in order to flow away overcharged electricity. There are two kinds of earth connection: Power Ground and Signal Ground. Power Ground is for preventing an electric shock and in general there's no current in the connector. However in an accident, there's a quick flow of electricity out to the Earth. Signal Ground is not only for the safety of appliances but also for the safety of equipment operation. This paper is about connection for noise and interference reduce in order to prevent wrong operation and distortion of signal in the electrical appliances which can take place in CATV.

  • PDF

임펄스전압에 대한 누전차단기의 부동작 특성 (Dead Operation Characteristics of Earth Leakage Circuit Breaker Caused by Impulse Voltages)

  • 이복희;장석훈;이승칠
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 E
    • /
    • pp.1715-1717
    • /
    • 1997
  • This paper deals with the dead operation characteristics of the earth leakage circuit breaker(ELB) caused by impulse voltages. The surge protective devices for electronic circuit and AC power lines are becoming more widely used. It is possible to give rise to the malfunction of ELB due to the operation of surge protective devices, and the interruption of AC power lines brings about several disadvantages such as low reliability of electronic and informational systems, economical loss, and etc. The dead operation characteristics of the ELB from impulse voltages were measured under the conditions of KS C 4613 and the test circuit with a varistor. As a result, the peak current value of the zero-phase sequence circuit of the ELB is increased as the surge voltage and stray capacitance increase. All of the ELBs used in this work were satisfied with the lightning impulse dead operation test condition defined in KS C 4613. However one specimen only did not cause dead operation in the condition of the test circuit with a varistor. There is high possibility that a large portion of the ELBs connected with the AC power lines having the surge protective devices bring about the dead operation.

  • PDF

임펄스전압에 의한 토양의 이온화에 따른 접지성능의 향상 (Improvements of Grounding Performances Associated with Soil Ionization under Impulse Voltages)

  • 김회구;이복희
    • 전기학회논문지
    • /
    • 제65권12호
    • /
    • pp.1971-1978
    • /
    • 2016
  • In this paper, electrical and physical characteristics associated with the ionization growth of soil under impulse voltages in a coaxial cylindrical electrode system to simulate a horizontally-buried ground electrode were experimentally investigated. The results were summarized as follows: Transient ground resistances decreased significantly by soil ionization. The voltage-current (V-I) curves for non-ionization in soil lined up in a straight line with the nearly same slope that is the ground resistance, but they showed a 'cross-closed loop' of ${\infty}$-shape under ionization. The conventional ground resistance and equivalent soil resistivity were inversely proportional to the peak value of injected impulse currents. On the other hand, the equivalent ionization radius and time-lag to the maximum value of ionization radius were increased with increasing the incident impulse voltages. An analysis method for the transient ground resistances of the ground electrode based on the ionization phenomena was proposed. The proposed method can be applied to analyze the transient performances of grounding systems for lightning protection in power system installations.

국제규격 대응 컴퓨터 네트워크용 서지방호장치 개발에 관한 연구 (A Study on the Surge Protection Device for Computer Networks by International Standards)

  • 박대원;서황동;송재용;한주섭;길경석
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2005년도 춘계종합학술대회
    • /
    • pp.277-280
    • /
    • 2005
  • This paper dealt with the development of a surge protection device (SPD) that can protect high speed computer network devices from overvoltages caused by switching operations or lightning surges. The designed SPD is a form of hybrid circuit which is composed of a gas tube having large current diverting capability, high response bi-directional avalanche diodes, and fast recovery diodes to reduce insertion loss on high frequency domain. Surge protection and signal transmission characteristics of the fabricated SPD was tested according to the international standards, IEC 61000-4-5 and IEC 61643-21. From the test results, the SPD is satisfied with the international standards and the high cut-off frequency was 204MHz. Also, the SPD showed a good performance without an insertion loss on a field test of 100Mbps class Local Area Network

  • PDF

CATV 전송선로의 간섭을 줄이기 위한 접지방식에 관한 연구 (A study on the Grounding method for reduce an interference by CATV Transmission Line)

  • 황종선;연제진;박성진;김영민
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.57-60
    • /
    • 2001
  • CATV is the abbreviation for Cable Television. General CATV is a way of multi-channel sending images, voices and music including stillness image as well as characters to public receivers through electrical cable communication system. In the beginning, master antennas were people can not receive TV signal well. TV programs were received from master antennas to TVs in each house. Ground connection began by experimenting lightning with the use of a kite and it means electric appliances, communication equipments, measuring instruments and so on connecting the Earth in order to flow away overcharged electricity. There are two kinds of earth connection: Power Ground and Signal Ground. Power Ground is for preventing an electric shock and in general there's no current in the connector. However in an accident, there's a quick flow of electricity out to the Earth. Signal Ground is not only for the safety of appliances but also for the safety of equipment operation. This paper is about connection for noise and interference reduce in order to prevent wrong operation and distortion of signal in the electrical appliances which can take place in CATV.

  • PDF

직류전동차 탑재용 피뢰기의 최적선정에 관한 연구 (A Study on the Best Selection of Lightning Arrester for DC Electric Traction Vehicles)

  • 차명수;송재용;김일권;길경석;이대성;박재규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1519-1520
    • /
    • 2006
  • This paper describes a selection and application recommendations of ZnO arresters on DC electric traction vehicles. We measured and analyzed the system voltages applied to arresters and the surge currents flowing arresters on DC electric traction vehicles under operation to decide the Continuous Operating Voltage($U_C$), the Rated Voltage($U_R$), and the Nominal Discharge Current($I_n$). System voltages measured up to 1,800 V during anti-breaking in 1,500 V-system, and surge currents were recorded up to 3 times per running-service-route and their magnitudes were ranges of $150A{\sim}2kA$. From these results and the standard EN50163, we proposed the Continuous Operating Voltage($U_C$) the Rated Voltage($U_R$) for the $1,500V_{dc}$ electric traction vehicles.

  • PDF