• Title/Summary/Keyword: Lighting measurement

Search Result 240, Processing Time 0.033 seconds

Effect of Lighting Saving Using High Efficiency Reflector (고효율 반사갓을 이용한 등기구 저감효과)

  • Cho, Huyn-Kyung;Kim, Jae-Chul;Jung, Seung-Bock;Im, Sang-Kug
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.148-153
    • /
    • 2006
  • This paper analyzes the effect of the energy saving and evaluates the economics using High Efficiency lighting. About 18 percent (17,000GWh) of total power demands in Korea m consumed i]l the lighting field. There isa lot of energy potential that can be saved because the power demand isolwer relatively than the others parts. The existing lighting that its length and electric energy are 32[mm] and 40[w] can alternate with high efficiency lighting which its length and electric energy are 26[mm] and 32[w]. Two Lightings is measuring the illumination and the electric energy and then are analyzed into the effect of the lighting saving by measurement.

  • PDF

A Study on the Subjective Evaluation of Color Appearance under the Different LED CCT Conditions (색온도별 LED 조명에 의한 색상별 색보임에 대한 주관평가 연구)

  • Kim, Hyun-Sun;Kim, Yu-Sin;Choi, An-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.2
    • /
    • pp.43-52
    • /
    • 2011
  • LED lighting may cause different sensation and color appearance due to the different spectral power distributions compared to those of conventional lightings. Particularly, the CCT (Correlated Color Temperature) of LED lighting has a major effect on color appearance so that this study conducted an experiment through a subjective evaluation and luminance measurement for effective color appearance in a space. This study performed a subjective evaluation under the seven different LED CCT conditions, and color appearance was evaluated with major five colors in a customized lighting box. In addition, luminance measurement was conducted for each CCT and color condition to compare the results from a subjective evaluation. The results of this study may help to select a proper LED CCT for specific color conditions.

Position Measurement Using Enclosed Signal Field with Pulse-Width-Modulated function

  • Ohyama, Shinji;Iizuka, Junya;Kobayashi, Akira
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.455-455
    • /
    • 2000
  • A novel pulse-width-modulated (PWM) function is introduced for precise position measurement in an enclosed signal field. An amplitude modulation was used to light the LEDs for the conventional study. However, the transform properties from the driving signal to the lighting intensities of the LEDs are non-linear, and accurate control of the lighting power was necessary. Therefore, a lighting function independent of these properties is desired. Well-known PWM functions are used to construct the enclosed signal field by simulation, and the precision of the phase detecting system is analyzed. A novel "axial symmetry PWM" function is found to be effective for orthogonal pahse detection.

  • PDF

Manufacturing of Cs3Sb Photocathode in Atmospheric Conditions

  • Jeong, Hyo-Soo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.10
    • /
    • pp.653-656
    • /
    • 2014
  • $Cs_3Sb$ photocathode was formed by newly developed process and successive in-situ lighting devices were fabricated in a process chamber. R, G, and B phosphors were applied on the anode plate, respectively. Major parameters such as brightness, power consumption, and efficacy were measured. The wavelength of LED excitation source was 450 nm. Both high power and low power modes were applied in the measurement. Measurement values were clearly differentiated by the voltage application modes. The measured values of each parameter was good enough to be applied for general lighting source. The results showed that $Cs_3Sb$ photocathode formed in atmospheric conditions was functioning as good as the photocathode formed in UHV conditions, and thus it could be applied to advanced lighting devices.

Measurement System of Photosynthetic Photon Flux Distribution and Illumination Efficiency of LED Lamps for Plant Growth

  • Lee, Jae Su;Kim, Yong Hyeon
    • Journal of Biosystems Engineering
    • /
    • v.37 no.5
    • /
    • pp.314-318
    • /
    • 2012
  • Purpose: This study was conducted to develop a measurement system for determining photosynthetic photon flux (PPF) distribution and illumination efficiency of LED lamps. Methods: The system was composed of a linear moving sensor part (LMSP), a rotating part to turn the LMSP, a body assembly to support the rotating part, and a motor controller. The average PPF of the LED lamp with natural cooling and water cooling was evaluated using the measurement system. Results: The PPF of LED lamp with water cooling was 3.1-31.7% greater than that with natural cooling. Based on the measured value, PPF on the horizontal surface was predicted. Illumination efficiency of the LED lamp was slightly increased with water cooling by 3.4%, compared with natural cooling. A simulation program using MATLAB was developed to analyze the effects of the vertical distance from lighting sources to growing bed, lamp spacing, and number of LED lamps, on the PPF distribution on the horizontal surface. The uniformity of the PPF distribution of the LED lamps was fairly improved with 15 cm spacing, as compared to the 5 cm spacing. By simulation, PPF of $217.0{\pm}27.9{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ was obtained at the vertical distance of 40 cm from six LED lamps with 12 cm spacing. This simulated PPF was compared to the measured one of $225.9{\pm}25.6{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$. After continuous lighting of 346 days, the relative PPF of LED lamps with water cooling and natural cooling was decreased by 6.6% and 22.8%, respectively. Conclusions: From these results, it was concluded that the measurement system developed in this study was useful for determining PPF and illumination efficiency of artificial lighting sources including LED lamp.

Development of Methodology of Lighting Plan for Elderly Housing (고령자를 위한 주거시설 조명환경 계획에 관한 연구)

  • Won, Seul-Ki;Park, Byoung-Chul;Choi, An-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.6
    • /
    • pp.8-18
    • /
    • 2007
  • The number of people over sixty five years old is steadily rising and the elderly housing we continuously increasing. Regarding such a trend this research has been focused to propose the methodology of lighting design for elderly people. For this purpose, we researched the basic theory of lighting design through literature review, first. In addition, measurement and analysis of the light environment and light plan in elderly housing has been carried out by case studies. And we organized lighting scenario by the daily life-pattern of the elderly, and than planned lighting interface to be easy to control.

A Study on Maintenance Planning for Efficient Urban Lighting in Wonju-si (원주시의 효율적인 도시조명을 위한 관리 계획에 관한 연구)

  • Lee, Yeon-So;Woo, Soo-Jin;Choi, Key-Soo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.4
    • /
    • pp.7-15
    • /
    • 2011
  • Based on the master plan, this study classified Wonju-si into five major regions and 19 areas by analyzing its night characteristics and deduced problems by analyzing quantitative light distribution of major points at the regions and areas through the measurement of illuminance and luminance and by surveying people's awareness. To develop eco-friendly night environment image of Wonju, Woju's identify was to be created by the planning for the 19 area and improvements for each type. Additionally, detailed items for maintenance were suggested by classifying them into illuminance, color temperature, luminance, lighting display, lighting time, light distribution type, and so forth.

A study of luminance and light appearance measurement for Han River Bridge's flood lighting (한강교량 경관조명 휘도 및 광색 측정조사 연구)

  • Lee, Wan-Soo;Yeo, Seung-Min;Lee, Jang-Hee;Park, Eun-Kyung;Shim, Seung-Youn;Chung, Kang-Wha
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.111-116
    • /
    • 2005
  • This study examined the luminance and light appearance about 14 flood lighting established bridges of 26 Han River bridges and then analyzed the result through questionnaire and so on. Through this result, we looked out for new direction of analysis research for flood lighting that consider the problem of optimum brightness and light appearance harmony at flood lighting presentation, proposed to be utilized concretely in lighting design guideline for Han River bridge.

  • PDF

A Correlation Analysis between DSC (Dye Sensitized Cell) and Daylighting-Focusing on Educational Space (염료감응형 태양전지(DSC)와 자연채광의 상관관계 분석-교육공간을 중심으로)

  • Lee, Eung-Jik
    • Journal of the Korean Solar Energy Society
    • /
    • v.40 no.1
    • /
    • pp.35-47
    • /
    • 2020
  • Due to the large window area, the lighting environment of the educational space between the window and deep part of the room is not uniformly illuminated, and the phenomenon of glare is severe. For this reason, the daylight performance of DSC-BIPV windows was analyzed in order to improve the natural lighting in the educational sector. The method derives the correlation with natural lighting by measurement and simulation. Dynamic simulation confirmed that the average illuminance of the target space was higher at later than the early afternoon. The performance of natural lighting at 40% and 30% transmission of DSC has the effect of significantly reducing the amount of excess light in existing windows. Nevertheless, the actual average illuminance in all seasons corresponds to the standard illuminance of the educational facility, 300 Lux. In addition, the uniformity is also seen through the skylight illuminance ratio.