Parameter estimation of the Diffusion Model for Demand Side Management Monitoring System (DSM Monitoring을 위한 확산 모델의 계수 추정)

  • Choi, Cheong-Hun;Jeong, Hyun-Su;Kim, Jin-O
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1073-1075
    • /
    • 1998
  • This paper presents the method of parameter estimation of diffusion model for monitoring Demand-Side Management Program. Bass diffusion model was applied in this paper, which has different values according to parameters ; coefficients of innovation, imitation and potential adopters. Though it is very important to estimate three parameter, there are no empirical results in practice. Thus, this paper presents the method of parameter estimation in case of few data with constraints to reduce the possibility of bad estimation. The constraints are empirical results or expert's decision. Case studies show the diffusion curves of high-efficient lighting and also forecasting of the peak value for power demand considering diffusion of high-efficient lighting, the feedback and least-square parameter estimation method used in this paper enable us to evaluate the status and forecasting of the effect of DSM program.

  • PDF

A Study on the Evaluation of Lighting Performance in an Office Space (사무공간의 조명성능 평가에 관한 연구)

  • 김한성;김영민;김강수
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.6
    • /
    • pp.16-22
    • /
    • 2003
  • The purpose of this study was to provide visual evaluation data in a workstation space when different lighting types were applied. For the performance evaluation, Radiance program was used for simulations, and the mock-up room(15.0x11.6x3m) was used for the actual test. The results of this study were as follows; 1) When the inidirect lighting simulation data using Radiance was compared with the actual data in a small workstation space, there was a 6.5% difference. Therefore, Radiance program was proved to be useful for the evaluation of lighting performance. 2) Higher light levels (higher light ratio (%)) were recorded in the straddled layout and lower light levels (lower light ratio (%)) were recorded in the centered layout condition in most cases. 3) Also, the results show that the indirect luminaires and the straddled layouts provide higher uniformity, whereas the direct luminaires and the centered layouts have lower uniformity.

Modeling and Optical Characteristics of LED-Lighting Adopting Aspherical Lens

  • Lee, Hak-Suk;Park, Jong-Rak;Kim, Min-Jae;Kim, Hye-Jung;Kim, Jung-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.19-19
    • /
    • 2009
  • Recently, Light Emitting Diode(LED) has many advantages in comparison with conventional light sources; low power consumption, long lifetime, and less environmental pollution. Therefore, the use of LED is multiplying and increasing rapidly. In general, however, spherical lens is used in LED-lighting which cause many problems induces by optical aberration of spherical lens; low illumination, a yellow belt, unpleasant feeling in human eye. As a potential solution of this problem, aspherical lens can be employed. This study reports the improvement of LED-lighting performance by adopting aspherical lens. From the commercial program, $LightTools^{TM}$, the optical problem were ensured. And then, to improve this problem, optimum aspheric form was designed using Code $V^{TM}$.

  • PDF

A Study on Optical Efficiency Improvement of LED-lighting Adopting Aspherical Optical System(I) (비구면 광학계를 적용한 LED 조명의 광학성능 향상에 관한 연구(I))

  • Lee, Hak-Suk;Park, Jong-Rak;Kim, Min-Jae;Kim, Hye-Jeong;Kim, Jeong-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.12
    • /
    • pp.1033-1038
    • /
    • 2009
  • Recently, Light Emitting Diode (LED) has many advantages in comparison with conventional light sources; low power consumption, long lifetime, and less environmental pollution. Therefore, the use of LED is increasing rapidly. In general, however, spherical lens is used in LED-lighting which cause many problems induces by optical aberration of spherical lens; low illumination, yellow belt, unpleasant feeling in human eye. As a solution of these problem, aspherical lens can be employed. This study reported the improvement of LED-lighting performance by adopting aspherical lens. From the commercial program, $LightTools^{TM}$, the optical problem were ensured. And then, to improve these problem, optimum aspheric form was designed using Code $V^{TM}$.

A Study on the Limit Analysis of the LED Lighting Subsidy Program Considering the Perspective of Individual Building Clients (건축주 입장을 고려한 LED조명 프로그램의 한계 분석 연구)

  • Hwang, Sung-Wook;Park, Jung-Sung;Chae, Woo-Kyu;Lee, Hak-Ju;Song, Il-Keun;Kim, Jung-Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.5
    • /
    • pp.18-25
    • /
    • 2013
  • Various DSM (Demand Side Management) programs have been developed and carried out to use the limited energy resources of human-beings reasonably. LED lighting is one of essential DSM programs and the development of technologies is ongoing vigorously. Recently, one-person households have been increased and the electricity consumption pattern is different with conventional households because residents live as a single. On the other hand, owners of the one-person households tend to not prefer to install high efficient appliances due to the cost increasement. Therefore, the existing DSM subsidy programs should be revaluated so that the owners decide to install high efficient appliances.

A Study on a Novel LED Lighting Fixture for Crosswalk Having Two Different Light Distributions (두 가지 배광을 갖는 LED 횡단보도 조명장치에 관한 연구)

  • Kim, Hyeong Jin;Lee, Dong Kyu;Kwak, Joon Seop
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.9
    • /
    • pp.606-611
    • /
    • 2014
  • Recently, LED lighting fixtures for crosswalk become popular in order to recognize the pedestrians at crosswalk, which can enhance the safety of the pedestrian at crosswalk. However, there are several problems related to the LED lighting fixtures for crosswalk, such as a lot of energy consumption due to a constant illumination during night and glaring of pedestrians at the opposite side of crosswalk. In this study, in order to overcome these problems, we have investigated a novel LED lighting fixture for crosswalk, which has two modules with different angles ($60^{\circ}$, $120^{\circ}$). Illuminance of min and max at four-line city street crosswalk shown 50 Lux, 125 Lux, respectively. Illuminance of min and max at eight-line city street crosswalk shown 150 Lux, 200 Lux, respectively. Simulation investigation was optimized design using optical program. Prototype was verified measurement by goniometer system.

Examination for Methodology of Design of Emergency Lightings by Using Space Syntax Theory (공간구문론을 이용한 지하공간 비상유도등의 효율적인 위치선정 방법론 검토)

  • Won, Seul-Ki;Kim, Young-Uk;Choi, An-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.10
    • /
    • pp.1-9
    • /
    • 2006
  • The emergency lighting plan for underground space should be done with consideration of characteristics of the space. In terms of utilizing the Depthmap program from the Space Syntax theory, it is possible to analyze space quantitatively. Integration and intelligibility are major induces of this theory and we can use them as emergency lighting design parameters. For this study, human behaviors and survivor's evacuation routes in fire emergencies are analyzed through literature review. Based on those results, this study suggests the methodology of emergency lighting plan in underground space.

A Study of a Sunlight Collector System and Its Application (태양광 채광시스템의 조명 적용에 관한 연구)

  • 박준석;어익수;여인선
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.4
    • /
    • pp.1-6
    • /
    • 2001
  • In this paper, it is analysed the spectrum of optical fiber output through the sunlight collector system. As the result of the analysis, the sunlight collector system's UV distribution is lower then the sunlight'UV distribution. Also, the lighting environments under the optical fiber bundles are predicted when applied to the minimum workroom's(6${\times}$6${\times}$2.3[m]) interior lighting by using a lighting design program. In case of optical filer output\`s hight of 1.3[m], the illuminance value over 500[lx] in the area 50${\times}$50[cm] was achieved. As the result its feasibility as an interior lighting source shows no serious problem except the system cost.

  • PDF

An Analysis of Classroom Illuminance with Simulation Program end Improvement of Classroom Illumination (시뮬레이션 프로그램을 활용한 교실조도 분식 및 개선안)

  • Shin, Hyun-Man;Jang, Woo-Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.6
    • /
    • pp.14-23
    • /
    • 2009
  • The actual conditions of school illumination was investigated. The illumination state was classified by the number of installed luminaires per 1 classroom. The illuminance was measured and analyzed. The work surface illuminance was up to the standard, but the illuminance on blackboard was below standard when there was no local lighting. As a result of conducting a simulation based on the measurement of the reflection factors of the classroom finishing materials and lamp replacement and lamp cleaning, nine luminaires for general lighting and local lighting for the blackboard were required, and a design considering illumination maintenance was called for.

Visual Performance Evaluation Study of a Scaled Light-Shelf Model (축소모형을 이용한 광선반의 시환경 특성 평가 연구)

  • Cho, Yil-Sik;Kim, Byoung-Soo;Lee, Jin-Sook
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.3
    • /
    • pp.63-71
    • /
    • 2003
  • According to the recent report, the lighting energy consumption of commercial buildings reaches to $30%\sim40%$ of the total energy consumption. It is more than that of cooling & heating energy consumption and it is the major target of energy-saving policy. It is obvious that they are interested in natural lighting device such as Light-shelf for the purpose of raising the lighting energy-saving efficiency. In most of highly developed countries, a thorough study on Light-shelf makes it possible to propose a practical plan while at home there leaves much to be desired to study a guiding principle of optimum plan in spite of its efficiency based on experiments using scale4 model and analysis of simulation. Aiming at making an optimum plan of Light-shelf suitable for the domestic situation, this study is worked by experiments using light-shelf and analysis of variables using illumination program. The experiments is to analyse the efficiency of Light-shelf on condition of the sky and the analysis is to make the simulation using illumination program. This study is composed of 1) the analysis of light with some variables such as presence of light-shelf and degree of angle using 1/2 scaled model 2) making the simulation using Lightscape, illumination program, In brief, concerning presence of light-shelf, it causes little difference in its efficiency in the overcast sky, whereas it decreases an illuminance of window side and provides inner side with the light, which decreases the ratio of the maximum to the minimum inner illuminance and makes the inner of illuminance to range evenly in the clear sky. On degree of angle, as the daylight increases in proportion of degree of angle, the ratio of the maximum to the minimum inner illuminance decreases, which makes it possible to increase the proportion of inner daylight.