Browse > Article
http://dx.doi.org/10.5207/JIEIE.2009.23.6.014

An Analysis of Classroom Illuminance with Simulation Program end Improvement of Classroom Illumination  

Shin, Hyun-Man (서울산업대학교 전기공학과, 서울특별시교육청 교육시설관리사업소)
Jang, Woo-Jin (서울산업대학교 전기공학과)
Publication Information
Journal of the Korean Institute of Illuminating and Electrical Installation Engineers / v.23, no.6, 2009 , pp. 14-23 More about this Journal
Abstract
The actual conditions of school illumination was investigated. The illumination state was classified by the number of installed luminaires per 1 classroom. The illuminance was measured and analyzed. The work surface illuminance was up to the standard, but the illuminance on blackboard was below standard when there was no local lighting. As a result of conducting a simulation based on the measurement of the reflection factors of the classroom finishing materials and lamp replacement and lamp cleaning, nine luminaires for general lighting and local lighting for the blackboard were required, and a design considering illumination maintenance was called for.
Keywords
Classroom Illuminance; Illumination Maintenance; Lighting Simulation;
Citations & Related Records
연도 인용수 순위
  • Reference
1 김현지, "실내공간에서의 인공조명 균제도 산출방법에 대한 일고찰", 조명전기설비학회논문지 Vol.13,No.2, pp. 7-11, May 1999
2 LIGHTING HANDBOOK 8th.ed. pp.60-62, IESNA
3 장우진외 5인, 최신조명환경원론, pp.206-207, 문운당, 2008
4 장우진외 5인, 최신조명환경원론, p.338, 문운당, 2008
5 한국조명설비학회, 조명설계 표준화에 관한연구, 통상산업부, 1996
6 한국표준협회, KS 조도기준(KS A 3011- 2008)
7 에너지관리공단, 학교건물의 에너지 관련시설 최적화 방안연구, 산업자원부, 1996
8 김훈, "조명전력허용기준", 월간전기, pp.43-46, 2008년 3월호