• 제목/요약/키워드: Lighting Management System

검색결과 131건 처리시간 0.024초

Visible Light Communication Method for Personalized and Localized Building Energy Management

  • Jeong, Jin-Doo;Lim, Sang-Kyu;Han, Jinsoo;Park, Wan-Ki;Lee, Il-Woo;Chong, Jong-Wha
    • ETRI Journal
    • /
    • 제38권4호
    • /
    • pp.735-745
    • /
    • 2016
  • The Paris agreement at the 21st Conference of the Parties (COP21) emphasizes the reduction of greenhouse gas emissions and increase in energy consumption in all areas. Thus, an important aspect is energy saving in buildings where the lighting is a major component of the electrical energy consumption. This paper proposes a building energy management system employing visible light communication (VLC) based on LED lighting. The proposed management system has key characteristics including personalization and localization by utilizing such VLC advantages as secure communication through light and location-information transmission. Considering the efficient implementation of an energy-consumption adjustment using LED luminaires, this paper adopts variable pulse position modulation (VPPM) as a VLC modulation scheme with simple controllability of the dimming level that is capable of providing a full dimming range. This paper analyzes the VPPM performances according to variable dimming for several schemes, and proposes a VPPM demodulation architecture based on dimming-factor acquisition, which can obtain an improved performance compared to a 2PPM-based scheme. In addition, the effect of a dimming-factor acquisition error is analyzed, and a frame format for minimizing this error effect is proposed.

A Wireless Controllable Group Lighting System for Electrodeless Fluorescent Lamps

  • Ma, Xian-Chao;Xu, Hai;Kim, Hoon;Kim, Hee-Jun;Cho, Kyu-Min
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.166-168
    • /
    • 2007
  • A dimmable ballast system for the electrodeless fluorescent lamp is proposed. The proposed scheme is composed of the electronic ballast and the wireless communication part. They both are realized with one EPLD (Erasable Programmable Logic Device). The dimming levels of each lamps can be controlled by a management system through wireless communication technology. 10 ballasts are used for the group lighting system and the experiment results show the system works well.

  • PDF

빌딩 에너지 관리 최적화 알고리즘 설계 및 구현 (Design and Implementation of Optimal Control Algorithms for Building Energy Management)

  • 진중화;정선태
    • 설비공학논문집
    • /
    • 제16권10호
    • /
    • pp.969-976
    • /
    • 2004
  • Building energy saving is one of the most important issues in these days. Energy saving control strategies should be developed properly to achieve the saving. One of such area we could apply is the HVAC (Heating, Ventilation and Air-Conditioning) system. Through the optimal control algorithm for building energy management system (EMS), you can not only save the cost of building energy, but also protect HVAC system components against the unexpected condition. In order to verify the effectiveness of building energy saving, field test was accomplished for several months at 'A' building. And to get the measured data, remote control was used. If the remote control is used in BAS (Building Automation System), control and monitoring can be done for all of the building systems, such as HVAC, power, lighting, security and fire-alarm etc. anywhere any time. Using the remote control, Control and monitoring is possible for the testing system without going there. As the results of field test, we could reduce $5{\sim}10\%$ of the building energy cost.

BEMS 데이터를 활용한 도서관 건물의 운전현황 분석 -준공 초기단계의 건물 에너지 성능 평가 (An Operation Status Analysis of Library Building using BEMS Data; Energy Performance Evaluation on Initial Stage of Completion)

  • 박성철;하주완;김환용;송영학
    • 한국건축친환경설비학회 논문집
    • /
    • 제12권6호
    • /
    • pp.669-679
    • /
    • 2018
  • Energy consumption savings in buildings should be reviewed in diverse areas such as air conditioning system and lighting responsible for cooling and heating, and energy management systems such as BAS (Building Automation System) and BEMS (Building Energy Management System) are introduced to improve energy consumption efficiency and to promote economic control of related facilities by integrated management of energy generated and consumption in buildings. The measured building of this study uses regenerative geothermal system. Measured values of heat pump and system COP were 4.7 and 4.2 respectively, and they were found to be higher 11.9% and 23.5% than rated values. As a result of analyzing the air conditioning and lighting energy from the first floor to the fourth floor performing the air conditioning, the second and third floors, which have a high frequency of use, are compared with the first and fourth floors 50% higher energy consumption ratio. On the other hand, the general heat storage system uses the nighttime power of the previous day to store heat and use it the next day. The total number of days of abnormal operation during the summer season is 61 days. The electricity cost corresponding to the abnormal operation is 1,840,641 KRW, and the normal operation using the nighttime power is 1,363,561 KRW, which is difference of 477,080 KRW, 35% increase in cost. We will utilize it as the main data of BEMS through analysis of winter operation characteristics as well as summer operation characteristics.

Design and Implementation of Road Construction Risk Management System based on LPWA and Bluetooth Beacon

  • Lee, Seung-Soo;Kim, Yun-cheol;Jee, Sung-Hyun
    • 한국컴퓨터정보학회논문지
    • /
    • 제23권12호
    • /
    • pp.145-151
    • /
    • 2018
  • While commercialization of IoT technologies in the safety management sector is being promoted in terms of industrial safety of large indoor businesses, implementing a system for risk management of small outdoor work sites with frequent site movements is not actively implemented. In this paper, we propose an efficient dynamic workload balancing strategy which combined low-power, wide-bandwidth (LPWA) communication and low-power Bluetooth (BLE) communication technologies to support customized risk management alarm systems for each individual (driver/operator/manager). This study was designed to enable long-term low-power collection and transmission of traffic information in outdoor environment, as well as to implement an integrated real-time safety management system that notifies a whole field worker who does not carry a separate smart device in advance. Performance assessments of the system, including risk alerts to drivers and workers via Bluetooth communication, the speed at which critical text messages are received, and the operation of warning/lighting lamps are all well suited to field application.

IoT를 기반한 조명설비 누전사고 감지시스템에 관한 연구 (A Study on the Leakage Current Detection System of Lighting Installation Using IoT Technology)

  • 박근영;곽동걸;이봉섭;김춘삼;전호진
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 추계학술대회
    • /
    • pp.7-8
    • /
    • 2018
  • In this study, we develop a leakage current detection device of lighting installation. The reed switch using in proposed device is activated when the leakage current is generated. We also design a GUI system of a management computer using LabVIEW and administrator's mobile phone app based on IoT. As results, this study is to build an IoT convergence system and it aims to protect people and property by coping with leakage current fault in real time.

  • PDF

DSM Monitoring을 위한 확산 모델의 계수 추정 (Parameter estimation of the Diffusion Model for Demand Side Management Monitoring System)

  • 최청훈;정현수;김진오
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.1073-1075
    • /
    • 1998
  • This paper presents the method of parameter estimation of diffusion model for monitoring Demand-Side Management Program. Bass diffusion model was applied in this paper, which has different values according to parameters ; coefficients of innovation, imitation and potential adopters. Though it is very important to estimate three parameter, there are no empirical results in practice. Thus, this paper presents the method of parameter estimation in case of few data with constraints to reduce the possibility of bad estimation. The constraints are empirical results or expert's decision. Case studies show the diffusion curves of high-efficient lighting and also forecasting of the peak value for power demand considering diffusion of high-efficient lighting, the feedback and least-square parameter estimation method used in this paper enable us to evaluate the status and forecasting of the effect of DSM program.

  • PDF

백열 전구의 LED 조명 교체에 대한 타당성 분석 - 공공기관을 중심으로 - (Feasibility Analysis on Replacing LED Lighting with Incandescent Bulbs in Public Institution)

  • 박윤미;이명균
    • 한국기후변화학회지
    • /
    • 제1권3호
    • /
    • pp.205-210
    • /
    • 2010
  • LED 조명이 기존 조명 대비 80% 이상의 에너지 절감 효과 및 환경 친화적 특성 등 다양한 장점을 가지고 있으면서도, 높은 가격으로 인해 시장이 제대로 형성되지 못하고 있다. 이에 본 논문은 공공부문의 기존 백열 전구를 LED 조명으로의 교체로 인한 에너지 절감 및 유지 보수 측면에서의 효율성을 분석하기 위해 LED 조명에 대한 경제성 평가를 통해 보급 확대에 대한 타당성을 논하였다. 분석대상은 에너지관리공단에서 시행한 "퇴출관리시스템"을 바탕으로 지식경제부에서 발표한 '백열 전구 현황 및 퇴출실적'을 이용하였다. 공공기관의 백열 전구의 LED 조명 교체에 대한 타당성 분석을 위해서 교체 비용, 연간 절전량 및 전기요금 절감액, 유지보수 비용, $CO_2$ 저감량, 탄소배출권 판매수익을 고려하였다. 경제성 분석 결과, 기존의 백열 전구를 LED 조명으로 교체 시 할인율이 3.26%일 때, 8,648.4백만원으로 NPV가 '양(+)'의 값을 가지는 것으로 분석되어 수익성이 있는 것으로 나타났다.

물류센터의 에너지 효율 개선 방안에 관한 연구 (A Study on the Improvement of Energy Efficiency in Warehouses)

  • 선종근;류호상
    • 조명전기설비학회논문지
    • /
    • 제26권6호
    • /
    • pp.66-72
    • /
    • 2012
  • The main sources of energy consumption in warehouses are MHE(Material Handling Equipment), HVAC(Heating, Ventilating and Air Conditioning) and Lighting. Warehouses in advanced countries raise energy efficiencies with energy consumption diagnosis, technology development and systematic management and improvements for MHE, HVAC and Illuminating, etc. They have managed illuminating system, air conditioning, motor driven system, air circulation method, dock facility, layout, AS/RS, conveyor system and battery management, etc. Ansong Pyeongtaek area investigation resulted that 43.9[%] of enterprises are managing partly energy consumption source. But the data resulted with not substantial management of energy consumption but passive management for only electric bill curtailment. Therefore through survey research & visiting interviews of some companies in Ansong Pyeongtaek area, we understood the status of energy consumption source management and proposed energy efficiency methods on the basis of that results.

조명 제어용 170W급 LLC 공진형 하프브리지 컨버터의 효율 특성 (The efficiency Characteristics of LLC Half-Bridge Resonant Converter for Universal Lighting control system)

  • 임성진;김성완;김창선;유진호;천승환
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 전력전자학술대회
    • /
    • pp.23-24
    • /
    • 2011
  • In this paper, the 170W LLC half bridge DC-DC converter is designed for the lighting management system. The power conversion circuit consists of PFC and isolated LLC resonant converter. The topology of LLC half bridge resonant converter provides ZVS characteristic. And the stresses of voltage and current is smaller than that of the general resonant converters. So we can expect the higher efficiency. The optimal conditions for high efficiency were investigated through by experiment.

  • PDF