• Title/Summary/Keyword: Lighting Energy Saving

Search Result 219, Processing Time 0.024 seconds

A Study on Economic Evaluation of FPL 45[W] Lamp and Ballast to Demand Side Management (FPL45[W]램프, 안정키의 전력수요관리를 위한 경제성 평가 연구)

  • Im, Song-Kug;Cho, Hyun-Kyung;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.4
    • /
    • pp.101-107
    • /
    • 2009
  • The energy efficiency of existing lighting appliances has continuously been improving due to the government aid such as rebate programs and information of energy saving, etc. However, the usage pattern of lighting appliance at this moment has more been increasing higher illumination and indirect lighting method according that the taste of customers has changed variously. This paper estimates the economic evaluation and simulation for FPL45[W] lamp & ballast instead of FPL55 lamp & ballast in order to study the governmental support to demand side management.

Intelligent LED Lighting System Implementation Applied Environmental Reservation Setting (환경예약 설정을 적용한 지능형 LED조명시스템 구현)

  • Choi, Sang Young;Kim, Young Bin;Ryu, Conan K.R.
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.10a
    • /
    • pp.324-327
    • /
    • 2014
  • This paper describes a study on the intelligent LED lighting system implementation applicated environmental reservation setting. The environment variables are preset by ON and OFF time of illuminator and brightness data. The setting data enables to be changed by personal preferences on the selecting menu. It is possible to reduce unnecessary consumption and operation for the lighting system. The system customized by user's environment is convenient for disability by using bluetooth. Thus the system results in cost effective and energy savings. The system performances are examined for convenient operation and energy saving for practicality in implemented system.

  • PDF

Analysis of Energy Performance & Energy Saving with Geothermal Heat Pump System Using TRNSYS Program in a Large Scale Shopping Store (TRNSYS 프로그램을 이용한 대형쇼핑매장 에너지성능해석 및 지열시스템을 도입하는 경우 에너지절약 특성분석)

  • Hong, Won-Pyo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.1
    • /
    • pp.47-56
    • /
    • 2015
  • Energy consumption in buildings is currently a real problem. That is why both assessment of energy performance and effective energy management including renewable energy system are essential. Thus, this paper focuses on a case study to analyze the energy performance and cooling & heating energy saving of a large scale shopping store in Daejeon city. The reference building is simulated by using TRNSYS dynamic simulation tool to examine its annual energy consumption. For annual energy analysis of building, one year energy consumption is surveyed in the field. The related study is carried out in large scale shopping store to investigate the energy consumption and energy use trend of heating, cooling, hot water, lighting, ventilation, equipments and other. The evaluation of energy performance of the geothermal heat pump system installed in a large scale shopping store is also analyzed by TRNSYS tool. From simulation results, it evaluated that the geothermal heat pump system is effective energy savings method in large scale shopping store.

Energy Performance Evaluation of A Primary School Building for Zero Energy School (제로에너지 스쿨을 위한 초등 교육시설의 에너지 성능평가)

  • Yoon, Jong-Ho;Shin, U-Cheul;Cho, Jin-Il;Park, Jae-Wan;Kim, Hyo-Jung;Lee, Chul-Sung
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.121-126
    • /
    • 2009
  • This study analyzed the standard school's energy usage and patterns as the zero-energy goal of primary school building, and proposed the energy reduction process of school building using energy analysis computing simulation tool. As a analysis simulation tool, Visual DOE 4.0 is used. For analysis of actual energy usage, selected primary school that is standard in the nation's energy consumption. Standard of the school's energy consumption analysis were devided into electric and gas energy. Input parameters of the simulation program based on the literature material and field survey material. after, but it was calibrated to comparison with the standard school's energy consumption. Finally, its energy usage analyzed by component and made the priority order of energy saving. Applied energy saving technologies are envelopment insulation, high efficiency lighting, high performance HAVC system and used active equipment system of solar collector and photovoltaic generation for additional savings.

  • PDF

OF-LED illuminated Display Board System for Energy Saying (OF-LED를 이용한 에너지 절약형 광고 조명 시스템)

  • Lee S. R.;Jeon C. H.;Lee S. W.;Lee E. C.
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.851-854
    • /
    • 2004
  • This paper studies Optical Fiber(OF) - LED illuminated display board system for energy saving. The OF-LED illuminated display board system has PV modules, batteries, and charge & discharge system, and dynamic full color display controller. Both maximum power point tracker (MPPT) and constant current & constant current controls (CCVC) are used In govern the charging system. It can be improve the charging efficiency of battery. The objective of this thesis paper is to build advertisement lighting system with OF-LED in to charge a 12-volts lead acid battery by using a field wired PV array. We saved the maintenance cost and developed of advertisement effectiveness. To verify the proposed OF-LED illuminated display board system for energy saving, the detail simulation and experiment results indicate that operating characteristics are verified by experiment with a laboratory prototype in this paper.

  • PDF

Interior Partitioned Layout and Daylighting Energy Performance in Office Buildings

  • Kim, Gon
    • Architectural research
    • /
    • v.1 no.1
    • /
    • pp.31-40
    • /
    • 1999
  • In this age of "Information", many people consider it a deterrent to information flow to provide a hierarchy with private rooms in a modern office layout. There are others, however, who insist that visual and acoustical privacy are more important than any other design factor in achieving higher productivity. The debate may never end, but the partitioned open plan, which is a new form of the vast open plan, has merits of each concept - open and closed layout. Consequently, office design has dramatically shifted to partitioned open planning, with shorter, temporary walls or partitions, originally intended for increasing privacy and diminishing hierarchy, yet still keeping flexibility in spatial organization. The introduction of low-level partitioned spaces in an office layout, however, produces a complicated lighting design problem. Obviously, accurately predicted daylighting performance data are needed not only for daylighting design but for artificial lighting system design. Scale models of 12 sets of unit partitioned spaces are constructed and extensive scale model measurements of both daylight and reflected sunlight have been performed within an artificial sky simulator. The prototype-building interior is modeled with different partition configurations, each of which is modeled using the different envelope geometry and exterior configurations, and then the variations in interior light levels are estimated. The result indicates that partitioned spaces employed in an open plan of modern offices still offer a large potential for daylighting and energy saving as well. Much of the savings may derive from the cumulative effect of reflected sunlight. Optimal design for building envelope geometry and exterior configuration promises additional savings.

  • PDF

An Analysis of Important Factors for Energy Efficient Healthcare Facilities on Experts' Survey (전문가 설문조사를 통한 에너지 효율적인 병원시설을 위한 중요한 영향요소의 분석)

  • Choi, Yeo-Jin;Choi, Yool
    • KIEAE Journal
    • /
    • v.17 no.3
    • /
    • pp.45-50
    • /
    • 2017
  • Purpose: There have been more researches focused on eco-friendly construction practices in order to save energy consumed and these practices have been extensively applied for constructing buildings. However, researches on energy consumption saving and efficiency for hospital facilities have been still insufficient. This research aims to draw factors that affect energy efficiency of hospital buildings through literature reviews and perform an expert-survey using AHP(Analytical Hierarchy Process) method in order to analyze the importances and priorities of these energy efficient factors. Method: Using the AHP method, this paper suggests the importances and priorities of factors to affect energy efficiency in hospital buildings. The survey of experts at a architectural design and a construction management companies was conducted via e-mail and mail. Result: As a result, factors of window and door, insulation, ventilation, and natural lighting turned out relatively important as respectively 0.104, 0.102, 0.101, and 0.095 n the energy efficiency in hospital buildings, while factors of artificial lighting, geothermal, solar heat, and control did unimportant as 0.027, 0.033, 0.043, and 0.053.

Study on Effective EERS Savings Calculating Method through Analysis of Energy Consumption of Electric Motor & Lighting Devices (전동기와 조명기기의 에너지사용 분석을 통해 효과적인 EERS 절감량 산정을 위한 주요인자 도출 연구)

  • Yeom, Jeehoon;Choi, Hanho;Lee, Hyunwoong;Park, Sungwoo;Kim, Changsik;Hahn, Seunghee
    • Journal of Energy Engineering
    • /
    • v.28 no.3
    • /
    • pp.34-41
    • /
    • 2019
  • It is essential to introduce EERS (Energy Efficiency Resource Standards) according to the trend of the era in which energy saving is emphasized, and it is time to settle down in a stable manner. Electric motors and lighting devices, which account for more than 60% of the nation's electricity use, are the most effective items of the EERS. And accurate methods of calculating savings must be preceded. In this study, the operation rate and load rate are measured through the demonstration of energy use at 400 businesses and the measured rates are used for EERS savings calculation. The results imply that the proposed method can be successfully applied to calculate cost-effective and reliable energy savings.

A Experimental Study on Artificial Illumination Control System Illuminated by Daylighting (자연채광을 이용한 인공조명의 제어방법에 관한 실험적 연구)

  • 차광석;김회서
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.8 no.1
    • /
    • pp.21-28
    • /
    • 1994
  • It is very important and necessary to predict luminous enviroment in an interior space. This paper has described about energy saving and evaluated interior visual environment in a office building having on/off turning control lighting system utilizing daylight. In order to predict the interior varior illumination distribution, the scale model was made and examined under various conditions, such ad difference of window glass, and color pattern of wall, floor, and also ceiling lighting system type. This paper suggests that basic fundamental data of lighting design performance in the concept and schematic stages of design.

  • PDF

Improvement of Lighting Control System for Tunnel (터널 조명 제어장치의 성능개선)

  • Eo, Ik-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1964-1966
    • /
    • 2003
  • Lighting in the tunnel makes for safe driving of cars taking into account of change in perception arisen in the sight of drivers of cars entering into and passing tunnel, drivers' mental reaction and unique circumstances of a tunnel. There are many variables to satisfy safe driving in the tunnel. Since tunnels are mostly located in the mountainous area and illumination at the approach part differs largely depending on the surrounding circumstances, a standard different from that of common lighting is applied. An accidentin the tunnel, which involves same danger as in underground, may lead to a large mishap. Therefore, control by sensors inside and outside of tunnel ensures prevention of an accident through control of illumination at the approach part and inside of tunnel. It is very important in the aspect of saving energy since such control is available to reduce depreciation factor resulted from early excessive intensity of illumination.

  • PDF