• 제목/요약/키워드: LightSpeed

검색결과 1,387건 처리시간 0.029초

섬유강화 포스트와 금속주조 포스트의 파절강도 밋 파절양상의 비교 (COMPARISON OF FRACTURE STRENGTH AND PATTERN OF ENDODONTICALLY TREATED TEETH RESTORED WITH FIBER POSTS AND METAL CAST POST)

  • 김미경;김석규
    • 대한치과보철학회지
    • /
    • 제42권5호
    • /
    • pp.535-543
    • /
    • 2004
  • Purpose: The purpose of this study is to compare the effect of two fiber post systems and one metal cast post system on the fracture strength and fracture pattern of crowned, endodontically treated teeth with 2 mm-height of the reamining tooth structure. Materials and methods: A total of 36 recently extracted sound human mandibular premolars were selected Each tooth structure of the crown portion except 2mm-height of the one above the cementoenamel junction was removed. After being endodontically treated, they were randomly distributed into 3 groups: group 1, restored with quarts fiber post(D.T. Light-Post), group 2, with glass fiber post(FRC Postec), and group 3, metal cast post and core. All teeth were fully covered with nonprecious metal crowns. Each specimen was embedded in an acrylic resin block and then secured in a universal load-testing machine. A compressive load was applied at a 130 degree angle to the long axis of the tooth until fractured, at a crosshead speed 20mm/min. The highest fracture loads were measured and recorded as the fracture strength of each specimen. Fracture areas were measured on the mid-buccal and mid-lingual point from the crown margins. One-way analysis of variance and Turkey test were used to determine the statistic significance of the different fracture loads and areas among the groups (p<0.05). Results: The mean fracture loads were $1391{\pm}$425N(group 1), $1458{\pm}476N$(group 2) and $1301{\pm}319N$(group 3). The fracture loads among the three groups had no statistically signifiant difference (p>.05). The mean fracture area of the fiber post was closer to the crown margin than that of the metal cast post and core(p<.05). The metal cast post showed unrestorable and catastrophic fracture patterns. Conclusion: Within the limitations of this study, fracture loads with any statistically significant difference were not recorded for endodontically treated teeth restored with two fiber posts and the metal cast post. But teeth restored with the fiber posts typically showed the fracture pattern close to the crown margin, which was almost restorable.

봄 출현 나방의 지역별 종 다양성 양상과 출현에 미치는 기후영향 연구 (Regional Diversity Pattern of Spring Moths and Climatic Effects on Moth Catches)

  • 노동호;김성수;최세웅
    • 환경생물
    • /
    • 제34권1호
    • /
    • pp.30-36
    • /
    • 2016
  • 이 연구는 한국 중부지방 용인과 남부지방 무안에서 봄 출현 나방의 다양성 양상과 나방 종 및 개체수에 영향을 주는 기후 요인을 알아보기 위해서 이루어졌다. 나방은 2013년부터 2015년까지 4월 한 달 동안 일주일 간격으로 자외선등 트랩을 이용하여 채집하였다. 기후요인은 $8^{\circ}C$를 기본으로 한 적산온도 (GDD8), 평균온도, 강우량, 일조시간, 풍속, 신적설 등이다. 나방 종 수 및 개체수에 영향을 주는 기후요인은 단기 (채집주부터 3주전까지)와 장기 (채집 4~12주전)로 나누어 분석하였다. 봄 출현 나방은 과 구성에서 유사한 양상을 띠었지만 지역별로 우점한 과는 차이를 나타내었다. 자나방과는 중부지방에서 우점한 반면 밤나방과는 남부지방에서 우점하였다. 밤나방과의 우점종은 4월 초에 나타난 반면 자나방과의 우점종은 4월 말에 나타나 시간적인 차이도 나타내었다. GDD8, 일조시간, 채집 일주일 전 강우량 등 3개의 단기 기후요인은 나방 종 수 및 개체수에 영향을 준 요인으로 나타난 반면 채집 4주전 평균기온만 장기 기후요인으로 나방 종 수에 영향을 준 것으로 나타났다. 이 연구에서는 한국에서 봄 출현 나방으로 자나방과와 밤나방과 종이 우점하며 이들은 4월 중 우점도와 비행시기에 차이가 있는 것도 알 수 있었다. 봄 출현 나방은 따뜻함과 강우량에 영향을 받는 것으로 나타났다. 최근 기후변화는 봄 출현 나방에도 영향을 줄 수 있어 이에 대한 지속적인 감시가 필요할 것으로 생각한다.

PCTC 박판 블록 용접 변형에 관한 연구 (A Study on Welding Deformation of thin plate block in PCTC)

  • 강성구;양종수;김호경
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2009년 추계학술발표대회
    • /
    • pp.97-97
    • /
    • 2009
  • The use of thin plate increases due to the need for light weight in large ship. Thin plate is easily distorted and has residual stress by welding heat. Therefore, the thin plate should be carefully joined to minimize the welding deformation which costs time and money for repair. For one effort to reduce welding deformation, it is very useful to predict welding deformation before welding execution. There are two methods to analyze welding deformation. One is simple linear analysis. The other is nonlinear analysis. The simple linear analysis is elastic analysis using the equivalent load method or inherent strain method from welding experiments. The nonlinear analysis is thermo-elastic analysis which gives consideration to the nonlinearity of material dependent on temperature and time, welding current, voltage, speed, sequence and constraint. In this study, the welding deformation is analyzed by using thermo-elastic method for PCTC(Pure Car and Truck Carrier) which carries cars and trucks. PCTC uses thin plates of 6mm thickness which is susceptible to welding heat. The analysis dimension is 19,200mm(length) * 13,825mm(width) * 376mm(height). MARC and MENTAT are used as pre and post processor and solver. The boundary conditions are based on the real situation in shipyard. The simulations contain convection and gravity. The material of the thin block is mild steel with $235N/mm^2$ yield strength. Its nonlinearity of conductivity, specific heat, Young's modulus and yield strength is applied in simulations. Welding is done in two pass. First pass lasts 2,100 second, then it rests for 900 second, then second pass lasts 2,100 second and then it rests for 20,000 second. The displacement at 0 sec is caused by its own weight. It is maximum 19mm at the free side. The welding line expands, shrinks during welding and finally experiences shrinkage. It results in angular distortion of thin block. Final maximum displacement, 17mm occurs around welding line. The maximum residual stress happens at the welding line, where the stress is above the yield strength. Also, the maximum equivalent plastic strain occurs at the welding line. The plastic strain of first pass is more than that of second pass. The flatness of plate in longitudinal direction is calculated in parallel with the direction of girder and compared with deformation standard of ${\pm}15mm$. Calculated value is within the standard range. The flatness of plate in transverse direction is calculated in perpendicular to the direction of girder and compared with deformation standard of ${\pm}6mm$. It satisfies the standard. Buckle of plate is calculated between each longitudinal and compared with the deformation standard. All buckle value is within the standard range of ${\pm}6mm$.

  • PDF

기선권현망어업의 어구개량과 자동화조업시스템 개발- II 수중광 및 예망유속과 멸치의 도피반응 행동 분석 (Improving of the Fishing Gear and Development of the Automatic Operation System in the Anchovy Boat Seine- II Analysis of escaping behaviour of anchovy in relation to underwater light and towing flow velocity)

  • 김용해;장충식;안영수;김형석
    • 수산해양기술연구
    • /
    • 제37권2호
    • /
    • pp.78-84
    • /
    • 2001
  • 1999년 5월 29일부터 6월 30일까지의 남해안에서의 수심에 따른 수중광의 변화와 조업시간의 경과에 따른 예망 상대유속을 측정하고, 권현망어구에 대한 체장 4~7cm정도 되는 멸치들의 도피 반응행동을 관찰하고 분석한 결과는 다음과 같다. 1) 남해안 통영, 거제 부근 멸치어장에서 수심에 대한 수중광의 변화를 자연대수 곡선식으로 나타내면 광흡수 계수 c는 대표적인 관측점에서 주로 0.24~1.03 범위로 나타나서, 멸치의 어구에 대한 시인도가 어장에 따라 클 것으로 보인다. 2) 권현망어구의 원형그물과 1/2축소그물의 자루그물 입구부분의 상대유속을 기준으로 할때, 수비와 자루의 연결부분의 유속비는 평균 1.46, 자루부분의 유속비는 평균 0.67로 나타나서, 어구의 부위에 따른 상대유속변화가 멸치의 유영운동과 도피운동에 영향을 줄 것으로 보인다. 축소된 권형망어구에 있어서의 멸치의 대망행동을 관찰한 결과 수비와 자루연결부분에서 빠져나가는 1분당 멸치도피수는 평균 455미 정도였으며, 자루의 앞에서 예인방향으로 유영하는 깔대기를 빠져나가는 1분당 멸치도피 수는 평균 308미 정도로 나타나서, 어구 전체적으로는 상당수의 멸치들이 능동적인 도피행동을 나타내는 것으로 추측된다.

  • PDF

실내·외 조도에 따른 스테레오 CCTV 영상 정합점 수 변화 (Changes in the Number of Matching Points in CCTV's Stereo Images by Indoor/Outdoor Illuminance)

  • 문광일;편무욱;김종화;김강산
    • 대한공간정보학회지
    • /
    • 제23권1호
    • /
    • pp.129-135
    • /
    • 2015
  • 도시기반시설에 첨단 정보통신기술을 융합하여 언제 어디서나 자유롭게 서비스를 제공하고자 하는 U-City(Ubiquitous City)의 공간정보기술은 다양한 형태로 서비스 되고 있다. 그 중에서도 U-City에서 가장 많이 설치되어 있는 CCTV(Closed Circuit TV)의 스테레오 영상을 가지고 특징점(Key Point)을 선정하여 정합(Matching)하고 3차원 공간정보를 구축하는 연구가 진행되고 있다. 하지만 대부분 정합점을 추출하는데 사용된 데이터는 조도와 같은 외부 환경영향을 고려하지 않고 있다. 본 논문은 동일한 하드웨어에서 조도의 변화에 의해 영상의 질이 좌우되는 CCTV를 가지고 3차원 공간정보를 구축하는데 필요한 정합점이 조도에 따라 얼마나 변화 하는지 실험을 하였다. 조도에 따른 정합점 수의 분석 결과, 카메라의 조리개, 셔터속도, 감도를 고정하였을 때 3,000Lux까지 정합점 수가 조도에 비례하여 높아 졌으며, 물체와 배경의 경계가 뚜렷해졌다. 반대로 빛이 과도하게 들어 왔을 경우 화면이 밝이지며, 노이즈가 발생하고 사물과 사물의 경계가 없어져 특징점을 선정하기가 힘들었다. 본 논문에서 얻어진 결과를 이용하여 촬영할 경우 향상된 정합점을 가질 수 있을 것으로 기대된다.

이원중합형 코어 축조용 복합레진의 결합강도에 대한 NaOCI의 영향에 대한 연구 (Influence of Sodium Hypochlorite on Bond Strength of Dual-cured Core Build-up Resin Composite)

  • 이준봉;박종덕;권수미;유미경;이광원
    • 구강회복응용과학지
    • /
    • 제23권4호
    • /
    • pp.283-292
    • /
    • 2007
  • Two-step or one-step bonding systems generally inhibit curing process of dual-cured core build-up resin composite for their adhesive acidity. In addition this dual-cured core build-up resin composite can be applied to dentin of pulp chamber and root at the time that complete the endodontic treatment. The purpose of this investigation was to determine the influence of sodium hypochlorite on rnicrotensile bond strength of dual-cured core build-up resin composite. Extracted human molars were horizontally sectioned with 1mm thickness using low speed diamond saw. After the sectioned specimens were divided into 8 groups, adhesive systems (Clearfil SE-Bond, Prime&Bond NT[2-step, 1-step], Adper Prompt L-Pop) were then applied with or without sodium hypochlorite pretreatment. The treated specimen was filled with dual-cured core build-up resin composite (Luxacore, DMG corp., German). Then light cured for 40 seconds and soaked in $37^{\circ}C$ water bath for 24 hours. After the treated specimen was grinded with 1mm width and measured rnicrotensile bond strength by testing machine. Additionally 8 teeth were prepared for SEM evaluation. The results were as follows. : NaOCl treated groups generally had lower rnicrotensile bond strength but did not show any difference statistically except Adper Prompt L-Pop. When the teeth were treated by NaOCl, though the difference of applied adhesive system, it had no statistically significant difference within the NaOCl treated groups except the relation of between ClearFil SE-Bond adhesive system and Adper Prompt L-Pop adhesive system. In the SEM evaluation, NaOCl treated groups presented relatively long resin tags and incomplete hybrid layer formation generally.

주파수 전압 변환을 이용한 듀얼 모드 벅 변환기 모드 제어 설계 (Mode Control Design of Dual Buck Converter Using Variable Frequency to Voltage Converter)

  • 이태헌;김종구;소진우;윤광섭
    • 한국통신학회논문지
    • /
    • 제42권4호
    • /
    • pp.864-870
    • /
    • 2017
  • 본 논문은 넓은 부하 전류를 요구하는 휴대 기기에서 사용될 목적으로 주파수 전압 변환을 이용하여 모드 제어 가능한 듀얼 모드 벅 변환기를 설명한다. 기존의 히스테스테릭 벅 변환기의 문제인 저 부하에서의 PLL 보상 및 효율 저하를 제안하는 듀얼 벅 변환기의 개선된 PFM 모드를 통해 해결한다. 또한 기존의 듀얼 모드 벅 변환기의 주요 회로인 모드 제어기에서의 부하 변화 감지의 어려움과 느린 모드 전환 속도를 제안하는 모드 제어기로 개선 시킨다. 제안하는 모드 제어기는 최소 1.5us의 모드 전환 시간을 가진다. 제안하는 DC-DC 벅 변환기는 $0.18{\mu}m$ CMOS 공정에서 설계하였으며 칩 면적은 $1.38mm{\times}1.37mm$이다. 기생 소자를 포함한 인덕터와 커패시터를 고려한 후 모의실험 결과는 1~500mA의 부하 전류 범위에서 입력 전압을 2.7~3.3V를 가지며 PFM 모드는 65mV이내, 히스테리틱 모드에서는 고정된 스위칭 주파수 상태에서 16mV의 출력 리플 전압을 가지는 1.2V의 출력 전압을 생성한다. 제안하는 듀얼 모드 벅 변환기의 최대 효율은 80mA에서 95%를 나타내며 해당 전체 부하 범위에서 85% 이상의 효율을 지닌다.

단동 플라스틱 온실의 천창 환기효과와 설치기준 분석 (Analysis on the installation criteria and ventilation effect for round roof windows in single-span plastic greenhouses)

  • 남상운;김영식;고기혁;성인모
    • 농업과학연구
    • /
    • 제39권2호
    • /
    • pp.271-277
    • /
    • 2012
  • Dimensions, operation conditions and improvement items for round roof windows were investigated in arch shape single-span plastic greenhouse with roof vents, and natural ventilation performance was analyzed based on the ventilation theory. Diameter of round roof windows was mostly 60 cm, and chimney height projected on roof was average 30 cm. Installation space was mostly 5 to 6 m but farmhouse of 10 m and over was 16.7% also. A round roof window which has 60 cm diameter was installed to 6 m space generally and 80 cm diameter was installed to 10 m space, but correct standards did not exist. There were a lot of opinions that ventilation effect of round roof windows is fairly good and user satisfaction is generally excellent. It is problem that there is few effects in summer and that vinyl around each vent tears well and rainwater leaks, and improvement hope item required development of automatic control system. In the wind speed of 0.3 m/s, it was estimated that natural ventilation rates were 0.69, 0.55, 0.50 and 0.48 volumes per minute in case of 2, 4, 6 and 8 m installation space for round roof windows, respectively. It was analyzed that the ratio of ventilation due to buoyancy out of total ventilation were 65.2, 41.9, 29.9 and 22.8% in case of 2, 4, 6 and 8m installation space, respectively. By the round roof windows installed at space of 6 m, ventilation rate was estimated to 0.5 volumes per minute, and we can expect the increase in ventilation rate of 30%. In order to meet the recommended ventilation rate for summer season, we have to install the round roof windows at space of 1 to 2 m. However, it is difficult to apply those installation space because of falling productivity due to lower light transmittance as well as rising costs. It is estimated that the installation space of 6m is appropriate for spring or fall season. Therefore it is necessary to encourage installing the roof windows in single-span plastic greenhouses.

레진강화형 글라스아이오노머의 2 축 굽힘강도 (BI-AXIAL FRACTURE STRENGTH OF RESIN MODIFIED GLASS IONOMERS)

  • 이용근;임미경;구대회;이정식
    • Restorative Dentistry and Endodontics
    • /
    • 제22권2호
    • /
    • pp.751-760
    • /
    • 1997
  • Resin-modified glass ionomers were introduced in 1988 to overcome the problems of moisture sensitivity and low early mechanical strengths of the conventional glass ionomers, and to maintain their dinical advantages. The purpose of this study was to evaluate the bi-axial fracture strength of four resinmodified glass-ionomers(Fuji II LC, Vitremer, Dyract, VariGlass), one resin composite material(Z-100), and one conventional glass-ionomer(Fuji II). Three specimens of each material and shade combination were made according to the manufacturers' instructions. Materials were condensed into metal mold with a diameter of 10mm and a thickness of 2.0mm and pressed between two glass plates. Resin-modified glass ionomers were polymerized using a Visilux II light curing unit by irradiating for 60 seconds from both sides, and conventional glass ionomer was cured chemically. After specimens were removed from the molds, surfaces were polished sequentially on wet sandpapers up to No. 600 silicone carbide paper. The specimens were thermocycled for 2,000 cycles between $5^{\circ}C$ and $55^{\circ}C$ distilled water. After thermocycling, bi-axial fracture strengths were measured using a compressive-tensile tester(Zwick 1456 Z020, Germany) with the cross head speed of 0.5mm/minute. The results were as follows: 1. Two factors of the kind and color of materials had a main effect on bi-axial fracture strength (p<0.01), and bi-axial fracture strength was influenced significantly by the kinds of materials (p<0.01). But there was no significant interaction between two variables of the kind and color of materials (p>0.05). 2. Comparing the mechanical properties of the materials, the elastic modulus of Z100 was higher than any other material, and there was no difference in the displacement at fracture among materials. The bi-axial fracture strength of Z100 was significantly higher than any other material, and that of resin-modified glass ionomers was significantly higher than that of conventional glass ionomer (p<0.05). 3. In the same material group, the color of material had little influence on the mechanical properties.

  • PDF

롤러 신발과 조깅 슈즈 신발 착용 후 보행 시 지면반력의 형태 비교 분석 (The Effects of Wearing Roller Shoes on Ground Reaction Force Characteristics During Walking)

  • 채원식
    • 한국운동역학회지
    • /
    • 제16권1호
    • /
    • pp.101-108
    • /
    • 2006
  • The purpose of this study was to compare GRF characteristics during walking wearing jogging and roller shoes. Twelve male middle school students (age: $15.0{\pm}0.0\;yrs$, height: $173.6{\pm}5.0\;cm$, weight: $587.6{\pm}89.3\;N$) who have no known musculoskeletal disorders were recruited as the subjects. Kinematic data from six S-VHS camcorders(Panasonic AG456, 60 fields/s) and GRF data from two force platform; (AMII OR6-5) were collected while subjects walked wearing roller and jogging shoes in random order at a speed of 1.1 m/s. An event sync unit with a bright LED light was used to synchronize the video and GRF recordings. GRF data were filtered using a 20 Hz low pass Butterworth. digital filter and further normalized to the subject's body weight. For each trial being analyzed, five critical instants and four phases were identified from the recording. Temporal parameters, GRFs, displacement of center of pressure (DCP), and loading and decay rates were determined for each trial. For each dependent variable, paired t-test was performed to test if significant difference existed between shoe conditions (p <.05). Vertical GRFs at heel contact increased and braking forces at the end of initial double limb stance reduced significantly when going from jogging shoe to roller shoe condition. Robbins and Waked (1997) reported that balance and vertical GRF are closely related It seems that the ankle and knee joints are locked in an awkward fashion at the heel contact to compensate for the imbalance. The DCP in the antero-posterior direction for the roller shoe condition was significantly less than the corresponding value for the jogging shoe condition. Because the subjects tried to keep their upper body weight in front of the hip to prevent falling backward, the DCP for the roller shoe condition was restricted The results indicate that walking with roller shoes had little effect on temporal parameters, and loading and decay rates. It seems that there are differences in GRF characteristics between roller shoe and jogging shoe conditions. The differences in GRF pattern may be caused primarily by the altered position of ankle, knee, and center of mass throughout the walking cycle. Future studies should examine muscle activation patterns and joint kinematics during walking with roller shoes.