Dimensions, operation conditions and improvement items for round roof windows were investigated in arch shape single-span plastic greenhouse with roof vents, and natural ventilation performance was analyzed based on the ventilation theory. Diameter of round roof windows was mostly 60 cm, and chimney height projected on roof was average 30 cm. Installation space was mostly 5 to 6 m but farmhouse of 10 m and over was 16.7% also. A round roof window which has 60 cm diameter was installed to 6 m space generally and 80 cm diameter was installed to 10 m space, but correct standards did not exist. There were a lot of opinions that ventilation effect of round roof windows is fairly good and user satisfaction is generally excellent. It is problem that there is few effects in summer and that vinyl around each vent tears well and rainwater leaks, and improvement hope item required development of automatic control system. In the wind speed of 0.3 m/s, it was estimated that natural ventilation rates were 0.69, 0.55, 0.50 and 0.48 volumes per minute in case of 2, 4, 6 and 8 m installation space for round roof windows, respectively. It was analyzed that the ratio of ventilation due to buoyancy out of total ventilation were 65.2, 41.9, 29.9 and 22.8% in case of 2, 4, 6 and 8m installation space, respectively. By the round roof windows installed at space of 6 m, ventilation rate was estimated to 0.5 volumes per minute, and we can expect the increase in ventilation rate of 30%. In order to meet the recommended ventilation rate for summer season, we have to install the round roof windows at space of 1 to 2 m. However, it is difficult to apply those installation space because of falling productivity due to lower light transmittance as well as rising costs. It is estimated that the installation space of 6m is appropriate for spring or fall season. Therefore it is necessary to encourage installing the roof windows in single-span plastic greenhouses.
Keywords
Installation space; Natural ventilation; Round roof window; Single-span plastic greenhouse; Temperature difference;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 Albright LD. 1990. Environment control for animals and plants. pp. 200-201. ASAE. St. Joseph, Michigan.
2 American Society of Agricultural Engineers (ASAE). 1997. ASAE Standards : Heating, ventilating and cooling greenhouses. pp. 663-670. ASAE. St. Joseph, Michigan.
3 Blomgren T, Frisch T. 2007. High tunnels using low-cost technology to increase yields, improve quality and extend the season. pp. 1-22. The University of Vermont Center for Sustainable Agriculture.
4 Hanan JJ. 1998. Greenhouses: Advanced technology for protected horticulture. pp. 236-243. CRC Press. Boca Raton, Florida.
5 Hellickson MA, Walker JN. 1983. Ventilation of agricultural structures. pp. 103-124, pp. 297-319. ASAE. St. Joseph, Michigan.
6 Kim MK, Kim KS, Nam SW. 2001. Efficient application of greenhouse cooling system. pp. 194-204. Ministry of Agriculture and Forestry. [in Korean]
7 Lindley JA, Whitaker JH. 1996. Agricultural buildings and structures. Revised edition. pp. 463-484. ASAE. St. Joseph, Michigan.
8 Ministry for Food, Agriculture, Forestry and Fisheries (MIFAFF), Rural Development Administration (RDA). 2010. Designated notice of standards to endure disaster for horticultural and herbal facilities. [in Korean]
9 Nam SW. 2001. Roof ventilation structures and ridge vent effect for single span greenhouses of arch shape. CNU Journal of Agricultural Science 28(2): 99-107. [in Korean]
10 Nam SW, Kim YS. 2009. Actual state of structures and environmental control facilities for tomato greenhouses in Chungnam region. CNU Journal of Agricultural Science 36(1): 73-85. [in Korean]
11 Nam SW, Seo WM, Yoon YC, Lee SK, Lee IB, Lee HW, Cho BK. 2008. Bio-environment control engineering. pp.68-72, pp. 215-218. Cheongsol Pub. Daegu. [in Korean].
12 Nam SW, Kim YS, Both AJ. 2011. Analysis on the ventilation performance of single-span tomato greenhouse with roof windows. Journal of Bio-Environment Control 20(2): 78-82. [in Korean]   과학기술학회마을
13 Son JE, Choi WS. 2000. Analysis of climatic factors during growing period of high-quality oak mushroom. Journal of Bio- Environment Control 9(2): 115-119. [in Korean]   과학기술학회마을
14 Tachibana K, Hanekura K, Takahashi K, Ohtsuka E. 1979. Design and construction of greenhouses for protected horticulture. pp. 91-103. Ohm Pub. Tokyo. [in Japanese].