• 제목/요약/키워드: Light-pipe system

검색결과 86건 처리시간 0.021초

Water Injection/Urea SCR System Experimental Results for NOx Reduction on a Light Duty Diesel Engine

  • Nam, Jeong-Gil
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권3호
    • /
    • pp.394-403
    • /
    • 2008
  • The effects of water injection (WI) and urea injection for NOx on a 4-cylinder Direct Injection (DI) diesel engine were investigated experimentally. For water injection, it was installed at the intake pipe and the water quantity was controlled at the intake manifold and Manifold Air Flow (MAF) temperatures while the urea injection was located at the exhaust pipe and the urea quantity was controlled by NOx quantity and MAF. The effects of WI system, urea-SCR system and the combined system were investigated with and without exhaust gas recirculation (EGR). Several experiments were performed to characterize the urea-SCR system, using engine operating points of varying raw NOx emissions. The results of the Stoichiometric Urea Flow (SUF) and NOx map were obtained. In addition, NOx results were illustrated according to the engine speed and load. It is concluded that the NOx reduction effects of the combined system without the EGR were better than those with the EGR-based engine.

히트파이프를 이용한 온풍난방기 배기열회수 시스템의 열회수 특성 (Heat Recovery Characteristics of the Exhaust Heat Recovery System with Heat Pipe Unit Attached to the Hot Air Heater in the Greenhouse)

  • 강금춘;김영중;유영선;백이;이건중
    • Journal of Biosystems Engineering
    • /
    • 제26권5호
    • /
    • pp.441-448
    • /
    • 2001
  • Hot air heater with light oil combustion is used as the most common heater for greenhouse heating in the winter season. However, exhaust gas heat discharged to atmosphere through chimney reaches up to 10~20% of total heat capacity of the oil burred. In order to recover the heat of this exhaust gas and to use for greenhouse heating, the heat pipe type exhaust heat recovery system was manufactured and tested in this experiment. The system consisted of a heat exchanger made of heat pipes, ø15.88${\times}$600mm located in the rectangular box of 675(L)${\times}$425(W)${\times}$370(H)mm, an air suction fan and air ducts. The number of heat pipe was 60, calculated considering the heat exchange amount between exhaust gas and air and heat transfer capacity of a heat pipe. The working fluid of heat pipe was acetone because acetone is known for its excellent heat transfer capacity. The system was attached to the exhaust gas path. According to the performance test it could recover 53,809 to 74,613kJ/h depending on the inlet air temperature of 12 to -12˚at air flow rate of 1.100㎥/h. The temperature of the exhaust gas left the heat exchanger dropped to 100$^{\circ}C$ from 270$^{\circ}C$ after the heat exchange between the suction air and the exhaust gas.

  • PDF

동도금 EP방열판에 의한 소형LED조명등 방열 (Heat Radiation of LED Light using eu Plating Engineering Plastic Heat Sink)

  • 조영태
    • 한국생산제조학회지
    • /
    • 제20권1호
    • /
    • pp.81-85
    • /
    • 2011
  • Recently, the electronic parts are to be thinner plate, smaller size, light weight material and CPU, HDD and DRAM in all the parts have been produced on the basis of the high speed and greater capacity. Also, conventional goods have replaced a LED (Light-Emitting Diode) in lighting products so; such industry devices need to have cooling. To maximize all the performance on the heat-radiated products, the area of heat-radiated parts is required to be cooled for keeping the life time extension and performance of product up. Existing cooling systems are using radiant heat plate of aluminum, brass by extrusion molding, heat pipe or hydro-cooling system for cooling. There is a limitation for bringing the light weight of product, cost reduction, molding of the cooling system. So it is proposed that an alternative way was made for bringing to the cooling system. EP (Engineering Plastic) of low-cost ABS (Acrylonitrile butadiene styrene Resin) and PC (Polycarbonate) was coated with brass and the coating made the radiated heat go up. The performance of radiant heat plate is the similar to the existing part. We have studied experimentally on the radiated heat plate for the light-weight, molding improvement and low-cost. From now on, we are going to develop the way to replace the exiting plate with exterior surface of product as a cooling system.

새로운 강관말뚝 머리 보강 공법 개발 (A New Way of Connecting Method Between Steel Pipe Pile and Concrete Footing)

  • 박영호;김낙영;박종면;유성근;김영호
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.413-420
    • /
    • 2002
  • Recent experimental research results of connection method between steel pipe pile and concrete footing are provided based on various experimental observations. It gives a shedding light toward developing better and concrete connection method for steel pipe pile at the field application. In this study, the newly developed method is tested for compressive, pull put and combination load including moment with carefully designed monitoring system. The measured data show that new method have at least equivalent or better load resistant capacities compared with those of specified method in Korea Highway Corporation design code. It is also tried to define and investigate the load transfer mechanism for new method.

  • PDF

쾌적 빛 환경을 위한 효율적 조명 시스템 (Efficient Lighting System for Amenity Light Environment)

  • 최종효;오명원;김병선
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.136-141
    • /
    • 2009
  • Considerable part of energy consumption is occurred by through buildings. Especially, Lighting energy consumption is most part of one in building. There is very various ways and systems for saving lighting energy. In method, It can be divided Passive Daylighting System and Active Daylighting System. Louver, Screen and use of window's character is representative ways of passive system. Reflection mirror, optical pipe and optical fiber is representative method of active system. Introducing day light on which place can't be introduced day light by typical method is important advantage of active system. Except introducing day lighting methods, efficient lighting management system can save lighting energy. It called lighting automation system. Representatively, Occupancy-related automation and Brightness-related automation system is that. According to occupancy and introducing daylighting level properly operate lamp's intensity of illumination that can save lots of energy. Though Introducing daylighting method, effective lighting system we can get proper intensity of illuminance level and energy saving.

  • PDF

HEAT PIPE TYPE EXHAUST HEAT RECOVERY SYSTEM FOR HOT AIR HEATER

  • Kang, G.C.;Kim, Y.J.;Ryou, Y.S.;Rhee, K.J.
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 2000년도 THE THIRD INTERNATIONAL CONFERENCE ON AGRICULTURAL MACHINERY ENGINEERING. V.III
    • /
    • pp.654-661
    • /
    • 2000
  • Area of greenhouse increases rapidly up to 45,265ha by the year of 1998 in Korea. Hot air heater with light oil combustion is the most common heater for greenhouse heating in the winter season. However, exhaust gas heat discharged to atmosphere through chimney reaches up to 10~20% of total heat of the oil combusted in the furnace. In order to recapture the heat of this exhaust gas and to recycle for greenhouse heating, the heat pipe type exhaust heat recovery system was manufactured and tested in this experiment. The exhaust heat recovery system was made for space heating in the greenhouse. The system consisted of a heat exchanger made of heat pipes, ${\emptyset}15.88{\times}600mm$ located in the rectangular box of $600{\times}550{\times}330mm$, a blower and air ducts. The rectangular box was divided by two compartments where hot chamber exposed to exhaust gas in which heat pipes could pick up the heat of exhaust gas, and by evaporation of the heat transfer medium in the pipes it carries the heat to the cold compartment, then the blower moves the heat to greenhouse. The number of heat pipe was 60, calculated considering the heat exchange amount between flue gas and heat transfer capacity of heat pipe. The working fluid of heat pipe was acetone because acetone is known for its excellent heat transfer capacity. The system was attached to the exhaust gas path. According to the performance test it could recover 53,809 to 74,613kJ/hr depending on the inlet air temperature of 12 to $-12^{circ}C$ respectively when air flow rate $1,100\textrm{m}^3/hr$. The exhaust gas temperature left the heat exchanger dropped to $100^{circ}C$ from $270^{circ}C$ by the heat exchange between the air and the flue gas, the temperature difference was collected by the air and the warm air temperature was about $60^{circ}C$ at the air flow rate of $1,100\textrm{m}^3/hr$. This heat pipe type exhaust heat recovery system can reduce fuel cost by 10% annually according to the economic analysis.

  • PDF

수계소화설비용 경량벽 스테인리스 강관의 사용가능성 평가에 관한 연구 (A Study on the Possibility of using Light-Wall Stainless Steel Pipe for Water-Based Fire Protection System)

  • 남준석;원성연;김영호;민경탁;박승민
    • 한국화재소방학회논문지
    • /
    • 제24권5호
    • /
    • pp.94-101
    • /
    • 2010
  • 수계소화설비에 사용되고 있는 관으로는 배관용 탄소강관, 압력배관용 탄소강관, 동관 등이 사용되고 있다. 최근 건축물의 고층화, 복합화로 소화설비에는 내식성이 우수하고, 시공성이 간편하며, 가볍고 경제적인 관의 사용이 고려되고 있다. 이러한 특징을 가진 스테인리스 강관과 기존에 사용되고 있는 동관의 물성, 강도, 내식성, 내열성 등의 비교를 통해 스테인리스 강관의 소화설비로의 사용 가능성을 평가하고자 하였다. 그 평가결과로 경량벽 스테인리스 강관인 일반배관용 스테인리스 강관(KS D 3595)은 1.2MPa미만의 압력에서 수계소화설비에 사용될 수 있는 충분한 물성, 강도, 내식성, 내열성 등을 가지고 있음을 확인할 수 있었다.

강관말뚝 머리결합부의 미끄럼 방지턱에 관한 하중전달 메카니즘 연구 (The Experimental Study on Load Transfer Mechanisms in Non-slip Device of Steel Pipe Pile Cap)

  • 김영호
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제8권1호
    • /
    • pp.221-229
    • /
    • 2004
  • 강관말뚝 머리를 확대기초 내에 얕게 근입하는 방법은 작업성과 배근의 용이성 등의 이점 때문에 일본과 우리나라에서 널리 적용되고 있다. 또한 일본은 몇 차례의 시방서 개정으로 말뚝머리 연결방법을 표준화하기에 이르렀고, 다양한 연결방법에 대하여 실험적 연구와 이론적 연구가 축적되었다. 따라서 국내에서도 최근 말뚝머리 보강설계에 대한 연구의 필요성이 대두되어 본 연구에서는 도로교 시방서에서 제시하는 대표적인 강관 말뚝머리 연결부 방법B 속채움방법에 대한 구조적 성능 및 특성을 파악하고자 단순 인발실험 및 단순 압입실험을 실시하여 말뚝머리 연결부의 거동 메카니즘을 규명하고자 한다. 또한 인발 및 압입실험의 결과에서 미끄럼 방지턱을 용접대신 고장력볼트로 접합하여 사용했을 경우 구조적 거동안정성을 파악하고자 한다.

Study on the Systematic Technology of Promoting Purification for the Livestock Wastewater and Reuse

  • Okada, Yoshiichi;Shim, Jae-Do;Mitarai, Masahumi;Kojima, Takayuki;Gejima, Yoshinori
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1996년도 International Conference on Agricultural Machinery Engineering Proceedings
    • /
    • pp.692-700
    • /
    • 1996
  • The objective of this study is to develop a systematic purification plant using the metabolism of aerobic microorganisms. This system is subsequently aerated and continuously removes suspended solids and settling sludges caused by aerating pressure at the bottom of a lower pipe (i.e., Continuous Removal of Suspended solids and Settling sludges, CRSS). The CRSS plants are brought out by introducing fine air bubbles into the liquid phase of a lower pipe in the bio-reactor. These plant uses aeration pipe, with multiple inlets to sweep the floor of bio-reactor tank, instead of the conventional scraper mechanisms. The principal advantage of this system is that it can continuously remove very small or light particles that settles completely within a short time. Once the particles have been floated to the surface, they can be moved into the pipe and collected in the settling tank by sequently aerated pressure. The experimental results shows that about 99.0% of the biochemical oxygen demand(BOD), 99.3% of the suspended solid(SS), 92.3% of the total nitrogen(T-N), 99.0% of the turbidity(TU), 100% of the total coliform(TC)and ammonia was respectively removed during aerobic digestion for 9 days. These result indicates that the CRS S plants are very effective for reduction and deodorization of swine wastewater contaminants, and the efflux from CRS S can either be discharged in the river or used as nutrient solution of formulation for plant growth factories. The developed CRSS plant proved to be flexible and it can simply be adapted to any type of biological waste treatment problem.roblem.

  • PDF

실측을 통한 융착식 플라스틱 입상배관 성능 평가 (An Applicability Estimation of Plastic Vertical Pipes using Electric Fusion Fittings through Measurement)

  • 박률;안영철;김현대;김정수;곽유식;김용경
    • 설비공학논문집
    • /
    • 제25권11호
    • /
    • pp.595-599
    • /
    • 2013
  • The pipes used in buildings are generally categorized into metallic or plastic materials. Metal pipes, such as copper and stainless steel pipes, are mainly used for water and hot water supply, and for the heating system. However, plastic pipes made of polyethylene and cross-linked polyethylene are used for floor heating, water drainage, and air vent systems. Usually, plastic pipes have thermal demerits, such as high linear expansion coefficients and bending phenomenon by hot water, although the pipes have several merits of light weight, low price, low thermal conductivity, and the comparatively high workability of metal pipes. Therefore, if those kind of demerits are overcome, plastic pipes can be easily accepted for hot water systems. This research is aimed to evaluate the applicability for vertical heating pipes of a plastic pipe system consisting of electric fusion fitting of a conductive carbon compound and propylene random glass fiber pipe, through measurement of the expansion rate and leakage in summer and winter seasons, in the apartment construction field.