• 제목/요약/키워드: Light pipe

검색결과 172건 처리시간 0.031초

공기보다 가벼운 가스 사용시설의 폭발위험장소 설정방안에 대한 연구 (A Study on Classification of Explosion Hazardous Area for Facilities using Lighter-than-Air Gases)

  • 임지표;정창복
    • 한국안전학회지
    • /
    • 제29권2호
    • /
    • pp.24-30
    • /
    • 2014
  • There have been controversies over whether explosion hazardous area(EHA) should be classified for facilities which use lighter-than-air gases such as city gas, hydrogen and ammonia. Two view points are confronting each other: an economic piont of view that these gases are lighter than air and disperse rapidly, hence do not form EHA upon release into the atmosphere, and a safety point of view that they are also inflammable gases, hence can form EHA although the extent is limited compared to heavy gases. But various standards such as KS, IEC, API, NFPA do not exclude light gases when classifying EHA and present examples of EHA for light gas facilities. This study calculates EHA using the hypothetical volume in the IEC code where the hole sizes required for the calculation were selected according to various nominal pipe sizes in such a way to conform to the EHA data in the API code and HSL. Then, 25 leakage scenarios were suggested for 5 different pipe sizes and 5 operating pressures that cover typical operating conditions of light gas facilities. The EHA for the minimum leakage scenario(25 mm pipe, 0.01MPa pressure) was found to correspond to a hypothetical volume larger than 0.1 $m^3$(medium-level ventilation). This confirms the validity of classifying EHA for facilities using lighter-than-air gases. Finally, a computer program called HACPL was developed for easy use by light gas facilities that classifies EHA according to operating pressures and pipe sizes.

디젤기관의 성능과 배기관 특성에 의한 필터트랩의 열재생에 관한 실험적 연구 (An Experimental Study on Thermal Regeneration of Filter Trap by Diesel Engine Performance and Characteristics of Exhaust Pipe)

  • 오용석
    • 한국생산제조학회지
    • /
    • 제8권2호
    • /
    • pp.50-55
    • /
    • 1999
  • The exhaust emissions from diesel vehicle are known to be harmful to human health and environment. Recently, one of the most environment problems is particulate matter. In this study, through the actual exper iment and heat transfer of exhaust pipe in light duty diesel engine equipped with the ceramic filter trap of throttling type, following results are obtained. 1. In case of light duty diesel engine equipped with ceramic filter trap of throttling type, Power and torque of engine were decreased about 5%, compared with the case without trap system. It means that was not so much effect on base engine performance.2. If the length of exhaust pipe when equipping with ceramic filter trap is suitably controlled, the range of regeneration will be expand much more.3. Particulate matter reduction efficiency of ceramic filter trap system was about 70%-80%, so it was proved a good system to reduce particulate matter.In experiment, test was conducted to estimate engine emission in 2,476cc light duty diesel engine which was equipped with ceramic filter trap.

  • PDF

PE 피복형 파형강관의 플랜지 이음부 설계에 관한 연구 (A Study on Flange Coupling Design of Polyethylene Corrugated Steel Pipe)

  • 김태규;이호영;양상민
    • 대한기계학회논문집A
    • /
    • 제31권3호
    • /
    • pp.403-408
    • /
    • 2007
  • The concrete pipe(Hume, PC) and polyethylene(PE) pipe are usually used for dram pipe in local market. Hume pipe, however, is heavy and needs the high cost of construction and PC pipe has a disadvantage to easily occur the deformation by the outside pressure even though it is light and constructible. The corrugated steel pipe coated with polyethylene is used increasedly because it is durable, constructible and economical. However, it is not used for sewage or waste water because it is hard to guarantee the watertight property on the coupling part. In this study, we studied on the flange coupling and the method of its construction to guarantee the watertight property and easy to use. If the developed flange coupling and method are used on a construction field, the economical property, constructible property and structural safety can be guaranteed.

히트파이프를 사용한 조명용 LED의 냉각에 대한 연구 (A Study on the Cooling of High Power LED Component using Flat Heat Pipe)

  • 장영운;김병호;임익태
    • 반도체디스플레이기술학회지
    • /
    • 제8권4호
    • /
    • pp.25-29
    • /
    • 2009
  • In this study, a thin plate-type heat pipe, instead of a solid aluminium heat sink, is used to eliminate heat released from LED components for lighting. Effects of the heat pipe size and installation angle are studied both in numerically and experimentally. According to the results, temperature on LED chip, when a heat pipe is used, is $1.2^{\circ}C$ lower than using the conventional metal PCB. The overall temperature drop is $32^{\circ}C$ if the heat pipe is properly used. The highest cooling performance is obtained in the case when the angle of a heat pipe installation is $90^{\circ}$.

  • PDF

배출물 저감을 위한 촉매변환기 내의 3차원 유동해석 (Three-Dimensional Flow Analysis of Catalytic Converter for Reducing Emission)

  • 정수진;김우승
    • 한국자동차공학회논문집
    • /
    • 제6권5호
    • /
    • pp.55-65
    • /
    • 1998
  • A numerical and experimental study of three-dimensional steady incompressible non-reacting flow inside various dual-monolith catalytic converters has been conducted for achievement of performance improvement, reduction of light-off time and longer service life by improving the flow uniformity within the monolith. In this study, the effects of curvature of inlet exhaust pipe and monolith brick length on the flow uniformity and pressure drop within monolith were numerically investigated. The computations are confirmed by measurements of steady flow. The agreement between computations and experiment was relatively good. The result of this study shows that curvature of inlet exhaust pipe and monolith brick length gave a great effect on the flow uniformity and the shorter the brick length, the lower flow uniformity and the less pressure drop.

  • PDF

구조화된 직선빔을 이용한 구조파 전기 저항 용접파이프의 비드 형상 측정에 관한 연구 (A study on based shape monitoring in HERW pipe production by using structured light beam)

  • 고국원;김종형;조형석;공원일
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1993년도 한국자동제어학술회의논문집(국내학술편); Seoul National University, Seoul; 20-22 Oct. 1993
    • /
    • pp.672-678
    • /
    • 1993
  • The bead shape in high frequency electric resistance (HER) pipe welding gives important information ons judging current welding state. In most manufacturing process, the heat input is controlled by skilled operators observing color and bead shape. We proposed the bead shape monitoring system in HERW pipe process by using structured light beam. We reconstructs 3-D shape of bead from the measured data, and compare this shape with real 3-D shape obtained by coordinate-measuring machine. This experiment results show that the proposed system can monitor the bead shape with good accuracy.

  • PDF

파이프 비닐온실용 권취식 창개폐기의 개발 (Development of roll - up ventilation system for pipe- constructed plastic film greenhouse)

  • 이기명;박규식;김유일;김태홍
    • 생물환경조절학회지
    • /
    • 제4권2호
    • /
    • pp.232-239
    • /
    • 1995
  • This study was carried out to get required torque data needed to design and develop a roll-up ventilation system in a pipe-constructed plastic film green-house. The results obtained from this study are as follows : 1. The required torques of a roll-up ventilation system in greenhouse are the functions of its length. The torques should multiplied by the conversion coefficients (2.0 in ceiling vent, 1.8 in side vent) in case of application. 2. In constructing pipe-constructed plastic film greenhouse, a shaft pipe is the largest essential element in roll - up shaft weight constitution which have an effect on the required torques. Therefore, the pipe should be light using nonferrous materials like aluminum alloy. 3. A planetary reduction ventilator of differential ring gear type is suitable for a roll-up ventilation system, because it can make high efficient reduction just using the first step shift.

  • PDF

Analysis of the experimental cooling performance of a high-power light-emitting diode package with a modified crevice-type vapor chamber heat pipe

  • Kim, Jong-Soo;Bae, Jae-Young;Kim, Eun-Pil
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제39권8호
    • /
    • pp.801-806
    • /
    • 2015
  • The experimental analysis of a crevice-type vapor chamber heat pipe (CVCHP) is investigated. The heat source of the CVCHP is a high-power light-emitting diode (LED). The CVCHP, which exhibits a bubble pumping effect, is used for heat dissipation in a high-heat-flux system. The working fluid is R-141b, and its charging ratio was set at 60 vol.% of the vapor chamber in a heat pipe. The total thermal conductivity of the falling-liquid-film-type model, which was a modified model, was 24% larger than that of the conventional model in the LED package. Flow visualization results indicated that bubbles grew larger as they combined. These combined bubbles pushed the working fluid to the top, partially wetting the heat-transfer area. The thermal resistance between the vapor chamber and tube in the modified design decreased by approximately 32%. The overall results demonstrated the better heat dissipation upon cooling of the high-power LED package.

탄소나노히팅파이프를 이용한 온실 난방에너지 절감효과 (Energy Saving Effects of Carbon Nano Heating Pipe for Heating of Greenhouse)

  • 백이;전종길;윤남규
    • 한국기계기술학회지
    • /
    • 제13권3호
    • /
    • pp.107-111
    • /
    • 2011
  • This carbon nano heating system was consisted of power supply equipment, a carbon fiber and a stainless flexible hose. carbon nano heating system was manufactured by carbon fiber of a power capacity 30kw/h and light-oil hot air heater in control plot was the heating capacity 30,000kcal/h, As the result, Temperature difference due to carbon nano heating system and hot air heater in greenhouse showed that air temperature at experimental greenhouse, comparison greenhouse were $14.8^{\circ}C$, $13.4^{\circ}C$ respectively. It was found that carbon nano heating system and light-oil hot air heater heating cost were 1,095,740won, 2,683,628won. therefore as heating cost saving 60%. Yield of tomatoes cultured in greenhouse using carbon nano heating pipe was 4% inclease. Economic analysis comparison between the carbon nano heating pipe and the hot air heater in greenhouse were 41% respectively.

매설조건에 따른 연성관의 변형특성 (Deformation Characteristics of Flexible Pipe with Variation of Buried Conditions)

  • 이봉직
    • 한국지반환경공학회 논문집
    • /
    • 제15권10호
    • /
    • pp.53-62
    • /
    • 2014
  • 국내의 경우 하수관으로 많이 사용되어 온 관종은 콘크리트 흄관으로 대표되는 강성관이 주를 이루고 있으나, 시간 경과에 따른 관 부식 및 수밀성 부족 등의 이유로 사용이 급격히 감소하고 있다. 반면에 연성관은 부식에 강할 뿐만 아니라 자재의 무게가 경량이어서 시공성이 우수한 장점이 있어 사용이 증가하고 있는 실정이다. 그러나 연성관에 대한 시장의 신뢰성 부족과 미흡한 다짐관리로 인한 국부적인 파손사례가 발생하고 있어 이에 대한 원인분석 및 관리방안이 필요한 실정이다. 이에 본 연구에서는 시공순서, 관의 강성, 관 하부 콘크리트 기초의 강도, 관 하부 모래기초의 다짐도, 관 주변 모래의 다짐도 및 관 상단 되메움재의 다짐도 등을 변화시켜 가며 각각의 조건에 따른 관의 변형특성을 수치해석을 통하여 평가하였다. 평가결과 각 인자에 대한 영향을 확인할 수 있었으며 특히 연성관의 경우 관 주변 모래의 품질관리가 중요한 것으로 나타났다.