• Title/Summary/Keyword: Lifting force

검색결과 160건 처리시간 0.031초

Manual Muscle Test 중 상지거상저항 검사 시 근력 오류 발생 원인에 대한 고찰 (Study about the Causes of Muscle Force Mistake Occurrence from the Upper Limb Lifting Resistance Test in Manual Muscle Test)

  • 안성훈;양승범;이영준;황성연;김재효;손인철
    • 턱관절균형의학회지
    • /
    • 제1권1호
    • /
    • pp.13-18
    • /
    • 2011
  • Objectives: We investigated muscle force from the upper limb lifting resistance test to conform the objectivity in manual muscle test. Methods: We made standard method in upper limb lifting resistance test to compare with experiment method switching the lower limb position left & right. And resistance forces of upper limb of subject were checked to inspector with closing eyes. Results: 1. The lifting resistance of right upper limb was stronger when the lower limb of right and left were abducted. 2. The lifting resistance of right upper limb was weaken when the lower limb of right and left were adducted. 3. The lifting resistance of right upper limb was weaken when the lower limb of right and left were elevated. Conclusions: As the above results, the deltoid muscle force checked in the upper limb lifting resistance test is affected by the location of lower limbs, it suggested that the muscle force of some part in the body will be affected by the other parts. It will be useful to understand the symmetry principle of body in muscle function.

  • PDF

A Study on the Measurement of Contact Force of Pantograph on High Speed Train

  • Seo Sung-Il;Cho Yong-Hyun;Mok Jin-Yong;Park Choon-Soo
    • Journal of Mechanical Science and Technology
    • /
    • 제20권10호
    • /
    • pp.1548-1556
    • /
    • 2006
  • Appropriate contact force is required for the pantograph on the high speed train to collect current from the catenery system without separation. However, at high speed, large aerodynamic lifting force is generated by the contact plate and the body of pantograph, which may cause wear of the contact wire. In this study, to confirm the interface performance of the pantograph on Korea High Speed Train, a method to measure the contact force of the pantograph was proposed and the related measuring system was developed. The forces acting on the pantograph were clarified and a practical procedure to estimate the forces was proposed. A special device was invented and applied to measure the aerodynamic lifting force. Measured contact forces were displayed by the developed system and evaluated based on the criteria.

Quantitative study of acupuncture manipulation of lifting-thrusting using an needle insertion-measurement system in phantom tissue

  • Lee, Soo-Yoon;Son, Young-Nam;Choi, In-Hwa;Shin, Kyung-Min;Kim, Kap-Sung;Lee, Seung-Deok
    • 대한한의학회지
    • /
    • 제35권4호
    • /
    • pp.74-82
    • /
    • 2014
  • Objectives: Quantification, objectification, and standardization of lifting-thrusting manipulation are important issues in traditional Chinese medicine (TCM). The purpose of this study was to quantitatively investigate the difference in the amount of stimulation according to range and frequency among parameters of lifting-thrusting manipulation with the use of a needle insertion-measurement system. Methods: For quantification of lifting-thrusting manipulation, an acupuncture needle insertion-measurement system was used in phantom tissue. The motor and force sensors of the needle insertion device were connected to the control software. This enabled operation of the lifting-thrusting manipulation and measurement of the acupuncture needle force. The measurement of the acupuncture needle force according to various frequencies (0.25, 0.50, 0.75, and 1 Hz) and ranges of movement (2, 4, 6, 8, and 10 mm) was repeated 10 times. Results: At a constant frequency of movement, acupuncture needle force according to range of movement (2, 4, 6, 8, and 10 mm) increased with increasing range of movement (p < 0.05). At a constant range of movement, acupuncture needle force according to frequency of movement (0.25, 0.50, 0.75, and 1.0 Hz) increased with increasing frequency of movement (p < 0.05). Conclusion: In this study, we conducted a quantitative comparison of the amount of stimulation according to range and frequency, the main parameters of lifting-thrusting manipulation, by using an acupuncture needle insertion-measurement system. Future studies on various manipulations and parameters are warranted to quantify and objectify the amounts of stimulation by acupuncture manipulation.

선박블록 탑재용 러그구조의 설계합리화를 위한 연구 (A Study for Rationalization of Lifting Lug Design of Ship Block)

  • 함주혁
    • 한국해양공학회지
    • /
    • 제11권4호
    • /
    • pp.249-261
    • /
    • 1997
  • A basic study on the lifting lug design has performed through the rational and systematic process. In order to evaluate the proper design-load distribution around lug eye investigation of contact force between lifting lug and shackle pin is performed using non-linear parametric analysis idealized by gap element models. Gap element modeling and nonlinear analysis procedures are illustrated and discussed based on MSC/NASTRAN. Some analysis and design guides are suggested through the consideration of several important effects such as stress distribution pattern, circumferential contact force distribution along the lug eye face, loading share rate between lug main plate and doubler, effect of loading direction, relation between applied force and deflection and size effect of shackle pin radius. Additionally optimum design studies are performed and general trends according to the variation of design parameters are suggested.

  • PDF

환경 하중을 고려한 침몰 선체의 물리 기반 인양 시뮬레이션 (Physics-based Salvage Simulation for Wrecked Ship Considering Environmental Loads)

  • 함승호;노명일;김주성;이혜원;하솔
    • 대한조선학회논문집
    • /
    • 제52권5호
    • /
    • pp.387-394
    • /
    • 2015
  • Before salvaging a wrecked ship, the physics-based simulation is needed to predict lifting force before real operation by floating crane or barge. Procedures affecting lifting force for the salvage can be divided into three stages. At the first stage, the bottom breakout force for the wrecked ship to escape from seabed sediment should be calculated. At the second step, the current force acting on the wrecked ship while lifting from the seabed to near sea surface should be considered. Finally, buoyancy change near at the sea surface when the wrecked ship start to escape from the water should be considered. In the previous studies, only the breakout force at the first stage was calculated based on simple assumption of embedment depth and contact area of the wrecked ship. Therefore, we develop a program for salvage simulation including whole stages. It is composed of four modules such as the equations of motion, time integration, force calculation, and visualization. As a result, it is applied to simulate lifting the wrecked ship according to various environmental loads including seabed sediments.

한 손 들기 작업과 내리기 작업의 요추부위(L5/S1) 부하에 대한 비교 연구 (Comparison of Biomechanical Stress on Low Back(L5/S1) for One-hand Lifting and Lowering Activity)

  • 김홍기
    • 산업경영시스템학회지
    • /
    • 제37권4호
    • /
    • pp.72-81
    • /
    • 2014
  • Even though two-hands lifting/lowering activity of manual materials handling tasks are prevalent at the industrial site, many manual materials handling tasks which require the worker to perform one-hand lifting/lowering are also very common at the industrial site, forestry, farming, and daily life. The objective of this study was to compare one-hand lowering activity to lifting activity in terms of biomechanical stress for the range of lowering heights from knuckle height to 10cm above floor level with two workload 7.5kg and 15.0kg. Eight male subjects with LMM were asked to perform lifting/lowering tasks using both a one-handed (left-hand and right-hand) as well as a two-handed technique. Spinal loading was estimated through an EMG-assisted free-dynamic biomechanical model. The biomechanical stress of one-hand lowering activity was shown to be 43% lower than that of one-hand lifting activity. It was claimed that the biomechanical stress for one-hand lifting/lowering activity is almost twice (194%) of the one for two-hands lifting/lowering activity. It was also found that biomechanical stress by one-hand lowering/lifting activity with the half workload of two-hands lowering/lifting activity was greater than that of the two-hands lowering/lifting activity. Therefore, it might be a risk to consider the RWL of one-hand lowering/lifting activity to simply be a half of the RWL of two-hands lowering/lifting activity recommended by NIOSH.

한 손 들기 작업과 양 손 들기 작업의 근력 능력 비교 연구 (Comparison of Muscle Strength for One-hand and Two-hands Lifting Activity)

  • 김홍기
    • 대한인간공학회지
    • /
    • 제26권2호
    • /
    • pp.35-44
    • /
    • 2007
  • Work-related musculoskeletal disorders (WMSDs) are a major problem in industries in which manual materials handling is performed by workers. To prevent these WMSDs, it is necessary to understand the muscular strength capability and use this knowledge to design job and selection and assignment of workers. Even though two-hands lifting activity of manual materials handling tasks are prevalent at the industrial site, many manual materials handling tasks which require the worker to perform one-hand lifting are also very common at the industrial site and forestry and farming. However, a few researches have been done for one-hand lifting activity of manual materials handling tasks. The objective of this study is to compare one-hand and two-hands lifting strength in terms of static and dynamic strength of the lifting activity for the ranging from the height of knuckle to elbow. It is shown in this study that the isometric lifting strength of one-hand is ranging from 54.7 to 63.3% of the one of two-hands. However, it is found that there is no significant difference between a person's isometric lifting strength for left-hand and right-hand. It is also shown that there is no significant difference between the peak force under the dynamic sub-maximal loading with one-hand and two-hands lifting activity. Similar results were obtained for the peak acceleration and peak velocity under the dynamic sub-maximal loading with one-hand and two-hands lifting activity. Isometric lifting strength at the height of knuckle was ranging from 2 to 3 times of the dynamic peak force during sub-maximal lifting. It is concluded that the dynamic peak forces under the sub-maximal loading are not highly correlated with the isometric lifting strength in similar postures.

부산종합운동장 주경기장 케이블 지붕구조물의 시공 (Construction of Cable Roof Structure for Pusan Main Stadium)

  • 이주영;유상현
    • 한국공간구조학회논문집
    • /
    • 제2권1호
    • /
    • pp.51-58
    • /
    • 2002
  • Construction of roof structure, cable suspended structure, for Pusan main stadium is adapted a lifting method that is VSL lifting system. 5 processes are practiced for erection of the roof structure including the first lifting process for erection of upper cables and the second lifting process for erection of lower cables. Since all cables of this roof structure with two open spelter sockets are determined their length, some cable were wrong length, he roof structure would be unstable. But, At complete of erection for the roof structure each cable is attained to theoretical tension force with average 4% errors.

  • PDF

Quantitative Comparison of Acupuncture Needle Force Generation According to Diameter

  • Lee, YeonSun;Bong, SungMin;Kim, Eun Jung;Lee, Seung Deok;Jung, Chan Yung
    • Journal of Acupuncture Research
    • /
    • 제35권4호
    • /
    • pp.238-243
    • /
    • 2018
  • Background: Various factors can alter the efficacy of acupuncture treatment, such as the location of points, manipulations, depth of insertion, needle retention time, and needle type. In this study, the effect of needle diameter on the efficacy of acupuncture treatment was quantitatively evaluated. Methods: Five acupuncture needles of different diameters used in clinical practice were compared. Force on the porcine tissue phantom was measured using a sensor. Lifting-thrusting and twisting-rotating movements were performed using a needle insertion-measurement system. After repeated measurements, force magnitude was calculated and compared. Following this, we correlated needle diameter and force magnitude during lifting-thrusting and twisting-rotating movements. Results: The force magnitude was significantly altered between needle diameters during lifting-thrusting movements, as shown by a significant positive correlation between needle diameter and force magnitude. In contrast, there was no difference in force magnitude with different needle diameters during twisting-rotating movements. Conclusion: Needle diameter can significantly affect stimuli and force magnitude dependent upon the type of manipulation. Research into the effect of other needle type characteristics and stimulation method is necessary to fully elucidate the role of acupuncture needle choice in treatment efficacy.

규칙적 들어올리기 작업에 있어서의 들기 가속도와 피로도와의 관계연구 (Fatigue Effect on Lifting Acceleration During Frequent Liftings)

  • Kim, Young-Joun
    • 대한인간공학회지
    • /
    • 제21권1호
    • /
    • pp.27-32
    • /
    • 2002
  • The objective of this study was to investigate the effects of fatigue, caused by frequent manual lifting. on lifting velocity and lifting acceleration. Ten male volunteers performed lifting at a rate of 4 times per minute, continuously, for two hours using the free-style posture A box($30cm{\times}30cm{\times}20$) with a fixed weight (15.9 Kg) was used as the load for lifting, Heart rate, oxygen consumption, and EMG were also measured to estimate the level of fatigue, The posture as well as acceleration was recorded. The results showed that the lifting acceleration at the end of two hour increased significantly (20%, p<0.001) compared to the acceleration after fifteen minutes of lifting. It was also found that subjects changed their lifting postures as the result of fatigue. All subjects also indicated pain in their upper legs and the lower back at the conclusion of the experiment.